• 제목/요약/키워드: Main Power Transformer

검색결과 192건 처리시간 0.028초

Balance Winding Scheme to Reduce Common-Mode Noise in Flyback Transformers

  • Fu, Kaining;Chen, Wei
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.296-306
    • /
    • 2019
  • The flyback topology is being widely used in power adapters. The coupling capacitance between primary and secondary windings of a flyback transformer is the main path for common-mode (CM) noise conduction. A Y-cap is usually used to effectively suppress EMI noise. However, this results in problems in space, cost, and the danger of safety leakage current. In this paper, the CM noise behaviors due to the electric field coupling of the transformer windings in a flyback adapter with synchronous rectification are analyzed. Then a scheme with balance winding is proposed to reduce the CM noise with a transformer winding design that eliminates the Y-cap. The planar transformer has advantages in terms of its low profile, good heat dissipation and good stray parameter consistency. Based on the proposed scheme, with the help of a full-wave simulation tool, the key parameter influences of the transformer PCB winding design on CM noise are further analyzed. Finally, a PCB transformer for an 18W adapter is designed and tested to verify the effectiveness of the balance winding scheme.

단상(345kV) 주변압기 압력 계전기의 진동절연에 관한 연구 (A Study on the Vibration Reduction of the SPR(sudden pressure relay) in the Single Phase Main Power Transformers(345kV))

  • 박철준;이성욱;최원호;이욱륜;권기영
    • 한국소음진동공학회논문집
    • /
    • 제20권5호
    • /
    • pp.486-491
    • /
    • 2010
  • In this paper, it is identified that high-level vibration of the single phase main power transformers shut down due to the mechanical fault. vibration sources of the SPR in the transformer's are identified and the SPR vibrations are reduced by structural modification. For vibration characteristic identification, vibration signals were measured with an accelerometer when the transformer is driving. These signals are presented in a FFT analysis in order to find the dependency of frequency components on the transformer. From finite element analyses and some experiments, it is also found that resonances occur because the natural frequencies of the SPR exist in usual driving range. To shift the natural frequencies outside the driving range, the SPR is modified by increasing stiffness. It is verified that considerable amounts of vibration are reduced by the structural modification.

발전소 변압기 소음저감 대책의 유효성 (The effectiveness of noise reduction devices for transformer noise control of Power Plants)

  • 김연환;김희수;배용채;이현;김성휘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1823-1828
    • /
    • 2000
  • Power transformers, air-intakes, stacks in a combined thermal power plant are the main noise sources. Power transformer noise among them has being get a target of public complaint due to 480Hz component of its pure tone. The source is mainly magnetostrictive vibration of the transformer core. The first countermeasures was installing sound barrier on the front of transformer. However, 500Hz, center of the frequency is not reduced. This paper includes the measurements of noise level at the near resident apartment, the identification of noise transfer and the countermeasures for noise sources. Cavity resonance type of noise reduction devices was installed on enclosuring wall of transformers. As a result, the noise level from transformer is reduced about 3dB.

  • PDF

대형변압기 절연상태 평가 (Assessment of Insulation Condition in Large Transformers)

  • 김희동;공태식;이영준;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.499-502
    • /
    • 2004
  • In order to detect of insulation problems an early, transformer has to be performed the several tests. The ac current and tan6 of transformer winding insulation were investigated by Schering bridge. Partial discharge(PD) tests are used to evaluate the insulation condition of transformer. The moisture content measurement was conducted using RVM(recovery voltage meter). The RVM test can show that the problem is affecting the paper insulation of transformer. The value of moisture content was 2.3% in main transformer. The insulations of four transformers were judged to be in good condition.

  • PDF

절연구간운행 고속철도차량 전력품질 특성 분석 (The analysis of power quality characteristics in high speed train through neutral section of catenary system)

  • 홍현표;최의성;이시빈;이희순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.634-643
    • /
    • 2011
  • The neutral section was installed in order to prevent conflict with different phase angle source in electric railway catenary system. The speed of electric train reduced due to coasting operation by notch off when it passed the neutral section. And, the catenary wire was damaged and the accident might be happened because of the arc generation when the electric train passed the neutral section with notch off condition. The inrush current of main transformer installed tiling train is analyzed during the operation of MCB(main circuit break) passing through the neutral section. The instantaneous waveform of load current were analyzed in case of powering and regenerative braking. Inrush current waveform with run of AC railway train showed that inrush current waveform and harmonics, the inrush current generated from main transformer in train has bad effects on power quality problem. In order to reduce these inrush currents, the MCB is connected when the phase angle of voltage is 90 degree. This paper is to measure inrush current and harmonics in main transformer of high speed train in neutral section of electric railway. This measurement report is used to control minimum inrush current in algorithm and power phase angle.

  • PDF

전력공급확률을 이용한 분산형 전원을 고려한 배전계통 신뢰도 평가에 관한 연구 (A Study on the Reliability Evaluation of Power Distribution System with Distributed Generations using Power Supplied Probability)

  • 이희태;문종필;김재철
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2119-2124
    • /
    • 2010
  • Reliability evaluation of power distribution system is the evaluation for all customers supplied from one power source as main transformer located in substation. However, power sources include not only the main transformer but distributed generations. Typical reliability evaluation has focused on configuration of power system with one source including failure rates of equipment. In this paper, we focus on not only configuration but power sources as distributed generations. New reliability evaluation method using power supplied probability (PSP) is proposed. The proposed evaluation method are proved through case studies.

식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석 (Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer)

  • 김지호;이향범
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.

원자력발전소 변압기 연결 선로 결상 검출 시스템 (Open-Phase Condition Detecting System for Transformer Connected Power Line in Nuclear Power Plant)

  • 하체웅;이도환
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.254-259
    • /
    • 2015
  • On January 30, 2012 an auxiliary component of Byron Unit 2 was tripped on bus under voltage. The cause of the event was the failure of the C-phase insulator track for the Unit 2 station auxiliary transformer(SAT) revenue metering transformer. In addition to this event, other events have occurred at other plants resulting in an open-phase condition.[1] Therefore, Nuclear Regulatory Commission(NRC) has requested that not only nuclear power plant(NPP) operating company but also its Design Certification(DC) applicant have to prepare open-phase detecting system in their operating plants and design document. In this paper, various open-phase conditions are simulated in NPP using Electromagnetic Transient Program(EMTP) and Atpdraw, and open-phase condition detecting system is proposed for Main Transformer(MT), Unit Auxiliary Transformer(UAT) and SAT connected power line in NPP.

IEEE Std 693-1997을 적용한 전력용 변압기 내진 해석 (Seismic Qualification Analysis for the Power Transformer with IEEE Std 693-1997)

  • 양재철;노효철;김호영;박균수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.527-531
    • /
    • 2005
  • Because of increasing demand for safety of the power transformer, the seismic qualification process in accordance with the standard of IEEE Std 693-1997 is essentially required by customer. Dynamic analysis method and static analysis method were used to qualify the seismic withstanding of the power transformer at high seismic level. Maximum stress was detected at the connection between the main structure and appendages, and maximum displacement was detected at the point of appendage's end tip. Load path and substructure system can be considered as important elements to prevent over stress and over displacement.

스코트 변압기 보호계전기 오동작 사례분석 및 개선방안 고찰 (A Study on SCOTT Transformer Protection Relay Malfunction Case and Improvement Methodology)

  • 이종화;노영환
    • 한국산학기술학회논문지
    • /
    • 제18권7호
    • /
    • pp.394-399
    • /
    • 2017
  • 본 국내 교류전철변전소에서는 주변압기 2차측의 위상각이 $90^{\circ}$인 단상 전원을 얻도록 한 스코트 결선 변압기를 설치 운용 하고 있다. 변압기 보호계전기는 내부에서 고장이 발생하는 경우 변압기 전단에서 전력을 차단시키고 변압기 외부 계통의 사고나 일반차량 운행의 경우에는 동작하지 않아야 한다. 정확한 고장의 판단으로 오동작을 줄이는 것이 전력계통을 안정적으로 유지하고 신뢰성을 향상시키는 측면에서 매우 중요하다. 주 변압기 내부 고장 검출장치로는 브흐홀쯔계전기와 비율차동계전기를 설치하여 변압기를 보호하고 있지만 비율차동계전기의 오동작으로 인해 보호기능을 비활성화 시켜놓은 상태로 운용하는 사례가 있다. 본 논문에서는 스코트 변압기의 특성과 비율차동계전기의 특성을 제시하고 보호계전기의 오동작 사례를 분석하였다. 이를 위해 전력계통 해석프로그램을 이용하여 스코트 변압기에 사용되는 비율차동계전기를 모델링하고 A변전소의 Comtrade 파일로 저장된 고장파형을 입력데이터로 사용하여 동작여부를 판단하여 고조파 분석을 수행하였다. 또한, 고장파형 분석을 통해 오동작 사례에 대한 개선 방안을 도출하고자 한다.