• Title/Summary/Keyword: Margin of safety

Search Result 493, Processing Time 0.035 seconds

Application of a combined safety approach for the evaluation of safety margin during a Loss of Condenser Vacuum event

  • Shin, Dong-Hun;Jeong, Hae-Yong;Park, Moon-Ghu;Sohn, Jung-Uk
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1698-1711
    • /
    • 2022
  • A combined safety approach, which uses a best-estimate computer code and adopts conservative assumptions for safety systems availability, is developed and applied to the safety margin evaluation for the Loss of Condenser Vacuum (LOCV) of the 1000 MWe Korean Nuclear Power Plant. The Multi-dimensional Analysis of Reactor Safety-KINS standard (MARS-KS) code is selected as a best-estimate code and the PAPIRUS program is used to obtain different initial operational conditions through random sampling of control variables. During an LOCV event, fuel integrity is not threatened by the increase in Departure from Nuclear Boiling Ratio (DNBR). However, the high pressure in the primary coolant system and the secondary system might affect the system integrity. Thus, the peak pressure becomes a major safety concern. Transient analyses are performed for 124 cases of different initial conditions and the most conservative case, which results in the highest system pressure is selected. It is found the suggested methodology gives similar peak pressures when compared to those predicted from existing methodologies. The proposed approach is expected to minimize the time and efforts required to identify the conservative plant conditions in the existing conservative safety methodologies.

Evidence-based approach for herbal medicine-safety classification : Human equivalent dose-based the margin of safety (한약의 안전성 등급화를 위한 evidence-based approach : Human equivalent dose-based the margin of safety)

  • Park, Yeong-Chul;Lee, Sundong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.17 no.3
    • /
    • pp.19-30
    • /
    • 2013
  • This study was aimed to develop a new formula for herbal medicine-safety classification in terms of evidence-based medicine. Recently, human equivalent dose(HED)-based therapeutic index was developed for herbal medicine-safety classification by transforming $LD_{50}$ to HED. However, the use of the $ED_{50}$ and $LD_{50}$ to derive the therapeutic index may be misleading as to safety, depending on the slope of the dose-response curves for therapeutic and lethal effects. To overcome this deficiency, HED-based MOS(Margin of Safety)was developed and suggested in this study. The HED-based MOS developed by using $LD_1$, changing to ALD(approximate lethal dose), and $ED_{99}$. The HED-based MOS seems to be more useful and safer than HED-based therapeutic index since its values for several herbal medicines are basically two times less than the values from HED-based therapeutic index. Thus, HED-based MOS can be a good example of Evidence-based approach for herbal medicine-safety classification.

Probabilistic Analyrgis of Slope Stactility for Progressive Failure (진행성 파괴에 대한 사면안정의 확률론적 해석)

  • 김영수
    • Geotechnical Engineering
    • /
    • v.4 no.2
    • /
    • pp.5-14
    • /
    • 1988
  • A probabilistic model for the progressive failure in a homogeneous soil slope consisting of strain-softening material is presented. The local safety margin of any slice above failure surface is assumed to follow a normal distribution. Uncertainties of the shear strength along potential failure surface are expressed by one-dimensional random field models. In this paper, only the case where failure initiates at toe and propagates up to the crest is considerd. The joint distribution of the safety margin of any two adjacent slices above the failure surface is assumed to be bivariate normal. The overall probability of the sliding failure is expressed as a product of probabilities of a series of conditional el.eats. Finally, the developed procedure has been applied in a case study to yield the reliability of a cut slope.

  • PDF

A Research on Optimization of Lead-lag Controller Setpoint for Rod control system to prevent fluctuation for NPP (원전 제어봉제어계통 순시변동을 방지하기위한 지상-지연회로 설정치 최적화 연구)

  • Yoon, Duk-Joo;Lee, Jae-Yong;Kim, In-Hwan;Kim, Joo-Sung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1149-1154
    • /
    • 2007
  • Fluctuation of control rod was experienced when plant was operating in normal operation mode in WH type NPPs. In order to cope with increased control rod fluctuation, the lead-lag controller setpoint for rod control system was optimized and resulted in increasing the margin of operation and minimizing unnecessary control rod movement. By optimization of the time constant, the margin of operation was increased by $1.5^{\circ}F$ and the control rod movement was not occurred due to mitigation of temperature fluctuation in loop. According to the mitigation of time constant, the margin of operation was increased but safety margin can be affected badly, so that the influences to FSAR design reference was evaluated. As the result of this evaluation, it satisfied the design reference of the existing safety analysis and was applied to NPP after obtaining the approval.

  • PDF

Implicit Treatment of Technical Specification and Thermal Hydraulic Parameter Uncertainties in Gaussian Process Model to Estimate Safety Margin

  • Fynan, Douglas A.;Ahn, Kwang-Il
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.684-701
    • /
    • 2016
  • The Gaussian process model (GPM) is a flexible surrogate model that can be used for nonparametric regression for multivariate problems. A unique feature of the GPM is that a prediction variance is automatically provided with the regression function. In this paper, we estimate the safety margin of a nuclear power plant by performing regression on the output of best-estimate simulations of a large-break loss-of-coolant accident with sampling of safety system configuration, sequence timing, technical specifications, and thermal hydraulic parameter uncertainties. The key aspect of our approach is that the GPM regression is only performed on the dominant input variables, the safety injection flow rate and the delay time for AC powered pumps to start representing sequence timing uncertainty, providing a predictive model for the peak clad temperature during a reflood phase. Other uncertainties are interpreted as contributors to the measurement noise of the code output and are implicitly treated in the GPM in the noise variance term, providing local uncertainty bounds for the peak clad temperature. We discuss the applicability of the foregoing method to reduce the use of conservative assumptions in best estimate plus uncertainty (BEPU) and Level 1 probabilistic safety assessment (PSA) success criteria definitions while dealing with a large number of uncertainties.

A Study on Improved Allocations of Permissible Water Pollution Load at the Implementing Stage of Tatal Water Pollution Load Management Plan (수질오염총량관리계획의 시행단계에서 오염부하량 할당방안 개선에 관한 연구)

  • Kim Sie-Heon;Rim Jay-Myung
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.51-56
    • /
    • 2005
  • Allocation of water pollution load from loading capacity can be much essential, controversial, and its standards can be applied case-by-case to the various situations. Allocation methods to point sources are generally 'Equal effluent concentration', 'Equal percent Treatment', Loading capacity at planning stage consists of basic pollution load, development pollution load, reserved pollution load and margin of safety. But at the implementing stage loading capacity can be consisted of allocatable load and margin of safety to give more flexibility in the total water pollution load management plan. In that case, we can re-adjust and altogether use the pollution load of point sources of series and non-point sources at the implementing stage.

Structural Integrity and Safety Margin Evaluation for Thinned Pipe Component (감육배관의 구조건전성 및 안전여유도 평가 기술)

  • Lee, Sung-Ho;Kim, Tae-Ryong;Kim, Bum-Nyun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.264-267
    • /
    • 2004
  • Wall thinning of carbon steel pipe components due to Flow-Accelerated Corrosion (FAC) is one of the most serious threats to the integrity of steam cycle piping systems in Nuclear Power Plants (NPP). Since the mid-1990s, secondary side piping systems in Korean NPPs have experienced wall thinning, leakages and ruptures caused by FAC. Korea Electric power Research Institute (KEPRI) and Korea Hydro & Nuclear Power Co., LTD. (KHNP) have conducted a study to develop the methodology for systematic pipe management and established the Korean Thinned Pipe Management Program (TPMP). To effectively maintain the integrity of piping system, FAC engineer should understand the criterions of the structural integrity evaluation and the safety margin assessment for the thinned pipe component. This paper describes the technical items of TPMP, and shows the example of the integrity evaluation and safety margin assessment for three thinned pipe component of a NPP.

  • PDF

Operational Mode Analysis of Cooler Driver Electronics in Satellite and System Safety Margin

  • Kim, Kyudong
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.79-84
    • /
    • 2020
  • Cooler driver electronics (CDE) for maintaining low temperature of the satellite payload IR sensor consists of a compressor that has a pulsation current load condition when it is operated. This pulsation current produces large voltage fluctuation, which affects both load and regulated bus stability. Thus, CDE power conditioning system consists of a primary bus, infrared power distribution unit for battery charging and protection, reverse current protection diode, and battery, which is used as a buffer. In this study, the operational mode analysis is performed by each part with equivalent impedance modeling verified through system level simulation. From this mode analysis, the safety margin for state of charge and open circuit voltage of the battery is determined for satisfying the minimum operational voltage of the CDE load.

A Heuristic Application of Critical Power Ratio to Pressurized Water Reactor Core Design

  • Ahn, Seung-Hoon;Jeun, Gyoo-Dong
    • Nuclear Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.68-79
    • /
    • 2002
  • The approach for evaluating the critical heat flux (CHF) margin using the departure from nucleate boiling ratio (DNBR) concept has been widely applied to PWR core design, while DNBR in this approach does not indicate appropriately the CHF margin in terms of the attainable power margin-to-CHF against a reactor core condition. The CHF power margin must be calculated by increasing power until the minimum DNBR reaches a DNBR limit. The Critical Power Ratio (CPR), defined as the ratio of the predicted CHF power to the operating power, is considered more reasonable for indicating the CHF margin and can be calculated by a CPR orrelation based on the heat balance of a test bundle. This approach yields directly the CHF power margin, but the calculated CPR must be corrected to compensate for many local effects of the actual core, which are not considered in the CHF test and analysis. In this paper, correction of the calculated CPR is made so that it may become equal to the DNB overpower margin. Exemplary calculations showed that the correction tends to be increased as power distribution is more distorted, but are not unduly large.

Determination and risk characterization of polycyclic aromatic hydrocarbons of tea by using the Margin of Exposure (MOE) approach

  • Lee, Joon-Goo;Lim, Taesuk;Kim, Sheen-Hee;Kang, Dong-Hyun;Yoon, Hae-Jung
    • Food Science and Biotechnology
    • /
    • v.27 no.6
    • /
    • pp.1843-1856
    • /
    • 2018
  • Tea is one of the most frequently consumed drinks due to its favourite taste and the health benefit. Tea is produced by several processes and drying is very important step to develop the flavour and destroys the enzymes in tea. However, during drying tea, polycyclic aromatic hydrocarbons some of which are carcinogen and genotoxin are naturally produced. The risk of PAHs by drinking tea was characterized by determining contents of 4 PAHs in tea. 4 PAHs including Benz(a)anthracene (BaA), Chrysene (CHR), Benzo(b)fluoranthene (BbF) and Benzo(a)pyrene (BaP) were investigated by GC-MS in total 468 tea products, which were contaminated up to $4.63ng\;g^{-1}$. Mate tea was the most highly contaminated by BaA, CHR, BbF and BaP and followed by Solomon's seal and Chrysanthemum. The Margin of Exposures calculated by the concentration of BaA, CHR, BbF and BaP and consumption amount of tea were higher than 10,000, and the risk of PAHs in tea were low concern to public health.