• Title/Summary/Keyword: Major ion analysis

Search Result 211, Processing Time 0.026 seconds

Direct Analysis in Real Time Mass Spectrometry (DART-MS) Analysis of Skin Metabolome Changes in the Ultraviolet B-Induced Mice

  • Park, Hye Min;Kim, Hye Jin;Jang, Young Pyo;Kim, Sun Yeou
    • Biomolecules & Therapeutics
    • /
    • v.21 no.6
    • /
    • pp.470-475
    • /
    • 2013
  • Ultraviolet (UV) radiation is a major environmental factor that leads to acute and chronic reactions in the human skin. UV exposure induces wrinkle formation, DNA damage, and generation of reactive oxygen species (ROS). Most mechanistic studies of skin physiology and pharmacology related with UV-irradiated skin have focused on proteins and their related gene expression or single-targeted small molecules. The present study identified and analyzed the alteration of skin metabolites following UVB irradiation and topical retinyl palmitate (RP, 5%) treatment in hairless mice using direct analysis in real time (DART) time-of-flight mass spectrometry (TOF-MS) with multivariate analysis. Under the negative ion mode, the DART ion source successfully ionized various fatty acids including palmitoleic and linolenic acid. From DART-TOF-MS fingerprints measured in positive mode, the prominent dehydrated ion peak (m/z: 369, M+H-$H_2O$) of cholesterol was characterized in all three groups. In positive mode, the discrimination among three groups was much clearer than that in negative mode by using multivariate analysis of orthogonal partial-least squares-discriminant analysis (OPLS-DA). DART-TOF-MS can ionize various small organic molecules in living tissues and is an efficient alternative analytical tool for acquiring full chemical fingerprints from living tissues without requiring sample preparation. DART-MS measurement of skin tissue with multivariate analysis proved to be a powerful method to discriminate between experimental groups and to find biomarkers for various experiment models in skin dermatological research.

Investigation on Source Strength to Acid Rain in the Seoul Area (서울시 산성비의 원인물질에 관한 연구)

  • 신응배;이상권;안규홍
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.66-74
    • /
    • 1986
  • Rain samples were collected at 10 sites in the Seoul area during the period of August through November, 1985. THe concentrations of the major cations $(H^+, Ca^{++}, MG^{++}, Na^+, K^+, NH_4^+)$ and the major anions $(SO_4^=, NO_3^-, Cl^-)$ were measured to characterize the main sources of chemical ions in rainwater. Correlating concentrations of ions to pH, calculated coefficients ranged from 0.1485 to 0/4296. Sulfate shows the largest coefficient indicating that sulfate is more closely associated with hydrogen ion than other ions. This may suggest that sulfuric acid contributes more to the acidity of rainwater in Seoul. It appears that the major chemicals measured in rainwater are from the anthropogenic sources of air pollution. Predominant chemicals are acidic at the Guro-, the Sinseol-, the Yangnam-, and the Ssangmun-dong with sulfate being the most predominant. IT also indicates that alkaline substances resulting from soil and dust have a significant effect on pH values of rainwater by neutralizing actions. According to Granat-model analysis, it is estimated that the relative contributions to the rainwater acidity in Seoul are 84% from sulfuric acid, 8% from nitric acid and 8% from hydrochloric acid.

  • PDF

Analysis of Solid Oxide Fuel Cell/Oxy-fuel Combustion Power Generation System Using Oxygen Separation Technology (산소분리기술을 사용한 연료전지/순산소연소 발전시스템 해석)

  • Park, Sung-Ku;Kim, Tong-Seop;Sohn, Jeong-Lak;Lee, Young-Duk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.51-54
    • /
    • 2008
  • This study aims to devise and analyze a power generation system combining the solid oxide fuel cell and oxy-fuel combustion technology. The fuel cell operates at an elevated pressure, a constituting a SOFC/gas turbine hybrid system. Oxygen is extracted from the high pressure cathode exit gas using ion transport membrane technology and supplied to the oxy-fuel power system. The entire system generates much more power than the fuel cell only system due to increased fuel cell voltage and power addition from oxy-fuel system. More than one third of the power comes out of the oxy-fuel system. The system efficiency is also higher than that of the fuel cell only system. Recovering most of the generated carbon dioxide is major advantage of the system.

  • PDF

A Study on the Analysis of Methylprednisolone Acetate and its Metabolites in Rat Urine by LC/MS (LC/MS를 이용한 뇨중에서의 Methylprednisolone Acetate 및 그 대사물질 분석에 관한 연구)

  • Park, Song-Ja;Pyo, Hee Soo;Kim, Yun Je;Park, Seong Soo;Park, Jongsei
    • Analytical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.139-159
    • /
    • 1995
  • Positive ion mass spectra of some corticosteroids were obtained by using liquid chromatography-mass spectrometry(LC-MS). The base peak of each compound showed the protonated molecular ion [$MH^+$], ammonium adduct ion [${MNH_4}^+$] or [$MH^+-60$] ion according to its chemical structure and other characteristic mass ions were [$MH^+-18$], [${MNH_4}^+-18$] and so on. Several rat urinary metabolites of methylprednisolone acetate after the oral administration were detected by the thermospray LC-MS. The identified major metabolites were 20-hydroxymethylprednisolone(20-HMP), methylprednisolone(MP) and methylprednisone(11-KMP), which were supposed to be formed by deacetylation at the position of C-21, reduction at C-20, oxidation at C-11, or due to the bond cleavage between C-17 and C-20.

  • PDF

Quantitative Analysis of Citrate in Foods Using a Potentiometric Enzyme Biosensor (전위차법 효소 바이오센서를 이용한 식품의 구연산 정량분석)

  • Kwon, Ji-Young;Kim, Mee-Ra
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.169-175
    • /
    • 2006
  • Potentiometric biosensor using flow injection analysis system was developed to determine citrate concentration in foods. Biosensor system consisted of sample injector, peristaltic pump, enzyme reactor, carbonate ion selective solid-state electrode, reference electrode, detector, and recorder. Enzyme reactor was prepared with immobilized citrate lyase and oxaloacetate decarboxylase. Carbonate ions produced through enzyme reactions of citrate were potentiometrically detected by ion selective electrode. Optimum conditions for biosensor system were investigated. Interference effect of major sugars and organic acids was less than 5% on citrate biosensor system. Citrate concentrations in fruit juices were determined by biosensor and gas chromatography. No significant difference was observed between two analytical methods. Results indicate citrate biosensor is useful in determining citrate concentration in foods.

Design Analysis of Current Density in Lithium Secondary Battery Using Data Mining Techniques (데이터 마이닝을 이용한 리튬 이차전지의 전류밀도 영향인자 분석)

  • Jeong, Dong Ho;Lee, Jongsoo;Choi, Ha-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.6
    • /
    • pp.677-682
    • /
    • 2014
  • In the present study, a decision tree and artificial neural network were used to determine critical design parameters for lithium ion batteries and compare their performances. First, a design method that used a decision tree-artificial neural network model was used to determine the major design factors among early pole plate design factors that showed nonlinearity. Then, the artificial neural network was used to implement a weighted value analysis of the importance of the design factors and their effect on the current density. The second method involved the use of an artificial neural network model to construct artificial networks without separate determinations of the major early design factors to analyze the connections and weighted values related to the current density.

Electrochemical Properties of 3D Cu-Sn Foam as Anode for Rechargeable Lithium-Ion Battery (3D-foam 구조의 구리-주석 합금 도금층을 음극재로 사용한 리튬이온배터리의 전기화학적 특성 평가)

  • Jung, Minkyeong;Lee, Gibaek;Choi, Jinsub
    • Journal of Surface Science and Engineering
    • /
    • v.51 no.1
    • /
    • pp.47-53
    • /
    • 2018
  • Sn-based lithium-ion batteries have low cost and high theoretical specific capacity. However, one of major problem is the capacity fading caused by volume expansion during lithiation/delithiation. In this study, 3-dimensional foam structure of Cu-Sn alloy is prepared by co-electrodeposition including large free space to accommodate the volume expansion of Sn. The Cu-Sn foam structure exhibits highly porous and numerous small grains. The result of EDX mapping and XPS spectrum analysis confirm that Cu-Sn foam consists of $SnO_2$ with a small quantity of CuO. The Cu-Sn foam structure electrode shows high reversible redox peaks in cyclic voltammograms. The galvanostatic cell cycling performances show that Cu-Sn foam electrode has high specific capacity of 687 mAh/g at a current rate of 50 mA/g. Through SEM observation after the charge/discharge processes, the morphology of Cu-Sn foam structure is mostly maintained despite large volume expansion during the repeated lithiation/delithiation reactions.

Lower the Detection Limits of Accelerator Mass Spectrometry

  • John A., Eliades;Song, Jong-Han;Kim, Jun-Gon;Kim, Jae-Yeol;O, Jong-Ju;Kim, Jong-Chan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.243-244
    • /
    • 2013
  • Over the past 15 years, several groups have incorporated radio-frequency quadrupole (RFQ) based instruments before the accelerator in accelerator mass spectrometry (AMS) systems for ion-gas interactions at low kinetic energy (<40 eV). Most AMS systems arebased on a tandem accelerator, which requires negative ions at injection. Typically, AMS sensitivity abundance ratios for radioactive-to-stable isotope are limited to Xr/Xs >10^-15, and the range of isotopes that can be analyzed is limited because of theneed to produce rather large negative ion beams and the presence of atomic isobaric interferences after stripping. The potential of using low-kinetic energy ion-gas interactions for isobar suppression before the accelerator has been demonstrated for several negative ion isobar systems with a prototype RFQ system incorporated into the AMS system at IsoTrace Laboratory, Canada (Ontario, Toronto). Requisite for any such RFQ system applied to very rare isotope analysis is large transmission of the analyte ion. This requires proper phase-space matching between the RFQ acceptance and the ion beam phase space (e.g. 35 keV, ${\varphi}3mm$, +-35 mrad), and the ability to control the average ion energy during interactions with the gas. A segmented RFQ instrument is currently being designed at Korea Institute for Science and Technology (한국과학기술연구원, KIST). It will consist of: a) an initial static voltage electrode deceleration region, to lower the ion energy from 35 keV down to <40 eV at injection into the first RFQ segment; b) the segmented quadrupole ion-gas interaction region; c) a static voltage electrode re-acceleration region for ion injection into a tandem accelerator. Design considerations and modeling will be discussed. This system should greatly lower the detection limits of the 6 MV AMS system currently being commissioned at KIST. As an example, current detection sensitivity of 41Ca/Ca is limited to the order of 10^-15 while the 41Ca/Ca abundance in modern samples is typically 41Ca/Ca~10^-14 - 10^-15. The major atomic isobaric interference in AMS is 41K. Proof-of-principal work at IsoTrace Lab. has demonstrated that a properly designed system can achieve a relative suppression of KF3-/41CaF3- >4 orders of magnitude while maintaining very high transmission of the 41CaF3- ion. This would lower the 41Ca detection limits of the KIST AMS system to at least 41Ca/Ca~10^-19. As Ca is found in bones and shells, this would potentially allow direct dating of valuable anthropological archives and archives relevant to our understanding of the most pronounced climate change events over the past million years that cannot be directly dated with the presently accessible isotopes.

  • PDF

The Benefit-Cost analysis for Korea Lithium-ion Battery Waste Recycling project and promotion plans (국내 중대형 이차전지 재활용 사업의 경제성 분석 및 발전방안 연구)

  • Mo, Jung-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.326-332
    • /
    • 2018
  • Korea faces major changes in energy policy, which include eco-friendly and zero-nuclear power. On the other hand, there are very few policies for the waste-management of mid- to large-sized lithium-ion batteries, such as electric car batteries and energy storage systems, which are expected to increase explosively due to such energy policy changes. Therefore, this study estimated the amount of mid- to large-sized lithium ion batteries waste and performed economics analysis of a middle and large sized secondary battery recycling project. Based on the results, a policy alternative for the revitalization of the related lithium-ion battery recycling industry is suggested. As a result, the B / C ratio of a domestic mid - to large - sized lithium ion battery recycling project is 1.06, in which the benefit is higher than the cost, so the business is economic feasible. Although the recycling project's economic efficiency is high, the recycling industry has not been activated in Korea because the domestic demand for rechargeable batteries recycling is very low. To solve this problem, this study proposes a plan to activate the industry by adding lithium secondary batteries to the EPR (Extended Producer Responsibility) items.