• 제목/요약/키워드: Machine property

검색결과 468건 처리시간 0.032초

디자인의 형태와 기능에 관한 연구 (Essay on Form and Function Design)

  • 이재국
    • 디자인학연구
    • /
    • 제2권1호
    • /
    • pp.63-97
    • /
    • 1989
  • There is nothing more important than the form and function in design, because every design product can be done on the basis of them. Form and Function are already existed before the word of design has been appeared and all the natural and man-made things' basic organization is based on their organic relations. The organic relations is the source of vitality which identifies the subsistance of all the objects and the evolution of living creatures has been changed their appearances by the natural law and order. Design is no exception. Design is a man-made organic thing which is developed its own way according to the purposed aim and given situations. If so, what is the ultimate goal of design. It is without saying that the goal is to make every effort to contribute to the -human beings most desirable life by the designer who is devoting himself to their convenience and well-being. Therefore, the designer can be called the man of rich life practitioner. This word implies a lot of meanings since the essence of design is improving the guality of life by the man-made things which are created by the designer. Also, the things are existed through the relations between form and function, and the things can keep their value when they are answered to the right purpose. In design, thus, it is to be a main concern how to create valuable things and to use them in the right way, and the subject of study is focused on the designer's outlook of value and uk relations between form and function. Christopher Alexander mentioned the importance of form as follows. The ultimate object of design is form. Every design problem begins with an effort to achieve fittness between the form and its context. The form is the solution to the problem: the context defmes the problem. In other words, when we speak of design, the real object of discussion is not form alone, but the ensemble comprising the form and its context. Good fit is a desirable property of this ensemble which relates to some particular division of the ensemble into form and context. Max Bill mainatined how important form is in design. Form represents a self-contained concept, and its embodiment in an object results in that object becoming a work of art. Futhermore, this explains why we use form so freguently in a comparative sense for determining whether one thing is less or more beautiful than another, and why the ideal of absolute beauty is always the standard by which we appraise form, and through form, art itself. Hence form has became synonymous with beauty. On the other hand, Laszlo Moholy-Nagy stated the importance of function as follows. Function means the task an object is designed to fulfill the task instrument is shaping the form. Unfortunately, this principle was not appreciated at the same time but through the endeavors of Frank Lloyd Wright and of the Bauhaus group and its many collegues in Europe, the idea of functionalism became the keynote of the twenites. Functionalism soon became a cheap slogan, however, and its original meaning blurred. It is neccessary to reexamine it in the light of present circumstances. Charles William Eliot expressed his idea on the relations between function and beauty. Beauty often results chiefly from fittness: indeed it is easy to manitain that nothing is fair except what is fit its uses or functions. If the function of the product of a machine be useful and valuable, an the machine be eminently fit for its function, it conspicuously has the beauty of fittness. A locomotive or a steamship has the same sort of beauty, derived from the supreme fittness for its function. As functions vary, so will those beauty..vary. However, it is impossible to study form and function in separate beings. Function can't be existed without form, and without function, form is nothing. In other words, form is a function's container, and function is content in form. It can be said that, therefore, the form and function are indispensable and commensal individuals which have coetemal relations. From the different point of view, sometimes, one is more emphasized than the other, but in this case, the logic is only accepted on the assumption of recognizing the importance of the other's entity. The fact can be proved what Frank Hoyd wright said that form and function are one. In spite of that, the form and function should be considered as independent indivisuals, because they are too important to be treated just as the simple single one. Form and function have flexible properties to the context. In other words, the context plays a role as the barometer to define the form and function, also which implies every meaning of surroun'||'&'||'not;dings. Thus, design is formed under the influence of situations. Situations are dynamic, like the design process itself, in which fixed focus can be cripping. Moreover, situations control over making the good design. Judging from the respect, I defined the good design in my thesis An Analytic Research on Desigh Ethic, "good design is to solve the problem by the most proper way in the situations." Situations are changeable, and so is design. There is no progress without change, but change is not neccessarily progress. It is highly desirable that there changes be beneficial to mankind. Our main problem is to be able to discriminate between that which should be discarded and that which should be kept, built upon, and improved. Form and Function are no exception. The practical function gives birth to the inevitable form and the $$\mu$ti-classified function is delivered to the varieties of form. All of these are depended upon changeable situations. That is precisely the situations of "situation de'||'&'||'not;sign", the concept of moving from the design of things to the design of the circumstances in which things are used. From this point of view, the core of form and function is depended upon how the designer can manage it efficiently in given situations. That is to say that the creativity designer plays an important role to fulfill the purpose. Generally speaking, creativity is the organization of a concept in response to a human need-a solution that is both satisfying and innovative. In order to meet human needs, creative design activities require a special intuitive insight which is set into motion by purposeful imagination. Therefore, creativity is the most essential quality of every designer. In addition, designers share with other creative people a compulsive ingenuity and a passion for imaginative solutions which will meet their criteria for excellence. Ultimately, it is said that the form and function is the matter which belongs to the desire of creative designers who constantly try to bring new thing into being to create new things. In accordance with that the main puppose of this thesis is to catch every meaning of the form and function and to close analyze their relations for the promotion of understanding and devising practical application to gradual progression in design. The thesis is composed of four parts: Introduction, Form, Function and Conclusion. Introduction, the purpose and background of the research are presented. In Chapter I, orgin of form, perception of form, and classification of form are studied. In Chapter II, generation of function, development of function, and diversification of function are considered. Conclusion, some concluding words are mentioned.ioned.

  • PDF

납착 방법이 치과용 금속의 성상(性狀)에 미치는 영향에 관한 연구 (Study on the effect of soldering methods on the characteristics of the Ni-Cr alloy)

  • 김철형;송영균;이종혁
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.53-60
    • /
    • 2012
  • 연구 목적: 본 연구는 치과영역에서 많이 사용되는 비귀금속 합금인 니켈-크롬 합금을 산소-아세틸렌 불꽃 납착법과 적외선 용접법을 이용해 용접하고 용접부 및 그 주변을 광학 현미경과 EPMA (Electron Probe Micro Analyzer, 전자미세현미분석기)를 통해 관찰하여 용접방법이 금속의 성상(性狀)에 미치는 영향을 조사하였다. 연구 재료 및 방법: 니켈-크롬 합금을 이용하여 3.0 mm 직경, 30 mm 길이의 시편을 제작하였다. 시편은 산소-아세틸렌 불꽃 납착법, 적외선 용접법의 두 개의 그룹으로 분류하였다(n=4). 시편을 low-speed disc로 자른 후 각각을 산소-아세틸렌 토치와 적외선 용접기를 이용해 용접하였다. 용접과 마무리 후에 시편을 광학현미경으로 용접부, 5 mm 떨어진 지점, 10 mm 떨어진 지점의 3개 부위에서 관찰하고EPMA를 이용하여 분석하였다. 결과: 광학 현미경 관찰 결과 용접부에서는 두 방법 모두 다수의 파절선이 관찰되었고, 10.0 mm 떨어진 거리에서는 두 방법 모두 시편의 표면에서 파절선이 발견되지 않았으나 5.0 mm 떨어진 거리에서는 적외선 용접법에서는 시편의 표면이 다소 거칠기는 했으나 파절선은 발견되지 않았고 산소-아세틸렌 불꽃 납착 표면에서는 다수의 파절선이 관찰되었다. EPMA분석에서 적외선 용접법에 의한 방법에서는 용접부위, 5.0 mm 떨어진 부위, 10.0 mm 떨어진 부위 모두에서 시편 금속의 구성성분 비율이 제조사의 구성성분 비율과 10.0%이내의 오차를 나타내었고, 산소-아세틸렌 불꽃 납착법에서는 5.0, 10.0 mm에서는 시편금속의 구성성분이 10.0%이내의 오차를 나타내었으나, 납착 부위에서는 Ni만이 검출되어 적외선 용접법과는 차이를 나타내었다. 이와 같은 분석결과를 살펴 볼 때 적외선 용접을 시행한 시편의 구성 성분이 모금속의 성분과 유사한 것 을알수있었다. 결론: 이상의 결과로 산소-아세틸렌 불꽃 납착법보다 적외선 용접법을 이용할 때, 금속의 결함 및 성분의 변화가 적어서 좀 더 우수한 금속 보철물의 제작이 가능할 것으로 사료된다.

한국표준산업분류를 기준으로 한 문서의 자동 분류 모델에 관한 연구 (A Study on Automatic Classification Model of Documents Based on Korean Standard Industrial Classification)

  • 이재성;전승표;유형선
    • 지능정보연구
    • /
    • 제24권3호
    • /
    • pp.221-241
    • /
    • 2018
  • 지식사회에 들어서며 새로운 형태의 자본으로서 정보의 중요성이 강조되고 있다. 그리고 기하급수적으로 생산되는 디지털 정보의 효율적 관리를 위해 정보 분류의 중요성도 증가하고 있다. 본 연구에서는 기업의 기술사업화 의사결정에 도움이 될 수 있는 맞춤형 정보를 자동으로 분류하여 제공하기 위하여, 기업의 사업 성격을 나타내는 한국표준산업분류(이하 'KSIC')를 기준으로 정보를 분류하는 방법을 제안하였다. 정보 혹은 문서의 분류 방법은 대체로 기계학습을 기반으로 연구되어 왔으나 KSIC를 기준으로 분류된 충분한 학습데이터가 없어, 본 연구에서는 문서간 유사도를 계산하는 방식을 적용하였다. 구체적으로 KSIC 각 코드별 설명문을 수집하고 벡터 공간 모델을 이용하여 분류 대상 문서와의 유사도를 계산하여 가장 적합한 KSIC 코드를 제시하는 방법과 모델을 제시하였다. 그리고 IPC 데이터를 수집한 후 KSIC를 기준으로 분류하고, 이를 특허청에서 제공하는 KSIC-IPC 연계표와 비교함으로써 본 방법론을 검증하였다. 검증 결과 TF-IDF 계산식의 일종인 LT 방식을 적용하였을 때 가장 높은 일치도를 보였는데, IPC 설명문에 대해 1순위 매칭 KSIC의 일치도는 53%, 5순위까지의 누적 일치도는 76%를 보였다. 이를 통해 보다 정량적이고 객관적으로 중소기업이 필요로 할 기술, 산업, 시장정보에 대한 KSIC 분류 작업이 가능하다는 점을 확인할 수 있었다. 또한 이종 분류체계 간 연계표를 작성함에 있어서도 본 연구에서 제공하는 방법과 결과물이 전문가의 정성적 판단에 도움이 될 기초 자료로 활용될 수 있을 것으로 판단된다.

이중경화법을 이용한 열개시제 및 광개시제가 배합된 황칠도료의 경화속도 촉진 및 물성향상 연구 (Improving Curing Rate and Physical Properties of Korean Dendropanax Lacquer with Thermal and Photo Initiator by Dual Curing)

  • 황현득;문제익;박초희;김현중;황백
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권4호
    • /
    • pp.333-340
    • /
    • 2010
  • 한반도 남부 일대에서 자생하는 황칠나무(Dendropanax morbifera Lev.) 수액으로부터 추출한 천연 도료인 황칠도료(Korean Dendropanax lacquer)는 예로부터 귀중한 예술품이나 투구, 화살, 활 등의 전쟁도구를 찬란한 황금색으로 도장하는데 사용되어 왔다. 경화 후 황금색의 투명한 도막을 형성하여 우수한 색상특성을 지니고 있을 뿐만 아니라 내후성, 내수성, 내식성 등이 우수하여, 보호도장으로써도 훌륭한 가치를 지니고 있다. 그러나 이러한 많은 장점에도 불구하고, 현대적인 여러 적용분야에 사용되지 못하고 있는 이유는 황칠도료의 생산량이 적고, 이로 인하여 가격이 매우 고가이고, 장시간의 경화시간이 소요되는 문제도 큰 원인으로 작용하고 있다. 한편 황칠 내에 광중합이 가능한 conjugated diene을 포함한 모노머가 있으며, 이러한 모노머는 일광 조사 조건등에 의하여 짧은 시간에 단단하고 황금색을 띠는 도막을 형성할 수 있음이 보고된 바가 있다. 따라서 본 연구에 서는 전통적인 황칠도료의 경화방법을 개선하고 경화속도를 촉진하기 위하여, 열개시제를 도입하여 열경화를 촉진하는 방법과 열개시제 및 광개시제를 동시에 도입하고 이중경화(dual curing)에 의해서 경화속도를 촉진하고자 하였다. 이러한 경화 속도 및 경화 거동은 적외선분광분석기(FT-IR)을 이용하여 -C=C- 이중결합 특성피크의 변화를 관찰하거나, 진자경도계(pendulum hardness tester)를 이용하여 표면 경도의 변화를 관찰함으로써 평가하였다. 또한 강체진자물성측정기(RPT)에 spot UV curing 장비를 도입하여 이중경화에 의한 경화 속도 진을 평가하였다. 본 연구의 결과 열개시제에 의하여 열경화가 촉진될 수 있을 뿐만 아니라, 이중경화에 의하여 경화속도를 향상시킬 수 있음을 확인하였다. 또한 이러한 황칠도료 경화 속도 촉진 방법을 활용하여 전통적인 역에만 사용되어온 황칠도료를 현대적인 여러 적용분야에도 확대하여 사용할 수 있는 가능성을 제시하였다.

유한요소법을 이용한 나이티놀 와이어 스텐트의 전산모사 실험 데이터 검증 (The Verification of Computer Simulation of Nitinol Wire Stent Using Finite Element Analysis)

  • 김진영;정원균;전동민;신일균;김한기;신동오;김상호;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제20권3호
    • /
    • pp.139-144
    • /
    • 2009
  • 최근 스텐트 시술의 수학적인 분석은 스텐트의 위치와 기계적인 반응을 측정하는 여러 가지 툴이 개발됨에 따라 발전하고 있다. 그러나 기존의 연구의 경우, 전산모사 실험을 통해 여러 요소에 따른 변형 정도 및 응력 분포, 팽창력 등과 같은 성능평가에 대한 연구가 주류를 이루며 전산모사 실험을 통한 응력 분포 및 변형 정도에 대한 소프트웨어의 검증은 거의 없는 실정이다. 따라서 본 연구에서는 만능재료 시험기를 이용한 실험을 통해 얻은 결과와 전산모사 실험 결과의 유의성 검증을 통해 해당 전산 모사용 소프트웨어를 통한 전산모사 실험 결과에 신뢰성을 부여하였다. 또한 이를 토대로 전산모사 실험을 통해 스텐트 피막 유무에 따른 스텐트의 응력분포를 분석하고자 하였다. 본 연구에서는 전산모사 실험 데이터와 실제 인장 시험 데이터를 통한 유의성 검증을 하고자 하였다. 스텐트의 연결 부분에 대해 유한요소 해석법을 적용하여 전산모사 실험을 수행한 결과, 178.93 MPa의 최대응력으로 인장시험 결과인 184.23 MPa와 거의 유사한 값을 가졌으며, 이를 통해 인장시험 결과와 전산모사 결과가 유의성을 가짐을 검증할 수 있었다. 또한 피막 유무에 따른 스텐트의 전산모사 실험을 통해 피막에서는 접촉부, 나이티놀에서는 연결부에서 최대 응력이 발생함을 알 수 있었다. 그리고 피막이 있는 경우에는 피막의 장력으로 인해 연결부분에서 형상을 유지하고 있으나 피막이 없는 경우에는 이격 및 교차부에서 슬립이 발생함을 알 수 있었다. 이러한 결과들을 통해 스텐트 설계 초기에 있어 해당 전산모사용 소프트웨어를 통해 해석을 수행하여 그에 따른 해석 결과를 설계에 반영함으로써 설계 변경을 최소화할 수 있고, 이에 따라 양질의 설계 품질 확보가 가능할 것으로 사료된다.

  • PDF

Deep Neural Network와 Convolutional Neural Network 모델을 이용한 산사태 취약성 매핑 (Landslide Susceptibility Mapping Using Deep Neural Network and Convolutional Neural Network)

  • 공성현;백원경;정형섭
    • 대한원격탐사학회지
    • /
    • 제38권6_2호
    • /
    • pp.1723-1735
    • /
    • 2022
  • 산사태는 가장 널리 퍼진 자연재해 중 하나로 인명 및 재산피해 뿐만 아니라 범 국가적 차원의 피해를 유발할 수 있기 때문에 효과적인 예측 및 예방이 필수적이다. 높은 정확도를 갖는 산사태 취약성도를 제작하려는 연구는 꾸준히 진행되고 있으며 다양한 모델이 산사태 취약성 분석에 적용되어 왔다. 빈도비 모델, logistic regression 모델, ensembles 모델, 인공신경망 등의 모델과 같이 픽셀기반 머신러닝 모델들이 주로 적용되어 왔고 최근 연구에서는 커널기반의 합성곱신경망 기법이 효과적이라는 사실과 함께 입력자료의 공간적 특성이 산사태 취약성 매핑의 정확도에 중요한 영향을 미친다는 사실이 알려졌다. 이러한 이유로 본 연구에서는 픽셀기반 deep neural network (DNN) 모델과 패치기반 convolutional neural network (CNN) 모델을 이용하여 산사태 취약성을 분석하는 것을 목적으로 한다. 연구지역은 산사태 발생 빈도가 높고 피해가 큰 인제, 강릉, 평창을 포함한 강원도 지역으로 설정하였고, 산사태 관련인자로는 경사도, 곡률, 하천강도지수, 지형습윤지수, 지형위치 지수, 임상경급, 임상영급, 암상, 토지이용, 유효토심, 토양모재, 선구조 밀도, 단층 밀도, 정규식생지수, 정규수분지수의 15개 데이터를 이용하였다. 데이터 전처리 과정을 통해 산사태관련인자를 공간데이터베이스로 구축하였으며 DNN, CNN 모델을 이용하여 산사태 취약성도를 작성하였다. 정량적인 지표를 통해 모델과 산사태 취약성도에 대한 검증을 진행하였으며 검증결과 패치기반의 CNN 모델에서 픽셀기반의 DNN 모델에 비해 3.4% 향상된 성능을 보였다. 본 연구의 결과는 산사태를 예측하는데 사용될 수 있고 토지 이용 정책 및 산사태 관리에 관한 정책 수립에 있어 기초자료 역할을 할 수 있을 것으로 기대된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF