• Title/Summary/Keyword: Magnetization measurement

Search Result 138, Processing Time 0.027 seconds

Measurement of the Magnetization Loss in a HTS Tape (고온초전도선재의 자화손실 측정)

  • Sim, Jeong-Uk;Lee, Hui-Jun;Cha, Gwi-Su;Lee, Ji-Gwang;Han, Song-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.182-186
    • /
    • 1999
  • Evaluation of the AC losses in the HTS tapes which are used in electric power machines in one of the important topics in this field. This paper deals with the calculation and measurement of the magnetization loss in HTS tapes. Bean model is adopted for the theoretical calculation of the magnetization loss. Magnetization method is used for the measurement of the loss. Two types of the HTS tape model, multi-filamentary model and mono-filamentary model, are used to evaluate the magnetization loss in this paper. According to the results of the analysis, large discrepancy between the calculated and measured value is observed in multi-filamentary model is more useful than multi-filamentary model for the evaluation of the magnetization loss.

  • PDF

Experimental study on the correlation between measurement length and winding or twist pitch for magnetization loss occurring in CORC and TSTC

  • Ji-Kwang Lee;Jinwoo Han;Kyeongdal Choi;Woo-Seok Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.40-44
    • /
    • 2023
  • For high-temperature superconducting power applications that need large current capacity, a large current conductor manufactured using multiple superconducting tape is required. Conductors being studied for large currents capacity such as CORC, TSTC, and RACC have advantages and disadvantages, and in order to use these conductors in coil form and apply them to AC power devices, research on magnetization loss occurring in superconductors due to external magnetic fields is essential. To accurately measure magnetization loss in a conductor that is twisted by stacking straight conductors like TSTC, the correlation between the measuring system and the shape of the sample must be clearly known to accurately measure the loss. In this paper, we will confirm the difference in magnetization loss measurement values according to the correlation between the length of the pickup coil and the twist pitch of the sample in CORC and TSTC shapes, and review considerations for accurate magnetization loss measurement from the results.

Estimation of critical current density of a YBCO coated conductor from a measurement of magnetization loss (자화손실 측정값으로부터 추정한 YBCO CC의 임계전류밀도 평가)

  • Lee, S.;Park, S.H.;Kim, W.S.;Lee, J.K.;Choi, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.16-20
    • /
    • 2010
  • For large scale power applications of HTS conductor, it is getting more important to have a stacked HTS coated conductor with low loss and large current capacity. But it was not easy to measure some electric properties. Stabilizer free YBCO CC for striated/ stacked conductors is easily burned out during the measurement of the critical current density because it has no stabilizer and it is difficult to set-up the current lead and voltage taps because it has many pieces of YBCO CC in a conductor. Instead of direct measuring the critical current of a stacked HTS coated conductor, indirect estimation from measuring a magnetization loss of HTS coated conductor could be useful for practical estimation of the critical current. The magnetization loss of a superconductor is supposed to be affected by a full penetrating magnetic field, and it tends to show an inflection point at the full penetrating magnetic field when we generate the graph of magnetization loss vs. external magnetic field. The full penetrating magnetic field depends on the shape of the conductor and its critical current density, so we can estimate the effective critical current density from measuring the magnetization loss. In this paper, to prove the effectiveness of this indirect estimation of the critical current, we prepared several different kinds of YBCO CC(coated conductor) including a stacked conductor short samples and measured the magnetization losses and the critical currents of each sample by using linked pick up coils and direct voltage measurement with transport current respectively.

A Study on Intial Susceptibility for the Prediction of Vertical Magnetization in Flash D Demagnetization (Flash D 탈자방법에서 수직자화예측을 위한 초기자화율에 관한 검토)

  • Kim, Young-Hak;Doh, Jaewon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.585-590
    • /
    • 2014
  • A permanent vertical magnetization should be obtained to counteract induced vertical magnetization due to the earth's background field during the Flash D demagnetization process. A vertical susceptibility is needed to calculate a extra-permanent magnetization, which is needed to control the permanent vertical magnetization in stage 2 of Flash D demagnetization and added to the final vertical permanent magnetization. Two susceptibilities were found in this paper. One is obtained from the extra-magnetization. The other is obtained by magnetic field measurement from the scaled physical vessel when the vessel is excited by vertical magnetic field. The initial susceptibility by the extra-magnetization was 0.101~0.109 and the one from the measured magnetic field was 0.122. Two susceptibilities have a good agreement each other. From this paper, it is found that the susceptibility is able to appllied to calculate the extr-magnetization.

Measurement of magnetization loss according to the winding pitch of CORC®

  • Han, Jinwoo;Choi, Kyeongdal;Kim, Woo-Seok;Lee, Ji-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.25-29
    • /
    • 2021
  • For the application of HTS wire to AC power equipment, a conductor with high current capacity and low loss is required. CORC®, one of the high-current conductors manufactured using several HTS wires, is made by winding the wires in a spiral on a cylindrical former. Because the magnetization loss of a CORC® conductor depends on the degree of magnetic coupling between the wires constituting the CORC®, it is necessary to know the value of the magnetization loss of the CORC® itself. In order to obtain an accurate loss value, it is necessary to know the effect of the ratio of the winding pitch of the CORC® conductor in the pickup coil region sampling the magnetization loss signal. To confirm this effect, we prepare CORC® samples having various winding pitches, and measure and compare the magnetization losses. In addition, the magnetization loss was measured while rotating the CORC® samples and it was examined whether there was a difference in the magnetization loss according to the rotation.

Round-robin Test on AC Losses in a Technical High-Tc Superconducting Tape (실용고온초전도테이프의 교류손실에 대한 Round-robin테스트)

  • 류경우;최병주;황시돌
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.437-443
    • /
    • 2004
  • In this work the AC loss measurement setup based on an iron core background magnet, not used in a conventional one, has been successfully developed. To prove its validity, a round-robin test for the same Bi-2223 tape sample among three institutes has been done. The results show that the self-field and magnetization losses from the developed setup well agree with the losses measured at two other institutes of Korea Basic Science Institute and Yokohama National University. The measured magnetization losses for parallel or perpendicular fields can be well predicted from the slab model or the strip model for a filamentary region. However the magnetization losses for longitudinal fields can be rather predicted by the slab model for a decoupled filament. The self-field losses are well explained by the Norris ellipse model.

Numerical Analysis and Measurement of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry (적층 배열형상에 따른 BSCCO 적층선재의 자화손실 특성 수치해석 및 측정)

  • Park, Myung-Jin;Lim, Hyoung-Woo;Lee, Kwang-Youn;Cha, Guee-Soo;Lee, Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.2
    • /
    • pp.83-88
    • /
    • 2006
  • AC loss is one of the main research area in AC power application using high temperature superconductor(HTS), such as HTS transformer, HTS current limiter and HTS cable, because it is closely related to efficiency, economic estimation and design of power device. A lot of research for various arrangements of HTS tapes have been performed to increase a capacity of transport current because single HTS tape can not satisfy the demanded current capacity in HTS power application. In this paper, we studied magnetization loss by different several arrangements of BSCCO tapes such as Edge-to-Edge type, Face-to-Face type and Matrix type through numerical analysis by 2D-FEM and measurement. As a result, we got the result that the magnetization loss of Face-to-Face type arrangements was lower than those of other arrangement types under the conditions of the same stacking number. We think that the result was due to shield effect by demagnetization of adjacent HTS tapes which are located face to face.

The vortex dynamics in $Bi_2$$Sr_2$Ca$Cu_2$$O_8$single crystals unirradiated and with low-density columnar defect (저밀도 원통형 결함이 $Bi_2Sr_2CaCu_2O_8$ 단결정의 볼텍스 동역학에 미치는 영향)

  • Lee, T.W.;Lee, C.W.;Shim, S.Y.;Ha, D.H.;Kim, D.H.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.36-40
    • /
    • 2001
  • We have studied vortex dynamics in$ Bi_2$$Sr_2$$CaCu_2$O$_{8}$single crystals of unirradiated and irradiated samples by using 100 $\times$ $100\mu\textrm{m}^2$Hall sensor. Doses equivalent magnetic fields are 20 G, 100 G and 1 kG. In the magnetization measurement, a second magnetization peak (SMP) was observed in unirradiated, 20 G dose and 100 G dose samples in contrast to 1 kG dose sample. In the unirradiated sample, the SMP was observed in the range of 18 K ~ 35 K and the amplitude of the SMP decreased with increasing temperature. With increase of the irradiation dose, temperature region and sharpness of the SMP were reduced. In the magnetic relaxation measurement, we observed that the normalized relaxation rate S decreased with increasing the irradiation dose. Our results suggest that the vortex dynamics is not greatly affected by low-density columnar defects.s.

  • PDF

Setup and Operating Characteristics of the Experimental Apparatus for Magnetization Measurements of Sperconductor (초전도체 자화특성 측정을 위한 실험장치의 구축 및 그 동작 특성)

  • 최세용;나완수;주진호
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.30-36
    • /
    • 1999
  • Superconductors are dissipative when exposed to time-varying magnetic fields. To analyze the AC characteristics of a superconductor, one usually needs to know magnetization curves of it. Good magnetization curves can be obtained only in homogeneous magnetic filed. In This paper, we report the setup and test results of a magnetization measurement system, which consists mainly of frequency-variable power supply and homeogenous magnet with 7-cm long air gap. Special emphasis are foused on the design and fabrication of the magnet, which aims to give background magnetic fields, and on the overall characteristics of the system.

  • PDF