• Title/Summary/Keyword: Machine

Search Result 24,499, Processing Time 0.054 seconds

Fully Automated Liquid Culture System Compared with Lowenstein-Jensen Solid Medium for Rapid Recovery of Mycobacteria in Sputums (완전 자동화된 액체배양법과 기존의 고체배양법을 이용한 객담 내 mycobacterium의 신속검출에 대한 비교)

  • Park, Seung-Kyu;Kim, Seung-Chul;Kim, Deuk-Mi;Lee, Chang-Woon;Kim, Young;Cho, Sang-Nae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.635-643
    • /
    • 2002
  • Background : The Aim of this study was to compare the recovery of mycobacteria from sputum samples of pulmonary tuberculosis patients using the MB/BacT rapid culture system(Organon Teknika, USA) with that obtained using Lowenstein-Jensen solid medium. Methods : The two culture systems were compared using sputum samples of 99 pulmonary tuberculosis patients. Culture media were incubated at $35-37^{\circ}C$ for six weeks in the MB/BacT system and for 12 weeks in Lowenstein-Jensen solid medium. Solid media were examined macroscopically once a week, and the MB/BacT system positive vials were unloaded from the machine as soon as possible after positive signal from the connected computer was detected Confirmation of growth for mycobacteria was done by Ziehl-Neelson stained smears. Isolates were identified to differentiate Mycobacterium tuberculosis from mycobacterium other than tuberculosis(MOTT) by phenotypic and molecular methods. Results : Of the sputum samples of the 99 patients, 58 samples were smear positive and 41 in negative smear. Mycobacteria were recovered from 67(67.7%) samples by using both culture systems. The yield with MB/BacT was higher than that with Lowenstein-Jensen [67(67.7%) vs. 52(52.5%), p<0.001]. Moreover, 15(15.2%) samples were positive only in the MB/BacT, whereas none of samples was positive only in Lowenstein-Jensen. In smear-positive and smear-negative samples, the recovery rate with MB/BacT was also higher than that with Lowenstein-Jensen [sputum-positive; 56/58(96.6%) vs. 46/58(79.3%), p=0.005, sputum-negative; 6/41(14.6%) vs. 5/41(12.2%), p<0.001]. The mean times to detection of Mycobacteria were 13.3 and 27.2 days with MB/BacT and Lowenstein-Jensen respectively(p<0.001). Conclusion : This results indicate that the the MB/BacT is more efficient and faster than Lowenstein-Jensen for the recovery of mycobacteria.

Type and Characters of Agricultural Injury Subjective Burden (농작업 손상에 대한 주관적 부담의 종류 및 특성)

  • Youn, Kanwoo;Im, Sanghyuk;Park, Jinwoo;Lee, Kyungsuk;Chae, Hyeseon
    • Journal of agricultural medicine and community health
    • /
    • v.41 no.1
    • /
    • pp.1-12
    • /
    • 2016
  • Objectives: In establishing policies for agricultural safety, evaluating injury burdens as well as investigating the rates and characteristics of work injury is important. This study investigated the types and characteristics of agricultural injury subjective burdens. Methods: By analyzing the injured farmers identified in the 2013 Korean Farmers' Occupational Injury Survey, the burdens caused by injuries were categorized using one direct cost item (medical costs) and five indirect cost items (including productivity decreases and wage increases). Statistical differences among the burden items were analyzed using logistic regression analysis according to the characteristics of the farmers and their farm injuries. Results: Among the subjective burdens indicated by the 457 injured farmers, disruption to work was most common. The major influences on each subjective burden item are as follows: for the item of disruption to work, age, time of injury occurrence, treatment period, and farming machine use were influential; for an increased family member's burden of farm works, the number of family members and treatment period were influential. Regarding cost burden of treatment, the results varied according to whether or not the patient was hospitalized and annual income. Conclusion: Subjective burdens induced by indirect costs rather than those induced by direct costs were found to be higher in ratio. In regard to each burden item, the results varied according to the characteristics of the farmers and their farm injuries. To support injured farmer, setting goals to reduce indirect cost burdens and preparing concrete methods is necessary.

Usefulness of Data Mining in Criminal Investigation (데이터 마이닝의 범죄수사 적용 가능성)

  • Kim, Joon-Woo;Sohn, Joong-Kweon;Lee, Sang-Han
    • Journal of forensic and investigative science
    • /
    • v.1 no.2
    • /
    • pp.5-19
    • /
    • 2006
  • Data mining is an information extraction activity to discover hidden facts contained in databases. Using a combination of machine learning, statistical analysis, modeling techniques and database technology, data mining finds patterns and subtle relationships in data and infers rules that allow the prediction of future results. Typical applications include market segmentation, customer profiling, fraud detection, evaluation of retail promotions, and credit risk analysis. Law enforcement agencies deal with mass data to investigate the crime and its amount is increasing due to the development of processing the data by using computer. Now new challenge to discover knowledge in that data is confronted to us. It can be applied in criminal investigation to find offenders by analysis of complex and relational data structures and free texts using their criminal records or statement texts. This study was aimed to evaluate possibile application of data mining and its limitation in practical criminal investigation. Clustering of the criminal cases will be possible in habitual crimes such as fraud and burglary when using data mining to identify the crime pattern. Neural network modelling, one of tools in data mining, can be applied to differentiating suspect's photograph or handwriting with that of convict or criminal profiling. A case study of in practical insurance fraud showed that data mining was useful in organized crimes such as gang, terrorism and money laundering. But the products of data mining in criminal investigation should be cautious for evaluating because data mining just offer a clue instead of conclusion. The legal regulation is needed to control the abuse of law enforcement agencies and to protect personal privacy or human rights.

  • PDF

Safety education needs among the dental technology-major college students to prevent injuries in their laboratory classes (치기공과 학생들의 실습 중 안전에 대한 안전교육 요구도 특성)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.177-198
    • /
    • 2006
  • This study purposed to offer basic data for safety education of the dental laboratory technology after the investigation of how much the students in the dept. of dental laboratory technology are aware of the danger of each instrument, equipment or laboratory procedure that they use during laboratory and how much they demand safety education for this. The objects for this study were 423 students who were in the dept. of dental laboratory technology. In this regard, four colleges which have the dept. of dental laboratory technology were randomly selected to do a questionnaire survey. SPSS 12.0 was used to analyze the collected data. The results were as follows: As for satisfaction with their major, the respondents answered Satisfied (59.1%), Average (35.5%) and Dissatisfied (5.4%). In terms of the production process of a partial denture, they considered casting, polishing the casting body, polishing denture and burn out were most dangerous in order. As for the production process of a full denture, what they regarded as the most dangerous in order was polishing denture, deflasking and wax wash. Regarding the laboratory procedures of porcelain material, casting, trimming casting body, polishing porcelain material and burn out were the most dangerous procedures that they perceived. With regard to materials for use, alcohol, polishing, metal and wire were the most dangerous ones they thought. As for the handling characteristics of each material, small towns showed a higher demand for safety of the handling characteristics of alcohol. In terms of school year and sex, juniors and girls had higher scores in the demand for safety of the handling characteristics of acid. Regarding the handling characteristics of each equipment and instrument, all of small towns, juniors and girls showed the highest demand for safety of the handling characteristics of alcohol lamps. With regard to scores in the demand for safety of other characteristics, all of small towns, juniors and girls had the highest demand for safety of emergency treatment. Concerning the demand for safety education by the completion of safety education, in terms of each material, highest was the demand for safety of acid from the group which completed safety education. In regard to equipments and instruments, when it came to the demand for safety of the handling characteristics of casting machine, the educated group's demand for safety of acid was higher. Regarding other characteristics, the group which was not educated gained higher scores in the demand for safety of emergency treatment. 11. In all areas(materials, machines and others), small towns, girls and juniors showed higher scores in the demand for safety. Based on the above results, it was found that when students conduct the laboratory of dental technology, they would think that many materials, instruments or equipments for use are very dangerous. However, safety education was not fully given to them. Regarding the scores in the damned for safety education, the highest was 4.16 and the lowest was 3.43, which suggests that the scores were generally very high. In this regard, it is necessary to continue delivering a systematic safety education of materials, equipments or instruments used during the laboratory of dental technology. Therefore, through the analysis of each material, instruments or facility used in every laboratory and each process, safety accident types and accident risk factors should be investigated to develop educational materials for this. Moreover, it is required to open safety education as a single course of study or insert safety contents of all materials and machines into the class of dental laboratory instrument or dental materials for the purpose of a systematic and thorough safety education to prevent a safety accident during laboratory.

  • PDF

Effects of laser-irradiated dentin on shear bond strength of composite resin (레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향)

  • Kim, Sung-Sook;Park, Jong-Il;Lee, Jae-In;Kim, Gye-Sun;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.520-527
    • /
    • 2008
  • Purpose: This study was conducted to evaluate the shear bond strength of composite resin to dentin when etched with laser instead of phosphoric acid. Material and methods: Recently extracted forty molars, completely free of dental caries, were embedded into acrylic resin. After exposing dentin with diamond saw, teeth surface were polished with a series of SiC paper. The teeth were divided into four groups composed of 10 specimens each; 1) no surface treated group as a control 2) acid-etched with 35%-phosphoric acid 3) Er:YAG laser treated 4) Er,Cr:YSGG laser treated. A dentin bonding agent (Adapter Single Bond2, 3M/ESPE) was applied to the specimens and then transparent plastic tubes (3 mm of height and diameter) were placed on each dentin. The composite resin was inserted into the tubes and cured. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours and the shear bond strength was measured using a universal testing machine (Z020, Zwick, Germany). The data of tensile bond strength were statistically analyzed by one-way ANOVA and Duncan's test at ${\alpha}$= 0.05. Results: The bond strengths of Er:YAG laser-treated group was $3.98{\pm}0.88$ MPa and Er,Cr:YSGG laser-treated group showed $3.70{\pm}1.55$ MPa. There were no significant differences between two laser groups. The control group showed the lowest bond strength, $1.52{\pm}0.42$ MPa and the highest shear bond strength was presented in acid-etched group, $7.10{\pm}1.86$ MPa (P < .05). Conclusion: Laser-etched group exhibited significantly higer bond strength than that of control group, while still weaker than that of the phosphoric acid-etched group.

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

The effect of Silano-pen on the shear bond strength of resin to feldspathic porcelain and zirconia (실라노 펜의 적용이 장석계 도재 및 지르코니아와 레진의 전단결합강도에 미치는 영향)

  • Shin, Myoung-Sik;Lee, Jeong-Yol;Kim, Min-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: The purpose of this study is to evaluate the effect of applying Silano-pen to feldspathic porcelain and zirconia on shear bond strength with composite resin. Materials and methods: Feldspathic porcelain and zirconia specimens were produced into 30 per each 2 mm thick and 12 mm in diameter and their surface was made smooth and even and then embedded in acrylic resin. The specimens were divided into each Group F (Feldspathic porcelain) and Group Z (Zirconia), (1) Hydrofluoric acid etching and silane (F1 & Z1), (2) Silano-pen and silane (F2 & Z2), (3) Hydrofluoric acid etching and Silano-pen, silane (F3 & Z3). After surface conditioning, substrate surfaces of the specimen were examined by SEM. Composite resin cylinders (2 mm high, 3 mm in diameter)were bonded to specimen and shear bond strength between ceramic and composite resin was measured by using universal testing machine. The measured values were statistically analyzed by using two way ANOVA and Tukey's multiple comparison test (${\alpha}=.05$). Results: In the scanning electron micrograph of the treated ceramic surface, Group F2 and F3 appeared the high roughness and Group Z3 appeared the highest density of silica particle. In Feldspathic porcelain, the result of measuring shear bond strength showed that Group F3 was measured to be highest and Group F1 was measured to be lowest but there was no statistical significance among Groups. In zirconia, Group Z3 was measured to be highest and Group Z1 was measured to be lowest and there was statistical significance among Groups (P<.05). Conclusion: In zirconia, applying hydrofluoric acid etching and then Silano-pen and silane is effective for composite resin adhesion.

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.

The effect of heat to remove cement on implant titanium abutment and screw (시멘트 제거를 위해 가한 열이 임플란트 티타늄 지대주와 나사에 미치는 영향)

  • Yi, Hyo-Gyoung;Gil, Ki-Sung;Lee, Jung-Jin;Ahn, Seung-Geun;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.179-187
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effect of heat applied to disintegrate cement on the removal torque value and fracture strength of titanium abutment and abutment screw. Materials and methods: Implants, titanium abutments and abutment screws were prepared for each 20 piece. Implant abutments and screws were classified as the control group in which no heat was applied and the experimental group was heated in a vacuum furnace to $450^{\circ}C$ for 8 minutes and cooled in air. The abutments and screws were connected to the implants with 30 Ncm tightening torque at interval 10 minutes and the removal torque value was measured 15 minutes later. And the fracture strength of abutment screw was measured using universal testing machine. Results: The mean removal torque value was $27.84{\pm}1.07Ncm$ in the control group and $26.55{\pm}1.56Ncm$ in the experimental group and showed statistically significant difference (P < .05). The mean fracture strength was $731.47{\pm}39.46N$ in the control group and $768.58{\pm}46.73N$ in the experimental group and showed statistically no significant difference (P > .05). Conclusion: The heat applied for cement disintegration significantly reduced the removal torque value of the abutment screw and did not significantly affect fracture strength of the abutment screw. Therefore, in the case of applying heat to disintegrate cement it is necessary to separate the abutment screw or pay attention to the reuse of the heated screw. However further studies are needed to evaluate the clinical reuse of the heated screw.

ELASTIC CONSTANTS, SHEAR BOND STRENGTH OF TUNNEL RESTORATIVE MATERIALS AND MARGINAL RIDGE STRENGTH OF RESTORED TEETH (터널형 2급와동 충전재의 탄성계수와 전단결합강도 및 수복치의 변연융선 파절강도에 관한 연구)

  • Lee, Ka-Yean;Park, Yeong-Joon;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.3
    • /
    • pp.746-763
    • /
    • 1996
  • An alternative design to conventional class II cavity preparation for proximal carious lesions is the tunnel preparation. It preserves the marginal ridge intact, thus making it possible to maintain the natural contact relationship with the adjacent tooth and minimize tooth reduction. This in vitro study was purposed to evaluate the effect of the materials' elastic constants and shear-bond strength on the marginal ridge fracture resistance of teeth restored by the tunnel technique, and to find the materials of choice for tunnel restorations. $Resinomer^{(R)}$, $Ketac-silver^{(R)}$, $Miracle-Mix^{(R)}$, and Tytin were used as restorative material. The elastic constants of each restorative material were evaluated by ultrasonic pulse measurement. Young's modulus and bulk modulus of the restorative materials were evaluated in three specimens for each material type. The shear-bond strength of the restorative materials to the dentin surface was measured after thermocycling 400 times between 6 and $60^{\circ}C$, using ten specimens for each material type. For measuring marginal ridge strength, 60 sound extracted molar teeth were distributed into six groups by size. Sound molar teeth were used as a Control group and unfilled prepared teeth were grouped as Unrestored. Another four groups were named Resinomer group, Ketac-Silver group, Miracle Mix group, and Tytin group by type of restorative material. Tunnel cavity preparation was done with ' 1/2, 2, and 4 round burs in sequence. Initial access to proximal surface was made through an occlusal access preparation started at least 2mm from the marginal ridge, and the proximal opening was formed about 2.5mm below the marginal ridge. After restoration and thermocycling, marginal ridge strength was measured using a universal testing machine. The results were as follows: 1. The Young's modulus of $Tytin^{(R)}$ was 63.95 GPa, followed by $Ketac-Silver^{(R)}$ 27.60 GPa, $Miracle-mix^{(R)}$ 18.48 GPa, and $Resinomer^{(R)}$ 10.74 GPa showing significant differences between the groups(P<0.05). The bulk modulus of the materials showed the same order as Young's modulus. The value of $Tytin^{(R)}$ showed 59.57 GPa indicating that it will deform less than other materials under the same stress. It was followed by $Ketac-Silver^{(R)}$ 23.57 GPa, Miracle $Mix^{(R)}$ 12.50 GPa, and $Resinomer^{(R)}$ 11.60 GPa. 2. The Resinomer group had a shear-bond strength of 7.41 MPa which was significantly higher than those of the Ketac-Silver group (1.80 MPa) and the Miracle Mix group (2.84 MPa) (P<0.01). All the specimens of Tytin group detatched from the dentin surface during thermocycling. 3. The mean marginal ridge strength of the Unrestored group(46.14 kgf) was significantly lower than that of the Control group (84.24 kgf) (P<0.01). The marginal ridge strength of teeth restored by the tunnel technique was, in order, Ketac-Silver group 74.06 kgf, Miracle Mix group 73.36 kgf, Resinomer group 63.47 kgf, and Tytin group 58.76 kgf. The Ketac-Silver, Miracle Mix, and Resinomer groups showed no significant difference with the Control group (P>0.05), but the Tytin group showed significantly lower strength compared to the Control group(P<0.05). The results showed that the marginal ridge strength of the teeth restored by the tunnel technique was not significantly lower than that of sound teeth. They also demonstrated that the bonding strength of the restorative material to the tooth surface should be high and the modulus of elasticity should not be lower than that of the tooth in order to restore the marginal ridge strength to its natural condition.

  • PDF