• 제목/요약/키워드: Main Fan

검색결과 279건 처리시간 0.026초

형상최적화를 통한 축류송풍기의 설계 (Design of An Axial Flow Fan with Shape Optimization)

  • 서성진;최승만;김광용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.578-582
    • /
    • 2004
  • This paper presents the response surface optimization method using three-dimensional Navier-Stokes Analysis to optimize the shape of a axial flow fan. Reynolds-averaged Navier-Stokes equations with k-$\epsilon$ turbulence model are discretized with finite volume approximations. Regression analysis is used for generating response surface, and it is validated by ANOVA. Five geometric variables, i.e., distribution of sweep angle at mean and tip, lean angle at mean and tip, and spanwise location of mean were employed to optimize the efficiency. The computational results are compared with experiment data. As a main result of the optimization, the efficiency was successfully improved.

  • PDF

타워형 에어컨 송풍기 소음의 능동제어 (Active Control of Noise from Fan Blowers in Tower-type Air Conditioners)

  • 류경완;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.87-93
    • /
    • 2017
  • This paper investigates active noise control of tower-type air conditioners using the filtered-x least mean square (FXLMS) algorithm to reduce fan blower noise transmission. Firstly, the main components required for the active control system including the error sensor, the control speaker and the reference sensors are selected. Since the noise could significantly reduce if the reference signal includes every frequency response information, a various reference signals from accelerometers and a microphone are used. Secondly, the controller based on the FXLMS algorithm with a single-channel reference signal is implemented. Then, the control performance is examined experimentally for the different reference signals. It is found that the accelerometer signal well possesses the motor vibration related noise and a microphone signal could includes global noise. When using the reference signal with a microphone located near the motor and the fan blower, the active control system reduces the noise globally, except for several peaks.

축류홴 익단누설와류의 수치적 해석 (Numerical Analysis of a Tip Leakage Vortex in an Axial Flow Fan)

  • 장춘만;김광용
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.36-44
    • /
    • 2004
  • Three-dimensional vortical flow and separated flow topology near the casing wall in an axial flow fan having two different tip clearances have been investigated by a Reynolds-averaged Navier-Stokes (RANS) flow simulation. The simulation shows that the tip leakage vortex formed close to the leading edge of the blade tip on suction side grows in the streamwise direction. On the casing wall, a separation line is formed upstream of the leakage vortex center due to the interference between the leakage vortex and main flow. The reverse flow is observed between the separation line and the attachment line generated downstream of the trailing edge, and increased with enlarging tip clearance. The patterns of a leakage velocity vector including a leakage flow rate are also analyzed according to two tip clearances. It is noted that the understanding of the distribution of a limiting streamline on the casing wall is very important to grasp the characteristics of the vortical flow in the axial flow fan.

맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구 (Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites)

  • 응우엔반득;김두영;허원호;이창우
    • 터널과지하공간
    • /
    • 제28권1호
    • /
    • pp.38-58
    • /
    • 2018
  • 갱내환기는 지하광산 안전성에 직접적인 영향을 미친다. 갱내환기는 정상시에는 작업공간내 유해물질의 희석을 위한 충분한 량의 급기를 통하여 쾌적한 환경을 유지하는 것이 목적이나 갱내화재와 같은 비상시에는 화재의 확산제어와 구조활동의 지원을 목적으로 한다. 본 연구를 통하여 작업공간 국부환기 뿐만 아니라 화재연 제어를 위한 방재팬을 개발하였다. 방재팬은 풍관없이 가동되며 작업공간내 유해물질의 희석 및 배기 기능을 갖추고 있으며 동시에 화재시 화재연 배기를 목적으로 한다. 본 논문은 개발된 방재팬과 기존 국부팬의 연결 운전을 통한 화재연의 배기효율 연구가 목적이다. 일련의 현장 실험 및 CFD분석을 통하여 맹갱도 작업공간내 방재팬의 화재연 배기효율을 분석하였으며 이를 위하여 SF6 추적가스를 이용한 공간내 기류 및 유해물질 유동을 검토하였다. 대단면 석회석 광산에서 수행한 현장실험과 CFD분석 결과를 비교한 결과, 갱내에서 가장 리스크가 큰 맹갱도 굴진 작업장에서 기존 국부팬 1대와 조합 운전하는 경우, 팬의 설치 위치 및 운전모드의 적절한 선택시에 효율적인 화재연 배기가 가능함을 보였다. 또한 CFD분석을 통하여 벤츄리효과에 의한 배기효율도 확인할 수 있었다. 팬 설치 위치 및 운전모드가 배기효율을 결정하는 가장 중요한 변수임을 보였다.

주물 공단 용해공정의 송풍기 및 백필터 관리 실태 (The Status of Maintenance of Exhaust Fans and Bag filters in Melting Processes in a foundry industrial complex)

  • 김태형;하현철;정춘화;서정윤;박승욱;양준호;이효우
    • 한국산업보건학회지
    • /
    • 제17권3호
    • /
    • pp.212-223
    • /
    • 2007
  • 18 Local exhaust ventilation systems in 10 melting companies located in an industrial complex were tested to know the status of maintenance. Test items were fan flowrates, fan static pressures, rotational speeds and differential pressures of bag filters. Only 22% of the tested fans has more than 80% flowrate efficiency. 44% of the fans has lower than 60% efficiency. The performance of the fans are not in a good status. For the fans with lower than 60% efficiency, the analysis shows that the lower flowrate might be caused by the degradation of fan performance. On the other hand, for the fan s with higher than 60% efficiency, the main cause of flowrate reduction might be too much pressure losses due to clogging of filter bags. The degradation of fans usually lead the reduction of hood capture efficiency, resulting in the increase of contaminant concentrations in workplace. To keep fans in good status, self inspections should be periodically conducted. This inspection should include the measurements of flowrate and pressures. The most important thing to be performed is the initial test of local exhaust ventilation system because the initial test data should be used to know the level of system degradation.

증발냉각시스템의 활용실태 및 냉방효과 (Actual State of Practical Use and Cooling Effect of Evaporative Cooling Systems)

  • 김문기;유인호;김기성
    • 생물환경조절학회지
    • /
    • 제8권4호
    • /
    • pp.281-287
    • /
    • 1999
  • 현장조사 결과 패드-팬 시스템의 경우 6개 농가 모두 사용하고 있었으며, 온실 내기온은 외부기온보다 2~5$^{\circ}C$ 낮았다. 이시스템의 냉방효율은 평균 77.4% 이었으며, 외부의 상대습도가 60%이하 일 경우 냉방 효율이 높았다. 포그 시스템의 경우 현장조사에서 9농가 중 6농가가 사용을 못할 정도로 많은 문제점이 발견되었다. 포그입경, 분무수량, 운영 방법등 개선해야 할 사항이 많았다. 실험온실의 경우도 노즐의 설치 위치와 제어방법에서 문제점이 발견되었다. 포그입자가 커 증발하지 못하고 대부분이 바닥과 차광망으로 낙하하였고, 지역 기상조건을 고려하지 못한 제어방법으로 냉방효과를 떨어뜨리고 있었다. 냉방효과를 높이가 위하여 노즐의 위치 선정, 제어방법에 대한 연구가 수행되어야 하며, 지역적 기상특성을 고려한 연구와 내부 습도를 낮게 유지하는 연구도 수행되어야 할 것이다.

  • PDF

실험적 해석을 통한 차량용 교류발전기 소음 저감 특성 연구 (A Study of AC Generator Noise Reduction Characteristics of Automobile Using Experimental Analysis)

  • 김대원;신중호
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.112-121
    • /
    • 1998
  • In this report, Experimental analysis for main factors and analyzing methods of electro-magnetic noise and no loading noise was conducted because of noise of AC generator, which is peripheral equipment by reduction of engine noise that would be the main cause of vehicle radiation noise. In addition, This is intended to suggest the noise reduction development basis of AC generator for actual fan and electro-magnetic noise by making-analyzing-testing it's sample.

  • PDF

일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방 (Greenhouse Cooling Using Air Duct and Integrated Fan and Pad System)

  • 남상운;김영식
    • 생물환경조절학회지
    • /
    • 제20권3호
    • /
    • pp.176-181
    • /
    • 2011
  • 온실의 한쪽 벽에 패드를 설치하고 반대쪽 벽에 팬을 설치하여 가동하는 팬 앤 패드 냉방 온실의 온도 경사 문제를 극복하기 위한 목적으로 일체형 팬 앤패드 시스템과 에어 덕트를 설치한 온실의 냉방 실험을 통하여 냉방성능을 분석하였다. 일체형 팬 앤 패드 증발냉각기의 효율은 1단 가동시 75.7%, 2단 가동시 88.6%로 나타나 대체로 우수한 냉각효율을 보이는 것으로 판단된다. 온실의 냉방성능 실험 결과 무차광 조건에서 온실 냉방 시스템을 가동할 경우 대조구 온실에 비해서 $5.7\sim7.6^{\circ}C$ 정도의 냉방효과가 있으며 차광 조건에서는 $7.4\sim9.7^{\circ}C$ 정도의 냉방효과가 있는 것으로 나타났다. 본 시스템을 적용할 경우 여름철 온실의 최고기온을 $37^{\circ}C$ 정도로써 외기온 대비 $5^{\circ}C$ 이내로 유지할 수 있으며, 적절한 차광을 실시할 경우에는 $33^{\circ}C$ 정도에 $2^{\circ}C$ 이내로 유지하는 것이 가능하여 고온기 작물재배에 큰 도움을 줄 수 있을 것으로 생각한다. 한편, 본 냉방 실험에서 온실의 온도 분포를 분석한 결과 18m 길이의 온실 내 최대 온도 편차는 차광시 $1.6\sim1.7^{\circ}C$, 무차광시 $2.3\sim2.7^{\circ}C$ 정도로 나타났다. Kittas 등(2003)과 Nam 등(2005)의 자료와 비교한 결과 본 연구에서 구상한 일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방시스템은 기존의 팬 앤 패드 냉방 온실의 최대 단점인 온도 편차를 40~50% 정도 개선할 수 있는 것으로 나타났다. 본 시스템은 자연환기 상태에서 가동할 수 있으므로 단동 온실에 적용하기가 쉬우며, 일체형 증발냉각기 출구로부터 온실 내 에어 덕트 시점까지의 연결 덕트 부분을 철저하게 단열하면 냉방성능을 더욱 향상시킬 수 있을 것으로 판단된다.

CFD 기법을 이용한 팬 앤 패드 냉방 온실의 온도경사 분석 (Analysis of Temperature Gradients in Greenhouse Equipped with Fan and Pad System by CFD Method)

  • 남상운;;김기성
    • 생물환경조절학회지
    • /
    • 제14권2호
    • /
    • pp.76-82
    • /
    • 2005
  • 팬 앤 패드 시스템은 국내외적으로 온실냉방에서 많이 이용되고 있으며, 그 효율도 매우 높지만 온실 내부의 온도분포가 불균일하고 설치비와 유지비가 많이드는 단점이 있다. 본 연구에서는 팬 앤 패드 시스템의 설계를 위한 자료를 제공할 목적으로 팬 앤 패드시스템 설치온실의 온도분포를 예측하기 위한 CFD 모델을 개발하였다. 개발된 모델은 실험 데이터를 이용하여 검증한 결과 실험치와 예측치가 잘 일치하여 모델의 응용이 가능할 것으로 판단되었다. 개발된 모델을 이용하여 온실 외부의 풍속과 풍향, 팬과 패드의 높이, 환기율에 따른 실내유속, 차광율 및 온실의 길이가 팬 앤 패드 냉방온실의 실내 온도경사에 미치는 영향을 검토하였다. 실내 온도경사를 감소시키기 위하여는 온실 설치 지역의 주풍향을 고려하고 팬과 패드의 높이가 적절해야 할 것으로 판단되었다. 시뮬레이션 결과 높은 환기율과 차광율은 팬 앤 패드 냉방 온실의 온도경사를 감소시키는데 기여할 수 있는 것으로 나타났다. 팬 앤 패드 냉방 온실의 온도를 적정 수준으로 유지시키기 위해서는 외부기상조건, 차광 및 환기율에 따라 온실의 길이를 제한해야 할 것으로 판단되었다. 개발된 CFD모델은 다양한 조건에서 팬 앤 패드 냉방온실의 설계와 평가에 유용한 도구가 될 수 있을 것으로 판단된다.

전폐형 유도전동기의 온도분포에 관한 수치 및 실험적 해석 (Numerical and experimental analysis of temperature distribution in TEFC induction motor)

  • 윤명근;고상근;한송엽;이양수
    • 대한기계학회논문집B
    • /
    • 제21권3호
    • /
    • pp.457-472
    • /
    • 1997
  • We studied the temperature distribution and heat transfer characteristics of TEFC induction motor with thermal network program for more efficient design and better cooling performance of it. We knew the characteristics and the windage loss of outer cooling fan from fan test experiments. Frame axial and peripheral heat transfer coefficients and endwinding heat transfer coefficient were measured by various model experiments and then, compared with other experimental results. Frame was the main heat transfer surface, load-side and fan-side surface were not thermally symmetric from the heat flux distribution analysis. Steady and unsteady temperature distributions were measured by real motor experiments. From the results, we knew that rotor surface temperature was higher than coil temperature and the hottest spot in the coil was loadside endwinding outside surface. We compared the simulation results with those of real motor test and the two results showed a good agreement.