• 제목/요약/키워드: Magnetized plasma

검색결과 59건 처리시간 0.024초

자화된 평판형 유도 결합 $SF_6$ 플라즈마의 특성 (The Properties of Weakly Magnetized Planar Type Inductively Coupled $SF_6$ Plasma)

  • 윤차근;도현호;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.438-440
    • /
    • 1995
  • The impedance characteristics and plasma parameters were experimentally studied in a weakly magnetized planar type, inductively coupled plasma (ICP) system. Compared with non-magnetized for system higher power transfer efficiency, stable impedance matching, enhancement of plasma density and higher electron temperature can be obtained. Such improvements are mainly due to the excitation of deeply penetrating electromagnetic wave and reduction of radial loss of electrons. In particulary, $SF_6$ (sulfur hexafluride) plasma shows unstable impedance matching in non-magnetized ICP because electronegativity of $SF_6$ effects on plasma characteristics. But, magnetized inductively coupled $SF_6$ plasma shows enough impedance matching stability to be applicable to the polysilicon etching in semiconductor process.

  • PDF

Cutoff Probe를 이용한 자화유도결합 플라즈마의 특성 연구 (A Study on Magnetized Inductively Coupled Plasma Using Cutoff Probe)

  • 손의정;김동현;이호준
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1706-1711
    • /
    • 2016
  • Electromagnetic wave simulation was performed to predict characteristics of manufactured cutoff probe at low temperature magnetized plasma medium. Microwave cutoff probe is designed for research the properties of magnetized inductively coupled plasma. It was shown that the cutoff probe method can safely be used for weakly magnetized high density plasma sources. Cutoff probe system with two port network analyzer has been prepared and applied to measure electron density distributions in large area, 13.56MHz driven weakly magnetized inductively coupled plasma source. The results shown that, the plasma frequency confirmed cut-off characteristics in low temperature plasma. Especially, cut-off characteristics was found at upper hybrid resonance frequency in the environment of the magnetic field. In case of a induced weak magnetic field in inductively coupled plasma, plasma density estimated from the cutoff frequency in the same way at unmagnetized plasma due to nearly same plasma frequency and upper hybrid resonance frequency. The plasma density is increased and uniformity is improved by applying a induced weak magnetic field in inductively coupled plasma.

자화된 헬리칼 공진기 플라즈마 소스를 이용한 고선택비 산화막 식각에 관한 연구 (A study on the high selective oxide etching using magnetized helical resonator plasma source)

  • 이수부;임승완;이석현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.309-314
    • /
    • 1999
  • The magnetized helical resonator plasma etcher has been built. Electron density and temperature were measured as functions of rf source power, axial magnetic field, and pressure. The results show electron density increases as the magnetic field increases and reached $2\times1012cm^{-3}$,/TEX>. The oxide etch rate and selectivity to polysilicon were investigated as the above mentioned conditions and self-bias voltage. We can obtain the much improved oxide etch selectivity to polysilicon (60 : 1) by applying the external axial weak magnetic field in magnetized helical resonator plasma etcher.

  • PDF

자화된 플라즈마 내에서의 단분산 입자의 하전량 특정 (Measurement of Monodisperse Particle Charging in Unmagnetized and Magnetized Plasmas)

  • 한장식;안강호;김곤호
    • 반도체디스플레이기술학회지
    • /
    • 제1권1호
    • /
    • pp.35-40
    • /
    • 2002
  • Understanding of charging properties of a small particle is necessary to control the particle contamination and to improve productivity of the electronic device in the plasma aided semiconductor manufacturing processes. In this study, the effects of both magnetic field and particle size on the charging properties are experimentally investigated in collisional dusty plasmas. The experiments carried out in the system consisted of a monodisperse particle generation system, a DC magnetized plasma generation system and a charge measurement system. The plasma chamber is made of cross-shape Pyrex surrounded by magnetic bucket (composed of 12 permanent magnetic bar) to confine the plasma. DC magnetic field up to 250G are applied to the plasma zone by external magnetic coil. Previous work shows the charging effect clearly increase with increasing the size of the particle and plasma density, as it was expected.

  • PDF

2차원 동역학 시뮬레이션을 활용한 부분적으로 자화된 용량성 결합 플라즈마 전산 모사 (2D Kinetic Simulation of Partially Magnetized Capacitively Coupled Plasma Sources)

  • 손성현;박준범;정경재
    • 반도체디스플레이기술학회지
    • /
    • 제22권1호
    • /
    • pp.118-123
    • /
    • 2023
  • Partially magnetized capacitively coupled plasma (CCP) sources are investigated using a two-dimensional kinetic simulation code named EDIPIC-2D. A converging numerical solution was obtained for CCP with a 60 MHz power source, while properly capturing the dynamics of electrons and power absorption over a single RF period. The effects of magnetic fields with different orientations were evaluated. Axial magnetic fields caused changes in the spatial distribution of plasma density, affecting the loss channel. Transverse magnetic fields enhanced stochastic heating near the powered electrode, leading to an increase in plasma density while the significant E×B drift loss compensated for this rise.

  • PDF

Effect of the magnetized water supplementation on blood glucose, lymphocyte DNA damage, antioxidant status, and lipid profiles in STZ-induced rats

  • Lee, Hye-Jin;Kang, Myung-Hee
    • Nutrition Research and Practice
    • /
    • 제7권1호
    • /
    • pp.34-42
    • /
    • 2013
  • This study investigated the effects of magnetized water supplementation on blood glucose, DNA damage, antioxidant status, and lipid profiles in streptozotocin (STZ)-induced diabetic rats. There were three groups of 4-week-old male Sprague-Dawley rats used in the study: control group (normal control group without diabetes); diabetes group (STZ-induced diabetes control); and magnetized water group (magnetized water supplemented after the induction of diabetes using STZ). Before initiating the study, diabetes was confirmed by measuring fasting blood glucose (FBS > 200 dl), and the magnetized water group received magnetized water for 8 weeks instead of general water. After 8 weeks, rats were sacrificed to measure the fasting blood glucose, insulin concentration, glycated hemoglobin level, degree of DNA damage, antioxidant status, and lipid profiles. From the fourth week of magnetized water supplementation, blood glucose was decreased in the magnetized water group compared to the diabetes group, and such effect continued to the 8th week. The glycated hemoglobin content in the blood was increased in the diabetes group compared to the control group, but decreased significantly in the magnetized water group. However, decreased plasma insulin level due to induced diabetes was not increased by magnetized water supplementation. Increased blood and liver DNA damages in diabetes rats did significantly decrease after the administration of magnetized water. In addition, antioxidant enzyme activities and plasma lipid profiles were not different among the three groups. In conclusion, the supplementation of magnetized water not only decreased the blood glucose and glycated hemoglobin levels but also reduced blood and liver DNA damages in STZ-induced diabetic rats. From the above results, it is suggested that the long-term intake of the magnetized water over 8 weeks may be beneficial in both prevention and treatment of complications in diabetic patients.

Correlation between Coil Configurations and Discharge Characteristics of a Magnetized Inductively Coupled Plasma

  • Cheong, Hee-Woon
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.222-228
    • /
    • 2016
  • Correlation between coil configurations and the discharge characteristics such as plasma density and the electron temperature in a newly designed magnetized inductively coupled plasma (M-ICP) etcher were investigated. Radial and axial magnetic flux density distributions as well as the magnetic flux density on the center of the substrate holder were controllable by placing multiple circular coils around the etcher. The plasma density increased up to 60.7% by arranging coils (or optimizing magnetic flux density distributions inside the etcher) properly although the magnetic flux density on the center of the substrate holder was fixed at 7 Gauss.

Newly Designed Ion Beam Etcher with High Etch Rate

  • Cheong, Hee-Woon
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.366-370
    • /
    • 2015
  • New ion beam etcher (IBE) using a magnetized inductively coupled plasma (M-ICP) has been developed. The magnetic flux density distributions inside the upper chamber, where the plasma is generated by inductive coupling, were successfully optimized by arranging a pair of circular coils very carefully. More importantly, the proposed M-ICP IBE exhibits higher etch rate than ICP.

자화된 평판형 유도 결합 플라즈마의 특성 및 건식 식각에의 응용 (The Characteristics of Magnetized Planar type Inductively Coupled Plasma and its Application to a Dry Etching Process)

  • 이수부;박헌건;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1364-1366
    • /
    • 1997
  • Planar type magnetized inductively coupled plasma etcher has been built. The density and temperature of Ar plasma are measured as a function of rf power, external magnetic field, and pressure. The oxide etch rate and selectivity to polysilicon are measured as the above mentioned conditions and self-bias voltage.

  • PDF

유도결합형 플라즈마원을 이용한 고선택비 산화막 식각에 관한 연구 (A Study on the High Selective Oxide Etching using Inductively Coupled Plasma Source)

  • 이수부;박헌건;이석현
    • 한국전기전자재료학회논문지
    • /
    • 제11권4호
    • /
    • pp.261-266
    • /
    • 1998
  • In developing the high density memory device, the etching of fine pattern is becoming increasingly important. Therefore, definition of ultra fine line and space pattern and minimization of damage and contamination are essential process. Also, the high density plasma in low operating pressure is necessary. The candidates of high density plasma sources are electron cyclotron resonance plasma, helicon wave plasma, helical resonator, and inductively coupled plasma. In this study, planar type magnetized inductively coupled plasma etcher has been built. The density and temperature of Ar plasma are measured as a function of rf power, flow rate, external magnetic field, and pressure. The oxide etch rate and selectivity to polysilicon are measured as the above mentioned conditions and self-bias voltage.

  • PDF