• 제목/요약/키워드: Marine generator

검색결과 245건 처리시간 0.034초

선행 탑재장에서의 공간일정계획에 관안 연구 (A Study on Spatial Scheduling in the P.E. Stage)

  • 구충곤;윤덕영;배태규;조민철
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.61-66
    • /
    • 2004
  • In this paper an effort is made to develop an innovative spatial arrangement concept pertaining to ship building industry. The spatial scheduling is the problem that concentrates on effective planning of available space and arrangements of blocks and in a priority manner. In order to create an effective spatial scheduling. a database providing the priority has to be available to make the erection sequence. Such a system works hand in hand with erection sequence generator program The erection sequence program works on the conventional network analysis method which uses a typical parent-children idea for the calculation of the ENT(possible earliest network start time) and LNT(possible latest network start time). This program works in a cyclic manner taking turns by calculating the ENT in upward trace and LNT on the return trace thereby generating the entire erection sequence diagram for the requisite problem The generated database serves as an input data for spatial scheduling problem. When the system works it takes into consideration the entire system based on heuristic concepts as mentioned. There system uses the spatial aspects such as the available area of the P. E area and plan area of the corresponding blocks and its priority of erection from the erection sequence generator program develops the spatial scheduling arrangement. In this paper using all these concepts an innovative spatial schedule development system developed.

  • PDF

Experimental and numerical investigations on effect of reverse flow on transient from forced circulation to natural circulation

  • Li, Mingrui;Chen, Wenzhen;Hao, Jianli;Li, Weitong
    • Nuclear Engineering and Technology
    • /
    • 제52권9호
    • /
    • pp.1955-1962
    • /
    • 2020
  • In a sudden shutdown of primary pump or coolant loss accident in a marine nuclear power plant, the primary flow decreases rapidly in a transition process from forced circulation (FC) to natural circulation (NC), and the lower flow enters the steam generator (SG) causing reverse flow in the U-tube. This can significantly compromise the safety of nuclear power plants. Based on the marine natural circulation steam generator (NCSG), an experimental loop is constructed to study the characteristics of reverse flow under middle-temperature and middle-pressure conditions. The transition from FC to NC is simulated experimentally, and the characteristics of SG reverse flow are studied. On this basis, the experimental loop is numerically modeled using RELAP5/MOD3.3 code for system analysis, and the accuracy of the model is verified according to the experimental data. The influence of the flow variation rate on the reverse flow phenomenon and flow distribution is investigated. The experimental and numerical results show that in comparison with the case of adjusting the mass flow discontinuously, the number of reverse flow tubes increases significantly during the transition from FC to NC, and the reverse flow has a more severe impact on the operating characteristics of the SG. With the increase of flow variation rate, the reverse flow is less likely to occur. The mass flow in the reverse flow U-tubes increases at first and then decreases. When the system is approximately stable, the reverse flow is slightly lower than obverse flow in the same U-tube, while the flow in the obverse flow U-tube increases.

직렬아크현상의 검출기술 및 장치 (Detection Technique and Device of Series Arcing Phenomena)

  • 지홍근;정광석;박대원;길경석;서동환;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.332-338
    • /
    • 2010
  • 전력계통에서 아크현상이 원인이 되는 전기화재는 전기제품의 사용증가에 따라 급증하고 있으나, 이들 사고를 방지할 수 있는 확립된 방법은 없다. 이들 배경에서 본 논문은 공기조화기에서 직렬아크 검출 기술과 장치에 대한 실험적 결과에 대해 기술하였다. 공기조화기의 불완전한 접속부에서 발생하는 직렬아크를 모의하고, 주파수 스펙트럼을 FFT로 분석한 결과, 190 kHz~250 kHz와 900 kHz~1.6 MHz 에 존재함을 알 수 있었다. 저역차단주파수가 170 kHz이며 60 Hz를 176 dB까지 감쇄시킬 수 있는 아크검출 및 파형정형 회로를 설계하였다. 또한 스위치 조작, 인버터 운전 및 서지 등에 의해 발생하는 노이즈로부터 직렬아크신호를 분리할 수 있는 알고리즘을 제안하였다. 적용실험은 UL1699에 규정 되어있는 아크발생장치를 이용하여 여러 형태의 공기조화기에서 수행되었으며, 99 %이상 검출능력을 나타내었다.

판형 열교환기의 열전달과 유동특성에 대한 연구 (Study on Characteristics of Heat Transfer and Flow in Plate Heat Exchanger)

  • 김진화;이광성;지명국;정한식;정효민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1476-1483
    • /
    • 2009
  • In present work, experiments conducted to investigate the heat transfer characteristics and relationship between operating parameters and production of fresh water as output of the system. Plate Heat Exchanger (PHE) applied in vacuum evaporator for product fresh water that system intended to efficiently use low grade heat. PHE have become popular in chemical, power, food and refrigeration industries due to the efficient heat transfer performance, extremely compact design and flexibility of extend or modify to suit changed duty. The heat transfer part contains corrugated plates with 60 degree of chevron angle which verified by many researchers and commonly apply. Fresh water can be produced from saline water under near vacuum pressure by operating ejector. Consequently, evaporating temperature stay around $51-57^{\circ}C$ so it is possible to use any low grade heat source or renewable source. The maximum fresh water produced by freshwater generator with plat heat exchanger applied in the study was designed as 1.0 Ton/day.

  • PDF

해안지역 주거시설을 위한 전력수요 변동 대응형 하이브리드 발전시스템 도입 효과 예측에 관한 사례연구 (A feasibility study on the hybrid power generation system considering of electricity needs' fluctuation of coastal area's houses)

  • 황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권8호
    • /
    • pp.977-983
    • /
    • 2013
  • 본 연구는 섬 주거시설의 전력부하 변동특성에 적합한 태양광발전설비와 풍력발전설비로 구성된 하이브리드 발전시스템의 발전특성을 예측하고 성능을 평가하는 것을 목적으로, 경상남도 통영시에 소재하는 곤리도를 대상으로 수행한 사례연구 결과이다. 연구 결과, 시각별 전력부하 변동률, 시각별 풍력 발생 변동률, 시각별 일사량 변동률 등이 서로 다르기 때문에, 단순히 전력부하측과 풍력 혹은 태양광발전설비를 1:1로 조합한다면 상호간에 불균형이 발생하여 비효율적임을 알 수 있었다. 또한 부하용량선정방법인 최대부하법과 일일부하법으로 하이브리드 발전시스템의 각 용량을 설정할 경우의 성능을 비교한 결과 두 방법 모두 축전지를 포함한 풍력발전설비만 설치했을 때가 가장 효과적인 것으로 나타났는데 이는 풍력은 태양광과 달리 24시간 지속적으로 발생하기 때문이다.

코사인 점호방식에 의한 단상 싸이클로콘버터의 설계에 관한 연구 (A Study on the Design of Single Phase Cycloconverter by Cosine Wave Crossing Control Method)

  • 김시헌;안병원;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권5호
    • /
    • pp.71-85
    • /
    • 1993
  • The Cycloconverter that the author is going to treat in this paper, has strong advantages over the D.C. Link Inverter in points of chattering torque problem and natural commutation. Thus, the Cycloconverter is expected to be well applied to large and low-speed machines which require better speed control at low frequency. But the control circuit of Cycloconverter has two weak points described as follows. 1) Because of its rather complicated control circuit, it is likely to be illoperating due to unexpected noise signals, thus the higher the accuracy and reliability of the circuit is required to be, the more the circuit may cost. 2) Because the load current is not purely sinusoidal, the Cycloconverter may possibly be destroyed in case of inaccurate convert switching resulted from the difficulties in detecting the load current-zero and the current direction at the moment. In this paper, the author first of all intends to design and build a modified VVVF-type Noncirculating Current Cycloconverter to which recently proposed control methods are applied for improving the circuit simplicity, the control performance, and the system reliability. And then, experiments for observing the output waveforms of the Cycloconverter which is controlled by Singled-Board Computer using 8086 16-bit microprocesser are carried out. Finally the author concludes the result of this study as follows. 1) By replacing the conventional analog control circuits such as Reference Wave Generator, Cosine Timing Wave Generator, and Comparator with softwares, a great circuit simplicity is achieved. 2) The output of the designed Cycloconverter changes its frequency very fast without showing discontinuity of its waveform, and this waveform characteristics enables the smooth speed control of Induction Motor. 3) The design control circuit of Cycloconverter can be applied to the systems of 12 or 24 pulses because of its short processing period.

  • PDF

제주 연해 수중 주변소음 계류 측정과 환경 변화에 따른 분석 (Moored measurement of the ambient noise and analysis with environmental factors in the coastal sea of Jeju Island)

  • 정인용;민수홍;팽동국
    • 한국음향학회지
    • /
    • 제39권5호
    • /
    • pp.390-399
    • /
    • 2020
  • 본 연구는 풍력, 파력발전기가 설치되는 제주 동부와 서부 수심 20 m 연해에서 4개월동안 수중 청음기를 중층(10 m)에 계류하여 주변소음을 측정하였다. 측정 소음레벨에 영향을 미치는 기상정보는 측정 지점 근처 기상대와 관측소를 이용하여 자료를 수집하였다. 100 Hz 이하의 주파수 대역에서 조석의 영향으로 간조와 만조, 조금과 사리일 때 약 5 dB ~ 20 dB가량 변화를 보였다. 파랑과 바람의 영향은 1 kHz 이하의 주파수 대역에서 25 dB이내로 큰 변화를 보였으며 파랑은 저주파 대역에 영향을 주었고 바람은 1 kHz 이상의 고주파 대역까지도 영향을 주었다. 10 kHz 이상의 고주파 대역에 영향을 주는 요인으로 강우와 생물 소음이 있고 웬즈 곡선 최대값에 비해 약 10 dB 높게 측정되었다.

A Study on the Performance and Flow Distribution of Fresh Water Generator with Plate Heat Exchanger

  • Jin, Zhen-Hua;Kim, Pil-Hwan;Lee, Gyeong-Hwan;Choi, Soon-Ho;Chung, Han-Shik;Jeong, Hyo-Min
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.611-617
    • /
    • 2008
  • Nowadays Plate Heat Exchanger (PHE) is widely used in different industries such as chemical, food and pharmaceutical process and refrigeration due to the efficient heat transfer performance, extreme compact design and efficient use of the construction material. In present study, discussed main conception of plate heat exchanger and applied in vacuum. PHE and aimed apply in the fresh water generator which installed in ship to desalinate seawater to fresh water use heat from engines. The experiment is proceeded to investigate the heat transfer between cold and hot fluid stream at different flow rate and supply temperature of hot fluid. Generated fresh water as outcome of the system. PHE is an important part of a condensing or evaporating system. One of common assumptions in basic heat exchanger design theory is that fluid is to be distributed uniformly at the inlet of each fluid side and throughout the core. However, in practice, flow mal-distribution is more common and can significantly reduce the heat exchanger performance. The flow and heat transfer are simulated by the k-$\varepsilon$ standard turbulence model. Moreover, the simulation contacted flow maldistribution in a PHE with 6 channels.

  • PDF

기존 선박의 디젤발전기용 SCR 시스템 설치에 관한 연구 (A Study on the Installation of SCR System for Generator Diesel Engine of Existing Ship)

  • 류영현;김홍렬;조규백;김홍석;남정길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.412-417
    • /
    • 2015
  • IMO MEPC에서는 해양환경 보호를 위해서 선박으로부터 배출되는 배기가스 규제를 날로 점점 강화하고 있다. 특히, 2016년부터 건조되어 국제항해를 하는 모든 신조 선박에 대한 질소산화물(NOx) 배출량은 Tier-III 규제를 만족하게 되어 있다. 본 연구에서는 선박용으로 개발된 NOx 저감용 SCR(선택적 환원 촉매) 시스템을 기존 선박의 디젤발전기에 설치하여 NOx 저감성능을 파악하고자 하였다. 본 연구를 위하여 목포해양대학교 실습선 새누리호 디젤발전기의 배기 파이프라인을 개조 공사하여 요소 SCR 시스템을 설치하였으며, 요소 용액(40%) 분사 방법은 수동 모드와 PLC를 통한 자동 모드로 나누어 두 가지 방법으로 실험을 하였다. 수동 모드 방법을 통하여 암모니아 슬립 발생구간을 찾을 수 있었으며, 엔진부하별(25, 35 및 50%)로 최적의 요소 분사량을 조절할 수 있었다. 부하를 Down-Up(25%에서 50%로 올리면서) 시보다도 Up-Down(50%에서 25%로 내리면서) 시에 NOx 저감성능이 더 좋음을 알 수 있었으며, 본 바나듐계 촉매가 사용된 SCR 시스템을 기존 선박의 디젤발전기에 설치하여 질소산화물이 80% 이상 절감됨을 확인할 수 있었다.

공조시스템 개선에 따른 하절기 선실 온열환경 평가 및 유류절감에 관한 연구 - 실습선 새누리호를 중심으로 - (A Study on the Evaluation of Cabin Thermal Environment and Marine Fuels for Fuel Saving in Summer According to the Improvement of Air Conditioning System - The Case of Training Ship SAENURI -)

  • 한승훈;김홍렬
    • 해양환경안전학회지
    • /
    • 제20권6호
    • /
    • pp.653-662
    • /
    • 2014
  • 본 연구에서는 목포해양대학교의 실습선 새누리호를 대상으로 선박의 중앙집중 공조시스템에 공랭식 에어컨을 직접 설치하여 성능을 개선시킨 공기조화시스템으로 운전하였을 경우의 냉방 성능을 비교하고, 선실의 온열환경에 대한 실측조사를 통해서 향후 선박용 공기조화 설계 및 계획에 경험적 기초참고자료로 활용하고자 하는 것이다. 연구결과 동일한 외기조건에서 기존의 중앙집중방식 공조시스템과 개선된 공조시스템으로 운전하였을 경우, 모든 선실의 온도는 $24{\sim}28^{\circ}C$, 습도는 55~75 %로 쾌적한 조건임을 알 수 있었고, 발전기 부하를 측정결과 공기조화시스템의 성능개선에 따라 평균 부하 48 KW, 전부하시 부하율 약 8 %정도 감소하여 1일 연료소모량 FOC는 하루 평균 222[L/day]의 기름이 절약됨을 알 수 있었다. 또한 학생 선실(Cadet No. 21)은 기관실의 전열로 인해서 온도가 높게 나타났는데, 이것은 공기조화 설계 시 취출구 개수 및 전열부하를 고려하지 못한 결과로 판단된다.