• 제목/요약/키워드: Marginal microleakage

검색결과 67건 처리시간 0.031초

올인원 접착제의 미세누출에 관한 정량적 분석 (A QUANTITATIVE ANALYSIS ABOUT MICROLEAKAGE OF ALL-IN-ONE ADHESIVES)

  • 강용희;신수일;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권1호
    • /
    • pp.66-72
    • /
    • 2004
  • All-in-one adhesives were recently developed for reducing the technique sensitivity and chair time, but lots of concerns were made on bondability, longevity, and microleakage. The object of this study was to evaluate microleakage and marginal quality of all-in-one adhesives using electrochemical method and SEM analysis quantitatively. After making Class V cavities, they were bulk filled with Heliomolar(#A1 after surface treatment with three adhesives: Adper Prompt (Group A), One up bond F (Group O), Xeno III (Group X) Electrical conductivity (microamphere, ${\mu}A$) was checked two times: before and after cavity filling. Percentage of leaky margin was estimated from SEM image (${\times}1,000$). The data were statistically analysed: ANOVA and Paired T test for electrical conductivity, Kruskal-Wallis and Mann-Whitney test for marginal quality, Spearman s rho test for checking of relationships between 2 methods. The result were as follows: 1. There was no difference in microleakage between adhesive systems and every specimen showed some of microleakage after filling. 2. Microleakage was reduced about 70% with composite resin filling. 3. Marginal quality was the best in group A. decreasing among groups in the following order: group O, followed by group X. There were significant differences between group A and group X (p=0.015), and between group 0 and group X (p=0.019). 4. There was no relationship between the microleakage measured by electrochemical method and marginal quality measured by SEM analysis. Within the results of this study, there was no difference in microleakage among groups by electrical conductivity. However, significant difference in marginal quality was seen among groups. It was believed that these dissimilar results might be induced because of their own characteristics. Analysis of microleakage needs various methods for accuracy.

근관와동 가봉재 종류에 따른 변연누출의 비교 분석 (COMPARATIVE ANALYSIS OF MARGINAL MICROLEAKAGE IN VARIOUS TEMPORARY SEALING MATERIALS)

  • 윤창;홍석진
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.151-157
    • /
    • 1991
  • The roles of temporary sealing materials used in endodontics are impotant Especially, its marginal sealing properties affect endodontic success and failure in endodontic treatment The purpose of this in vitro study was to compare and evaluate the marginal sealing properties of various temporary restorative materials used in endodontic access cavity by using electrochemical method. Standard endodontic access cavities were prepared in extracted human molar teeth and filled with Caviton, IRM, zinc oxide - eugenol cement. Each specimen was immersed in 1 % solution of KCl, and applied a potential of 9 V external power supply. Marginal microleakage and water sorption were measured for marginal sealing effect evaluation in comparison with each group. A comparative study of the obtained results have led to the following conclusions. 1. The Caviton group showed lower marginal microleakage value than the zinc oxide - eugenol cement and IRM group the 6 th day after. The IRM group showed lwoer marginal microleakage value than the zinc oxide - eugenol cement group from the 6 th day to the 12 th day. But there was no significant difference between zinc oxide - eugenol cement and IRM group after the 13 th day. 2. As time went by, marginal microleakage value was increased in Caviton, IRM and zine oxide - eugenol cement.

  • PDF

상아질 접착제의 미세누출과 변연부 혼화층 (MICROLEAKAGE AND MARGINAL HYBRID LAYER OF DENTIN ADHESIVES)

  • 조영곤;김영관;안종모
    • Restorative Dentistry and Endodontics
    • /
    • 제27권1호
    • /
    • pp.34-43
    • /
    • 2002
  • The purpose of this study was to compare microleakage and marginal hybrid layer in class V restorations using two one-bottle adhesives and one self-etching adhesive. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were pre-pared on buccal and lingual surfaces of 30 extracted human molar teeth. Prepared teeth were randomly divided into three treatment groups (n=30) and restored with three adhesives and composites: Single Bond/Filtek Z-250 (Group 1), Prime&BondNT/Esthet.X (Group 2), UniFil Bond/UniFil F (Group 3). For microleakage, samples were stored in room temperature water for 24 hours, thermocycled stained with 2% methylene blue dye, sectioned into halves, scored and analysed using Mann-whitney test and Wilcoxon signed rank sum test. For marginal hybrid layer, samples were sectioned into halves, treated with 10% phosphoric acid for 5 seconds, stored in 5% NaOCL solution for 24 hours, dried and gold coated. Occlusal and gingival margins of each sample were inspected under SEM. The results of this study were as follows ; 1. Microleakage at the occlusal margins was not evident in group 1 and group 2, but it showed in group 3 (p<0.05). 2. Microleakage in group 1 and group 3 was significantly lower than in group 2 at gingival margins (p<0.05). 3. Microleakage at gingival margins was greater than at occlusal margins in group 1 and group 2, but microleakage at occlusal margins was greater than at gingival margins in group 3 (p<0.05). 4. In group 1 and group 2, no gaps at occlusal margins showed. But gaps showed in group 3. Occlusal margins were free from a hybrid layer in all groups 5. The thickness of the marginal hybrid layers was 2.5~5 $\mu\textrm{m}$ thick in group 5 $\mu\textrm{m}$ thick in group 2 and 1.5 $\mu\textrm{m}$ thick in group 3. 6 There was no corelation between microleakage and thickness of marginal hybrid layer. In coclusion, the effect of dentin adhesives on microleakge in class V composite restorations was excellent when one-bottle adhesives were applied on enamel margin, and it was good when a self-etching adhesive was applied on dentinal margin. There was no corelation between microleakage and thickness of marginal hybrid layer.

단일 단계 접착제의 변연 미세누출 (MARGINAL MICROLEAKAGE OF SINGLE STEP ADHESIVES)

  • 조영곤;정진호;기영재;최희영;진철희;유상훈;김종욱;박병철
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.162-169
    • /
    • 2004
  • This study evaluated the marginal microleakage of five single step adhesives. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of the single step adhesives and composite resins:Prompt L-Pop/Filtek Z-250 (Group 1), AQ Bond/Metafil CX (Group 2), One-Up Bond F/Palfique Toughwell (Group 3). Futurabond/Admira (Group 4), Xeno III/Spectrum TPH (Group 5). The restored teeth were thermocycled. Microleakage was assessed by dye penetration using 2% methylene blue dye solution. The teeth were bisected buccolingually and evaluated for microleakage under steromicroscope. The data were statistically analysed by Kruskal-Wallis test and Mann-Whitney tests. The results of this study were as follows:1. Microleakage of enamel margins in group 3 was statistically higher than that in groups 1, 2, 4, 5 (p < 0.05). 2. Microleakage of dentin margins in group 1 was statistically higher than that in groups 2, 5, and that in group 3 was statistically higher than that in groups 2, 4, 5 (p < 0.05). 3. Dentin marginal microleakage was higher than enamel marginal microleakage in all experimental groups. In conclusion, Prompt L-Pop showed the least leakage at enamel margin, and AQ Bond showed at dentin margin in this study. Marginal miroleakage in dentin was higher than that in enamel.

수복에 따른 구치부 복합레진 수복물의 변연부 미세누출 및 적합도 (MICROLEAKAGE AND MARGINAL ADAPTATION OF POSTERIOR COMPOSITE RESIN RESTORATIONS ACCORDING TO RESTORATIVE TECHNIQUE)

  • 양인서;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.334-346
    • /
    • 1997
  • Incidence of using esthetic composite resin in the posterior area is increasing but there were lots of inconsistent reports about their microleakage and marginal adaptation. The purpose of this study was to evaluate the differences of microleakage and marginal adaptation according to restorative techniques. 30 cavities with enamel gingival margin were prepared and restored with 3 types of composite resin [Z-100($Scotchbond^{TM}$ MP), AELITEFIL ($Onestep^{TM}$), Her culite XRV(Fuji BOND LC)] in direct technique and another 30 cavities were restored with preformed CR inlays and 3 different modern resin and resin-modified GI cements (Superbond C&B, Choice, Fuji Duet). Samples were chemically stressed in 75% ethanol for 24 hours and were thermocycled (5-$55^{\circ}C$(500 times. The degree of microleakage through proximal and gingival margins was examined by 1 % MB dye and the degree of marginal adaptation by examining the margins via SEM. The following results were obtained ; 1. In direct groups, Herculite XRV [Fuji BOND LC, 35.13 (15.50) %] group showed statistically different, less microleakage than Z-100 [$Scotchbond^{TM}$ MP, 72.91 (16.91 %] group and AELITEFIL [One-step, 93.73 (13.66) %] group (p<0.05). 2. In indirect groups, the degree of microleakage in Mean(S.D.) were: Super bond C & B [39.00 (24.35) %], Choice [57.19 (33.80) %], Fuji Duet [58.22 (40.36) %]. But there was no significant difference. 3. There was no significant difference between resin cement and resin-modified GI cement. 4. There were gaps at the interface with the tooth structure, but no gap was seen at the interface with restoration in all specimens. 5. In direct groups, Herculite XRV(Fuji BOND LC) group made little gap compared with other groups, but 40-$50{\mu}m$ thickness of bonding agent, Fuji BOND LC, looked like a cement used in indirect technique. 6. All indirect groups showed a variety of cement thickness, from less than $20{\mu}m$ to over $100{\mu}m$ and that dimension of buccal/lingual margin was less than that of gingival margin.

  • PDF

Nanofilled 복합레진으로 와동 충전 시 flowable 레진 사용 유무에 따른 피로시험 후의 미세 변연 누출 비교 (Comparison of microleakage after load cycling for nanofilled composite resin fillings with or without flowable resin lining)

  • 한선덕;김원;최지영;오남식;이명현
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.342-347
    • /
    • 2009
  • 연구 목적: 제2급 와동에서 nanofilled 레진 충전 시 기구 조작 방향에 따라 변연 누출 가능성이 있다. 따라서 기구 조작에 따른 변연 누출을 줄이고자 인접면변연에 flowable 레진의 사용 유무에 따라 반복 하중 전후에 미세 변연 누출의 차이를 보고자 하였다. 연구 재료 및 방법: 건전한 상태의 24개의 발치 된 치아를 제2급 와동으로 형성한 뒤 그룹F는 nanofilled 레진으로 충전 시 flowable 레진을 liner로 사용하였고, 그룹 NF는 nanofilled 레진으로만 충전 하였다. 300N의 하중으로 $10^4$, $10^5$, $10^6$번의 반복하중을 가했다. 반복하중 전후로 모든 시편에서 전체 미세 변연 누출 길이 (T), 축면 미세 변연 누출 길이 (A), 치은 미세 변연 누출 길이 (G), 협측 미세 변연 누출 길이 (B), 설측 미세 변연 누출 길이 (L)를 측정하여, 각변연누출비율을 비교하였다. 통계는 Mann-Whitney test와 Wilcoxon signed ranks test로 하였다. 결과: 하중 전에 그룹F의 전체 미세 변연 누출 백분율은 0.6%이고 그룹 NF는 5.6%이며, 하중 후에는 그룹 F는 13.0%이고 그룹 NF는 36.3%로 그룹 NF에서 미세 변연 누출이 컸고, 반복 하중 횟수가 증가할수록 더욱 커졌으며, 부위상으로는 치은 변연의 미세 변연 누출이 컸다. 통계적 분석 결과 그룹NF의반복횟수별 하중 전후 비교에서 경계성으로 유의한 차이를 보였다. 결론: 제2급 와동에서 nanofilled 레진 충전 시 인접면 변연에 flowable 레진을 liner로 사용할 경우 반복 하중 전후에 미세 변연 누출의 감소에 영향을 주었다. 그리고 liner로 사용된 flowable 레진은 300 N의 반복 하중에서도 견딜 수 있었다.

IRM 임시수복이 상아질 접착제의 변연 미세누출에 미치는 영향 (THE INFLUENCE OF IRM TEMPORARY RESTORATIONS ON MARGINAL MICROLEAKAGE OF DENTIN ADHESIVES)

  • 조영곤;김현경;이영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2003
  • This study investigated the influence of IRM on marginal microleakage of 5th generation adhesives. Class V cavities with gingival margins in dentin were prepared on both buccal and lingual surfaces of 60 extract-ed human molar teeth. Prepared teeth were randomly divided into six groups. Group 1 and 4 received no temporary restoration with IRM. Group 2 and 5 were covered with IRM mixed at P/L ratio(10g/1g). Group 3 and 6 were covered with IRM mixed at P/L ratio(10g/2g). The temporary restorations were removed mechanically with an ultrasonic scaler after one-week storage in distilled water. The cavities were restored using one of two adhesives and composites ; Single Bond/Filtek Z 250(Croup 1, 2 and 3), UniFil Bond/UniFil F(Group 4, 5 and 6). Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles(between $5^{\circ}C{\;}and{\;}55^{\circ}C$) and immersed in 2 % methylene blue for dye penetration testing. The results were analysed using Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked test at a significance level of 0.05. The results of this study were as follows 1. Ranking of mean microleakage scores at the enamel margins was Group 10.05) 4. At the dentin margins, the microleakage of the group not pretreated with IRM was lower than that of the group pretreated with IRM. And the microleakage of UniFil Bond was lower than that of Single Bond. 5. Compared with microleakages between the enamel and dentin margins of each groups, Group 1, 2, 3, 4, 5 and 6 at dentin margin were higher microleakage than those at enamel margin. There were significant difference between enamel and dentin microleakage of Group 2 and 3(p<0.05).

역행충전시 수복재와 와동 형태에 따른 변연누출의 정량적 분석 (QUANTITATIVE ANALYSIS OF MARGINAL MICROLEAKAGE IN VARIOUS RETROGRADE FILLING MATERIALS AND PREPARATION TYPES)

  • 한충경;양홍서
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.97-105
    • /
    • 1990
  • When conventional root canal treatment is failed or contraindicated, retrograde root canal filling following apicoectomy is a valuable procedure, aimed at hermetically sealing the root canal against leakage of irritants from the canal into the periapical tissue. In this in vitro investigation, to analyze apical microleakage electrochemically in teeth with different retrograde filling materials and preparation types, single - rooted tooth was cut 2mm from the apex and each Class I and Slot preparation was prepared. Experimental groups : Group 1. Amalgam filling with cavity varnish in Class I preparation Group 2. Scotchbond 2+Silux filling in Class I preparation Group 3. Gutta percha filling with ZOE cement in Class I preparation Group 4. Amalgam filling with cavity varnish in Slot preparation Group 5. Scotchbond 2+Silux filling in Slot preparation Each specimens was immersed in 1% solution of KCl, and applied a potential of 9V external power supply. Measurements of the current flow were obtained at 1, 2, 3, 7, 9, 12, 14, 18, 21, 25 and 28 day after immerson. Marginal microleakage were compared and evaluated. The results were as follows ; 1. The group filled with composite resin with dentin bonding agent shows lower apical microleakage value than the group filled with amalgam following varnish application (P<0.01). 2. In the group filled with gutta percha, apical microleakage value was the hightest 3. There was no significant difference between Class I cavity and Slot type cavity regardless of the used materials.

  • PDF

3차원 재구성법을 이용한 수복물의 정량적 미세누출도 측정 (NEW QUANTITATIVE MEASURING TECHNIQUE FOR MICROLEAKAGE OF THE RESTORED TOOTH THROUGH 3D RECONSTRUCTION)

  • 하상윤;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.413-422
    • /
    • 2004
  • Established microleakage tests have their own disadvantages. In this study, 3D reconstruction method was tried to overcome these disadvantages. Four types of microleakage tests were used and relationships among them were estimated: penetrated dye volume: marginal adaptability: degree of dye penetration and relative penetrated length to cavity wall. Twenty-four Class V cavities were bulk filled with composite (Esthet X) following surface treatments: N group (no treatment): E group (etching only): T group (etching + Prime & Bond NT). 50% silver nitrate was used as a dye solution after thermocycling ($5^{\circ}C{\;}&{\;}55^{\circ}C$, 1.000 times). Teeth were serially ground with a thickness of 0.2 mm. Volume of dye penetration was estimated from a three-dimensionally reconstructed image with a software (3D-DOCTOR). Percentage of margin without gap was estimated from SEM and degree of dye penetration and the relative length of dye penetration to overall cavity wall were also estimated. ANOVA and Scheffe test for dye volume, Kruskal-Wallis and Mann-Whitney test for marginal quality, Spearman's rho test for checking of relationships among methods were used. The results were as follows: 1. Dye penetration could be seen from several directions, furthermore, its volumetric estimation was possible. 2. Reverse relationship was found between dye volume and marginal quality (r = -0.881/ p = 0.004). 3. Very low relationship was seen between dye volume and two-dimensional tests (degree of dye penetration and relative length). However, 2D evaluation methods showed high relationship (p = 0.002-0.054) each other. 4. Three times vertical section could be recommended as a 2D test.

수복물의 미세누출도와 변연적합도 측정에 사용되는 방법 사이의 상관 관계 평가 (ESTIMATION OF RELATION BETWEEN TECHNIQUES OF DYE PENETRATION FOR MICROLEA-KAGE AND SEM EVALUATION FOR MARGINAL ADAPTATION OF THE RESTORATION)

  • 황순주;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제31권5호
    • /
    • pp.337-343
    • /
    • 2006
  • 본 연구에서는 색소 침투법을 이용한 5급 복합레진 수복물의 미세누출도와 주사전자 현미경을 이용한 변연적합도를 측정하고 두 방법 사이의 상관성을 평가하고자 하였다. 발거된 사람의 대구치 20개의 협면에 고속의 330번 버를 이용하여 5급 와동을 (백아법랑경계부를 중앙으로 가로 4 mm, 세로 3 mm, 깊이 1.5 mm) 형성하고, 평가시 참고점으로 사용하고자 1/2번 원형 버로 6개의 함몰부를 만들었다. 제조사의 지시에 따라 단일 단계의 올인원 접착제인 Xeno III로 치면을 처리한 다음, 미세혼합형 복합레진인 Esthet X로 단일 충전하였다. 시편을 식염수에 1일간 보관한 후 Sof-Lex 시스템으로 마무리 및 연마하였다. 이후 5도와 55도에서 1000회 열순환시킨 다음, 50%질산은 용액을 이용하여 침투시켰다. 실리콘 고무 인상재와 폴리우레탄 모형재로 수복물 주변의 레진 복제물을 제작하고 금도금한 다음 주사전자현미경으로 외부 및 내부 변연부의 변연적합도를 측정하였다. 또한 참고점을 기점으로 수복물을 3분한 다음, 미세누출도를 측정하였다. 내부 및 외부 변연적합도와 미세누출도 평가법 사이의 상관관계는 Spearman's rho test를 이용하여 다음과 같은 결과를 얻었다. 1. 미세누출도와 각각의 외부 및 내부 변연 적합도는 유의한 상관관계를 보였다 (p <0.01). 2.내부와 외부의 변연 적합도 사이에는 유의한 상관관계를 보이지 않았다.