• Title/Summary/Keyword: Magnetic sensor

Search Result 1,069, Processing Time 0.029 seconds

A Method and System to Compensate Vertical Component of 3-Axes Magnetic Field Sensor Using the Earth's Field (지구자계를 이용한 3축 자계센서의 수직성분 자계 보정방법 및 장치)

  • Jeong Yeong-Yun;Im Dae-Yeong;Yu Yeong-Jae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.241-244
    • /
    • 2006
  • 본 논문은 지구자계를 이용하여 3축 자계센서의 수직 성분자계를 보정하는 방법과 장치를 제안한다. 자계센서는 설치각도 및 이득오차에 의해 출력 특성이 변화한다. 따라서 자계센서를 사용하기에 앞서 보정이 필요하다. 지구에서 발생되는 지구자계를 이용하여 간편하게 센서의 설치각도 및 이득오차에 의한 영향을 보정하였으며 이를 위한 장치를 설계하였다. 제안한 방법은 실험을 통하여 실용성을 검증하였다.

  • PDF

The Detection of Defects in Ferromagnetic Materials Using Magneto-Optical Sensor (자기광학센서를 이용한 강자성체 결함 탐상)

  • Kim, Hoon
    • Journal of Power System Engineering
    • /
    • v.8 no.3
    • /
    • pp.52-57
    • /
    • 2004
  • A new non-destructive inspection technique has been developed. One characteristic of the technique is that defects are visualized by laser ray. Magnetic domains and domain walls of a magneto-optical sensor(MO sensor) are varied by the magnetic flux leaked by defects, and the variations are observed by the reflected light of the laser ray. The information of defect can remotely be inspected by this technique in a real time. This paper describes the results estimated on the 2-dimensional surface defects and opposite-side defects in a ferromagnetic material and the natural surface defect in a clutch disk wheel. The light region of a visible image and the magnitude of a reflected light increases as the input current of the magnetizer increases. The natural surface defect, that has not the width of crack's open mouth, can be also visualized like as 2-dimensional artificial defects.

  • PDF

A Study Using the Taguchi Method and 3D FEM Analysis of Magnetic Position Sensor for harmonic reduction (다구찌 기법과 3D FEM해석을 이용한 Magnetic position sensor의 고조파 저감에 대한 연구)

  • Kim, Min-Gyu;Sung, Ki-Young;Hwang, Su-Jin;Ryu, Dong-Seok;Huang, Zhan-Hong;Kim, Won-Kyu;Kim, Youn-Hyun;Kim, Ki-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.904-905
    • /
    • 2011
  • 본 논문에서는 기존의 EPS(Electric Power Steering) 시스템에 IPMSM을 적용하고 속도 및 위치를 검출하기 위하여 Magnetic Position Sensor를 사용하였다. 이�� Magnetic Position Sensor의 신호는 정현파의 출력을 갖지만 고조파의 성분으로 인하여서 파형이 왜곡되고 이러한 파형의 왜곡으로 인해 위치 검출의 오차를 갖게 된다. 본 논문에서는 이러한 오차를 줄이기 위하여 다구찌 기법과 3차원 유한요소법(3D FEM)을 사용하여 고조파를 저감시킬 수 있도록 여러 변수를 변화하여서 최적의 설계를 통하여 실제 실제 센서 출력과 비교하여 자동차 산업 전반에 기여 하고자 한다.

  • PDF

A new magnetic sensor for the non-contact measurement of bending vibrations of non-ferromagnetic pipes (비자성 배관의 비접촉 굽힘 진동 측정을 위한 자기 센서의 개발)

  • Han, Soon-Woo;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1154-1158
    • /
    • 2006
  • This investigation suggests a new non-contact type sensor that can measure flexural vibrations of a non-ferromagnetic pipe. The sensor works on the reversed Lorentz force mechanism; however, anti-symmetric bias magnetic field suggested in this work should be applied to measure bending vibration of a non-ferromagnetic pipe. The importance of the suggested magnetic field is verified by a series of experiments. The sensor is applied to the bending vibration measurement and modal testing of an aluminum pipe and shows satisfactory working performance compared to others.

  • PDF

Implementation of Optical Magnetic Field Sensor for Measurement of Over Current (과전류 계측을 위한 광자계센서의 구현)

  • Park, Hae-Soo;Roh, Jong-Dae;Kim, Yo-Hee;Park, Byung-Seok;Ahn, Seong-Joon;Jo, Hong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1871-1873
    • /
    • 1997
  • The conventional current transformers are often take faults and out of order that for detect to over current of electric power lines because electromagnetic interference. But, it is possible to implement protection relay of high reliability using optical magnetic field sensor which are immunity and small size. The optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. And it is not necessary to make with capacitance of electric power lines as optical magnetic field sensor is have linearity from 0 to about 20kA. In this study, we designed and constructed compensative feedback circuit in order to minimize of optical power intensity variation with environ- mental variations(temperature, drive current) of light source. And this system have highest optical advantages and reliability.

  • PDF

Magnetic Field Properties About Core Change (코어 변화에 대한 자계 특성)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • In this paper, it tried to develop the core sensor for detection of micro magnetic field in electric wires. The sensor is non contact type and is consisted of ferrite core for low price. To investigate their properties for variations of current, it changed the number of winding and the length of sample core, it examined, to check the live wire situation in built-in wires, electrical characteristics due to difference between electric wires and core sensor. As the results, it verified live wire situation at the number of winding(5,000) and within length of 6[cm]. Also, it obtained magnetic field magnitude decreased inverse proportion ratio to a square about difference between electric wires and core sensor.

Development of Methodology to Measure the Thickness of Pipes using Magnetic Field (마그네틱 필드를 이용한 배관 두께 측정 방법론 개발)

  • Kim, Mi Na;Chai, Jang Bom;Park, Il Han;Kim, E Noch
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.47-53
    • /
    • 2010
  • In this research project, development of methodology to measure the thickness of pipes in the wide range using magnetic field. The magnetic field spreading in the sensor and the plate was modeled in the cases of the various thicknesses in plate. Based on the analysis, sensors were designed, manufactured and tested to optimize the specifications of the sensor. The sensor can be used in high temperature through calibration. And the uncertainty of the sensor was estimated.

  • PDF

Research md Development of Inprocess Measuring Magnetic sensor for Tolerance Control (공차제어를 위한 인프로세스 계측 자기센서의 개발 연구)

  • 신용진;소대화;김현욱;이광배;강재덕
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.1
    • /
    • pp.89-97
    • /
    • 2000
  • This paper shows the study for development inprocess measuring magnetic sensor for tolerance control, First, we fabricated and annealed sample amorphous ribbons which were made of ($CO_{0.94}$$Fe_{0.06}$)$_{79}$$Si_{2}$$b_{19}$ having near zero magnetostrictive. It had 12[$\mu\textrm{m}$] of thickness, 10[mm] of length, and 2.5[mm] of width. Then, we measured the magnetic characteristics such as frequency dependency over impedance variation rate and position change over impedance variation. As the results of the evaluation, we found that the sample ribbons had excellent sensor characteristics. Then, we made sensors by using the sample ribbons, As the results of the measurements, it proved that the ribbon could be used as excellent magnetic sensor for which it was possible to control inprocess measurement within the tolerance range(~$\mu\textrm{m}$ ).

  • PDF

Remote gas meter-reading system using magnetic sensor (자계 센서를 이용한 원격 가스 검침 시스템)

  • Koo, JaYl
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.90-94
    • /
    • 2002
  • This paper is related to remote meter-reading using magnetic sensor. Scan system which is developed recently has week point of temperature, humidity, dust, oscillation To solve these problems, this study used magnetic action to measure the consumption of gas. Gas consumption was detected by interaction of a permanent magnet and hall element. Permanent magnet was pasted on rolling change-gear in normal gas meter and hall sensor was pasted on the external wall of normal gas meter. This experiment proved high accuracy and wasn't influenced by temperature, humidity, oscillation and dust

An implementation of a magnetic-field measurement system based on optical sensor (광센서를 이용한 자기장 계측 장치 구현)

  • Kim, Young-Soo;Park, Byung-Seok;Kim, Myong-Soo;Lim, Yong-Hun;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.219-222
    • /
    • 2002
  • In this paper, some parameters are studied for the performance improvement of a bulk optical magnetic-field sensor. The performance of optical magnetic-field sensor is influenced by optical intensity change and wavelength change of light source, and phase shift so called optical bias mismatch. A magnetic field measuring system based on optical Faraday sensor is implemented and tested in the current range from 10 ampere to 200 ampere. The test result shows implemented system has goof linearity.

  • PDF