Browse > Article
http://dx.doi.org/10.9711/KTAJ.2019.21.6.749

A study on the ventilation control method of road tunnel for small vehicles  

Ryu, Ji-Oh (Dept. of Mechanical and Automotive Engineering, Shinhan University)
Lee, Hu-Young (Dept. of ICT-Mechanical Engineering, Shinhan University)
Chang, Ji-Don (Dept. of ICT-Mechanical Engineering, Shinhan University)
Publication Information
Journal of Korean Tunnelling and Underground Space Association / v.21, no.6, 2019 , pp. 749-762 More about this Journal
Abstract
In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.
Keywords
Road tunnel for small cars; Ventilation system operation steps and control logic; Ventilation system consumption power;
Citations & Related Records
연도 인용수 순위
  • Reference
1 MOLIT (2011), 617 Ventilation System, Road Design Manual, Vol. 6, pp. 617-1-617-95.
2 Poole, G.F. (2000), "Predicting annual energy consumption for longitudinally ventilated road tunnels", Proceedings of the Aerodynamics and Ventilation of Vehicle Tunnels 10th International Symposium, Vol. 43, Boston, pp. 411-430.
3 Topis (2018), https://topis.seoul.go.kr/refRoom/openRefRoom_1.do
4 Yoo, J.O., Shin, H.J., Lee, D.H., Lee, Y.H. (2002a), "The study of operation mode of ventilation system in the longitudinal ventilation system tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 4, No. 4, pp. 343-353.
5 Yoo, J.O., Shin, H.J., Yoon, C.Y., Lee, D.H., Lee, Y. H. (2002b), "Development of dynamic simulation program for tunel ventilation", Proceedings of the 2002 Society of Air-conditioning and Refrigerating Engineers of Korea Summer Annual Conference, YongPyong, pp. 689-694.