• Title/Summary/Keyword: Magnetic Object

Search Result 219, Processing Time 0.031 seconds

A Study on the Transportation Characteristics according to Beam Shape of Optical Lens Transport System using Ultrasonic Wave (초음파를 이용한 광소자 이송시스템의 빔형상에 따른 이송특성에 관한 연구)

  • Jeong, Sang-Hwa;Choi, Suk-Bong;Cha, Kyoung-Rae;Song, Suk;Kim, Gwang-Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.8-14
    • /
    • 2006
  • The object transport system is used in many industry field such as the conveyor belt, which transports huge goods in container harbor, the magnetic levitation system, and the indexing system which transports precision components such as semiconductor and optical components. In conventional transport system, the magnetic field may damage semiconductor and the contact force may scratch on the optical lens. So ultrasonic wave transport system has been proposed to replace the previous transport system. In this paper, the good transport condition of optical lens is obtained according to the flexural beam shapes. The working frequency and transport speed are measured and the vibration characteristics of the flexural beams are investigated by Laser Scanning Vibrometer.

Car-door-controlled collision protection system using proximity sensor (근접센서를 이용한 차량 도어 제어 충돌 방지 시스템)

  • Lee S.H.;Cho H.S.;Heo J.K.;Lee J.H.;Kim W.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.971-975
    • /
    • 2005
  • In this study, a car-door-controlled collision protection system using proximity sensor is proposed and its preliminary analysis and several preliminary experiments are conducted. The proposed system has three additional sub-components on the car-door that is, a pair of extra electro-magnetic actuator that are attached to the sliding bar of the open/close car-door four-bar mechanism, a proximity sensor that would be attached to the outside surface of the door which is likely to frequently contact to the object and a driving control circuit of the whole system. A proximity sensor is used to detect object close to the car-door, the driving control circuit provides actuating power command to the electro-magnets to generate braking force to stop the swing motion of the car-door. It is verified through kinematic analysis of the four-bar car-door open/close mechanism and through experiments that the magnitude of maximum electronic magnetic force could provide the braking force enough for this application. For this purpose, an electro-magnet driving circuit is implemented and tested. And also to increase the safety of the system a time delay circuit is implemented and tested.

  • PDF

The Effect of Magnetism(Neodymium Magnet) on Activity of Osteoblast (뼈모세포의 활성도에 대한 자성의 효과에 관한 연구)

  • Cho, Young-Wook;Choi, Boo-Byung;Lee, Seong-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.185-193
    • /
    • 2003
  • The object of this study is to observe the effects of magnetism on the osteoblasts using a neodymium magnet. The osteoblasts was cultured under magnetic fields of varying intensities to evaluate the effect of magnetism on the activity and alkaline phosphatase acitivty of the osteoblasts. Osteoblasts were cultured in the cell density of $10^4$ for the evaluation of cell proliferation and 105/ml for the evaluation of ALP activity under 0. 10, 100, 500, 1000, 2000, 4000 gauss for 24 hour. For evaluation of osteoblast morphologic changes under magnetic, osteoblasts were observed by inverted microscope and TEM. To elucidate if IGF-receptors are increased under the magnetic field, we investigated osteoblasts by immunofluoroscence staining. The results were as follows: In the varying intensities of magnetic fields, the degree of cell proliferation was the highest in the magnetic field of 10 gauss and this gradually decreased up to 1000 gauss. In the magnetic fields stronger than 1000 gauss, the degree of the cell proliferation decreased to an even lower level than that of the control group. The ALP activity and protein synthesis showed a similar increase pattern as the degree of cell proliferation compared to the control group but showed little difference. Under the microscope, morphological change of the cells ( decrease in length and increase in roundness) were observed but no peculiarity of cell distribution could be found according to the magnetic field line. In the proper intensity of magnetic fields (10 gauss), the cultured cells showed increase in number of IGF Receptors compared to that of the control group.

A Study on the 134.2kHz Band RFID(Radio Frequency Identification) Loop Antenna Design (134.2kHz 대역의 RFID 루프안테나 설계에 관한 연구)

  • 강민수;이동선;이기서
    • Journal of the Korean Society for Railway
    • /
    • v.4 no.3
    • /
    • pp.102-109
    • /
    • 2001
  • In this paper, it has a proposal of the RFID reader antenna design that expand the dedicated short-range communication distance between a static object on the ground and a mobile object attached on the moving article. The static reader equipped with micro-processor makes it possible to have a serial communication with a main system, so that much data can be transfer to the main system. An antenna is adjusted in order to a communication, the scale is designed by results values of simulation using matlab. It is achieved to systematically manage logistics, person resource and security system by grasping the information and location of mobile object on the basis that this system receives the information between a static reader and a mobile object tag at 134.2kHz band on real time, also to make it possible the main system to process. Therefore, the reader antenna scale is controlled on the foundation of a magnetic field theory in order to expand a recognition distance of reader and tag, so that can be optimistically recognized with minimizing the direction influence of reader and tag.

  • PDF

Magnetic Saturation Effect of the Iron Core in Current Transformers Under Lightning Flow

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.97-102
    • /
    • 2017
  • A current transformer (CT) is a type of sensor that consists of a combination of electric and magnetic circuits, and it measures large ac currents. When a large amount of current flows into the primary winding, the alternating magnetic flux in the iron core induces an electromotive force in the secondary winding. The characteristics of a CT are determined by the iron core design because the iron core is saturated above a certain magnetic flux density. In particular, when a large current, such as a current surge, is input into a CT, the iron core becomes saturated and the induced electromotive force in the secondary winding fluctuates severely. Under these conditions, the CT no longer functions as a sensor. In this study, the characteristics of the secondary winding were investigated using the time-difference finite element method when a current surge was provided as an input. The CT was modeled as a two-dimensional analysis object using constraints, and the saturation characteristics of the iron core were evaluated using the Newton-Rhapson method. The results of the calculation were compared with the experimental data. The results of this study will prove useful in the designs of the iron core and the windings of CTs.

Developement of Detection system of buried Underground Utilities using Magnetic Sensor (자기 센서를 이용한 지하 매설물 탐지 시스템 개발)

  • Cheon Y.S.;Lee J.Y.;Cho C.H.;Ahn K.T.;Yang S.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1819-1823
    • /
    • 2005
  • Incorrect information on public sites can cause serious problem. One of relevant countermeasures against this problem is to detect of buried underground utilities in real time. Although there have been several method to detect of buried underground utilities, such as investigating of gravity and elastic wave and electric field, they have not been so efficient tools. Because it is too expensive and difficult to use. In this paper, magnetic sensors which could provide an easier and more efficient method are used to detect of buried underground utilities. Also fluxgate method of self detection are used. Input signal is used $1\~10kHz$ frequency. Filtering and signal processing of output signal are used labview software. After experiment, detection system of buried underground utilities which used magnetic shows possibility of precise detecting of laying object based on theorectical analysis for electromagnetic field.

  • PDF

A Study on Transmitter and Receiver Design of Proximity Magnetic Sensor for Enhancement of Target Detection Range (표적 탐지거리 향상을 위한 근접자기센서 송수신기 설계에 관한 연구)

  • Ju, Hye-Sun;Chung, Hyun-Ju;Yang, Chang-Seob;Jeon, Jae-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1151-1158
    • /
    • 2011
  • Proximity magnetic sensor is able to detect the object target accurately in close range and it has been widely used in the underwater guided weapon system because there is no countermeasures from the target. In order to increase the damage of target by shock wave due to explosion of the underwater guided weapon system, the maximum detection range of the proximity magnetic sensor needs to be increased. In this paper, we describe the techniques of the optimum transmitting and receiving coils design using the Finite Element Method for the output power enhancement of the transmitter and the sensitivity improvement of the receiver. Finally, the proposed design techniques of the transmitter and the receiver were verified using a experimental setup and a prototype.

Chemical Shift Artifact Correction in MREIT

  • Minhas, Atul S.;Kim, Young-Tae;Jeong, Woo-Chul;Kim, Hyung-Joong;Lee, Soo-Yeol;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

A Study of the Exclusive Embedded A/D Converter Using the Microprocessor and the Noise Decrease for the Magnetic Camera (마이크로프로세서를 이용한 자기카메라 전용 임베디드형 AD 변환기 및 잡음 감소에 관한 연구)

  • Lee, Jin-Yi;Hwang, Ji-Seong;Song, Ha-Ryong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.99-107
    • /
    • 2006
  • Magnetic nondestructive testing is very useful far detecting a crack on the surface or near of the surface of the ferromagnetic materials. The distribution of the magnetic flux leakage (DMFL) on a specimen has to be obtained quantitatively to evaluate the crack. The magnetic camera is proposed to obtain the DMFL at the large lift-off. The magnetic camera consists of a magnetic source, magnetic lens, analog to digital converters (ADCs), interface, and computer. The magnetic leakage fields or the distorted magnetic fields from the object, which are concentrated on the magnetic lens, are converted to analog electrical signals tv arrayed small magnetic sensors. These analog signals are converted to digital signals by the ADCs, and are stored, imaged, and processed by the interface and computer. However the magnetic camera has limitations with respect to converting and switching speed, full range and resolution, direct memory access (DMA), temporary storage speed and volume because common ADCs were used. Improved techniques, such as those that introduce the operational amplifier (OP-Amp), amplify the signal, reduce the connection line, and use the low pass filter (LPF) to increase the signal to noise ratio are necessary. This paper proposes the exclusive embedded ADC including OP-Amp, LPF, microprocessor and DMA circuit for the magnetic camera to satisfy the conditions mentioned above.

Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System

  • Lee, Jung-Woo;Choe, Bo-Young;Choi, Chi-Bong;Huh, Soon-Nyoung
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.1
    • /
    • pp.48-60
    • /
    • 2005
  • Purpose: The purpose of this study was to design and build an optimized birdcage resonator configuration with a low pass filter, which would facilitate the acquisition of high-resolution 3D-image of small animals at 3T MRI system. Methods and Materials: The birdcage resonator with 12-element structures was built, in order to ensure B1 homogeneity over the image volume and maximum filling factor, and hence to maximize the signal to noise ratio (SNR) and resolution of the 3-dimensional images. The diameter and length of each element of a birdcage resonator were as follows: (1) diameter 13 cm, length 22 cm, (2) diameter 15 cm, length 22 cm, (3) diameter 17 cm, length 25 cm. Spin echo pulse sequence and fast spin echo pulse sequence were employed in obtaining MR images. The quality of the manufactured birdcage resonators wes evaluated on the basis of the return loss following matching and tuning process. Results: The experimental MR image of phantoms by the various manufactured birdcage resonators were obtained to compare the SNR in accordance with the size of objects. The size of an object to that of coil was identified by parameters that were estimated from the image of a phantom. First, the diameter of the birdcage resonator was 15cm, and the ratio of the tangerine to the birdcage resonator accounted for approximately 27%. The Q factor was 53.2 and the SNR was 150.7. Second, at the same birdcage resonator, the ratio of the orange was approximately 53%. The SNR and the Q parameter was 212.8 and 91.2, respectively. Conclusion: The present study demonstrated that if birdcage resonators have the same forms, SNR could be different depending on the size of an object, especially when the size of an object to that of coil is approximately 40~80%, the former is bigger than the latter. Therefore, when the size of an object to be observed is smaller than that of coil, the coil should be manufactured in accordance with the size of an object in order to obtain much more excellent images.

  • PDF