• Title/Summary/Keyword: Machine breakdown

Search Result 83, Processing Time 0.029 seconds

Lot Sizing and Quality Inspection Schedules with Machine Breakdown (기계 고장을 고려한 생산 및 품질검증 정책)

  • 이창환
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.21 no.3
    • /
    • pp.143-157
    • /
    • 1996
  • This paper addresses the effects of an imperfect production process on the optimal production quantity and quality inspection policies. The system is assumed to deteriorate during the production process. The result are either the production of a number of defective items or the breakdown of the production meachine. A simple rule has been suggested to determine whether multiple quality in spection is workth or not. Furthermore, when multiple inspection policy is adopted, the optimal in spection schedule is shown to be equally spaced throughout the production cycle. Exact solution and approximation of the optimal production quantity and approximation of the optimal number of inspection are provided. Finally , to better understand the model of this paper, comparisons between this model and classical EMQ model are provided.

  • PDF

Temperature dependance of Dielectric strength in Nano-composites (Nano-composites 절연파괴강도의 온도의존성)

  • Lee, Kang-Won;Lee, Hyuk-Jin;Kim, Jong-Hwan;Shin, Jong-Yeol;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.256-257
    • /
    • 2008
  • Recently, with the increase of demand of electricity, electric cable or electric transfer machine are rapidly developed and meet the demand with the extra high voltage and massive capacity, the dangers of electrical accident of insulator are increasing by the electric stress, insulation degradation and insulation breakdown in insulator. In this paper, it is investigated that the temperature dependance of dielectric strength in nano-composites. We obtained that breakdown voltage of 0.4 [wt%] specimens is higher than the other $SiO_2$ content.

  • PDF

Reliability Analysis of Machinery system for Failure Mode and Effect Analysis (FMEA를 이용한 기계류 시스템의 신뢰도 분석)

  • 진도훈;우태수;이치우
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.30-35
    • /
    • 2002
  • This paper dealt with FMEA, which is a method of the analysis to secure safety and confidence coming up to customers'expectation in consideration of the environment of the corporation, the industrial environment, and the functional improvement. And by using FMEA, We showed the example analyzed the confidence of the Air Supply System. It was proved by the result of the analysis that the rate of the breakdown which is usually regarded as the first important point to reform can't satisfy the selecting basis to improve. Also the result said that it is not right to depend on only the rate of the failure in making the list of the reform. Through the analysis of the breakdown, FMEA can present the important factors of the reform to improve the confidence of the system. In this study would show the important factors of the improvement in order to product the goods guaranteed confidence through the method of FMEA.

  • PDF

A Study on Thermal, Mechanical and Electrical Properties as Silane Treated Epoxy/MICA Composites (실란처리된 Epoxy/MICA 콤포지트의 열적, 기계적 전기적 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.213-218
    • /
    • 2013
  • In this study, epoxy/mica composite was prepared by mixing with mechanical stirrer together with homogenizer, and the effect of amino-type silane coupling agent was also studied. To reduce the viscosity without any decrement of other properties, 1,4-Butanediol diglycidyl ether (1,4-BDGE) as an aliphatic epoxy reactive diluent was introduced to the epoxy/mica composite in order to use as vanish for high voltage motor and generator stator winding. It was confirmed by scanning electron microscopy (SEM) observation that interfacial characteristics between organic epoxy and inorganic mica was modified by coupling agent treatment so that glass transition temperature increased, and tensile strength and electrical breakdown strength increased. The properties were estimated by Weibull statistical analysis and the ac electrical breakdown strength was 20.2% modified by treating silane coupling agent.

The Development of Insulating Jackets for protection of Live-line workers in KEPCO (한국전력에서 활선작업시 착용하는 절연복 개발)

  • Yoo, Ho-Keun;Kim, Woo-Sung;Lee, Jae-Young;Cho, Kye-Cheol;An, Chul-Kyung;Choi, Myeong-Ho;Kim, Sang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.388-389
    • /
    • 2007
  • Objective of the study is development of 23kV insulating jackets for protection of workers from electrical shock. The breakdown voltage of Ethylene-VinylAcetate copolymers(EVA) films in insulating oil were measured. Insulating jackets were made by the high frequency welding machine, and withstanding voltage test of these were measured. For breakdown voltage at AC 30kV, the number of EVA film with $105{\pm}5{\mu}m$ thickness was 4$\sim$5pieces. When AC 30kV during 3 minutes supplied on the insulating jackets, those were keep on the good quality.

  • PDF

Electrical and Mechanical Properties of Epoxy/Micro-sized Alumina Composite and the Effect of Nano-sized Alumina on Those Properties

  • Park, Jae-Jun;Shin, Seong-Sik;Yoon, Chan-Young;Lee, Jae-Young;Park, Joo-Eon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.260-263
    • /
    • 2015
  • Epoxy/micro-sized alumina composite was prepared and the effects of alumina content on the electrical and mechanical properties were investigated in order to develop an insulation material for gas insulated switchgear (GIS). Nano-sized alumina (average particle size: 30 μm) was also incorporated into the epoxy/micro-sized alumina composite. An electrical insulation breakdown strength test was carried out in sphere-sphere electrodes and the data were estimated by Weibull statistical analysis. Tensile strength was measured at a crosshead speed of 10 mm/min using a universal testing machine. Alumina content was varied from 0 wt% to 70 wt%.). As micro-sized alumina content increased, insulation breakdown strength increased until 40 wt% alumina content and decreased after that content. The tensile strength of a neat epoxy system was 82.2 MPa and that value for 60 wt% alumina content was 91.8 MPa, which was 111.7% higher than inthe neat epoxy system. The insulation breakdown strength of micro-sized alumina (60 wt%)/nano-sized alumina (1 phr) glycerol diglycidyl ether (GDE) (1 phr) composite was 54.2 MPa, which was 116% higher than the strength of the system without nano-sized alumina.

Analysis of Voltage Stress in Stator Windings of IGBT PWM Inverter-Fed Induction Motor Systems

  • Hwang Don-Ha;Lee Ki-Chang;Jeon Jeong-Woo;Kim Yong-Joo;Lee In-Woo;Kim Dong-Hee
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.43-49
    • /
    • 2005
  • The high rate of voltage rise (dv/dt) in motor terminals caused by high-frequency switching and impedance mismatches between inverter and motor are known as the primary causes of irregular voltage distributions and insulation breakdowns on stator windings in IGBT PWM inverter-driven induction motors. In this paper, voltage distributions in the stator windings of an induction motor driven by an IGBT PWM inverter are studied. To analyze the irregular voltages of stator windings, high frequency parameters are derived from the finite element (FE) analysis of stator slots. An equivalent circuit composed of distributed capacitances, inductance, and resistance is derived from these parameters. This equivalent circuit is then used for simulation in order to predict the voltage distributions among the turns and coils. The effects of various rising times in motor terminal voltages and cable lengths on the stator voltage distribution are also presented. For a comparison with simulations, an induction motor with taps in the stator turns was made and driven by a variable-rising time switching surge generator. The test results are shown.

A Study on the Introduction of Signal Kanban System (Signal 간판시스템의 도입에 관한 연구)

  • 김태호;송수정;강경식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.19 no.40
    • /
    • pp.301-309
    • /
    • 1996
  • The operation of the traditional pull Kanban system in Domestic is limited because the production circumstance of the Domestic industries have the characteristics of dynamic production circumstance such as high variability of demand, frequent machine breakdown or defect, high absence or separation rates of the employees. The purpose of this study is to find the optimal Kanban system for the production circumstance of the Domestic industry. By using the computer simulation, selected models are tested for the susceptibility to the production factors and with the analysis of the data from the simulations.

  • PDF

기계고장을 고려한 생산및 품질검증 정책

  • 이창환
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.298-301
    • /
    • 1996
  • This paper addresses the effects of an imperfect production process on the optimal production quantity and quality inspection policies. The system is assumed to deteriorate during the production process. The results are either defective products or machine breakdown whether multiple quality inspection is worth or not. Furthermore, when multiple inspection policy is adopted, the optimal inspection schedule is shown to be equally spaced throughout the production cycle. Exact solution and approximation of the optimal production quantity and approximation of the optimal number of inspection are provided. Finally, to better understand the model of this paper, comparisons between this model and classical EMQ model are provided.

  • PDF

The Development of wide frequency analyzing system by partial electric discharge electromagnetic-wave Receiver (부분방전 전자파 측정용 광대역 주파수 분석 시스템 개발)

  • Park, Doo-Yong;Shin, Young-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.547-549
    • /
    • 2004
  • This system is monitors the degree of aging happened at the electric machine. It detects electromagnetic wave generated from the insulator when the voltage is applied to the machine. By analyzing the internal and external factors make the electric, mechanic, or thermal characteristics of the electric machinery deteriorate the electric insulation and eventually cause the partial electric discharge. The continuous partial electric charge accelerates the insulation aging and the insulation breakdown happens at last. This system consists of the relays connected with 10 sensors (40 total) detecting the partial electric discharge ans the temperature, the server, ans the program analyzing and storing the data.

  • PDF