해상풍력단지에서의 PMSG 풍력발전기를 활용한 계통연계점 불평형 전원 보상 (Compensation of Unbalanced PCC Voltage in an Off-shore Wind Farm of PMSG Type Turbines)

  • 강자윤;한대수;서용석;정병창;김정중;박종형;최영준
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.1-10
    • /
    • 2015
  • This paper proposes a control algorithm for permanent magnet synchronous generators with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage off-shore wind power system under unbalanced grid conditions. Specifically, the proposed control algorithm compensates for unbalanced grid voltage at the PCC (Point of Common Coupling) in a collector bus of an off-shore wind power system. This control algorithm has been formulated based on symmetrical components in positive and negative synchronous rotating reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power is described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of AC input current is injected into the PCC in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm enables the provision of balanced voltage at the PCC resulting in the high quality generated power from off-shore wind power systems under unbalanced network conditions.

Triode magnetron sputtering system의 제작 및 특성평가 (Characteristic evaluations and production of triode magnetron sputtering system)

  • 김현후;이무영;김광태;윤상현;유환구;김종민;박철현;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.787-790
    • /
    • 2003
  • A rf triode magnetron sputtering system is designed and installed its construction in vacuum chamber. In order to calibrate the rf triode magnetron sputtering for thin films deposition processes, the effects of different glow discharge conditions were investigated in terms of the deposition rate measurements. The basic parameters for calibrating experiment in this sputtering system are rf power input, gas pressure, plasma current, and target-to-substrate distance. Because a knowledge of the deposition rate is necessary to control film thickness and to evaluate optimal conditions which are an important consideration in preparing better thin films, the deposition rates of copper as a testing material under the various sputtering conditions are investigated. Furthermore, a triode sputtering system designed in our team is simulated by the SIMION program. As a result, it is sure that the simulation of electron trajectories in the sputtering system is confined directly above the target surface by the force of $E{\times}B$ field. Finally, some teats with the above 4 different sputtering conditions demonstrate that the deposition rate of rf triode magnetron sputtering is relatively higher than that of the conventional sputtering system. This means that the higher deposition rate is probably caused by a high ion density in the triode and magnetron system. The erosion area of target surface bombarded by Ar ion is sputtered widely on the whole target except on both magnet sides. Therefore, the designed rf triode magnetron sputtering is a powerful deposition system.

  • PDF

기판 부근의 자기장이 RF 스퍼터링법으로 증착된 ITO 박막의 특성에 미치는 영향 (Influence of Magnetic Field Near the Substrate on Characteristics of ITO Film Deposited by RF Sputtering Method)

  • 김현수;장호원;강종윤;김진상;윤석진;김창교
    • 한국전기전자재료학회논문지
    • /
    • 제25권7호
    • /
    • pp.563-568
    • /
    • 2012
  • Indium tin oxide (ITO) films were prepared using radio frequency (RF) magnetron sputtering method, magnets were equipped near the target in the sputter to bring the plasma near the target. The effect of magnetic field that brings the plasma near the substrate was compared with that of substrate heating. The effect of substrate heating on the grain size of the ITO thin film was larger than that of the magnetic field. However, the grain size of the ITO thin film was larger when the magnetic field was applied near the substrate during the sputtering process than when the substrate was not heated and the magnetic field was not applied. If stronger magnetic field is applied near the substrate during sputtering, it can be expected that the ITO thin film with good electrical conductivity and high transparency is obtained at low substrate temperature. When magnetic field of 90 Gauss was applied near the substrate during sputtering, the mobility of the ITO thin film increased from 15.2 $cm^2/V.s$ to 23.3 $cm^2/V.s$, whereas the sheet resistivity decreased from 7.68 ${\Omega}{\cdot}cm$ to 5.11 ${\Omega}{\cdot}cm$.

초전도 HGMS 자기분리에 의한 제지폐수의 정수처리 (Purification of Paper Factory's Wastewater by Superconducting HGMS)

  • 하동우;김태형;백승규;오상수;하홍수;고락길;김호섭;김영훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.41-41
    • /
    • 2008
  • 제지산업은 다량의 용수를 사용하면서 또한 많은 양의 폐수를 배출하고 있다. 기존의 폐수처리 공정에서는 침전처리를 위한 큰 저수조와 오랜 침강 시간이 요구되어 제한된 공장 내에서의 처리에 어려움이 많다. 이러한 기존 기술의 문제점을 보완하면서도 새로운 고도처리가 가능한 초전도 마그네트를 이용한 자기분리 기술을 적용하고자 하였다. 자기문리의 기본 원리는 강력한 자기력에 의하여 액체에 포함된 자성입자를 분리해내는 것으로 자성입자들이 자계의 힘에 의하여 잡아당겨지고 포획됨으로서 제거되는 것이다. 자기분리용 솔레노이드 마그네트로 초전도마그네트를 적용하게 되면 아주 높은 고구배의 자장(HGMS; High Gradient Magnetic Separation) 을 발생시킬 수 있다. 초전도마그네트와 체(sieve) 형 자기필터를 이용하면 대공간에 전력손실 없이 고자장을 발생시킬 수 있기 때문에 미립자를 효과적으로 고속으로 분리하는 것이 가능해지며 또한 상자성 미세입자까지도 처리할 수 있다. 본 연구에서는 주로 유기물로 구성된 제지며|수의 부유물을 자성체와의 응집반응에 의해 플록을 형성하여 자성 플록의 자기분리 효과를 연구하였다. 자성응집반응의 특성을 평가하기 위하여 전자석 시스템을 제작하였으며 배치타입의 자기필터를 설계 제작하였다. 또한 응집제의 종류와 응집반응 공정에 따른 자성플록의 형성 정도를 조사하였으며 자기분리 후 폐수의 탁도, SS 등의 특성을 분석하였다. 그림 1은 자성응집반응의 특성을 평가하기 위하여 제작한 전자석 시스템을 나타내고 있으며 전자석의 자장해석 결과를 보이고 있다.

  • PDF

플라즈마발생기의 이온분율 측정 장치 설계 및 제작 (The design and fabricationt for ion fraction measurement of plasma generator)

  • 이찬영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

  • Lee, Eunjee;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.14-21
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS. The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in overdenture sample and the abutment keeper in a mandibular model. Dislodging forces were applied to the overdenture samples (50.0 mm/min) in 3 directions. The loading was repeated 10 times in each direction. The values of dislodging force were analyzed statistically using SPSS at 95% level of confidence. RESULTS. The retentive force of group 2 was greater than that of group 1 in both types of attachment in every direction (P < .05). Oblique retentive force of flat type magnetic attachment was higher than that of cushion type attachment in both groups (P < .05). In group 1, oblique retentive force showed the highest and anterior-posterior retentive force showed the lowest value in both attachment types (P < .05). In group 2, both types of attachment showed the lowest retentive force with anterior-posterior direction of dislodging force (P <.05). CONCLUSION. Proper retentive properties for implant overdenture were obtained, regardless of the number and type of magnetic attachment. In both types of magnetic attachment, the greater retentive force was attained with more implants. Oblique retentive force of flat type magnetic attachment was greater than that of cushion type. Among all subgroups, anterior-posterior retentive force was the lowest among three different directions of dislodging force.

고(高)에너지 전자선(電子線) 치료(治療)를 위(爲)한 선량분포(線量分布) 및 기술적(技術的) 문제(問題)의 연구(硏究) (Studies on Dose Distribution and Treatment Technique of High Energy Electron)

  • 이도행;추성실
    • Journal of Radiation Protection and Research
    • /
    • 제3권1호
    • /
    • pp.6-22
    • /
    • 1978
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefor, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed doses, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under 3% errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under 5% errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatterers; ie., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

노선버스용 구동모터 시스템의 성능평가 (Assessment of Performance of Motor System for City Bus)

  • 이윤기;명광재
    • 대한기계학회논문집B
    • /
    • 제35권2호
    • /
    • pp.189-196
    • /
    • 2011
  • 최근, 승용차는 물론 대형차에서도 하이브리드시스템 등의 전기동력방식을 도입하려는 연구개발이 활발하다. 기존의 내연기관을 대체하는 전기구동모터를 이용하여 차량을 구동하는 전기동력방식을 채용하는 것이 한층 더 효율적이며 가속성능, 승차감 등의 면에서도 유리한 점이 많다. 그러나 모터는 엔진과 전혀 다른 특징을 갖기 때문에 동력성능과 에너지효율에 관한 적합한 평가수법을 검토할 필요가 있다. 본 논문에서는 전기구동버스에 대한 구동모터 시스템을 다이나모미터 상에서 운전하여, 노선버스의 운행패턴을 반영한 모의운전을 실시, 가속성능 및 에너지변환효율, 회생효과의 평가방법 등을 고찰하였다. 그 결과 실 주행 패턴운전에 대한 모터일률, 전력량 등의 계측으로부터 모터 변환효율은 90% 전후, 회생전력량은 요구전력량의 40% 이상으로 평가되었다.

CF8M 스테인리스 강 저주기 환경피로 실험의 주기적 변형률 경화 특성 (Characteristics of the Cyclic Hardening in Low Cycle Environmental Fatigue Test of CF8M Stainless Steel)

  • 정일석;하각현;김태룡;전현익
    • 대한기계학회논문집A
    • /
    • 제32권2호
    • /
    • pp.177-185
    • /
    • 2008
  • Low-cycle environmental fatigue tests of cast austenitic stainless steel CF8M at the condition of fatigue strain rate 0.04%/sec were conducted at the pressure and temperature, 15MPa, $315^{\circ}C$ of a operating pressurized water reactor (PWR). The used test rig was limited to install an extensometer at the gauge length of the cylindrical fatigue specimen inside a small autoclave. So the magnet type LVDT#s were used to measure the fatigue displacement at the specimen shoulders inside the high temperature and high pressure water autoclave. However, the displacement and strain measured at the specimen shoulders is different from the one at the gauge length for the geometry and the cyclic strain hardening effect. Displacement of the fatigue specimen gauge length calculated by FEM (finite element method) used to modify the measured displacement and fatigue life at the shoulders. A series of low cycle fatigue life tests in air and PWR conditions simulating the cyclic strain hardening effect verified that the FEM modified fatigue life was well agreed with the simulating test results. The process and method developed in this study for the environmental fatigue test inside the small sized autoclave would be so useful to produce reliable environmental fatigue curves of CF8M stainless steel in pressurized water reactors.

듀얼 서보모터 구동형 프레스 시스템의 동기화 제어기법 연구 (A Study on Synchronization Control Technique of Dual-Servo Press System)

  • 나상건;권오신;강재훈;허훈
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.206-215
    • /
    • 2013
  • In this paper, a synchronization control technique of dual-servo motor driven press system is proposed. An independent cascade PID control technique has been applied to the conventional press system for advancement of control stability. However, it is not easy to reduce synchronous error using the independent cascade PID control technique when some different load disturbances are involved in each motor. The eccentric error of the slide caused by the problem degrade the control performance of the BDC(Bottom Dead Center). In order to achieve reduction of the synchronous error between two servo motors and accurate position control simultaneously, a new control scheme comprised with cascade PID control loop and cross-coupling loop is proposed. In simulation using Matlab SIMULINK, the AC servo system is designed. The control performance of proposed technique is compared with conventional control technique to the model of AC servo system. Also, the sub-scale model of dual-servo motor driven press system which can replicate the slide motion is constructed for experimental verification for the performance of the proposed control technique. The cross-coupling control technique reveals more precise and stable performances in the position and synchronization controls.