• Title/Summary/Keyword: Magnetic Motion

Search Result 716, Processing Time 0.026 seconds

Parallel Load Techinques Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.27-32
    • /
    • 2012
  • Transcranial magnetic stimulation requires an electric field composed of dozens of V/m to achieve stimulation. The stimulation system is composed of a stimulation coil to form the electric field by charging and discharging a capacitor in order to save energy, thus requiring high-pressure kV. In particular, it is charged and discharged in capacitor to discharge through stimulation coil within a short period of time (hundreds of seconds) to generate current of numerous kA. A pulse-type magnetic field is formed, and eddy currents within the human body are triggered to achieve stimulation. Numerous pulse forms must be generated to initiate eddy currents for stimulating nerves. This study achieved high internal pressure, a high number of repetitions, and rapid switching of elements, and it implemented numerous control techniques via introduction of the half-bridge parallel load method. In addition it applied a quick, accurate, high-efficiency charge/discharge method for transcranial magnetic stimulation to substitute an inexpensive, readily available, commercial frequency condenser for a previously used, expensive, high-frequency condenser. Furthermore, the pulse repetition rate was altered to control energy density, and grafts compact, one-chip processor with simulation to stably control circuit motion and conduct research on motion and output characteristics.

Development of a Noncontacting 6 DOF Micro-Postioner Driven by Magnetic Force-Design, Modeling and Control- (자기력을 이용한 비접촉 6자유도 미소위치결정 기구의 개발-설계, 모델링 및 제어-)

  • Choi, Kee-Bong;Park, Kyi-Hwan;Kim, Soo-Hyun;Kwak, Yoon-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1164-1176
    • /
    • 1996
  • A magnetically levitated micro-positioner is implemented to avoid mechanical friction and increase precision. Since magnetic levitation system is inherently unstable, most concern is focused on a magnetic circuit design to increase the system dynamic stability. For this, the proposed levitation system is constructed by using an antagonistic structure which permits a simple design and robust stability. From the dynamic equations of motion, it is verified that the proposed magnetically levitated system is decoupled in 6 degree-of-freedom motion. Experimental results are presented in terms of time response and accuracy.

Dynamic analysis of functionally graded (FG) nonlocal strain gradient nanobeams under thermo-magnetic fields and moving load

  • Alazwari, Mashhour A.;Esen, Ismail;Abdelrahman, Alaa A.;Abdraboh, Azza M.;Eltaher, Mohamed A.
    • Advances in nano research
    • /
    • v.12 no.3
    • /
    • pp.231-251
    • /
    • 2022
  • Dynamic behavior of temperature-dependent Reddy functionally graded (RFG) nanobeam subjected to thermomagnetic effects under the action of moving point load is carried out in the present work. Both symmetric and sigmoid functionally graded material distributions throughout the beam thickness are considered. To consider the significance of strain-stress gradient field, a material length scale parameter (LSP) is introduced while the significance of nonlocal elastic stress field is considered by introducing a nonlocal parameter (NP). In the framework of the nonlocal strain gradient theory (NSGT), the dynamic equations of motion are derived through Hamilton's principle. Navier approach is employed to solve the resulting equations of motion of the functionally graded (FG) nanoscale beam. The developed model is verified and compared with the available previous results and good agreement is observed. Effects of through-thickness variation of FG material distribution, beam aspect ratio, temperature variation, and magnetic field as well as the size-dependent parameters on the dynamic behavior are investigated. Introduction of the magnetic effect creates a hardening effect; therefore, higher values of natural frequencies are obtained while smaller values of the transverse deflections are produced. The obtained results can be useful as reference solutions for future dynamic and control analysis of FG nanobeams reinforced nanocomposites under thermomagnetic effects.

Brain Activation During the Wrist Movement Using Symmetrical Upper Limb Motion Trainer (대칭형 상지 운동기구를 이용한 손목 운동 시 뇌 활성도 패턴)

  • 태기식;김사엽;송성재;이소영;박기영;손철호;김영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1303-1306
    • /
    • 2004
  • We developed a symmetrical upper limb motion trainer for chronic hemiparetic subjects. This trainer enabled the practice of a forearm pronatio $n^ination and wrist flexion/extension. In this study, we have used functional magnetic resonance imaging(fMRI) with the developed symmetrical upper limb motion device, to compare brain activation patterns elicited by flexion/extension wrist movements of control and hemiparetic subject group. In control group, contralateral somatosensory cortex(SMC) and bilateral cerebellum were activated by dominant hand movement(Task 1), while bilateral movements by dominant hand(Task 2) activated the SMC in both cerebral hemispheres and ipsilateral cerebellum. However, in hemiparetic subject group, contralateral supplymentary motor area(SMA) was activated by unaffected hand movement(Task 1), while the activation of bilateral movements by unaffected hand(Task 2) showed only SMA in the undamaged hemisphere. This study, demonstrating the ability to accurately measure activation in both sensory and motor cortex, is currently being extended to patients in clinical applications such as the recovery of motor function after stroke.ke.

  • PDF

The Effect of Roll and Pitch Motion on Ship Magnetic Signature

  • Birsan, Marius;Tan, Reinier
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.503-508
    • /
    • 2016
  • The roll- and pitch-induced eddy currents create a magnetic field that contributes to the total magnetic signature of naval vessels. The magnetic signature is of concern, as it exposes the ship to the threat of modern influence mines. It is estimated that the eddy current is the second most important source contributing to a ship's underwater magnetic field following the ferromagnetic effect. In the present paper, the finite element (FE) method is used to predict the eddy current signature of a real ship. The FE model is validated using the measurements of the Canadian research vessel CFAV QUEST at the Earth's Field Simulator (EFS) in Schirnau, Germany. Modeling and validation of the eddy current magnetic signature for a real ship represents a novelty in the field. It is shown that the characteristics of this signature depend on frequency. Based on these results, a ship's degaussing system could be improved to cancel both the ferromagnetic and the eddy current contribution to the magnetic signature simultaneously, reducing the susceptibility to sea mines.

Effects of Magnitic Field on Electrochemical Polishing Process (자기장이 전해복합연마공정에 미치는 영향)

  • 김정두;최민석;김동섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.108-112
    • /
    • 1994
  • The paper describes the effects of magnetic field on the electrochemical polishing process in the view of ionic in the electrolyte. Theoretical background was suggested how magnetic field increases the material removal efficiency and surface finishing ability Magnetic field changes the jonic movement in the electrolyte from linear motion to curved or complex oscillating one, thus increases the electrolytic current density and, as the results, the finishing efficiency.

  • PDF

Development of Stroke Sensing Cylinder Using Magnetic Sensor and Its Performance Estimation (자기 센서를 이용한 스트로크 센싱 실린더의 개발 및 성능평가)

  • 홍영호;이민철;이만형;양순용;진영일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.278-282
    • /
    • 1995
  • We developed a part of storke sensing cylinder using magnetic sensor and estimated is performance. In this paper, for the performance estimation of stroke sensing cylinder. We consist of hydrallic system using solenoid valve with ON/OFF motion. In order to the control of solenoid valve for the position control of cylinder rod, PWM (Pulse Width Modulation) method which modulates time pulse width in proportion to error was used. A performance of cylinder rod with magnetic scales was evaluated by its hydraulic system.

  • PDF

Sliding Mode Control with Disturbance Observer for An Active Magnetic Bearing System (자기베어링계에서 외란 관측기를 갖는 슬라이딩모드 제어)

  • 강민식
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.6
    • /
    • pp.408-414
    • /
    • 2004
  • In this paper, a disturbance observer based sliding mode control is proposed to attenuate disturbance responses in an active magnetic bearing system, which is subject to base motion. An algorithm which decouples disturbance observation dynamics from sliding mode dynamics is suggested. This algorithm preserves the robustness of the sliding mode control and satisfies reachability condition in the presence of external disturbance and parameter uncertainties. Along with experimental results, it is shown that the proposed control is effective in disturbance rejection without any additive disturbance measurement.

The Operating Characteristic Analysis of PM-type Magnetic Circuit Breaker (영구자석형 차단기 조작기의 동작 특성 해석)

  • Jun, Hee-Deuk;Woo, Kyung-Il;Kim, Byung-Taek;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.253-255
    • /
    • 2000
  • This paper describes the operating characteristic analysis of PM-type magnetic circuit breaker for electromagnetic field, electric circuit and mechanical motion problems. Transient calculations based up 2D finite element magnetic field solution including non-linearity of materials. Change of dynamic characteristic from eddy current in mover is quantified from FEM analysis.

  • PDF