• Title/Summary/Keyword: Magnetic shielding

Search Result 204, Processing Time 0.03 seconds

Designs and Fabrications of High-TC SQUID Magnetometer for Measuring a Weak Signal without Magnetic Shielding (비자기 차폐환경에서 미세자기신호 측정을 위한 고온 초전도 SQUID 자력계의 설계 및 제작)

  • Yu, K.K.;Kim, I.S.;Park, Y.K.
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.110-113
    • /
    • 2004
  • We have designed and fabricated the YBCO single layer directly-coupled SQUID magnetometers for the purpose of magnetocardiography in a magnetically disturbed environment. The SQUID magnetometers were designed three different types of pickup coil such as solid type, PL type I and PL type II for further stable fluxed-locked-loop operation without magnetic shielding. Magnetometer was fabricated with a single layer YBCO thin film deposited on STO(100) bicrystal substrate with misorientation angle of $30^{\circ}$. We have achieved a magnetic field noise BN of 30 fT/$Hz^{1/2}$ at 100 Hz, and less than 70 fT/$Hz^{1/2}$ at 1 Hz. The PL type II SQUIDs have exhibited the most stable fluxed-locked-loop operation in a magnetically unshielded environment.

Design of Zr-7Si-xSn Alloys for Biomedical Implant Materials (생체의료용 임플란트 소재를 위한 Zr-7Si-xSn 합금설계)

  • Kim, Minsuk;Kim, Chungseok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.1
    • /
    • pp.8-19
    • /
    • 2022
  • The metallic implant materials are widely used in biomedical industries due to their specific mechanical strenth, corrosion registance, and superior biocompatability. These metallic materials, however, suffer from the stress-shielding effect and the generation of artifacts in the magnetic resonance imaging exam. In the present study, we develope a Zr-based alloys for the biomedical implant materials with low elastic modulus and low magnetic susceptibility. The Zr-7Si-xSn alloys were fabricated by an arc melting process. The elastic modulus was 24~31 GPa of the zirconium-based alloy. The average magnetic susceptibility value of the Zr-7Si-xSn alloy was 1.25 × 10-8cm3g-1. The average Icorr value of the Zr-7Si-xSn alloy was 0.2 ㎂/cm2. The Sn added zirconium alloy, Zr-7Si-xSn, is very interested and attractive as a biomaterial that reduces the stress-shielding effect caused by the difference of elastic modulus between human bone and metallic implant.

Evaluation of the Utility of Self Produced MRI Radiofrequency Shielding Material (자체 제작한 자기공명영상 고주파 차폐체의 유용성 평가)

  • Lee, Jin-Hoe;Lee, Bo-Woo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.89-94
    • /
    • 2020
  • This paper proposes a better shielding method to over sampling technique. The new method uses aluminum foil for RF shielding. As a result of the phantom test, when the over-sampling technique was applied, the aliasing artifact was reduced by about 94% compared to before the application, and the case where the aluminum shielding band was applied was also reduced by about 92% compared to before application. In addition, the scan time also increased by more than 3 times in the case of the over-sampling technique, while it was found that there was no change from before the application of the aluminum shielding band Therefore, it was confirmed that the shielding band using aluminum foil can effectively remove aliasing artifacts without increasing the scan time..

Evaluation of sustainability of mobile phone case and improvement of electromagnetic shielding by nano particles (휴대폰 케이스의 지속가능성 평가 및 나노 입자를 사용한 전자기파 흡수성능 개선)

  • Kang Y.C.;Jung W.K.;Ahn S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.477-480
    • /
    • 2005
  • In this paper, the concept of sustainability was applied to mechanical design and manufacturing of mobile-phone case. A new evaluation method to find products' good and weak point for sustainability was developed. Two mobile phones were evaluated using the evaluation tool. As a result, electro-magnetic (EM) wave was considered as a harmful factor of the products, and improved front panel was made using nano particles that absorb EM waves. The EM shielding tests revealed that silver nano powders absorbed EM while MWCNT had no effect.

  • PDF

Hemming Process Design of the Permalloy Shielding Can for the Stiffness and Shape Accuracy (퍼멀로이 실딩캔의 강성증대 및 형상 정밀도를 위한 최적 헤밍 공정설계)

  • Lee, Sun-Bong;Kim, Dong-Hwan;Kim, Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.5
    • /
    • pp.29-35
    • /
    • 2002
  • This study shows the process design and forming analysis of permalloy shielding can that support the automobile multi-display parts to indicate the accurate information of car. This study is particularly important, since the accuracy of permalloy shielding can is known to affect the magnetic properties such as coercivity and permeability quite sensitively. The objective functions are defects such as hemming wind, hemming length, hemming wrap and tightness in prehemming process. The pre-hemming angle is considered as design parameter. The commercial finite element program PAM-STAMP™ was used to simulate the pre-hemming and hemming process. The ANN (Artificial Neural Network) has been implemented for minimizing of objective function and for investigating effect of punch angle relevant to the pre-hemming process. The results of analysis to validate the proposed design method are presented.

A Study on the Correlation between Shielding Effect of Electromagnetic Field and Immunity of Radiated Radio Frequency (전자파 차폐효과와 방사고주파 내성과의 상관관계에 대한 연구)

  • Park, Chan-Won;An, Hwang-He
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2462-2464
    • /
    • 1999
  • All electric and electronic appliances require their own electromagnetic compatibility. So an industrially advanced nations have made many standards for regulation for their profits thus the researches on the electro-magnetic shielding effect(SE) are being increased. But the SE can not proved its effect by a theory alone because of complex-material problems. This study Present the correlation of the SE and immunity of radiated radio frequency of the electromagnetic field. We have analyzed the theory of shielding effect to the shield texture. It has been proved that experimental results showed this effects have intensive relations to the electromagnetic field immunity.

  • PDF

Magnetic field Reduction characteristics of double shielding wear for a worker by using AC Arc welder (교류 아크용접기를 사용하는 작업자의 이중차폐복 자계저감 특성검토)

  • Park, Jun-Hyeong;Min, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.73-74
    • /
    • 2008
  • This paper analyses current densities induced inside a worker using AC arc welder when he wear a protective with double shielding cloth. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 1[cm] far from a power cable of AC arc welder. As results of study, we fined aa protective cloth, which has high permeability in inner layer and high conductivity in outer layer, can give a higher shielding efficiency.

  • PDF

A Modified Calculation of Electromagnetic Shielding Effectiveness Considering Some electrical Parameters (발산가응계통에서의 뉴톤-랍슨 전력게통합)

  • Sang-Jin Lee;Myung-Hwan Oh
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.31 no.12
    • /
    • pp.173-179
    • /
    • 1982
  • This paper presents a modified quasi-static approximate solution derived from the Maxwell's equations of integral form for the calculation of magnetic shielding effectiveness in a non-uniform enclosure such as metal-clad high-voltage test laboratory. It also describes the simplified relationship between the electrical parameters applicable to the engineering calculations of electromagnetic absorption loss which comprise the resultant effects due to the welding seams and short-circuited slots as well as the shielding material properties. A numerical example shows the fairly good agreements with experimental results measured on the absorption loss vs. incident wave frequency without any unreasonable rapid increase.

  • PDF

The Development of Magnetic Field Measurement System of 3 Axis (3축 자계 측정 시스템의 개발)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.253-257
    • /
    • 2017
  • Nowadays, it is increasingly important to detect whether cables are live for the operator's safety if there is a sudden power failure. It is especially hard to detect the electrical field of an underground line because of shielding. This paper on detection of live-line states in cables studied the detection characteristics of the change in the magnetic field and axis as the frequency, voltage, and distance at the same load are changed using 3 axes. A search coil type was used as a magnetic field sensor with non-contact. We found that magnetic fields decrease proportionally to the square of the distance and the decrease of rated voltage with load effected to magnetic field. The magnetic field was detected by 3-axis sensors given correct proximity, but appeared as noise components beyond a distance of 2 cm.

An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall for Shielding High-altitude Electromagnetic Pulse (HEMP) (고고도 전자기파(HEMP)차폐를 위한 전자파 차폐 콘크리트 벽체 개발에 관한 실험적 연구)

  • Choi, Hyun-Jun;Kim, Hyung-Chul;Lim, Sang-Woo;Lee, Han-Seung
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.169-177
    • /
    • 2017
  • Rather than causing damage from heat, blast, and radiation of a regular nuclear weapon, recently, it is predicted that North Korea has been inventing high altitude electromagnetic pulse (HEMP) missile in order to incapacitate electronic equipment. HEMP shielding facility is used for military purpose today. Despite the electromagnetic shielding effects from high quality compression plates, problems may include such as the possibility of electromagnetic influx resulting in the welding of the compression plates, and difficulties and high cost of construction. Therefore, in this study, a high electrical conducting material was added to the concrete experimental subject to ensure the shielding effect through electromagnetic waves to for the concrete structure, instead of building a shielding facility separately for the structure. Also, among the experimental subjects, 100 ${\mu}m$ of Iron-Aluminum alloy metal spraying coat was applied to two types with the highest shielding effect, and to two types with the lowest shielding effect. The result of the experiment indicates that experimental subjects added with a high electrical conductivity material did not meet the minimum shielding criteria of MIL-STD-118-125-1 standard, but all the experimental material applied to the metal spraying coating satisfied the minimum shielding criteria. In conclusion, it is considered that 100 µm of Iron-Aluminum alloy metal spraying coat contains high efficiency in the HEMP shielding.