• 제목/요약/키워드: Magnetic-circuit model

검색결과 262건 처리시간 0.044초

콘크리트 슬래브궤도에서 보상 커패시터의 위치 및 전기용량에 대한 연구 (A Study on the location of Compensation Capacitor and Capacitance in the Concrete Slab Track)

  • 김민석;이상혁;고준석;이종우;조수익;유진영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.879-891
    • /
    • 2009
  • Impedance of rails is increased by the magnetic coupling between rails and reinforcing bars in the concrete slab track. Currently, the current of track circuit has been compensated by installing the compensation capacitors on track circuit because of increasing the impedance of rails. In case of a rapid transit railway, the compensation capacitors are installed every 20[m] to compensate the current of track circuit in the concrete slab track. Because the interval of one block for a rapid transit railway is as long as 1500[m], the compensation capacitors are installed about the number of 70$\sim$75 on track circuit. However, in case the compensation capacitors are broken over the number of three, it is a problem that the amplitude of current is under standard amplitude of current which is 0.8[A]. In this paper, it was suggested installing a compensation capacitor by using resonance phenomenon on the concrete slab track. We represent the electrical model of track circuit and the four terminal network, calculate the parameters demanded for the electrical model in the concrete slab track. Also, we computed the position and capacitance of the compensation capacitor about 2040[Hz], 2400[Hz], 2760[Hz], 3120[Hz] which currently is the track circuit frequency in the Gyeongbu rapid transit railway and demonstrated the validity of it, using the Matlab and PSpice program.

  • PDF

Modeling and Filter Design through Analysis of Conducted EMI in Switching Power Converters

  • Vimala, R.;Baskaran, K.;Aravind Britto, K.R.
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.632-642
    • /
    • 2012
  • This paper presents a filter analysis of conducted Electro-Magnetic Interference (EMI) in switching power converters (SPC) based on noise impedances. The EMI characteristics of SPC can be analytically deduced from a circuit theoretical viewpoint. The analytical noise model is investigated to get a full understanding of the EMI mechanism. It is shown that with suitable and justified model, filters pertinent to EMI noise is investigated. The EMI noise is identified by time domain measurements associated with an isolated half-bridge ac-dc converter. Practical filters like LC filter, ${\pi}$ filter and complete EMI filters are investigated. The proposed analysis and results can provide a guideline for improving the effectiveness of filtering schemes in SPC. Experimental results are also included to verify the validity of the proposed method. The results obtained satisfy the Federal Communications Commission (FCC) class A and class B regulations.

3차원 와전류 해석을 위한 등가자기회로방법의 개발 (Development of Equivalent Magnetic Circuit Network Method for 3 Dimentional Eddy current Analysis)

  • 허진;홍정표;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권5호
    • /
    • pp.228-233
    • /
    • 2002
  • A computational method for analysis of the 3 dimensional electro-magnetic induction problems has been developed. The developed method is capable of modeling the induced current and analyzing its characteristics using only scalar Potential at each node. A benchmark model of asymmetrical conductor with a hole is analyzed to verify the application of the developed method. The calculated value of magnetic flux density are compared with the measured value, and the results indicate that the developed method is valid. Also, Comparing with 3-D finite element method (FEM) results, we conformed effectiveness of the developed method for the accuracy and computation times.

Basic Study of Degradation Test for Magnetic Contactors and Reliability Centered Maintenance

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.441-444
    • /
    • 2007
  • The mechanical endurance is the critical characteristic of Magnetic contactors (MCs), which are widely used in such industrial equipments as elevators, cranes, and factory control rooms in order to close and open the control circuit. Testing time, however, is so long in most cases that some method of reducing the testing period is required. Therefore, the degradation test by the detected vibration of MCs is developed to reduce the testing time in this work. The degradation test data are analyzed and the prediction model is provided. Also, the possibility of this technology for Reliability Centered Maintenance (RCM) will be shown. This will reduce the period of the product development and raise the reliability of the equipment in power distribution.

3차원 와전류 해석을 위한 등가자기회로망법의 개발 (Development of Equivalent Magnetic Circuit Network Method for 3-D Eddy Current Analysis)

  • 허진;흥정표;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.693-695
    • /
    • 2001
  • A computational method for the 3 dimensional electro-magnetic induction problems has been developed. The proposed method is capable of modeling the eddy current and analyzing its characteristics using only scalar potential. A benchmark model of asymmetrical conductor with a hole is analyzed to verify the application of the developed method. The calculated value of magnetic flux density are compared with the measured value, and the results indicate that the developed method is valid.

  • PDF

영구자석 이동형 선형 모터를 가진 초소형 공기베어링 스테이지 (A Miniature Air-Bearing Positioning Stage with a Magnet-Moving Linear Motor)

  • 노승국;박종권
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.89-96
    • /
    • 2007
  • In this paper, a new air bearing stage with magnetic preload and a linear motor has been developed for the small precision machine systems. The new air bearing stage is unique in the sense that permanent magnets attached bottom of the iron core of table are used not only for preloading air bearings in vertical direction but also for generating thrust force by current of the coil at base. The characteristics of air bearings using porous pads were analyzed with numerical method, and the magnetic circuit model was derived for linear motor for calculating required preload force and thrust force. A prototype of single axis miniature stage with size of $120(W){\times}120(L){\times}50(H)\;mm^3$ was designed and fabricated and examined its performances, vertical stiffness, load capacity, thrust force and positioning resolution.

경량전철의 전원공급선에 의해 발생되는 자기장 차폐해석

  • 송명곤;오윤상;김동훈;주민석;노석균;이상진;박정도;정상기;정락교;조홍식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.547-551
    • /
    • 2003
  • This paper presents the magnetic fields shielding properties of the light rail transit which are produced by the ripple-shaped currents in the power lines. To analyze these properties, the equivalent circuit model of the DC power supply system at the light rail transit system was induced by MATLAB-SIMULINK, and with the calculated results of the ripple-shaped currents, the magnetic fields shielding properties of the light rail transit were analyzed. The results are as follows. First The frequency of the ripple-shaped currents is 200[Hz] and its magnitude is 1.5[A]. Second the magnetic fields produced by the ripple-shaped currents of the DC power supply systems are well shielded by the aluminum made body of the light rail transit.

  • PDF

영구자석을 포함한 자기부상시스템의 부상제어 (A Suspension Control of A PM-based Magnetic Suspension System)

  • 김종문;김춘경;박민국;천종민;변한섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2264-2266
    • /
    • 2001
  • In this paper, some suspension results for a magnetic suspension system with permanent magnet are presented. The electromagnetic model using the equivalent magnetic circuit is shown. And some control simulation results using Matlab/Simulink S/W are presented.

  • PDF

자기유변유체를 이용한 스퀴즈 필름 댐퍼에서의 부강성 효과 규명 (Identification of Negative Stiffness Effects in Magneto-Rheological Fluid based Squeeze Film Damper)

  • 김근주;김정훈;이종원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.739-744
    • /
    • 2001
  • In order to investigate the stability of magneto-rheological fluid based squeeze film damper (MR-SFD), its negative stiffness effect, which arises from magnetization of MR-SFD, is identified theoretically and experimentally. The analytical model of MR-SFD includes the magnetic circuit as well as the displacement stiffness associated with the squeeze mode of MRF. Extensive experiments are carried out to measure the magnetic attraction forces generated in the MR-SFD, with the excitation frequency and the eccentricity of the journal varied, which are controlled by an active magnetic bearing. The simulation and experimental results are found to be in good agreement. It is concluded that the negative stiffness effect dominates only in the low frequency region because its effect diminishes in the high frequency region due to the eddy-current loss.

  • PDF

765kV 2회선 송전선로를 765kV 및 345kV로 병행운전시 유도현상 예측 (Analysis of the electrostatic induction voltage and electromagnetic induction current on the Parallel Circuit in 765kV Double Circuit Transmission Line)

  • 우정욱;심응보;곽주식;전명렬;김기일;김태옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.169-171
    • /
    • 2002
  • The western route of KEPCO's 765kV transmission line has been tentatively operating as 345kV voltage before commercial operation. After finishing the test operation of 765kV substation in 2002. KEPCO decided to operate the 765kV line for commercial operation. During the applying of 765kV voltage to the transmission line, double circuit transmission line will be operated with two voltage grades of 765kV and 345kV. Because the earthing switch is installed on both end of transmission line, we had estimated the electrostatic induction voltage and electromagnetic induction current before the line energizing in order to confirm the ratings of earthing switch. The induced voltage and current is very important for the maintenance of parallel circuit. This paper describes the simulation study of electrical phenomena such as electrostatic induction voltage from the parallel line and electromagnetic induction current from the parallel circuit. The transmission line model was developed by EMTP (Electro-Magnetic Transient Program).

  • PDF