• 제목/요약/키워드: Magnitude and Phase

검색결과 852건 처리시간 0.027초

탄성체로 인한 탄성파의 공명산란 (ELASTIC WAVE RESONANCE SCATTERING FROM AN ELASTIC CYLINDER)

  • 이희남
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.833-838
    • /
    • 2003
  • The problem of elastic wave resonance scattering from elastic targets is studied in this paper. A new resonance formalism to extract the elastic resonance information of the target from scattered elastic waves is introduced. The proposed resonance formalism is an extension of the works developed for acoustic wave scattering problems by the author. The classical resonance scattering theory computes reasonable magnitude information of the resonances in each partial wave, but the phase behaves in somewhat irregular way, therefore, is not clearly explainable. The proposed method is developed to obtain physically meaningful magnitude and phase of the resonances. As an example problem, elastic wave scattering from an infinitely-long elastic cylinder was analyzed by the proposed method and compared to the results by RST. In case of no mode conversion, both methods generate identical magnitude. However, the new method computes exact $\pi$ radian phase shills through resonances and anti-resonances while RST produces physically unexplainable phases. In case of mode conversion, in addition to the phase even magnitudes are different. The phase shifts through resonances and antiresonances obtained by the proposed method are not exactly $\pi$ radians due to energy leak by mode conversion. But, the phases by the proposed method show reasonable and intuitively correct behavior compared to those by RST.

  • PDF

자동동기장치 성능평가를 위한 3상 정밀파형발생기 개발 (3-Phase High Precision Sinusodial Signal Generator for Performance Measure of Autosyncronizer)

  • 정태진;차영호;박호철;천영식;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.478-480
    • /
    • 1998
  • We develops a simulator to evaluate the performance of the autosyncronizer. The autosyncronizer is used to automatically syncronize magnitude, frequency, and phase of 3 phase signals of generator with respect to those of the utility grid. This autosyncronizer needs to be evaluated its performance to prevent malfunctions. To do this, 3 phase signals of generator and the utility grid are simulated and signals of the generator should be changed by ouput of the autosyncronizer with high precision. In this paper, we uses TMS320C31 to generate high precision sinusoidal 3 phase signals using Table Lookup method. In this process, it is very desirable to control magnitude, frequency, and phase of the signal with high precision and this is achieved by appropriate interpolation method. The resulted signal is well controlled and has low THD and could be used to evaluate the performance of the autosyncronizer.

  • PDF

이차 선형 시불변 비최소 위상 시스템의 설정값 조정을 위한 새로운 슬라이딩 모드 제어 (A New Sliding Mode Control for Set-point Regulation of Second Order LTI Nonminimum Phase Systems)

  • 이하준;박철훈
    • 제어로봇시스템학회논문지
    • /
    • 제13권10호
    • /
    • pp.990-999
    • /
    • 2007
  • We deal with second order NMP(Non-Minimum Phase) systems which are difficult to control with conventional methods because of their inherent characteristics of undershoot. In such systems, reducing the undesirable undershoot phenomenon makes the response time of the systems much longer. Moreover, it is impossible to control the magnitude of undershoot in a direct way and to predict the response time. In this paper, we propose a novel two sliding mode control scheme which is capable of determining the magnitude of undershoot and thus the response time of NMP systems a priori. To do this, we introduce two sliding lines which are in charge of control in turn. One is used to stabilize the system and achieve asymptotic regulation eventually like the conventional sliding mode methods and the other to stably control the magnitude of undershoot from the beginning of control until the state meets the first sliding line. This control scheme will be proved to have an asymptotic regulation property. The computer simulation shows that the proposed control scheme is very effective and suitable for controlling the second order NMP system because it can decide the magnitude of undershoot in a direct and stable way and reduce the response time compared with the conventional ones.

보조권선의 전력제어에 따른 단상유도전동기의 특성비교 (A Characteristics of SPIM with Power Conversions of Auxiliary Winding)

  • 박수강;서강성;백형래;조금배;임양수;이성길;김동휘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1149-1151
    • /
    • 2002
  • In this paper, an auxiliary winding driving system of single-phase induction motors is described. Starting charateristics variations are obtained by controlling the auxiliary winding voltage magnitude and phase angle, while the motor's main winding is directly connected to the local utility. A variable auxiliary winding voltage phase angle is shown to yield significant torque control, providing starting and braking torque. The analysis includes the determination of the relationship between the auxiliary winding voltage phase angle and the phase angle difference between the main and auxiliary winding current. The paper proposed for adjusting an auxiliary winding voltage magnitude and phase angle. Experimental results of motor's starting characteristics with using the DC-AMP and PWM inverter for auxiliary winding power supply are shown. The drive is tested using a dynamometer to experimentally verify the results of the theory.

  • PDF

PIV기법을 이용한정사각실린더의 근접후류에 관한 연구 (III) - 위상평균유동장 - (A Study on the Near Wake of a Square Cylinder Using Particle Image Velocimetry (III) - Phase Average -)

  • 이만복;김경천
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1527-1534
    • /
    • 2001
  • Phase averaged velocity fields in the near wake region behind a square cylinder have been (successfully) obtained using randomly sampled PIV data sets. The Reynolds number based on the flow velocity and the vertex height was 3,900. To identify the phase information, we examined the magnitude of circulation and the center of peak vorticity. The center of vorticity was estimated from lowpass filtered vorticity contours (LES decomposition) adopting a sub-pixel searching algirithm. Due to the sinusoidal nature of firculation which is closely related to the instantaneous vorticity, the location of peak voticity fits well with a sine curve of the circulation magnitude. Conditionally-averaged velocity fields represent the barman vortex shedding phenomenon very well within 5 degrees phase uncertainty. The oscillating nature of the separated shear layer and the separation bubble at the top surface are clearly observed. With the hot-wire measurements of Strouhal frequency, we found thats the convection velocity changes its magnitude very rapidly from 25 to 75 percent of the free stream velocity along the streamwise direction when the flow passes by the recirculation region.

멀티로터 UAV 환경에서의 CNN 기반 복소 스펙트로그램 향상 기법 (CNN based Complex Spectrogram Enhancement in Multi-Rotor UAV Environments)

  • 김영진;김은경
    • 한국정보통신학회논문지
    • /
    • 제24권4호
    • /
    • pp.459-466
    • /
    • 2020
  • 멀티로터 UAV(Unmanned Aerial Vehicle)를 이용해서 수집한 음향 데이터는 모터나 프로펠러에서 발생하는 자체 소음이나 비행 중 발생하는 바람 소리 등으로 인해 음향 품질이 크게 손상되는 문제가 발생한다. 멀티로터 UAV 환경에서는 목표 음향의 크기뿐만 아니라 위상도 크게 손상되기 때문에 크기와 위상을 모두 고려해서 음향을 향상시킬 필요가 있다. 하지만 위상은 크기와 달리 구조적인 특징이 잘 나타나지 않으므로 향상시키는 것이 쉽지 않다. 따라서 본 연구에서는 크기와 위상을 모두 표현할 수 있는 복소 스펙트로그램을 기초로 잡음을 제거해서 목표 음향의 품질을 향상시키는 CNN 기반 복소 스펙트로그램 향상 방법을 제안한다.

시트와 바닥 진동의 위상차가 안락성에 미치는 영향을 평가하기 위한 수식의 제안 (Proposal of an Equation for the Evaluation of Discomfort of a Seated Human Body Due to the Differential Vertical Vibration at the Seat and the Floor)

  • 장한기
    • 한국소음진동공학회논문집
    • /
    • 제12권8호
    • /
    • pp.626-631
    • /
    • 2002
  • A modified equation for the evaluation of discomfort of a seated human body exposed to differential vibration at the seat and the floor was proposed in this paper. Through the review and analysis of the preceding studies, effect of phase difference between the seat and the floor vibration on discomfort were quantitatively identified. The phase effect was shown to be governed by not only phase difference between the two vibrations but both their frequency and the magnitude, which means the present equation for the evaluation of perceptual amount of vibration provided by ISO 2631-1 should be modified. The proposed equation was developed such that the correction function was multiplied to the present equation. The correction function consisted of three parts, each of them represented the effect by phase difference, frequency and vibration magnitude on discomfort respectively.

선형 및 비선형 부하 사용시 전류 및 부하불평형률에 대한 연구 (A Study on the Current & Load Unbalance Factor in using Linear & Nonlinear Load)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1291-1296
    • /
    • 2017
  • Single-phase and three-phase load can be used together in 3-phase 4-wire system. Single-phase and three-phase loads can be classified as linear loads without harmonics and nonlinear with harmonics. Single-phase linear loads are linear loads such as lamps and heat, and single-phase nonlinear loads are power converters such as rectifiers. It is recommended that the distribution of loads in the 3-phase, 4-wire distribution lines be evenly distributed within a certain range. However, harmonic currents generated in a nonlinear load flow on the neutral line and affect the phase current magnitude. The difference in the magnitude of the individual phase current due to the influence of the harmonic current present in the neutral line can produce a difference in current and load unbalance. In this study, current unbalance ratio and load unbalance ratio which can occur when a combination of linear and nonlinear loads are applied to 3-phase 4-wire distribution line are calculated.

A Research on the Magnitude/Phase Asymmetry Measurement Technique of the RF Power Amplifier Based on the Predistortive Tone Cancellation Technique

  • Choi, Heung-Jae;Shim, Sung-Un;Kim, Young-Gyu;Jeong, Yong-Chae;Kim, Chul-Dong
    • Journal of electromagnetic engineering and science
    • /
    • 제10권2호
    • /
    • pp.73-77
    • /
    • 2010
  • This paper proposes a novel memory effect measurement technique in RF power amplifiers(PAs) using a two-tone intermodulation distortion(IMD) signal with a very simple and intuitive algorithm. Based on the proposed predistortive tone cancellation technique, the proposed measurement method is capable of measuring the relative phase and magnitude of the third-order and fifth-order IMDs, as well as the fundamental signal. The measured relative phase between the higher and lower IMD signal for specific tone spacing can be interpreted as the group delay(GD) information of the IMD signal concerned. From the group delay analysis, we can conclude that an adaptive control of GD as well as the magnitude and phase is a key function in increasing the linearization bandwidth and the dynamic range in a predistortion(PD) technique.

On Formant Extraction Based on Transfer Function

  • Jiang, Gang-Yi;Park, Tae-Young;Mei Yu
    • The Journal of the Acoustical Society of Korea
    • /
    • 제18권2E호
    • /
    • pp.31-38
    • /
    • 1999
  • This paper focuses on extracting formants from transfer function, derived from linear prediction analysis of speech signal. The second derivative of the log magnitude spectrum of the transfer function, the first and third derivatives of the phase spectrum of the transfer function in the z-plane are discussed. Their resolutions of detecting formants are analyzed and some comparisons are given. Theoretical analyses and experimental results show that the third derivative of the phase spectrum decays more rapidly around the formant locations than the first derivative of the phase spectrum and the second derivative of the log magnitude spectrum. Compared with the second derivative of the log spectrum and the first derivative of the phase spectrum, the third derivative of the phase spectrum has higher resolution in frequency domain and provides more accurate formant extraction.

  • PDF