Browse > Article

The study of shear bond strength of a self-adhesive resin luting cement to dentin  

In, Hee-Sun (Department of Dentistry, Graduate School, Wonkwang University)
Park, Jong-Il (Department of Dentistry, Graduate School, Wonkwang University)
Choi, Jong-In (Department of Dentistry, Graduate School, Wonkwang University)
Cho, Hye-Won (Department of Dentistry, Graduate School, Wonkwang University)
Dong, Jin-Keun (Department of Dentistry, Graduate School, Wonkwang University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.46, no.5, 2008 , pp. 535-543 More about this Journal
Abstract
Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.
Keywords
Shear bond strength; Resin cement; Self-adhesive resin cement; Phosphoric acid;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Walter R, Miguez PA, Pereira PN. Microtensile bond strength of luting materialsto coronal and root dentin. J Esthet Restor Dent 2005;17:165-71   DOI   ScienceOn
2 Pashley DH, Carvalho RM. Dentin permeability and dentin adhesion. J Dent 1997;25:355-72   DOI   ScienceOn
3 DW Kim, SJ Park, GK Choi. Compatibility of self-etching dentin adhesives with resin luting cements. J Kor Acad Cons Dent 2005;30:493-504   과학기술학회마을   DOI
4 Vargas MA, Cobb DS, Denehy GE. Interfacial micromorphology and shear bond strength of single-bottle primer/ adhesives. Dent Mater 1997;13:316-24   DOI   ScienceOn
5 Tjan AH, Dunn JR, Grant BE. Marginal leakage of cast gold crowns luted with an adhesive resin cement. J Prosthet Dent 1992;67:11-5   DOI   ScienceOn
6 Anusavice KJ. Phillips science of dental materials.11th ed. Saunders, Missouri, USA, 2003;443-94
7 Piwowarczyk A, Laucer HC, Sorensen JA. In vitro shear bond strength of cementing agents to fixed prosthodontic restorative materials. J Prosthet Dent 2004;92:265-73   DOI   ScienceOn
8 de Souza Costa CA, Hebling J, Randall RC.Human pulp response to resin cements used to bond inlay restorations. Dent Mater J 2006;22:954-62   DOI   ScienceOn
9 Platt JA. Resin cements into the 21st century. CompCont Edue Dent 1999;20:1173-88
10 Benelli EM, Serra MC, Rodrigues AL Jr, Cury JA. In situ anticariogenic potential of glass ionomer cement. Caries Res 1993;27:280-4   DOI   ScienceOn
11 Escribano N, de la Macorra JC. Microtensile bond strength of self -adhesive luting cements to ceramic. J Adhes Dent 2006;8:337-41
12 Groten M, Probster L. The influence of different cementation modes on the fracture resistance of feldspathic ceramic crowns. Int J Prosthodont 1997;10:169-77   PUBMED
13 Timmons S, Cobb D, Stanford C, Dawson D, Denehy J, Vargas M. Post-operative sensitivity of bonded ceramic posterior inlays and onlays. J Dent Res 2004;83 (Spec Iss A):1538
14 White SN, Sorensen JA, Kang SK, Caputo AA. Microleakage of new crown and fixed Partial denture luting agents. J Prosthet Dent 1992;67:156-61   DOI   ScienceOn
15 Abo-Hamar SE, Hiller KA, Jung H, Federlin M, Friedl KH, Schmalz G. Bond strength of a new universal self-adhesive resin luting cement to dentin and enamel. Clin Oral Investig 2005;9:161-7   DOI
16 Yang B, Ludwig K, Adelung R, Kern M. Micro- tensile bond strength of three luting resins to human regional dentin. Dent Mater 2006;22:45-56   DOI   ScienceOn
17 Probster L. Survival rate of In-Ceram restoration. Int J Prosthodont 1993;6:259-63   PUBMED
18 Stangel I, Nathanson D, Hsu CS. Shear strength of the composite bond to etched porcelain. J Dent Res 1987;66:1460-5   DOI   PUBMED   ScienceOn
19 Kececi AD, Ureyen Kaya B, Adanir N. Micro push-out bond strengths of four fiber-reinforced composite post systems and 2 luting materials. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;105:121-8   DOI   ScienceOn
20 3M ESPE. Wissenschaftliches Produktdossier RelyX Unicem. 3M ESPE AG, 82229 Seefeld, Germany
21 Roulet JF, Soderholm KJ, Longmate J. Effects of treatment and storage conditions on ceramic/composite bond strength. J Dent Res 1995;74:381-7   DOI   ScienceOn
22 Dixon DL, Breeding LC, Hughie ML, Brown JS. Comparison of shear bond strengths of two resin luting systems for a base and a high noble metal alloy bonded to enamel. J Prosthet Dent 1994;72:457-61   DOI   ScienceOn
23 Gerth HU, Dammaschke T, Zuchner H, Schafer E. Chemical analysis and bonding reaction of RelyX Unicem and Bifix composites - A comparative study. Dent Mater J 2006;22:934-41   DOI   ScienceOn
24 Cobb D, Timmons S, Stanford C, Dawson D, Denehy G, Vargas M. Clinical outcomes of ceramic inlays/ onlays luted with two bonding systems. J Dent Res 2004;83 (Spec Iss A):1539
25 Kramer N, Lohbauer U, Frankenberger R. Adhesive luting of indirect restorations. Am J Dent 2000;13:60-76   PUBMED
26 Eden GT, Kacicz JM. Dicor crownstrength improvement due to bonding (abstract). J Dent Res 1987;66:207
27 Behr M, Rosentritt M, Regnet T, Lang R, Handle G. Marginal adaptation in dentin of a self-adhesive universal resin cement compared with well-tried systems. Dent Mater J 2004;20:191-7   DOI   ScienceOn
28 erdigao J, Lambrechts P, van Meerbeek B, Tome AR, Vanherle G, Lopes AB. Morphological field emission- SEM study of the effect of six phosphoric acid etching agents on human dentin. Dent Mater J 1996;12:262-71   DOI   ScienceOn
29 Technical data sheet : Espertise RelyX Unicem (2002) 3M ESPE, seefeld Germany
30 De Munck J, Vargas M, Van Landuyt K, Hikita K, Lambrechts P, Van Meerbeek B. Bonding of an auto-adhesive luting material to enamel and dentin. Dent Mater 2004;20:963-71   DOI   ScienceOn
31 Hikita K, Van Meerbeek B, De Munck J, Ikeda T, Van Landuyt K, Maida T, Lambrechts P, Peumans M. Bonding effectiveness of adhesive luting agents to enamel and dentin. Dent Mater 2007;23:71-80   DOI   ScienceOn
32 Hasegawa EA, Boyer DB, Chan DC. Hardening of dualcared cements under composite resin inlays. J Prosthet Dent 1991;66:187-92   DOI   ScienceOn