• Title/Summary/Keyword: Magnification mechanism

Search Result 21, Processing Time 0.037 seconds

Analysis of Multiple Displacement Magnification Mechanism in Ultraprecision Nano Stage (초정밀 나노 스테이지에서의 다중 변위 확대 기구 해석)

  • Min K.S.;Choi W.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1273-1276
    • /
    • 2005
  • A displacement magnification mechanism is usually employed in a nano-positioning stage to achieve a large stage motion. A lever mechanism is the most widely used displacement magnifying mechanism. For more large stage motion, double or multiple lever mechanisms can be used. In this case, a more accurate analysis model is needed. This study proposes a more reasonable analysis model for a multiple lever mechanism based on the single lever mechanism model. This paper describes that the high equivalent stiffness of the lever is the most important factor reducing the magnification ratio of the lever mechanism through increasing the deflection of the link and including the axial displacement of the pivot.

  • PDF

A Study on the Displacement Magnification Mechanism of Two-Lever System using Flexure Hinge (유연 힌지를 이용한 이중레버 시스템의 변위증폭 메카니즘에 관한 연구)

  • Jea, Wone-Soo;Ye, Sang-Don;Min, Byeong-Hyeon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.2
    • /
    • pp.60-65
    • /
    • 2008
  • The high-technology industries including a semi-conductor and an information communication need an ultra-precision technology from the technological points of view. Nano technology based on an ultra-precision technology is being studied to overcome the delicate technology that may occur in the semi-conductor fields. Then, the transferring equipment with high resolution and long displacement becomes an important technology. The goal of this study is to analyze the displacement magnification mechanism driven by piezoelectric actuator which has high resolution and fast response characteristics using flexure hinge with the merits of soft displacement, negligible back-lash and stick-slip, and no-lubrication. The analyses to reduce the magnification losses occurred during the magnification process are performed using ANSYS software based on FEM. The five design variables such as arm thickness, thickness of hinge, radius of hinge, length of input side at the 1st lever and magnification ratio of 1st lever are optimized to induce the maximum magnification ratio using Taguchi method.

  • PDF

Development of the Precision Positioning Mechanism by Nano Displacement Magnification Device (나노 변위확대기구의 정밀위치결정기구에 관한 연구)

  • Park, Chang-Yong;Kweon, Hyun-Kyu;Zhao, Zhijun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.1
    • /
    • pp.97-103
    • /
    • 2013
  • A new precision positioning mechanism for stage was been developed by Displacement Magnification Device(DMD) in this paper. The DMD was composed of the beam and multilayer piezoelectric actuators. The theoretical and experimental analysis of DMD to enlarge displacement more then 50times were discussed. And the 2-axis stage by using displacement amplification apparatus was added in the new DMD, and it was able to do it through finite element analysis and experiment. As the results, the magnification of DMD can be obtained about $100{mu}m$ displacement to the 10V input voltage($1.5{mu}m$). And the about 50nm of linearity error in the $30{mu}m$ measurement range and 20times of the amplification in displacement can be measured. In addition, the experimental results are confirmed the possibility of millimeter displacement characteristics and correspond to finite element analysis results.

Design and Control of Jetting Dispenser Driven by Piezoelectric Actuator (압전 작동기로 구동되는 젯팅 디스펜서의 설계 및 제어)

  • Choi, Min-Kyu;Nguyen, Quoc-Hung;Yun, Bo-Young;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1165-1171
    • /
    • 2006
  • This paper presents a new type of jetting dispenser for the integrated circuit (IC) fabrication and surface mount technology The proposed system is featured by the piezoelectric actuator and hydraulic magnification device. After describing structural component of the dispensing mechanism and its operation principle, both the fluid modeling and the hydraulic magnification modeling are undertaken with a lumped-parameter method based on the analogy of the fluid system and mechanical system. A mathematical governing equation is then derived by integrating the fluid model with the mechanical model of the driving piston and piezoelectric actuator. Subsequently, in order to achieve a desired dispensing amount, control algorithm adjusting duty cycle of the driving voltage is synthesized and control responses are presented in time domain.

Design and Control of Jetting Dispenser Driven by Piezoelectric Actuator (압전 작동기로 구동되는 젯팅 디스펜서의 설계 및 제어)

  • Choi Min-Kyu;Nguyen Quoc Hung;Yun Bo-Young;Choi Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.428-433
    • /
    • 2006
  • This paper presents a new type of jetting dispenser for the integrated circuit(IC) fabrication and surface mount technology. The proposed system is featured by the piezoelectric actuator and hydraulic magnification device. After describing structural component of the dispensing mechanism and its operation principle, both the fluid modeling and the hydraulic magnification modeling are undertaken with a lumped-parameter method based on the analogy of the fluid system and mechanical system. A mathematical governing equation is then derived by integrating the fluid model with the mechanical model of the driving piston and piezoelectric actuator. Subsequently, in order to achieve a desired dispensing amount, control algorithm adjusting duty cycle of the driving voltage is synthesized and control responses are presented in time domain.

  • PDF

Rotating-Gantry-Based X-Ray Micro-Tomography System with the Sliding Mechanism Capable of Zoom-In Imaging

  • Cho, Min-Hyoung;Lee, Dong-Hun;Han, Byung-Hee;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.107-113
    • /
    • 2008
  • We introduce a rotating-gantry-based x-ray micro-tomography system to be used for small animal imaging studies. It has the zoom-in imaging capability for high resolution imaging of a local region inside the animal subject without any contrast anomalies arising from truncation of the projection data. With the sliding mechanism mounted on the rotating gantry holding the x-ray source and the x-ray detector, we can control the magnification ratio of the x-ray projection data. By combining the projection data from the large field of view (FOV) scan of the whole animal subject and the projection data from the small FOV scan of the region of interest, we can obtain artifact-free zoomed-in images of the region of interest. For the acquisition of x-ray projection data, we use a $1248{\times}1248$ flat-panel x-ray detector with the pixel pitch of 100 mm. It has been experimentally found that the developed system has the spatial resolution of up to 121p/mm when the highest magnification ratio of 5:1 is applied to the zoom-in imaging. We present some in vivo rat femur images to demonstrate utility of the developed system for small animal imaging.

The design methods of Infrared Camera with Continuous zoom

  • Son, Seok-Hyeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.19-26
    • /
    • 2016
  • In this paper, we propose an efficient design method for a thermal camera with continuous zoom based on the research and manufacturing experience of the thermal camera. In addition, it is divided into system design method, optical design method, mechanical design method, and electronic design method. First, we propose an effective NUC compensation method and a lens-specific sensitivity design method in terms of system. Second, we propose a zoom trajectory design method considering the temperature effect on the optical aspect. Third, it suggests the minimization of optical axis shaking between magnification conversion in terms of mechanism. Finally, we propose a lens-specific temperature compensation method and a speed conversion algorithm according to the zoom interval as an electronic aspect.

Crack Growth and Debonding Behaviors of the Pre-cracked RC Beams Repaired with Carbon Fiber Sheets (사전균열로 손상된 RC 보의 탄소섬유시트 보수 후의 균열성장 및 박락거동)

  • Kim, Chung Ho;Ko, Sin Woong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.121-129
    • /
    • 2006
  • This study look into the mechanisms of growth and magnification of the cracks and delamination in the pre-cracked RC beams repaired with carbon fiber sheets. The experimental parameters were loading type, loading speed and crack. In the experiments, it was confirmed that a failure of beams began with development and propagation of the stepped delamination in the below the loading point due to the rapid change of shear force, but mechanisms of the failure were not influenced with loading type, loading speed and pre-cracks. Particularly, in the case of beams having the pre-cracks, growth of crack concentrated at the special crack below the loading point and led to failure of the beam by delamination due to magnification of crack.

Autofocusing Mechanism of a Triple-Magnification Infrared System (3중 배율 적외선 영상 장비의 자동 초점 조절 방안)

  • Jung, Hyojung;Jeong, Suseong;Yang, Yunseok;Lee, Yongchun;Han, Jeongsu
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.314-320
    • /
    • 2020
  • The optics used in an infrared imaging system has a strong refractive-index change according to temperature, so an autofocus control function is essential for a military infrared imaging system with a wide operating-temperature range. In this study, we design a triple-magnification infrared imaging system, and to compensate for the change in refractive index according to temperature we measure the change in the lens focus according to temperature. The autofocus control function was implemented by using the measured movement amount, and we could obtain an image with satisfactory resolution performance over a wide range of operating temperatures.

A Study on Analysis of Breakup Mechanism of Vaporizing Fuel Droplet in High Temperature and Velocity Air Stream (고온고속류에서 기화를 고려한 연료액적의 분열(Breakup)기구 해석에 관한 연구)

  • Kim, K.C.;Hwang, S.S.
    • Journal of ILASS-Korea
    • /
    • v.3 no.3
    • /
    • pp.1-13
    • /
    • 1998
  • In this study, an experimental study was performed to investigate the breakup mechanism of vaporizing droplet. A well-controlled experimental apparatus was used to study breakup mechanisms of a monodisperse stream of drops injected into a transverse high temperature and velocity air stream. The experiments gave information$ about the microscopic structure of the liquid drop breakup process, drop breakup regimes, and drop trajectories in high temperature flow region. The breakup time, drop acceleration and wavelength of surface instability wave were measured from a high-magnification and double spark photography. The two instability theories, i.e., Kelvin-Helmholtz instability and Rayleigh-Taylor instability, were estimated by comparing the calculated data with the measurements. The results showed that the breakup time in high temperature flow condition is shortened because the surface tension is decreased by the increase of gas temperature.

  • PDF