• Title/Summary/Keyword: Maintenance discharge

Search Result 177, Processing Time 0.022 seconds

Implemention of diagnosis algorithm to traction equipment for railway (철도차량 추진시스템의 진단 알고리즘 구현)

  • Ko, Byeong-Hun;Park, Young;Kwon, Sam-Young;Park, Hyun-June;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.500-501
    • /
    • 2007
  • The method of maintenance in railway is going to be changed to improve reliability on traction equipment. Partial discharge (PD) tests are useful to evaluate the insulation condition of stator winding. This paper describes the use of PD tests with 5 model coils which have the defects such as internal, slot discharge. The PD tests are performed with epoxy-mica coupler 500 pF at various AC voltages. The result of test shows PD pattern can correlate with the species of defects on 5 model coils.

  • PDF

Development of On-Line Partial Discharge Monitoring System in High Voltage Motors (고압전동기 운전중 부분방전 감시 시스템 개발)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

A Study on Correlation of Effective Discharge Energy and Exhaust Emission of Gasoline Vehicle (가솔린자동차의 유효방전에너지와 배기가스와의 상관관계 연구)

  • Yoo, Jongsik;Kim, Chulsoo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.70-75
    • /
    • 2014
  • The experiment was done on traveling at the speed of 20km/h, 60km/h and 100km/h using the performance testing mode for chassis dynamometer. The experimental method were employed to measure the waveform of secondary ignition coil and exhaust emission. In this experiment, the correlation between the secondary waveform coming from ignition coil and exhaust emission were measured in decrepit vehicle. The secondary waveform characterized by the value of effective discharge energy. The following results are obtained by analyzing the data relativity between the effective discharge energy and exhaust emission. The variation rate of effective discharge energy was largest 60km/h, 20km/h, 100km/h velocity in the ordered named. As the vehicle velocity increases, the average variation rate of CO and $NO_X$ decreases and that of HC and $CO_2$ decrease. The value of effective discharge energy, CO, $NO_X$ and fuel consumption is measured badly in case of car with failures in MAP, spark plug and good in case of car with before and after maintenance regardless of vehicle velocities. The value of effective discharge energy is to be nearly parabolic shape as vehicle velocity increases. As the value of effective discharge energy increases, the value of $NO_X$, HC and $CO_2$ decrease, the value of CO increase. The most sensible factors of exhaust emission were CO, $NO_X$, and the small variation factors were HC, $CO_2$.

Development of UV Corona Camera for the Detecting of Discharge on Power Facility using UV Transmittance Improvement Filter (UV 투과율 향상 필터 기술을 이용한 전력설비 방전 검출용 자외선 코로나 카메라 개발)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1656-1661
    • /
    • 2012
  • UV inspection technology is being used for predictive maintenance of power facility together with IR-thermography and ultrasonic devices. In this paper, the UV corona camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. The UV corona camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The transmission between 250 to 280nm was 11% ($12.5%{\times}88%{\times}98%$) by combing the transmission on absorption film, window and other filter(UG 5, nickel sulphate and so on). In a distance of 5m with the UV corona camera it is possible to detect partial discharge with a PD level of 2.5pC and a RIV level of $3.6dB{\mu}V$.

A Study on the Joint Property by the Surface Treatment Method on the Jointing Method of PET Film using the High Hardness Liquid (고경질 도막을 이용한 PET 필름 접합공법의 필름 표면처리 방법에 따른 접합특성 연구)

  • Lee, Jong-Suk;Kim, Young-Sam;Shin, Hong-Chol;Kim, Young-Geun;Kang, Chung-Mo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.153-159
    • /
    • 2014
  • This research reviewed the joint and duration characteristics depending on the surface treatment condition and lap spliced length in the PET film jointing method using the high hardness liquid material. As a result, the corona discharge treatment was improved to the contact angle, joint tensile strength, and joint peel resistance compared to non-treatment. Particularly, a surface treatment E (Corona discharge + Primer + PU bond + Polyester fabric) turned out to the best, and especially when the lap spliced length is longer than 15mm, stable joint performance was secured under the long term deterioration treatment of 16 weeks. Thus, the joint is considered to be applicable as the water-proof material.

Channel-forming Discharge Evaluation for Rivers with High Coefficients of River Regime (하상계수가 큰 하천의 하도형성유량 산정)

  • Ji, Un;Jang, Eun Kyung;Yeo, Woon Kwang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4B
    • /
    • pp.361-367
    • /
    • 2011
  • The channel-forming discharge, which is a standard and single flow for the river maintenance and restoration project, should be estimated necessarily in the stable channel design. It is difficult to produce the specific pattern for the channel-forming discharge in the domestic rivers due to the insufficient researches and case studies. Also, it is improper to adopt the foreign cases for the domestic rivers and streams which have the high coefficients of river regime. Therefore, the channel-forming discharge possible to use for rivers with high coefficients of river regime is suggested in this study through analyzing the bankfull, specified recurrence interval, and effective discharges of Mangyeong River, Cheongmi Stream, and Hampyeong Stream for the abandoned channel restoration project. The bankfull discharge was calculated with geometric data using the HEC-RAS modeling and the flow, bed materials, and sediment data for the study reaches were used to estimate the specified recurrence interval and effective discharges. As a result for calculating the channel-forming discharge, the effective discharge was greater than the bankfull discharge in the river with high coefficient of river regime and the effective discharge was greater than the bankfull and there was no correlation between the coefficient of river regime and the characteristics of the specified recurrence interval discharges.

Analysis of PD Distribution Characteristics and Comparison of Classification Methods according to Electrical Tree Source in Power Cable (전력용 케이블 시편에서 전기트리 발생원에 따른 부분방전 분포 특성 및 발생원 분류기법 비교)

  • Park, Seong-Hee;Jeong, Hae-Eun;Lim, Kee-Joe;Kang, Seong-Hwa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.57-64
    • /
    • 2007
  • One of the cause of insulation failure in power cable is well known by electrical treeing discharge. This is occurred for imposed continuous stress at cable. And this event is related to safety, reliability and maintenance. In this paper, throughout analysis of partial discharge(PD) distribution when occurring the electrical tree, is studied for the purpose of knowing of electrical treeing discharge characteristics according to defects. Own characteristic of tree will be differently processed in each defect and this reason is the first purpose of this paper. To acquire PD data, three defective tree models were made. And their own data is shown by the phase-resolved partial discharge method (PRPD). As a result of PRPD, tree discharge sources have their own characteristics. And if other defects (void, metal particle) exist internal power cable then their characteristics are shown very different. This result Is related to the time of breakdown and this is importance of cable diagnosis. And classification method of PD sources was studied in this paper. It needs select the most useful method to apply PD data classification one of the proposed method. To meet the requirement, we select methods of different type. That is, neural network(NN-BP), adaptive neuro-fuzzy inference system and PCA-LDA were applied to result. As a result of, ANFIS shows the highest rate which value is 98 %. Generally, PCA-LDA and ANFIS are better than BP. Finally, we performed classification of tree progress using ANFIS and that result is 92 %.

A Study of Actual Condition on Operation and Management of Environmental Infrastructure in the Geum River System (금강수계 내 환경기초시설 운영실태에 관한 연구)

  • Lee, Jae-Woon;Park, Dong-Gi;Kwon, Young-Ho
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.1
    • /
    • pp.1-12
    • /
    • 2009
  • The various environmental problems that we face on today are basically about environmental quality. Since early 1960s affluent material was produced because of remarkable economic growth by many cooperations. However, for the lack of environmental policy, environmental pollutions has been serious. The central government should transfer the producing and consuming structure to environmental affinity through the regulations for developing Korea as a model of environmental nation which takes an active part in global environmental programme and in which the environment and economy are well harmonized. Moreover, the central government should take the lead in prevention of environmental pollution through the direct policies such as strengthening the discharge limit or setting up environmental basic institutions by securing budget for conserving environment. This thesis emphasize on the public institution among many environmental basic institutions for environmental anti-pollution project. It will find the problems with running those institutions, and will suggest the preview of improvement. Also, it is necessary to investigate of variation trend for inflow and pollutant loading to environmental infrastructure as increased of the diffusion rate as established and maintenance of sewer system. The purpose of this study is to investigate for inflow and pollutant loading to environmental infrastructure, and also to provide the method of efficiently maintenance and management. The results obtained were summarized as follows; 1. Survey of actual condition on operation and management of environmental infrastructure was evaluated the propriety of treatment process and problem of plant management. 2. Analysis of pollutant loading contribution for river system of environmental infrastructure with data analysis of water quality measuring network. 3. To investigate on case study for efficiently maintenance and management of environmental infrastructure. The result on this study was provide the method of efficiently maintenance and management with survey for establish and repair of sewer system and survey of actual condition on operation and management of environmental infrastructure in the water area of discharge to Geum River System. Application as guideline for establish and management of environmental infrastructure, and management of Geum River System. Also, application for preliminary data for fulfill-assess of total effluent regulation of water pollution.

Development of On-tine Partial Discharge Monitoring System for High-Voltage Motor Stator Windings (고압 전동기 고정자 권선의 운전중 절연감시 시스템 개발)

  • Hwang, D.H.;Sim, W.Y.;Park, D.Y.;Gang, Dong-Sik;Kim, Y.J.;Song, S.O.;Kim, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.224-226
    • /
    • 2001
  • In this paper, a novel high-voltage motor monitoring system (HVMMS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, EMC (Epoxy-Mica Coupler) is used for PD measurement PD signals are continuously measured and digitized with a peak-hold A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF

A study of the Effect of groin on the Water Quality in the Urban River (방사보가 도시하천수질에 미치는 영향에 관한 연구)

  • Cho, Hong-je;Kim, ill-gwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.81-90
    • /
    • 1998
  • The purpose of this study was to analyze the effect of the groin which was constructed in the down stream of urban river for the prevention of sedimentation on the improvement of the water quality. We studied on the groin in the downstream of Taehwa River constructed to keep the navigation depth of Ulsan day, and used the measured data of the water quality and river discharge. In order to analyze the charge of the water quality due to the groin Que12E model was applied, and BOD and DO was examined. The analysis showed that removal of the groin would not have significant effect on the improvement of the water quality, rather, interception of the pollution source coming into the upstream of the groin would be more influential on the improvement of the water quality. Therefore, It was concluded that to improve the water quality in mild bottom slop of tidal river, interception of the pollution source and river maintenance discharge should precede.

  • PDF