• Title/Summary/Keyword: Magnification of image

Search Result 191, Processing Time 0.027 seconds

A Study on the Usefulness of the New Foot Oblique Projection (새로운 발 사방향 검사법의 유용성에 관한 연구)

  • Kim, Min-Suk;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.443-449
    • /
    • 2021
  • In this study, the purpose is to present the foot inclination angle for realizing an image similar to that of the existing examination method and to present the clinical usefulness of the new examination method through comparison between the existing examination method and the newly designed standing foot oblique projection. A foot phantom was used, and the magnification of the image according to the angle was quantitatively evaluated by attaching a nut to the position of the cuboid of the phantom. The internal oblique image acquired using a 30° wedge was set as the standard image. And that image was compared with the images acquired by changing the angle of the foot from 20° to 65° at intervals of 5°. Image evaluation was performed by 3 radiological technologists, and qualitative evaluation using a Likert 5-point scale for evaluation items of true oblique view and quantitative evaluation of the value obtained by measuring the diameter of a nut in each image were performed as image evaluation. For data analysis, reliability analysis between the measure and comparative analysis of the average value for each angle were performed. The qualitative evaluation score for each image was 4.5 to 5 points for most questions in the case of the standard image. And 4 points or less for most questions in the images with a foot angle of 45° or less, and an evaluation score close to the standard image was obtained in the image of 50° or more. And in the quantitative evaluation, the diameter of the nut was measured to be 9.28~9.56 mm. The qualitative evaluation showed a reliability of 0.95~1.0 and the quantitative evaluation was 0.62. As a result of comparing and analyzing the average of the quantitative and qualitative average values for each angle image, the group with the average value most similar to the standard image was images obtained at 55° and 60°, and in the post-analysis, the images of both groups were the same group as the standard image(p<0.01). As a result of this study, it was found that the angle of inclination of the foot for realizing the image most similar to the existing image in the standing foot oblique projection is 55°~60°. In addition, if this test method is applied to the clinic, it is believed that it will help prevent safety accidents such as falls during the test and improve test efficiency by minimizing the movement of patients for the test.

QUADRUPLY-IMAGED QUASARS: SOME GENERAL FEATURES

  • Tuan-Anh, P.;Thai, T.T.;Tuan, N.A.;Darriulat, P.;Diep, P.N.;Hoai, D.T.;Ngoc, N.B.;Nhung, P.T.;Phuong, N.T.
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.6
    • /
    • pp.149-159
    • /
    • 2020
  • Gravitational lensing of point sources located inside the lens caustic is known to produce four images in a configuration closely related to the source position. We study this relation in the particular case of a sample of quadruply-imaged quasars observed by the Hubble Space Telescope. Strong correlations between the parameters defining the image configuration are revealed. The relation between the image configuration and the source position is studied. Some simple features of the selected data sample are exposed and commented upon. In particular, evidence is found for the selected sample to be biased in favor of large magnification systems. While having no direct impact on practical analyses of specific systems, our results have pedagogical value and deepen our understanding of the mechanism of gravitational lensing.

Measurement of 3-D Deformation by Using Holospeckle Interferometry (홀로스펙클 간섭법을 이용한 3차원 변형측정 연구)

  • 박승옥;권영하;유성규
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.12-15
    • /
    • 1990
  • Holospeckle interferometry, the combined technique of holographic interferometry and speckle photography, was applied to the measurement of 3-D contact deformation created by an indentor. This new tech$.$ nique makes possible to measure both in-plane and out-of-plane displacements from one photographic plate. In this study, the optical system based on image holography was set up. In order to enhance the size and the contrast of the speckle, a proper magnification and a low reference beam ratio was used as compared with the conventional holographic interferometry technique. This system shows the magnified and clear holographic interference fringe as well as Young's fringe patterns.tterns.

  • PDF

High Quality Volume Rendering Using the Empty Space Jittering and the Sampling Alignment Method (빈공간 교란과 샘플링 위치 정렬을 이용한 고화질 볼륨 가시화)

  • Kye, Heewon
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.7
    • /
    • pp.852-861
    • /
    • 2013
  • When users use medical volume rendering applications, selecting specific region of volume data and observing the region by magnification is a common process.As the wood-grain artifact is arise from the magnified image, the jittered sampling technique has been used to remove the problem. However, the jittered sampling leads to some noise along the volume edge. In this research, we reveal the reason of the noise, and present a solution. To remove the wood-grain artifact without the noise, we propose the empty space jittering and the sampling alignment method. Using these methods, we can produce high quality volume rendering images without noticeable time consuming.

The Development of adaptive optical dimension measuring system (적응형 광학 치수 측정 장치 개발)

  • 윤경환;강영준;백성훈;강신재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.690-695
    • /
    • 2004
  • A new dimension measuring method for the measurement of diameter of an object has been developed using laser triangulation. The 3-D data of an object was calculated from the 2dimensional image information obtained by the laser stripe using the laser triangulation. The system can measure the diameter of hole not only in a normal plane but also in an incline plane. We can experiment with magnification that is optimized according to size of object using zoom lens. In this paper, the theoretical formula and calibration of the system were described. The measuring precision of the system was investigated by experiment.

  • PDF

Talbot Interferometry for Measuring the Focal Length of a Lens without Moiré Fringes

  • Lee, Sukmock
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.165-168
    • /
    • 2015
  • A simple method to determine the focal length of a lens using the Talbot image is presented. This method uses only one grating, requiring neither Moir$\acute{e}$ fringe analysis nor the angle between the gratings. The original Fourier transform was used to access the spectrum beyond the limitation set of the usual fast Fourier transform to determine the (de)magnification accurately enough to be used for the focal length. A set of Talbot images simulated numerically with the Fresnel diffraction integral was used to demonstrate the method. For focal lengths between 5550 mm and 5650 mm, the mean difference between the focal lengths determined from the Talbot images and the true values was 3.3 mm with the standard deviation of the difference being 3.8 mm. The true focal lengths can be recovered with an accuracy of 0.06%.

Measurement Resolution of Edge Position in Digital Optical Imaging

  • Lee, Sang-Yoon;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.49-55
    • /
    • 2000
  • The semiconductor industry relies on digital optical imaging for the overlay metrology of integrated circuit patterns. One critical performance demand in the particular application of digital imaging is placed on the edge resolution that is defined as the smallest detectable displacement of an edge from its image acquired in digital from. As the critical feature size of integrated circuit patterns reaches below 0.35 micrometers, the edge resolution is required to be less than 0.01 micrometers. This requirement is so stringent that fundamental behaviors of digital optical imaging need to be explored especially for the precision coordinate metrology. Our investigation reveals that the edge resolution shows quasi-random characteristics, not being simply deduced from relevant opto-electronic system parameters. Hence, a stochastic upper bound analysis is made to come up with the worst edge resolution that can statistically well predict actual indeterminate edge resolutions obtained with high magnification microscope objectives.

  • PDF

Analysis of Spray Characteristic for 3-Component Mixed Fuel (3 성분 혼합연료의 분무특성 해명)

  • Myong, Kwang-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.8
    • /
    • pp.589-595
    • /
    • 2009
  • The instability wave formed near nozzle region grows to vortex with large scale in downstream region of spray. It plays an important role in the fuel-air mixing, combustion process and engine exhaust emissions in direct injection diesel engine. The objective of this study is to analyze effect of variant parameters (injection pressure, ambient gas density, etc.) and fuel properties on spray instability near nozzle region. Spray structure near nozzle region was investigated using a magnification photograph. A pulsed Nd-YAG laser was used as a light source, and image was taken by CCD camera. The following conclusions are drawn from this experimental analysis. In low ambient density, the effect of fuel properties on spray instability near nozzle region is dominant. In high ambient density, the effect of ambient gas on spray instability near nozzle region is dominant. High jet velocity has strong influence on spray instability.

Image Magnification using Fuzzy Method (퍼지 기법을 이용한 영상 확대)

  • Cho, Seung-Gun;Lee, Ju-Hwa;Woo, Young-Woon;Kim, Kwang-Baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.209-212
    • /
    • 2010
  • 본 논문에서는 영상을 확대할 경우에 발생하는 영상의 품질 저하를 최소화하기 위하여 원본 영상 픽셀과 확대된 결과 영상 픽셀 간의 명암도 차이와 보간 수행시 적용되는 가중치 값을 퍼지 기법에 적용하여 영상을 확대하는 방법을 제안한다. 제안된 방법은 기존의 양선형 보간법으로 도출된 결과 영상 픽셀과 원본 영상 픽셀 간의 명암도 차이와 보간 수행시 네 개의 픽셀 값에 곱하게 되는 가중치 값을 퍼지 소속 함수에 적용하여 원본 영상의 픽셀 정보와 가장 근접한 특징을 가진 확대된 결과 영상의 픽셀 정보를 최종적으로 도출한다. 제안된 방법을 실험한 결과, 기존의 양선형 보간법에 비해 영상 확대시, 발생하는 문제점인 흐림 현상이 상대적으로 감소하여 영상의 품질이 개선되는 것을 확인하였다.

  • PDF

Hardware Design for the Control Signal Generation of Electron Optic by Focal Length (Focal length에 의한 전자 렌즈의 제어 신호 생성을 위한 하드웨어 설계)

  • Lim, Sun-Jong;Lee, Chan-Hong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.96-100
    • /
    • 2007
  • Condenser lens and objective lens are used to demagnify the image of the crossover to the final spot size. In lens, electrons are focused by magnetic fields. This fields is fringing field. It is important in electron focusing. Electron focusing occurs the radial component field and axial component field. Radial component produces rotational force and axial component produces radial force. Radial force causes the electron's trajectory to curve toward the optic axis and corss it. Focal length decreases as the current of lens increases. In this paper, we use the focal length for desiging the hardware of lens current control and present the results.