• 제목/요약/키워드: Magnetizing inductance

검색결과 83건 처리시간 0.025초

Analysis and Implementation of a DC-DC Converter with an Active Snubber

  • Lin, Bor-Ren;Lin, Li-An
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.779-786
    • /
    • 2011
  • This paper presents a soft switching converter to achieve the functions of zero voltage switching (ZVS) turn-on for the power switches and dc voltage step-up. Two circuit modules are connected in parallel in order to achieve load current sharing and to reduce the size of the transformer core. An active snubber is connected between two transformers in order to absorb the energy stored in the leakage and magnetizing inductances and to limit the voltage stresses across the switches. During the commutation stage of the two complementary switches, the output capacitance of the two switches and the leakage inductance of the transformers are resonant. Thus, the power switches can be turned on under ZVS. No output filter inductor is used in the proposed converter and the voltage stresses of the output diodes is clamped to the output voltage. The circuit configuration, the operation principles and the design considerations are presented. Finally, laboratory experiments with a 340W prototype, verifying the effectiveness of the proposed converter, are described.

고출력 응용을 위한 영구자석 매입형 동기 릴럭턴스 전동기의 특성해석 (Characteristic Analysis of Permanent Magnet Assisted Synchronous Reluctance Motorfor High Power Application)

  • 장영진;김상길;신흥교;박성준;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.914-916
    • /
    • 2004
  • In this paper, finite element analysis for a PMASynRM is presented and the characteristic analysis of inductance and torque is performed under the effect of saturation. The focus of this paper is characteristic analysis of d and q-axis inductances and torque according to magnetizing quantity of interior permanent magnet for PMASynRM. The d and q-axis current component ratios, load angles of a PMASynRM are investigated quantitatively on the basis of the proposed analysis method and the experimental test. Comparisons are given with output characteristic curves of normal SynRM and those according to the load in PMASynRM, respectively. And it is confirmed that the proposed model results in high output power performance.

  • PDF

낮은 커플링 변압기를 갖는 개선된 고효율 공진 컨버터 (An improved high efficiency resonant converter with low coupling transformer)

  • 공영수;김은수;양승철;박진영;김종무;강도현;조정구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1166-1168
    • /
    • 2004
  • The high frequency series resonant converter has been widely used for the non-contact power supply system with the large air gap and the increased leakage inductance of the non-contact transformer. However. the high frequency series resonant converter has the disadvantages of high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, unit voltage gain is revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation results and the 5kW experimental prototype.

  • PDF

고효율 서버용 전원 장치를 위한 하프-브리지 LLC 컨버터의 공진 커패시터 온-오프 제어 (Resonant Capacitor On/Off Control of Half-Bridge LLC Converter for High Efficiency Server Power Supply)

  • 이재범;백재일;윤한신;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.285-286
    • /
    • 2015
  • In this letter, a simple control method of the HB LLC converter with one additional switch and capacitor in the primary side is proposed for wide-input-voltage applications with the hold-up time conditions. At nominal input, since the proposed method enables the HB LLC converter to operate with large transformer magnetizing inductance, it can reduce the conduction and switch turn-off losses in the primary side, which makes a high efficiency. On the other hand, during the hold-up time, since the proposed method increases the resonant capacitance by turning on one additional switch, the HB LLC converter can obtain high voltage gain.

  • PDF

직류 배전 시스템을 위한 고효율 양방향 컨버터의 설계 (Design of the High Efficiency Bidirectional Converter for DC Distributed Power System)

  • Tran, Duc-Hung;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.5-6
    • /
    • 2016
  • This paper introduces a high efficiency bidirectional resonant converter using an additional LC auxiliary circuit for dcdistribution applications. The LC auxiliary circuit operates as a variable inductor and the additional LC circuit helps to increase the effective magnetizing inductance, thereby reducing the turn-off and primary circulating current. A 5 kW bidirectional converter for dc-distribution system is implemented to verify the validity of the proposed method. The experimental results show the high efficiency characteristics of the proposed converter over the wide range of load in both direction of power flow. The maximum efficiency of the proposed system was 98.1 % at 3 kW.

  • PDF

E-I철심을 이용한 변압기형 초전도한류기의 권선 위치에 따른 전류제한 및 자화특성 분석 (Analysis on Current Limiting and Magnetizing Characteristics Due to Winding Locations of Superconducting Fault Current Limiter Using E-I Core)

  • 김보희;최상재;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권2호
    • /
    • pp.106-110
    • /
    • 2017
  • This paper compared current limiting characteristics of superconducting fault current limiter (SFCL) using E-I core due to the location of windings. Since E-I core has three legs and two magnetic paths, the current limiting characteristics of SFCL were expected to be affected by the installation location of windings, either center leg or right/left leg. To analyze its characteristics, the electrical equivalent circuit of the SFCL were derived and the electromagnetic analysis for the SFCL with the designed structure were performed. From the short-circuit tests, the hysteresis curve and the voltage-current trajectory of the SFCL due to the installation location of windings were extracted and compared each other. The SFCL with windings in the center leg of E-I core was shown to be larger magnetizing inductance compared to the one with windings in the right or left leg of E-I, which was analyzed from the hysteresis curve. In addition, larger decreased fault current right after the fault occurrence in the SFCL with windings in the center leg of E-I core was confirmed than the SFCL with windings in the right or left leg of E-I.

태양광 발전 시스템을 위한 무접점 전원장치 (A Contact-less Power Supply for Photovoltaic Power Generation System)

  • 이현관;공영수;김윤호;이기식;강성인;정봉근;김은수
    • 전력전자학회논문지
    • /
    • 제11권3호
    • /
    • pp.216-223
    • /
    • 2006
  • 태양광 발전 시스템을 위한 무접점 변압기 적용 고효율 Full-bridge LLC 공진컨버터를 제안하였다. 제안된 LLC 공진컨버터는 직렬 커패시터와의 직렬공진을 위해 무접점 변압기의 누설인덕턴스와 자화인덕턴스를 이용하였다. 제안된 LLC 공진컨버터는 공진주파수 보다 높은 스위칭영역에서 연속 공진전류로 동작하는 기존 직렬공진 컨버터와는 달리 공진주파수 아래의 좁은 주파수 범위에서 불연속 공진전류로 동작한다. 이러한 불연속모드 공진전류 때문에 제안된 컨버터는 어떤 보조회로 없이 무접점 변압기 1차측 주스위칭 소자의 영 전압 스위칭(ZVS)과 2차측 다이오드의 영 전류 스위칭(ZCS)을 얻을 수 있고, 높은 전압이득특성을 갖는다. 본 논문에서는 무접점 변압기 적용 Full-bridge LLC 공진컨버터를 이용한 무접점 전원장치에 대한 이론적 해석 및 시뮬레이션을 통해 150W급 시제품을 제작하여 태양광 발전 전원시스템에 적용 실험한 결과를 서술했다.

고주파 공진현상을 이용한 CW CO2 레이저의 출력리플 최소화 (Minimization of a CW CO2 Laser Output Ripple by using High Frequency Resonance Phenomena)

  • 사쿠라;권민재;김희제;이동길;허국성
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.798-802
    • /
    • 2013
  • In a conventional DC power supply used for CO2 laser, the circuit elements such as a rectifier bridge, a current-limiting resistor, a high voltage switch, energy storage capacitors ans a high-voltage isolation transformer using high turn ratio are necessary. Consequently, those supplies are expensive and require a large space. Thus, laser resonator and power supply should be optimally designed. In this paper, we propose a new power supply using high frequency resonance phenomena for CW(Continuous wave) CO2 laser (maximum output of 23W with discharge length of 450mm). It consists of a transformer including leakage inductance, magnetizing inductance and half-bridge converter, a three-stage Cockcroft-Walton and PFC(Power factor correction) circuit. The output ripple voltage can be controlled the minimum of 0.24% under the high frequency switching of 231kHz. Furthermore, the output efficiency was improved to 16.4% and the laser output stability of about 5.6% was obtained in this laser system.

직ㆍ병렬 공진형 컨버터를 이용한 비접촉전원 (Non-Contact Power Supply Using the Series-Parallel Resonant Converter)

  • 공영수;김은수;양승철;김종무;신병철
    • 전력전자학회논문지
    • /
    • 제9권5호
    • /
    • pp.405-412
    • /
    • 2004
  • 본 논문에서는 1차 측이 20m이상의 긴 트랙케이블(Track Cable)로 2차 측은 큰 에어 갭(Air-gap)을 갖는 픽업코일(Pick-up Coil)로 구성되어 있는 비접촉 전원에 대해서 서술하였다. 이러한 비접촉 전원은 1차 측 누설 인덕턴스가 자화 인덕턴스보다 크기 때문에 커플링이 좋지 않아 1차 측의 에너지를 2차 측으로 효율적으로 전달 할 수 없다. 이와 같은 문제점을 개선하기 위하여 본 논문에서는 직렬공진 컨버터, 병렬공진 컨버터 그리고 직ㆍ병렬공진 컨버터(SPRC)의 주 회로를 해석하였고, 각 회로에 대한 전압이득 특성을 비교 검토하였다. 그리고 10kW 직ㆍ병렬공진 컨버터(SPRC)에 대한 실험결과를 서술했다.

이중출력을 갖는 새로운 전류환류형 DC-DC 컨버터의 해석 (Analysis of a New Current-Fed DC-DC Converter with the Double Outputs)

  • 홍성민;김창선;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2033-2036
    • /
    • 1997
  • In this paper, we proposed a novel current-fed DC-DC converter with multi-output. It has two winding reactor in series with the input source of the converter. By using the 2nd winding recycling the energy stored in the reactor to the input, the double-outputs DC-DC converter can be created, which makes it a good choice for a multi-output power supply with more outputs and has savings in cost and space. The steady state and dynamic characteristics of the converter are analyzed in detail by using the state space averaging method. It is found that the maximum value of $V_{o2}$ exists in the 2nd output and also during the MOSFET off period, the energy stored in the magnetizing inductance is reset through auxiliary winding $N_3$, so the duty cycle is restricted to 50%. Theoretical and experimental results were taken from the converter rated at switching frequency 50kHz. input voltage 50V. output voltage 5V. 12V and output power 65W. As a result, both results were well consistent. Therefore, it is varified the validity of the proposed converter in this paper.

  • PDF