• Title/Summary/Keyword: Magnetic Velocimetry

Search Result 9, Processing Time 0.018 seconds

Velocity measurements in complex flows of non-Newtonian fluids

  • Muller, Susan J.
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.3
    • /
    • pp.93-105
    • /
    • 2002
  • Experimental methods for making quantitative measurements of velocity fields in non-Newtonian fluids are reviewed. Techniques based on light scattering spectroscopy - laser Doppler velocimetry and homodyne light scattering spectroscopy, techniques based on imaging the displacement of markers - including particle image velocimetry and molecular tagging velocimetry, and techniques based on nuclear magnetic resonance imaging are discussed. The special advantages and disadvantages of each method are summarized, and their applications to non-Newtonian flows are briefly reviewed. Example data from each technique are also included.

Validation of Magnetic Resonance Velocimetry by Turbulent Pipe Flow (자기공명유속계를 이용한 난류 유동장 가시화)

  • Lee, Jeesoo;Song, Simon;Cho, Jee-Hyun
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • Magnetic resonance velocimetry (MRV) is a versatile flow visualization technique using magnetic resonance imaging machine developed for the medical purpose. Recently, MRV is often utilized to analyze engineering flows due to its superior features of MRV such as capabilities of measuring flows with complicated, opaque flow geometry unlike optical techniques, 3-dimensional volumetric velocity vectors within a few hours, and etc. The purpose of this study was to validate the MRV data and evaluate the accuracy of the mean velocity profiles that we acquired for a turbulent flow in a circular pipe using a MR machine installed in Korea Basic Science Institute, Ochang, Korea. In addition, we briefly describe a procedure of parameter optimization for the operation of MRV. The results indicate that the MRV measurements provided well resolved mean velocity fields with a quite reasonable accuracy according to the inner and outer layer scaling laws of the turbulent pipe flows.

Analysis and Comparison of Stream Discharge Measurements in Jeju Island Using Various Recent Monitoring Techniques (다양한 첨단 유량 계측기기를 활용한 제주도 하천 유출 비교 분석)

  • Yang, Sung-Kee;Kim, Dong-Su;Jung, Woo-Yul;Yu, Kwon-Kyu
    • Journal of Environmental Science International
    • /
    • v.20 no.6
    • /
    • pp.783-788
    • /
    • 2011
  • Different from the main land of South Korea, Jeju Island has been in difficulties for measuring discharge. Due to high infiltration rate, most of streams in Jeju Island are usually in the dried state except six streams with the steady base flow, and the unique geological characteristics such as steep slope and short traveling distance of runoff have forced rainfall runoff usually to occur during very short period of time like one or two days. While discharge observations in Jeju Island have been conducted only for 16 sites with fixed electromagnetic surface velocimetry, effective analysis and validation of observed discharge data and operation of the monitoring sites still have been limited due to very few professions to maintain such jobs. This research is sponsored by Ministry of Land, Transport and Maritime Affairs to build water cycle monitoring and management system of Jeju Island. Specifically, the research focuses on optimizing discharge measurement techniques adjusted for Jeju Island, expanding the monitoring sites, and validating the existing discharge data. First of all, we attempted to conduct discharge measurements in streams with steady base flow, by utilizing various recent discharge monitoring techniques, such as ADCP, LSPIV, Magnetic Velocimetry, and Electromagnetic Wave Surface Velocimetry. ADCP has been known to be the most accurate in terms of discharge measurement compared with other techniques, thus that the discharge measurement taken by ADCP could be used as a benchmark data for validation of others. However, there are still concerns of using ADCP in flood seasons; thereby LSPIV would be able to be applied for replacing ADCP in such flooded situation in the stream. In addition, sort of practical approaches such as Magnetic Velocimetry, and Electromagnetic Wave Surface Velocimetry would also be validated, which usually measure velocity in the designated parts of stream and assume the measured velocity to be representative for whole cross-section or profile at any specified location. The result of the comparison and analysis will be used for correcting existing discharge measurement by Electromagnetic Wave Surface Velocimetry and finding the most optimized discharge techniques in the future.

Development of Non-Invasive Pressure Estimation Using 3D Multi-Path Line Integration Method from Magnetic Resonance Velocimetry (MRV) (자기공명유속계 (MRV) 에서 3차원 다중경로 선적분법을 활용한 비침습적 압력예측 방법 개발)

  • Ilhoon Jang;Muhammad Hafidz Ariffudin;Simon Song
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.14-23
    • /
    • 2023
  • The pressure difference across stenotic blood vessels is a commonly used clinical metric for diagnosing many cardiovascular diseases. At present, most clinical pressure measurements rely solely on invasive catheterization. In this study, we propose a novel method for non-invasive pressure estimation using the incompressible Navier-Stokes equations and a 3D multi-path integration approach. We verify spatio-temporal convergence on an in-silico dataset of a cylindrical straight pipe phantom with steady and pulsatile flow fields. We then evaluate the proposed method on an in vitro dataset of reconstructed control, pre-operative, and post-operative carotid artery cases acquired from 4D flow MRI. The performance of our method is compared to existing approaches based on the pressure Poisson equation and work-energy relative pressure. The results demonstrate the proposed method's high accuracy, robustness to spatio-temporal subsampling, and reduced sensitivity to noise, highlighting its great potential for non-invasive pressure estimation.

Flow Visualization of Magnetic Particles under the external magnetic field in bubbly flow using Single Plane Illumination Microscopy - MicroPIV (Single Plane Illumination Microscopy - MicroPIV를 이용한 버블 유동에서 외부 자계 영향을 받는 자성입자 가시화)

  • Lee, Changje;Cho, Gyeong-rae;Lee, Sangyoup
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.1
    • /
    • pp.36-42
    • /
    • 2021
  • This study measured the velocity of magnetic particles inside the power generation using external heat sources. Single Plane Illumination Microscopy (SPIM) was used to measure magnetic particles that are simultaneously affected by bubbly flow and magnetic field. It has the advantage of reducing errors due to particle superposition by illuminating the thin light sheet. The hydraulic diameter of the power generation is 3mm. Its surface is covered with a coil with a diameter of 0.3 mm. The average diameter of a magnetic particle is 200nm. The excitation and emission wavelengths are 530 and 650nm, respectively. In order to find out the flow characteristics, a total of four velocity fields were calculated in wide and narrow gap air bubbles, between the wall and the air bubble and just below the air bubble. Magnetic particles showed up to 8.59% velocity reduction in the wide gap between air bubbles due to external magnetic field.

Observing Thermal Counterflow in He II by the Particle Image Velocimetry Technique

  • Van Sciver S. W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2005
  • The Particle Image Velocimetry (PIV) technique can be used to obtain a whole-field view of thermal counterflow velocity profile in He II. Using commercially available microspheres, we have been able to visualize the normal fluid velocity in He II thermal counterflow; however, the measured velocities are less than predicted from the two fluid model. None the less, the PIV is a useful tool for observing the counterflow field in He II flow, particularly where the flow is complex as occurs through channel constrictions or around bluff objects. The present paper shows recent results using PIV to observe He II counterflow. Two cases are discussed: 1D channel flow and turbulent flow around a circular cylinder.

Development of Solenoid RF coil for 4.7 T Magnetic Resonance Velocimeter to Improve Resolution (해상도 향상을 위한 4.7 T 자기공명유속계 용 솔레노이드 RF 코일 개발)

  • Yang, Byungkuen;Cho, Jee-Hyun;Song, Simon
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.40-45
    • /
    • 2016
  • Magnetic resonance velocimeter (MRV) is a powerful tool to non-invasively measure the velocity of a fluid flow in various fields ranging from medicine to engineering. However, since the demands for accurate measurement in the solid/liquid interface for cardiovascular diseases and porous media increase, the improvement of spatial resolution is required. In this study, a solenoid RF coil is developed for high spatial resolution measurement. The signal-to-noise ratio in solenoid RF coil is increased seventeen times better than that in commercial coil. Moreover, the velocity distribution of Hagen-Poiseuille flow is measured with in-plane resolution of $36{\mu}m$ by $36{\mu}m$ and the accuracy of the measured velocity is compared with theoretical distribution of the laminar flow. Flow rate calculated by MRV is estimated with the flow rate injected by syringe pump.

Enhancement Technique of Discharge Measurement Accuracy Using Kalesto Based on Index Velocity Method in Mountain Stream, Jeju Island (지표유속법 기반 제주 산지형 하천 Kalesto 유량 정확도 향상 기법)

  • Kim, Dong-Su;Yang, Sung-Kee;Kim, Soo-Jeong;Lee, Jun-Ho
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.371-381
    • /
    • 2015
  • In the mountain streams in Jeju Island, strong turbulence and roughness usually made it nearly impossible to utilize most of intrusive instrumentation for streamflow discharge measurements. Instead, a non-intrusive fixed electro-magnetic wave surface velocimetry (fixed EWSV: Kalesto) became alternatively popular in many representative streams to measure stream discharge seamlessly. Currently, Kalesto has shown noteworthy performance with little loss in flood discharge measurements and also has successfully provided discharge for every minute. However, Kalesto has been operated to regard its measured one-point velocity as the representative mean velocity for the given cross-section. Therefore, it could be highly possible to potentially encompass discharge measurements errors. In this study, we analyzed the difference between such Kalesto discharge measurements and other alternative concurrent discharge measurements such as Acoustic Doppler Current Profiler (ADCP) and mobile EWSV which were able to measure velocity in multi-points in the cross-section. Consequently, Kalesto discharge deviated from ADCP discharge in amount of 48% for relatively low flow, and more than 20% difference for high flow compared with mobile EWSV discharge measurements. These results indicated that the one-point velocity measured by Kalesto should be used as a cross-sectional mean velocity, rather it should be accounted for as an index-velocity in conjunction with directly measured cross-sectional mean velocity by using more reliable instrumentations. After inducing Kalesto Discharge Correction Coefficient (KDCC) that actually means relationship between index velocity and cross-sectional mean velocity, the corrected discharge from Kalesto was significantly improved. Therefore, we found that index velocity method should be applied to obtain better accuracy of discharge measurement in case of Kalesto operation.

Optimization of Flow Uniformity in an Electrostatic Precipitator (ESP) Duct (전기집진기 (ESP) 덕트 내부 유동 균일화를 위한 연구)

  • Junhyung, Hong;Minseung, Hwang;Joungho, Han;Woongchul, Choi;Jeongmo, Seong;Wontae, Hwang
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.86-93
    • /
    • 2022
  • An electrostatic precipitator (ESP) is an industrial post processing facility for high efficiency dust mitigation. Uniformity of the flow passing through the inlet duct leading into the main chamber is important for efficient reduction of dust. To examine flow uniformity, this study conducted a numerical analysis of the flow within a scale-down ESP inlet duct. Magnetic resonance velocimetry (MRV) results from a prior study were utilized to validate the Reynolds-averaged Navier-Stokes (RANS) numerical simulations. Both the experimental and computational results displayed a similar recirculation zone shape and normalized velocity profile near the duct outlet for the baseline geometry. To optimize the uniformity of the flow, the number of guide vanes was modified, and the guide vanes were partially extended straight upward. Design evaluation is done based on the outlet velocity distribution and mass flowrate balance between the two outlets. Simulation results indicate that the vane extension is critical for flow optimization in curved ESP ducts.