• Title/Summary/Keyword: Main Air-ratio

Search Result 286, Processing Time 0.033 seconds

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

Patterns of the main VOCs concentration in ambient air around Shiwha Area (시화공단 지역의 주요 휘발성물질 농도 분포 특성)

  • Byeon, Sang-Hoon;Lee, Jeong-Geun;Kim, Jeong-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • In this study, we investigated the concentrations of volatile organic compounds (VOCs) in Shiwha area and compared the characteristics of both industrial area and residential area. The passive samplers were set 6 times each for a month in 21 locations at industrial and residential area to obtain 6 VOCs including benzene, trichlorobenzene, toluene, ethyl benzene, xylene and stylene. Above all, toluene was the most abundant VOCs in the ambient air both in industrial and residential area. Average TVOC concentration of industrial area was 1.86 times higher than that of residential area, and it was greatly reduced in winter compared with summer. Furthermore, the average BTEX concentrations showed that all concentrations of industrial area were 1.94~5.39 times higher than those of residential area except benzene which were similar to each other. In winter, the concentration of ethyl benzene and xylene were significantly decreased by comparing with summer: but benzene concentrations were increased. Also, BTEX relative ratio was as follows: toluene>benzene>ethylbenzene>xylene. Correlation coefficients among VOCs were confirmed that VOCs in ambient air of industrial area were generally more related to each other than that of residential area. On the whole, the concentrations of VOCs in industrial area were higher, and it seems to be potential that industrial area affects the distribution of VOCs to residential area.

Effects of Ventilation Systems on Interior Environment of the Growing-finishing Pig House in Korea (육성$\cdot$비육돈사 내에서 환기형태별 환경조사 연구)

  • Song J. I.;Yoo Y. H.;Jeong J. W.;Kim T. I.;Choi H. C.;Kang H. S.;Yang C. B.;Lee Y. Y.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • An experiment was conducted to establish comparison of ventilation efficiency in an enclosed and conventional growing-finishing pig house. The experimental pigs were in winter and summer. The main results of the experiment are as follows : Then the air from planar slot inlet the pig house flow out through the sidewall outlet operated by exhaust fan(Gl). The second structure has an air input through the circular duct inlet are plated side the juncture of the entering wall and the air into the pig house flow out through the chimney and pit outlet are operated by exhaust fan(G2). Through the air into relay fan the pig house flow out through the curtains in sidewall(G3). Similarly, air comes in through the circular duct inlet are placed the air into the pig house flow out through the curtains in sidewall (G4). Air flow rate on the floor level which is the low part of pen and the living area of pigs in the G2 and G4 system during winter was measured at 0.2 to 0.3 m/s at the 0.5 to 0.6 m/s at the maximum ventilation efficiency. As for the results of detrimental gas(ammonia) concentration ratio analysis, while G2 and G4 system sustained of summer 13.3 $\~$ 16.6 ppm, winter 14.0 $\~$ 14.6 ppm level, Gl and G3 system sustained of summer 14.6 $\~$ 20.3 ppm, winter 20.3 $\~$ 25.0 ppm, and the latter one is lower than that of the G1 and G3 system.

  • PDF

Compression of Multispectral Images (멀티 스펙트럴 영상들의 압축)

  • Enrico Piazza
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.1
    • /
    • pp.28-39
    • /
    • 2003
  • This paper is an overview of research contributions by the authors to the use of compression techniques to handle high resolution, multi-spectral images. Originally developed in the remote sensing context, the same techniques are here applied to food and medical images. The objective is to point out the potential of this kind of processing in different contexts such as remote sensing, food monitoring, and medical imaging and to stimulate new research exploitations. Compression is based on the simple assumption that it is possible to find out a relationship between pixels close one each other in multi-spectral images it translates to the possibility to say that there is a certain degree of correlation within pixels belonging to the same band in a close neighbourhood. Once found a correlation based on certain coefficient on one band, the coefficients of this relationship are, in turn, quite probably, similar to the ones calculated in one of the other bands. Based upon this second observation, an algorithm was developed, able to reduce the number of bit/pixel from 16 to 4 in satellite remote sensed multi-spectral images. A comparison is carried out between different methods about their speed and compression ratio. As reference it was taken the behaviour of three common algorithms, LZW (Lempel-Ziv-Welch), Huffman and RLE (Run Length Encoding), as they are used in common graphic format such as GIF, JPEG and PCX. The Presented methods have similar results in both speed and compression ratio to the commonly used programs and are to be preferred when the decompression must be carried out on line, inside a main program or when there is the need of a custom made compression algorithm.

  • PDF

Field Applicability Evaluation of SB Latex-Modified Concrete for Concrete Bridge Deck Overlay (콘크리트 교면 덧씌우기를 위한 SB 라텍스개질 콘크리트의 현장적용성 평가)

  • Yun, Kyong-Ku;Lee, Joo-Hyung;Hong, Chang-Woo;Kim, Ki-Hyun;Kim, Tae-Kyong
    • International Journal of Highway Engineering
    • /
    • v.3 no.4 s.10
    • /
    • pp.93-103
    • /
    • 2001
  • This study focused on the field applicability evaluation of SB latex-modified concrete (LMC) for concrete bridge deck overlay using mobile mixer. The main experimental factors were water-cement ratio(31, 33, 35 37%), latex contents(0, 5, 10, 15, 20%), and fine aggregate ratio(55, 56, 57, 58%) in order to evaluate the workability, mechanical properties, and durability property of LMC. The slump loss, air content, compressive and flexible strength tests were used to evaluate LMC workability and strength properties. Also, the rapid chloride permeability test was used to evaluate the relative permeability of LMC. As a results, the LMC with enough workability and good quality was produced when it was mixed in field using mobile mixer, satisfying the target compressive strength and flexural strength. The required water-cement ratio of LMC for same workability when mixing with mobile mixer was less than that when mixing in laboratory. Increasing the amount of latex produced concrete with increased flexural strength by mobile mixer. The required cement-water ratios for same initial $19{\pm}3cm$ slump were 37% and 33% at laboratory and mobile mixer, respectively. The mobile mixer was accurately calibrated satisfying the required specification.

  • PDF

Comparison of Active and Passive Sampler for Determining Temperal and Spatial Concentration Assessment of the Main Volatile Organic Compounds Concentration in Shihwa Industrial Complex (시화산업단지에서 주요 휘발성유기물질의 시간적, 공간적 농도 파악을 위한 능동식과 수동식 시료채취기 비교)

  • Byeon, Sang-Hoon;Choi, Hyeon-Il;Moon, Hyung-Il;Lee, Jung-Geun;Kim, Jung-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.790-796
    • /
    • 2011
  • In this study, we measured the concentrations of volatile organic compounds (VOCs) in Shiwha area by using active and passive sampler. We did a comparative analysis of the characteristics of the active sampler and passive sampler. In the case of the passive sampler, the average TVOC concentration of the industrial area was 1.86 times higher than that of the residential area. In the case of the active sampler, the average TVOC concentration of the industrial area was 1.07 times higher than that of the residential area. When using the passive sampler, the concentration of VOCs in the industrial area was noted to be higher than the concentration found in the residential area. However, when we used the thermal desorption tube, the concentration of residential area was higher rather than that of industrial area in some substances such as trichloroethylene, toluene, ethylbenzene, and xylene. Toluene was a larger percentage of the overall BTEX ratio. In case of the passive sampler, the relative ratio of toluene, ethylbenzene, and xylene was higher in the industrial area than in the residential area. In contrast in case of the thermal desorption tube, the ratio of these substances was higher in the residential area rather than in the industrial area. The passive sampling in this study showed an appropriate method to analyze the temporal and spatial concentrations of air contaminants. This assessment would prove to be useful for its observance of standards or epidemical study.

Composting Effectiveness of A Sundry System with A Bin-type Composter for Recyle of Animal Wastes (축분뇨처리를 위한 Bin형 부숙조- Sundry 시스템의 퇴비화효율 평가)

  • 최홍림;김현태;정영윤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.2
    • /
    • pp.92-103
    • /
    • 1993
  • A sunday system with a horizontal bin-type composter was constructed and operated to evaluate its composting performance for four days for each test in October, 1992. A sundry system is one of popular systems for composting livestock manure, of which main benefit is to utilize unlimited, clean, and free solar radiation. A rectangular concrete bin(composter) with dimension of 300cm(length) X90cm(width) X60cm(height) was bedded alternatively with four lanes of aeration pipes and heating pipes, and was insulated at three walls with 50mm styrofoam. Each aeration pipe of a diameter of 25mm had 4mm perforated holes at every 15cm longitudinally, and supplied air of about 2m$^3$/min to the composter to maintain aerobic condition . A stirrer rotating at 1 rpm made one round trip every 20 minutes on the conveying chain along the the length of the composter. Five tests (Test 1~Test 5) were implemented to evaluate the composting effectiveness of a sundry system with a horizontal bin-type composter. Treatments of two levels of the mixture ratio of swine manure and paper sludge cakes(manure : paper sludge cakes= 1 : 4 and 1 : 2) and two levels of the water content(W/C ; 70% and 50%) were made to test the significance of the physicochemical properties for decomposition of the mixture materials. Temperature, C/N ratio, water content, microbial activity of the composting materials were taken measurements to evaluate its performance with the lapse of composting time for tests. A small-scale sundry system with a bin-type composter did not appear to be an appropriate system for composting livestock manure. Since heat generation by the composting materials could not overcome heat loss due to areation in a small-scale composter, a proper thermal enviroment could not be maintained to propagate massively thermopilic microorganism relatively in a short period of time. Different from the result of Chol et al.(1992) 6), a temperature variation of the composting materials did not show the peak clearly and C/N ratio didn't lower with time as expected. Mesophilic microoragnism seemed to play an important role for decomposition of the mixture materials. A sundry system with a bin-type composter may be good for a large-scale livestock farm household which may produce enough animal manure. Therefore a decision should be made very carefully to choose a system for composting livestock waste.

  • PDF

Development of suitable substrate of Sparassis latifolia for bottle cultivation (꽃송이버섯 병재배 적합 배지 개발)

  • Gwon, Hee-Min;Lee, Yun-Hae;Choi, Jong-In;Jeon, Dae-Hoon;Lee, Yong-seon;Lee, Young-Soon;Kim, Jeong-Han
    • Journal of Mushroom
    • /
    • v.17 no.3
    • /
    • pp.126-131
    • /
    • 2019
  • This study sought to identify the optimum substrate composition for the stable bottle cultivation of Sparassis latifolia. The main substrate was fermented larch sawdust. Six nutrient sources were mixed at a maximum volume ratio of 20%. The fresh weight of fruit body was the highest at 128.5 g for GMSL69033 and 126.6 g for 'Neoul' in the treatments of beet pulp and corn flour in a volume ratio of 15:5. In addition, the total cultivation period was 94 days, which was shorter than that required for other treatments. The selected substrate characteristics were pH 4.7, C:N (carbon to nitrogen) ratio of 106:4, moisture content of 70%, and air filling porosity of 38%. We plan to develop new income items through research on mycelial incubation and fruit body growth conditions.

Effects of Physical Factors on Urban Surfaces on Air Quality - Chang Chun, China as an Example - (도시표면의 물리적 요소가 대기질에 미치는 영향 - 중국 창춘을 사례로 -)

  • Jin, Quanping;Kim, Tae Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.5
    • /
    • pp.1-11
    • /
    • 2021
  • The purpose of this study is to find out the main factors affecting air quality in urban physical space factors, and provide clues for environmental improvement. Nine monitoring stations in China's industrial city, Changchun, collected AQI concentration data from January 1, 2018 to December 31, 2019. This paper analyzes the types and distribution characteristics of urban physical facilities within a radius of 300m with the detection station as the center. The monitoring station is divided into three groups, and the difference in floating dust concentration among the three groups in different seasons is analyzed. The results show that AQI concentration is the highest in spring and winter, followed by summer, and the lowest in autumn. The place with the highest concentrations of AQI in spring are F (93.00), D (91.10), I (89.20), in summer are D (69.05), A (67.89), B (84.44), in autumn are I (62.80), G (60.84), D (53.27), D (53.27), in winter are I (95.82), H (95.60), f (94.04). Through SPSS analysis, it shows that the air index in a space with a diameter of 600 meters is related to forest land, grassland, bare land, water space, tree height, building area (average value), and building volume (average value). According to the statistical analysis results of spring and winter with the most serious pollution, forest land area (43,637m2, 15.44%) and water surface area (18,736m2, 6.63%) accounted for the majority, and group 1 (A, B, C) with the least average building area (448m2, 0.17%) and average building volume (10,201m2) had the lowest pollution concentration. On the contrary, group 2 (D, E, F) had the highest AQI concentration, with less or no woodland (1,917m2, 0.68%) and water surface area (0m2, 0%), and the highest average building area (1,056m2, 0.37%) and average building volume (17,470m3). It is confirmed that the characteristics of the area with the highest AQI concentration are that the more the site ratio of tree height above 12m, the smaller the site ratio of bare land, and the lower the pollution degree. On the contrary, the larger the area of bare land, the higher the pollution degree. By analyzing the characteristics of nine monitoring stations in Changchun, it can be seen that the air quality brought by the physical characteristics of urban space is closely related to the above factors.

A study of improving filtration efficiency through SiC whisker synthesis on carbon felt by CVD VS method

  • Kim, Gwang-Ju;Choe, Du-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.150-150
    • /
    • 2016
  • Mankind is enjoying a great convenience of their life by the rapid growth of secondary industry since the Industrial Revolution and it is possible due to the invention of huge power such as engine. The automobile which plays the important role of industrial development and human movement is powered by the Engine Module, and especially Diesel engine is widely used because of mechanical durability and energy efficiency. The main work mechanism of the Diesel engine is composed of inhalation of the organic material (coal, oil, etc.), combustion, explosion and exhaust Cycle process then the carbon compound emissions during the last exhaust process are essential which is known as the major causes of air pollution issues in recent years. In particular, COx, called carbon oxide compound which is composed of a very small size of the particles from several ten to hundred nano meter and they exist as a suspension in the atmosphere. These Diesel particles can be accumulated at the respiratory organs and cause many serious diseases. In order to compensate for the weak point of such a Diesel Engine, the DPF(Diesel Particulate Filter) post-cleaning equipment has been used and it mainly consists of ceramic materials(SiC, Cordierite etc) because of the necessity for the engine system durability on the exposure of high temperature, high pressure and chemical harsh environmental. Ceramic Material filter, but it remains a lot of problems yet, such as limitations of collecting very small particles below micro size, high cost due to difficulties of manufacturing process and low fuel consumption efficiency due to back pressure increase by the small pore structure. This study is to test the possibility of new structure by direct infiltration of SiC Whisker on Carbon felt as the next generation filter and this new filter is expected to improve the above various problems of the Ceramic DPF currently in use and reduction of the cost simultaneously. In this experiment, non-catalytic VS CVD (Vapor-Solid Chemical Vaporized Deposition) system was adopted to keep high mechanical properties of SiC and MTS (Methyl-Trichloro-Silane) gas used as source and H2 gas used as dilute gas. From this, the suitable whisker growth for high performance filter was observed depending on each deposition conditions change (input gas ratio, temperature, mass flow rate etc.).

  • PDF