• 제목/요약/키워드: Magnetic Object

검색결과 219건 처리시간 0.027초

초음파를 이용한 광소자 이송시스템의 빔형상에 따른 이송특성에 관한 연구 (A Study on the Transportation Characteristics according to Beam Shape of Optical Lens Transport System using Ultrasonic Wave)

  • 정상화;최석봉;차경래;송석;김광호
    • 한국공작기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.8-14
    • /
    • 2006
  • The object transport system is used in many industry field such as the conveyor belt, which transports huge goods in container harbor, the magnetic levitation system, and the indexing system which transports precision components such as semiconductor and optical components. In conventional transport system, the magnetic field may damage semiconductor and the contact force may scratch on the optical lens. So ultrasonic wave transport system has been proposed to replace the previous transport system. In this paper, the good transport condition of optical lens is obtained according to the flexural beam shapes. The working frequency and transport speed are measured and the vibration characteristics of the flexural beams are investigated by Laser Scanning Vibrometer.

근접센서를 이용한 차량 도어 제어 충돌 방지 시스템 (Car-door-controlled collision protection system using proximity sensor)

  • 이석희;조한석;허종규;이정헌;김희국
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.971-975
    • /
    • 2005
  • In this study, a car-door-controlled collision protection system using proximity sensor is proposed and its preliminary analysis and several preliminary experiments are conducted. The proposed system has three additional sub-components on the car-door that is, a pair of extra electro-magnetic actuator that are attached to the sliding bar of the open/close car-door four-bar mechanism, a proximity sensor that would be attached to the outside surface of the door which is likely to frequently contact to the object and a driving control circuit of the whole system. A proximity sensor is used to detect object close to the car-door, the driving control circuit provides actuating power command to the electro-magnets to generate braking force to stop the swing motion of the car-door. It is verified through kinematic analysis of the four-bar car-door open/close mechanism and through experiments that the magnitude of maximum electronic magnetic force could provide the braking force enough for this application. For this purpose, an electro-magnet driving circuit is implemented and tested. And also to increase the safety of the system a time delay circuit is implemented and tested.

  • PDF

뼈모세포의 활성도에 대한 자성의 효과에 관한 연구 (The Effect of Magnetism(Neodymium Magnet) on Activity of Osteoblast)

  • 조영욱;최부병;이성복
    • 구강회복응용과학지
    • /
    • 제19권3호
    • /
    • pp.185-193
    • /
    • 2003
  • The object of this study is to observe the effects of magnetism on the osteoblasts using a neodymium magnet. The osteoblasts was cultured under magnetic fields of varying intensities to evaluate the effect of magnetism on the activity and alkaline phosphatase acitivty of the osteoblasts. Osteoblasts were cultured in the cell density of $10^4$ for the evaluation of cell proliferation and 105/ml for the evaluation of ALP activity under 0. 10, 100, 500, 1000, 2000, 4000 gauss for 24 hour. For evaluation of osteoblast morphologic changes under magnetic, osteoblasts were observed by inverted microscope and TEM. To elucidate if IGF-receptors are increased under the magnetic field, we investigated osteoblasts by immunofluoroscence staining. The results were as follows: In the varying intensities of magnetic fields, the degree of cell proliferation was the highest in the magnetic field of 10 gauss and this gradually decreased up to 1000 gauss. In the magnetic fields stronger than 1000 gauss, the degree of the cell proliferation decreased to an even lower level than that of the control group. The ALP activity and protein synthesis showed a similar increase pattern as the degree of cell proliferation compared to the control group but showed little difference. Under the microscope, morphological change of the cells ( decrease in length and increase in roundness) were observed but no peculiarity of cell distribution could be found according to the magnetic field line. In the proper intensity of magnetic fields (10 gauss), the cultured cells showed increase in number of IGF Receptors compared to that of the control group.

134.2kHz 대역의 RFID 루프안테나 설계에 관한 연구 (A Study on the 134.2kHz Band RFID(Radio Frequency Identification) Loop Antenna Design)

  • 강민수;이동선;이기서
    • 한국철도학회논문집
    • /
    • 제4권3호
    • /
    • pp.102-109
    • /
    • 2001
  • In this paper, it has a proposal of the RFID reader antenna design that expand the dedicated short-range communication distance between a static object on the ground and a mobile object attached on the moving article. The static reader equipped with micro-processor makes it possible to have a serial communication with a main system, so that much data can be transfer to the main system. An antenna is adjusted in order to a communication, the scale is designed by results values of simulation using matlab. It is achieved to systematically manage logistics, person resource and security system by grasping the information and location of mobile object on the basis that this system receives the information between a static reader and a mobile object tag at 134.2kHz band on real time, also to make it possible the main system to process. Therefore, the reader antenna scale is controlled on the foundation of a magnetic field theory in order to expand a recognition distance of reader and tag, so that can be optimistically recognized with minimizing the direction influence of reader and tag.

  • PDF

Magnetic Saturation Effect of the Iron Core in Current Transformers Under Lightning Flow

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권2호
    • /
    • pp.97-102
    • /
    • 2017
  • A current transformer (CT) is a type of sensor that consists of a combination of electric and magnetic circuits, and it measures large ac currents. When a large amount of current flows into the primary winding, the alternating magnetic flux in the iron core induces an electromotive force in the secondary winding. The characteristics of a CT are determined by the iron core design because the iron core is saturated above a certain magnetic flux density. In particular, when a large current, such as a current surge, is input into a CT, the iron core becomes saturated and the induced electromotive force in the secondary winding fluctuates severely. Under these conditions, the CT no longer functions as a sensor. In this study, the characteristics of the secondary winding were investigated using the time-difference finite element method when a current surge was provided as an input. The CT was modeled as a two-dimensional analysis object using constraints, and the saturation characteristics of the iron core were evaluated using the Newton-Rhapson method. The results of the calculation were compared with the experimental data. The results of this study will prove useful in the designs of the iron core and the windings of CTs.

자기 센서를 이용한 지하 매설물 탐지 시스템 개발 (Developement of Detection system of buried Underground Utilities using Magnetic Sensor)

  • 천세영;이영주;조현철;안태규;양순용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1819-1823
    • /
    • 2005
  • Incorrect information on public sites can cause serious problem. One of relevant countermeasures against this problem is to detect of buried underground utilities in real time. Although there have been several method to detect of buried underground utilities, such as investigating of gravity and elastic wave and electric field, they have not been so efficient tools. Because it is too expensive and difficult to use. In this paper, magnetic sensors which could provide an easier and more efficient method are used to detect of buried underground utilities. Also fluxgate method of self detection are used. Input signal is used $1\~10kHz$ frequency. Filtering and signal processing of output signal are used labview software. After experiment, detection system of buried underground utilities which used magnetic shows possibility of precise detecting of laying object based on theorectical analysis for electromagnetic field.

  • PDF

표적 탐지거리 향상을 위한 근접자기센서 송수신기 설계에 관한 연구 (A Study on Transmitter and Receiver Design of Proximity Magnetic Sensor for Enhancement of Target Detection Range)

  • 주혜선;정현주;양창섭;전재진
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1151-1158
    • /
    • 2011
  • Proximity magnetic sensor is able to detect the object target accurately in close range and it has been widely used in the underwater guided weapon system because there is no countermeasures from the target. In order to increase the damage of target by shock wave due to explosion of the underwater guided weapon system, the maximum detection range of the proximity magnetic sensor needs to be increased. In this paper, we describe the techniques of the optimum transmitting and receiving coils design using the Finite Element Method for the output power enhancement of the transmitter and the sensitivity improvement of the receiver. Finally, the proposed design techniques of the transmitter and the receiver were verified using a experimental setup and a prototype.

Chemical Shift Artifact Correction in MREIT

  • Minhas, Atul S.;Kim, Young-Tae;Jeong, Woo-Chul;Kim, Hyung-Joong;Lee, Soo-Yeol;Woo, Eung-Je
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.461-468
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

마이크로프로세서를 이용한 자기카메라 전용 임베디드형 AD 변환기 및 잡음 감소에 관한 연구 (A Study of the Exclusive Embedded A/D Converter Using the Microprocessor and the Noise Decrease for the Magnetic Camera)

  • 이진아;황지성;송하용
    • 비파괴검사학회지
    • /
    • 제26권2호
    • /
    • pp.99-107
    • /
    • 2006
  • 자기적인 방법을 이용한 비파괴검사는 강자성체 표면 및 표면 근방의 균열을 탐상하는데 매우 유용하다. 균열을 평가하기 위해서는 시험편상의 누설자속분포를 정량적으로 취득해야 한다. 자기카메라는 큰 리프트오프에서 누설자속분포를 얻기 위하여 제안되었다. 자기카메라는 지원, 자기렌즈, AD 변환기, 인터페이스 및 컴퓨터로 구성되어 있다. 측정 대상체로부터 누설된 자속 또는 흐트러진 자장은 지기렌즈로 집속된 후, 배열된 작은 지기센서에 의하여 아날로그신호로 변환된다. 이러한 아날로그 신호는 AD 변환기에 의하여 디지털신호로 변환되고, 인터페이스 및 컴퓨터에 의하여 저장, 영상화 및 처리된다. 그러나, 지급까지의 자기카메라는 범용 AD변환기를 사용하기 때문에 변환 및 스위칭속도, 검출범위 및 분해능, 직접 메모리 액세스(DMA, direct memory access), 임시저장속도 및 저장량에 한계점을 가지고 있었다. 또한, S/N비를 높이기 위하여 OP-AMP의 도입, 신호의 증폭, 배선의 감소, LPF의 사용과 팥은 개선된 기술이 필요하다. 본 논문은 상술한 조건들을 만족하기 위하여 OP-AMP, LPF, 마이크로프로세서 및 DMA 회로를 포함한 자기카메라 전용 임베디드형 AD 변환기를 제안한다.

Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System

  • Lee, Jung-Woo;Choe, Bo-Young;Choi, Chi-Bong;Huh, Soon-Nyoung
    • 한국자기공명학회논문지
    • /
    • 제9권1호
    • /
    • pp.48-60
    • /
    • 2005
  • Purpose: The purpose of this study was to design and build an optimized birdcage resonator configuration with a low pass filter, which would facilitate the acquisition of high-resolution 3D-image of small animals at 3T MRI system. Methods and Materials: The birdcage resonator with 12-element structures was built, in order to ensure B1 homogeneity over the image volume and maximum filling factor, and hence to maximize the signal to noise ratio (SNR) and resolution of the 3-dimensional images. The diameter and length of each element of a birdcage resonator were as follows: (1) diameter 13 cm, length 22 cm, (2) diameter 15 cm, length 22 cm, (3) diameter 17 cm, length 25 cm. Spin echo pulse sequence and fast spin echo pulse sequence were employed in obtaining MR images. The quality of the manufactured birdcage resonators wes evaluated on the basis of the return loss following matching and tuning process. Results: The experimental MR image of phantoms by the various manufactured birdcage resonators were obtained to compare the SNR in accordance with the size of objects. The size of an object to that of coil was identified by parameters that were estimated from the image of a phantom. First, the diameter of the birdcage resonator was 15cm, and the ratio of the tangerine to the birdcage resonator accounted for approximately 27%. The Q factor was 53.2 and the SNR was 150.7. Second, at the same birdcage resonator, the ratio of the orange was approximately 53%. The SNR and the Q parameter was 212.8 and 91.2, respectively. Conclusion: The present study demonstrated that if birdcage resonators have the same forms, SNR could be different depending on the size of an object, especially when the size of an object to that of coil is approximately 40~80%, the former is bigger than the latter. Therefore, when the size of an object to be observed is smaller than that of coil, the coil should be manufactured in accordance with the size of an object in order to obtain much more excellent images.

  • PDF