• Title/Summary/Keyword: Main Air-ratio

Search Result 286, Processing Time 0.029 seconds

A Study on Flame Extinction in Oxymethane Combustion (메탄 산소 연소에 있어서 화염 소화에 대한 연구)

  • Kim, Tae Hyung;Kwon, Oh Boong;Park, Jeong;Keel, Sang-In;Yun, Jin-Han;Park, Jong Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.4
    • /
    • pp.34-41
    • /
    • 2015
  • Oxy-methane nonpremixed flames diluted with $CO_2$ were investigated to clarify impact of radiation heat loss and chemical effects of additional $CO_2$ to oxidizer stream on flame extinction. Flame stability maps were presented with functional dependencies of critical diluents mole fraction upon global strain rate at several oxidizer stream temperatures in $CH_4-O_2/N_2$, $CH_4-O_2/CO_2$, and $CH_4-O_2/CO_2/N_2$ counterflow flames. The effects of radiation heat loss on the critical diluent mole fractions for flame extinction are not significant even at low strain rate in nonpremixed $CH_4-O_2/N_2$ diffusion flame, whereas those are significant at low strain rate and are negligible at high strain rate (> $200s^{-1}$) in $CH_4-O_2/CO_2$ and $CH_4-O_2/CO_2/N_2$ counterflow flames. Chemical effects of additional $CO_2$ to oxidizer stream on the flame extinction curves were appreciable in both $CH_4-O_2/CO_2$ and $CH_4-O_2/CO_2/N_2$ flames. A scaling analysis based on asymptotic solution of stretched flame extinction was applied. A specific radical index, which could reflect the OH population in main reaction zone via controlling the mixture composition in the oxidizer stream, was identified to quantify the chemical kinetic contribution to flame extinction. A good correlation of predicted extinction limits to those calculated numerically were obtained via the ratio between radical indices and oxidizer Lewis numbers for the target and baseline flames. This offered an effective approach to estimate extinction strain rate of nonpremixed oxy-methane flames permitting air infiltration when the baseline flame was taken to nonpremixed $CH_4-O_2/N_2$ flame.

Quantitative Analysis of Snow Particles Using a Multi-Angle Snowflake Camera in the Yeongdong Region (영동지역에서 눈결정 카메라를 활용한 눈결정의 정량 분석)

  • Kim, Su-Hyun;Ko, Dae-Hong;Seong, Dae-Kyung;Eun, Seung-Hee;Kim, Byung-Gon;Kim, Baek-Jo;Park, Chang-Geun;Cha, Ju-Wan
    • Atmosphere
    • /
    • v.29 no.3
    • /
    • pp.311-324
    • /
    • 2019
  • We employed a Multi-Angle Snowflake Camera (MASC) to quantitatively analyze snow particles at the ground level in the Yeongdong region of Korea. The MASC captures high-resolution photographs of hydrometeors from three angles and simultaneously measures fallspeed. Based on snowflake images of the several episodes in 2017 and 2018, we derived statistics of size, aspect ratio, orientation, complexity, and fallspeed of snow crystals, which generally showed similar characteristics to the previous studies in other regions of the world. Dominant snow crystal habits of January 22, 2018 generated by northerly were melted aggregates when 850 hPa temperature was about $-6{\sim}-8^{\circ}C$. Average fallspeed of snow crystals was $1.0m\;s^{-1}$ though its size gradually increased as temperature decreased. Another snowfall event (March 8, 2018) was driven by the baroclinic instability as accompanied with a deep trough. Snow crystal habits were largely rimed aggregates (complexity ~1.8) and melting particles of dark images. Meanwhile, in the extreme snowfall event whose snow rate was greater than $10cm\;hr^{-1}$ on January 20, 2017, main snow crystals appeared to be heavily rimed particles with relatively smaller size when convective clouds developed vertically up to 9 km in association with tropopause folding. MASC also could successfully measure a decrease in snow crystal size and an increase in riming degree after AgI seeding at Daegwallyeong on March 14, 2017.

Properties of Temperature Reduction of Cooling Asphalt Pavements Using High-Reflectivity Paints (고반사 도료를 사용한 차열성 아스팔트 도로포장의 온도저감특성)

  • Hong, Chang Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.317-327
    • /
    • 2013
  • Air pollution and artificial heat of urban areas have caused the urban heat island in which asphalt pavements absorb solar heat during the daytime and release the heat at night. Hence, in order to improve the environment of urban areas, it is necessary to examine cooling pavements that can reduce heat on road pavements in urban areas. The application of temperature insulation paints on road pavements require to reduce black brightness for visibility, to increase the reflection rate of infrared light and minimize the reflection rate of visible light. In the study, one part of Acrylic-emulsion was used as a main binder, and the changes in black brightness and the changes of addition ratio (0%, 15%, 30%) of hollow ceramics, as well as kinds of paints (carbon black pigment, mixed mineral pigment) were selected as the main experimental factors. The performance of temperature reduction of cooling pavements was analyzed through the reflection rate of spectrum, the reflection rate of solar heat, and the lamp test. Abrasion resistance, UV accelerated weather resistance, and sliding resistance were tested in real situations. In addition, the performance of heat reduction of testing pavements covered with high-reflection paints was analyzed by using an infrared camera. As the test results, when using mixed mineral paints and hollow ceramic of 30%, the reflection rate of spectrum was 43% in the area of near-infrared ray and 17% in the area of visible light at black brightness of $L^*$=42.89 and the reflection rate of solar heat was 27.5%. Total color difference was ${\Delta}E$=0.27 in the test of UV Accelerated Weather Resistance, indicating almost no changes in color. BPN was more than 53 when scattering #2 and #4 silica sand of more than $0.12kg/m^2$. In Taber's abrasion resistance test, abrasion loss was up to 86.4mg at 500 rotations. The performance of heat reduction was evaluated using an infrared camera at the test section applying high-reflection paints to asphalt pavements, in which the results showed that the temperature was reduced by $12.7^{\circ}C$ on CI-30-40 cooling pavements ($L^*$=38.76) and by $14.2^{\circ}C$ on CI-30-60 cooling pavements ($L^*$=57.12).

Evaluation of Image Quality in Micro-CT System Using Constrained Total Variation (TV) Minimization (Micro-CT 시스템에서 제한된 조건의 Total Variation (TV) Minimization을 이용한 영상화질 평가)

  • Jo, Byung-Du;Choi, Jong-Hwa;Kim, Yun-Hwan;Lee, Kyung-Ho;Kim, Dae-Hong;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.252-260
    • /
    • 2012
  • The reduction of radiation dose from x-ray is a main concern in computed tomography (CT) imaging due to the side-effect of the dose on human body. Recently, the various methods for dose reduction have been studied in CT and one of the method is a iterative reconstruction based on total variation (TV) minimization at few-views data. In this paper, we evaluated the image quality between total variation (TV) minimization algorithm and Feldkam-Davis-kress (FDK) algorithm in micro computed tomography (CT). To evaluate the effect of TV minimization algorithm, we produced a cylindrical phantom including contrast media, water, air inserts. We can acquire maximum 400 projection views per rotation of the x-ray tube and detector. 20, 50, 90, 180 projection data were chosen for evaluating the level of image restoration by TV minimization. The phantom and mouse image reconstructed with FDK algorithm at 400 projection data used as a reference image for comparing with TV minimization and FDK algorithm at few-views. Contrast-to-noise ratio (CNR), Universal quality index (UQI) were used as a image evaluation metric. When projection data are not insufficient, our results show that the image quality of reconstructed with TV minimization is similar to reconstructed image with FDK at 400 view. In the cylindrical phantom study, the CNR of TV image was 5.86, FDK image was 5.65 and FDK-reference was 5.98 at 90-views. The CNR of TV image 0.21 higher than FDK image CNR at 90-views. UQI of TV image was 0.99 and FDK image was 0.81 at 90-views. where, the number of projection is 90, the UQI of TV image 0.18 higher than FDK image at 90-views. In the mouse study UQI of TV image was 0.91, FDK was 0.83 at 90-views. the UQI of TV image 0.08 higher than FDK image at 90-views. In cylindrical phantom image and mouse image study, TV minimization algorithm shows the best performance in artifact reduction and preserving edges at few view data. Therefore, TV minimization can potentially be expected to reduce patient dose in clinics.

Comparison of Ventilation Efficiency in an Enclosed and Conventional Growing-Finishing Pig House (개방형과 무창형 육성비육돈사의 환기효율 비교)

  • Song, J.I.;Choi, D.Y.;Jung, J.W.;Yang, C.B.;Choi, H.L.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.459-468
    • /
    • 2004
  • An experiment was conducted to establish comparison of ventulation efficiency in an enclosed and conventional growing-finishing pig house. The main results of the experiment are as follows : In the established temperature was sustained at the level of summer 24.8${\sim}$29.1$^{\circ}C$, winter 17.9${\sim}$23.1$^{\circ}C$ during the experimental period of enclosed growing-finishing pig house, and conventional growing-finishing pig house was at the lovel of summer 24.7${\sim}$32.3$^{\circ}C$, winter 14.5${\sim}$18.2$^{\circ}C$ during the experimental period respectively. As for the results of dertimental gas(ammonia) concentration ratio analysis, while the conventional pig house sustained of summer 9.3${\sim}$16.9 mg/$\ell$ level, enclosed growing-finishing pig house sustained of summer 7.9${\sim}$16.1 mg/$\ell$, and the latter one is lower than that of the conventional growing-finishing pig house. Air flow rate on the floor level which is the low part of pen and the active area of pigs in the enclosed growing and finishing pig house during winter was measured at 0 to 0.87 m/s at the 0.01 to 2.73 m/s at the maximum ventilation efficiency. As for breeding pigs in summer, the pigs from the conventional pig house weighed 100.2kg, on the other hand, the pigs from enclosed growing-finishing pig house weighed 107.3 kg ; the differnce between the two kinds was about 7 kg. This was because the most adequate environment, which was not influenced by the exterior atmosphere, was offered to the pigs from enclosed growing-finishing pig house, and all of this could reduce pigs stress effectively.

Nutrient Recovery from Sludge Fermentation Effluent in Upflow Phosphate Crystallization Process (상향류 인 결정화공정을 이용한 슬러지 발효 유출수로 부터의 영양소 회수)

  • Ahn, Young-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.8
    • /
    • pp.866-871
    • /
    • 2006
  • The nutrient recovery in phosphate crystallization process was investigated by using laboratory scale uptlow reactors, adopting sequencing batch type configuration. The industrial waste lime was used as potential cation source with magnesium salt($MgCl_2$) as control. The research was focused on its successful application in a novel integrated sludge treatment process, which is comprised of a high performance fermenter followed by a crystallization reactor. In the struvite precipitation test using synthetic wastewater first, which has the similar characteristics with the real fermentation effluent, the considerable nutrient removal(about 60%) in both ammonia and phosphate was observed within $0.5{\sim}1$ hr of retention time. The results also revealed that a minor amount(<5%) of ammonia stripping naturally occurred due to the alkaline(pH 9) characteristic in feed substrate. Stripping of $CO_2$ by air did not increase the struvite precipitation rate but it led to increased ammonia removal. In the second experiment using the fermentation effluent, the optimal dosage of magnesium salt for struvite precipitation was 0.86 g Mg $g^{-1}$ P, similar to the mass ratio of the struvite. The optimal dosage of waste lime was 0.3 g $L^{-1}$, resulting in 80% of $NH_4-N$ and 41% of $PO_4-P$ removal, at about 3 hrs of retention time. In the microscopic analysis, amorphous crystals were mainly observed in the settled solids with waste lime but prism-like crystals were observed with magnesium salt. Based on mass balance analysis for an integrated sludge treatment process(fermenter followed by crystallization reactor) for full-scale application(treatment capacity Q=158,880 $m^3\;d^{-1}$), nutrient recycle loading from the crystallization reactor effluent to the main liquid stream would be significantly reduced(0.13 g N and 0.19 g P per $m^3$ of wastewater, respectively). The results of the experiment reveal therefore that the reuse of waste lime, already an industrial waste, in a nutrient recovery system has various advantages such as higher economical benefits and sustainable treatment of the industrial waste.

Clinical review of Typhoid Fever Patients (장티브스에 관한 임상적 관찰)

  • 최정신
    • Journal of Korean Academy of Nursing
    • /
    • v.6 no.1
    • /
    • pp.60-71
    • /
    • 1976
  • The author reviewed the medical records of 96 typhoid fever patients who were diagnosed, admitted, and treated at Sea grave Memorial Hospital from January 1 , 1973 through August 31, 1975. Diagnosis was determined by clinical observation, aerology and bacteriology, eighty patients were treated medically, the remaining 16 patients required surgical intervention. The following results were obtained: 1) The age distribution of the patients revealed that 33.3% wert between 10 and 19 years old 21.9% were between 20 and 29, and 19.8% were between 30 and 39. The majority of patients were from these more active age groups. Male to female sex ratio was 1.3 : 1 2) Seasonal distribution was observed. Most illness occurred in the summer and autumn month 5. 3) 84. 3%of the patients came from farm families. 4) Duration between onset and admission averaged 16.0 days. The group without compilations was admitted after an average of 15. 1 days; The group with complications was ad-matted after an average of 19.4 days. 5) Methods of treatment before admission were as follows: 10.4% at medical clinics, 61, 5% at pharmacies (antibiotics 47.9%, other. drugs 13.5%), 7.3% by herb medications, 20.8% had no treatment. 6) Main clinical symptoms were as follows: fever 93.8%, headache 47.9%, abdominal pain 47.9%, chills 38.5%, cough 36.5%, general weakness 26.0%, nausea e vomiting 24.0% and generalized pain 21.9%. 7) Temperature of patients on admission: 22.9% were 39f or more, 67.6% were between 37℃ and 38℃, and 9.4% were 37℃ or less. 8) Occurrence of intensional bleeding after onset of disease averaged 9.3 days; perforation occurred at an average of 19. 1 days. 9) Interval between onset of major complication and surgical intervention averaged 2.8 days. 10) Among the 68 patients who underwent the bacteriological test the positive rate was 44.1% (30). The positive ,ales to, each separate culture method were as follows: 20.4% in the blood culture, 40.4% in the stool culture and 6.7% in the urine culture. Among these bacteriological positive patients 15 patients had a negative results or less than 160 titer of vidal reaction. 11) The initial vidal test of the total group showed a counts of 160 titer or more in 60.4% and less than 160 titer in 39.6%, 12) W. B. C. Counts in the uncomplicated group indicated that 32.5% were 6,000/㎣ or less, 47.5% were between 6,000 and 10,000, arid 20.0% were 10,000/㎣ or more. In the complicated group, 37.6% were 6,000/㎣ or less, 25,0% were 6,000-10,000/㎣ and 37.6% were 10,000/㎣ or more. 13) Duration of hospital stay of the patients averaged 6.4 days in the uncomplicated group and 12.7 days in the complicated group. 14) Subdiaphragmatic free air simple X-ray was found in 91.7% of the perforated cases. 15) Duration of antibiotic therapy until an febrile state was attained averaged 4.8 days in the uncomplicated group and 6.5 days in the complicated group. 16) Operative procedures were as follows: one layer simple closure of their perforation with or without debasement in 56.3%, drainage only in 6.3%, small bowel resection with primary anastomosis in 18.8% , externalization in 6.3%, cholecystectomy in 6.3%, The clinical findings of this study suggest the following recommendations. According to Top's report; 1% of typhoid fever patients treated with chlorarnphenicol and 2% of patients treated with other drugs become chronic carriers. Therefore, importance should be given to the strict control of these carriers. Immunization, improvement of sanitation and living standards are all needed for the prevention and treatment of disease, but a more serious problem is a lack of knowledge on the part of patients and their families. Thus it is most urgent to enlighten the citizens about the transmission and hygiene related to contagious disease. Legal restriction of sale of antibiotics at drug stores without a physician's prescription is an urgent matter for public health administrators. An even more important nursing responsibility is the reemphasis on health education both in the clinical setting and in the home.

  • PDF

Comparison of the Low Potassium Dextran Solution and ET-Kyoto Solution in Rabbit Lung (토끼 폐장 분리관류 모형을 이용한 LPD 폐보존액과 ET-Kyoto 폐보존액의 비교)

  • Lim, Cheong;Kim, Kyung-Hwan;Kim, Young-Tae;Sung, Sook-Whan;Kim, Joo-Hyun
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1159-1166
    • /
    • 1997
  • For Improvement of lung preservation, many tripes of preservation solution were developed and tested. The aim of this study was to compare the effect of the most frequently used extracellular type pieservation solution (Low Potassium Dextran, LPD) with a newly developed trehalose containing extracellular type preservation solution(ET-Kyoto, ETK) on postischemic lung function. Twelve New-Zealand white rabbit lungs were harvested and studied on an isolated, blood-perfused model of lung function after 4 hours of cold ischemia at $10^{\circ}C$ In group I (n=6), lungs were preserved with 100 mL/kg of LPD solution; in group II(n=6), lungs were preserved with 100 mL/kg of ETK solution. A few minutes before flushing with preservation solutions, 20$\mu\textrm{g}$ of PGEI were injected into main pulmonary artery. Functions of the preserved lung were compared with PO2, PA pressure, t acheal air pressure, and drylwet ratio. The pulmonary efferent blood oxygen tension at the end of the 60-minute reperfusion period was higher in group II compacted with group I(486.5 $\pm$ 80.3 mmHg versus $432.5\pm82.9$ mmHg at FiO2 1.0, p-value = NS). The mean pulmonary arterial pressure was similar in both $groups.(33.7\pm2.2$ mmHg versus $35.5\pm2.0$ mmHg, p-value : NS). The peak inspiratory airway pressure was significantly lower in group 11(8.010.6 mmHg versus 11.8 $\pm$ 1.4 mmHg, p-value=0.02) The water content of the lung was lower in group II $(70.2\pm6.9%$ versus 78.5 $\pm6.1%),$ but not significant. These data demonstrate that a newly-developed trehalose-containing ET-Kyoto solution yield equal or slightly superior lung function after reperfusion compared with LPD solution.

  • PDF

Study on the Storage of Chestnut (밤 저장(貯藏)에 관(關)한 연구(硏究))

  • Yim, Ho;Kim, Choung-Ok;Shin, Dang-Wha;Suh, Kee- Bong
    • Korean Journal of Food Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.170-175
    • /
    • 1980
  • A mass production of chestnut necessiates the development of economic long-term storage method. The main objective of this study was to confirm the technical aspect of the chestnut storage method which was developed by two year project and to review the method of commercial application. The chestnut used for the experiments were separated in brine $(5.5{\sim}6.0^{\circ}\:B{\acute{a}}ume)$ into matured and unmatured lots and fumigated with $CS_2$ at a 5 $lb/27\;m^3$ level for $25{\sim}30\;hrs.$ The chestnuts were packed in wooden boxes with sawdust (50% moisture) in the ratio of 1 : 1 by volume. The boxes were stored in the cold room $(1{\pm}1^{\circ}C,\;85{\sim}95%\;RH)$ and the cellar ($0{\sim}10^{\circ}C$, controlled only by circulating night cool air). The results obtained were as follows: 1. Fully matured chestnut could be successfully preserved $8{\sim}9\;months$ at a l0% decay level in the cold room and $4{\sim}5\;months$ months in cellar. 2. Immatured chestnuts wire inferior to the matured in storage stability. At the maximum storage period, its storage life was two months shorter. 3. The heat transfer equation of piled chestnuts with sawdust can be suggested as $T_{\infty}-T_0=(T_{\infty}-T_0){\cdot}10^{-t/320}$ and j and $f_h$ values were 1 and 320 min, respectively. 4. The chestnuts in the package of storage unit had longer shelf life than naked chestnut during the retail distribution at ambient temperature.

  • PDF

A Comparative Study of Landscape Characteristics on Bridges in Palaces of Korea and China - Focusing on the Chosun Dynasty and Ming and Qing Dynasties - (한국과 중국의 궁궐 내 교량에 관한 경관특성 비교 연구 - 조선시대와 명·청시대를 중심으로 -)

  • Zhang, Fu-Chen;Lee, Ai-Ran
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.1-12
    • /
    • 2019
  • A bridge is a structure constructed on water or in the air for convenient passage. Compared to other buildings, the building materials and structures of bridge required unique functions to cross the space. It depends on the productivity of the building, the level of science and technology, and the ecological environment of the building site. Also, it has important relationship with functions such as politics, military, economy, and life. Most of the academic research on bridges is focused on research in the field of bridge-building technology, so the study on the landscape aesthetics and history of bridges is lacking. Against this backdrop, the study will be valuable as a accumulation of both countries' understanding of bridge types, history and culture, as well as technical and aesthetic data, by analyzing the bridges located within the palaces of Korea and China. The research method is to analyze the bridge through field survey and literature analysis.. First, the bridges of royal palace of Korea and China are to be classified quantitatively as physical shapes, landscapes, and decorations by comparing the materials, forms, landscapes, and decorative culture of bridges. Second, characteristics, common points, and differences are extracted by classifying bridges of both countries. Also, the results are discussed based on the physical environment or cultural background. This would be worth cross-referencing in the building technology and aesthetics of the two countries. For the first important characteristics of result, main materials of Korean and Chinese palaces are stone. However, the bridge in China's royal palaces is also focused on wood. Second, in terms of form, the bridges in the royal gardens of Korea and China are all based on the beam bridge. However, the specific form, ratio, style of the beam bridge, and airspace of arched bridge are very different. Third, most of the connection methods are focused on the over bridge. It values the convergence with the surrounding landscape. Due to the difference in the area and location of water, the bridge in the Korean palace is more focused on the convergence of the surrounding buildings and plants, while the bridge in the Chinese palace is more concerned about the harmony of hydration. Fourth, the decoration places importance on the artistry and aesthetics of both the bridges in Korea and China. There is a difference in style in the same type of decoration due to culture.