• 제목/요약/키워드: MS Office

검색결과 126건 처리시간 0.026초

Digital Forensics of Microsoft Office 2007-2013 Documents to Prevent Covert Communication

  • Fu, Zhangjie;Sun, Xingming;Xi, Jie
    • Journal of Communications and Networks
    • /
    • 제17권5호
    • /
    • pp.525-533
    • /
    • 2015
  • MS Office suit software is the most widely used electronic documents by a large number of users in the world, which has absolute predominance in office software market. MS Office 2007-2013 documents, which use new office open extensible markup language (OOXML) format, could be illegally used as cover mediums to transmit secret information by offenders, because they do not easily arouse others suspicion. This paper proposes nine forensic methods and an integrated forensic tool for OOXML format documents on the basis of researching the potential information hiding methods. The proposed forensic methods and tool cover three categories; document structure, document content, and document format. The aim is to prevent covert communication and provide security detection technology for electronic documents downloaded by users. The proposed methods can prevent the damage of secret information embedded by offenders. Extensive experiments based on real data set demonstrate the effectiveness of the proposed methods.

Development and validation of a qualitative GC-MS method for methamphetamine and amphetamine in human urine using aqueous-phase ethyl chloroformate derivatization

  • Kim, Jiwoo;Sim, Yeong Eun;Kim, Jin Young
    • 분석과학
    • /
    • 제33권1호
    • /
    • pp.23-32
    • /
    • 2020
  • Methamphetamine (MA) is the most common and available drug of abuse in Korea and its primary metabolite is amphetamine (AP). Detection of AP derivatives, such as MA, AP, phentermine (PT), MDA, MDMA, and MDEA by the use of immunoassay screening is not reliable and accurate due to cross-reactivity and insufficient specificity/sensitivity. Therefore, the analytical process accepted by most urine drug-testing programs employs the two-step method with an initial screening test followed by a more specific confirmatory test if the specimen screens positive. In this study, a gas chromatography-mass spectrometric (GC-MS) method was developed and validated for confirmation of MA and AP in human urine. Urine sample (500 µL) was added with N-isopropylbenzylamine as internal standard and ethyl chloroformate as a derivatization reagent, and then extracted with 200 µL of ethyl acetate. Extracted samples were analysed with GC-MS in the SIM/ Scan mode, which were screened by Cobas c311 analyzer (Roche/Hitachi) to evaluate the efficiency as well as the compatibility of the GC-MS method. Qualitative method validation requirements for selectivity, limit of detection (LOD), precision, accuracy, and specificity/sensitivity were examined. These parameters were estimated on the basis of the most intense and characteristic ions in mass spectra of target compounds. Precision and accuracy were less than 5.2 % (RSD) and ±14.0 % (bias), respectively. The LODs were 3 ng/mL for MA and 1.5 ng/mL for AP. At the screening immunoassay had a sensitivity of 100% and a specificity of 95.1 % versus GC-MS for confirmatory testing. The applicability of the method was tested by the analysis of spiked urine and abusers' urine samples.

Determination of methamphetamine and amphetamine enantiomers in human urine by chiral stationary phase liquid chromatography-tandem mass spectrometry

  • Sim, Yeong Eun;Ko, Beom Jun;Kim, Jin Young
    • 분석과학
    • /
    • 제32권5호
    • /
    • pp.163-172
    • /
    • 2019
  • Methamphetamine (MA) is currently the most abused illicit drug in Korea and its major metabolite is amphetamine (AP). As MA exist as two enantiomers with the different pharmacological properties, it is necessary to determine their respective amounts in a sample. Thus a chiral stationary phase liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for identification and quantification of d-MA, l-MA, d-AP, and l-AP in human urine. Urine sample ($200{\mu}L$) was diluted with pure water and purified using solid-phase extraction (SPE) cartridge. A $5-{\mu}L$ aliquot of SPE treated sample solution was injected into LC-MS/MS system. Chiral separation was carried out on the Astec Chirobiotic V2 column with an isocratic elution for each enantiomer. Identification and quantification of enantiomeric MA and AP was performed using multiple reaction monitoring (MRM) detection mode. Linear regression with a $1/x^2$ as the weighting factor was applied to generate a calibration curve. The linear ranges were 25-1000 ng/mL for all compounds. The intra- and inter-day precisions were within 3.6 %, while the intra- and inter-day accuracies ranged from -5.4 % to 11.8 %. The limits of detection were 2.5 ng/mL (d-MA), 3.5 ng/mL (l-MA), 7.5 ng/mL (d-AP), and 7.5 ng/mL (l-AP). Method validation parameters such as selectivity, matrix effect, and stability were evaluated and met acceptance criteria. The applicability of the method was tested by the analysis of genuine forensic urine samples from drug abusers. d-MA is the most common compound found in urine and mainly used by abusers.

Development and validation of a qualitative GC-MS method for THCCOOH in urine using injection-port derivatization

  • Sim, Yeong Eun;Kim, Ji Woo;Kim, Jin Young
    • 분석과학
    • /
    • 제34권2호
    • /
    • pp.68-77
    • /
    • 2021
  • Cannabis is one of the most abused drugs in Korea. The main psychoactive component in cannabis, Δ9-tetrahydrocannabinol, is metabolized to 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) and THCCOOH-glucuronide (THCCOOH-glu) in the human liver, whereby the amount of THCCOOH-glu found in urine is twice as high as that of THCCOOH. The analytical process adapted by the majority of urine drug-testing programs involves a two-step method consisting of an initial immunoassay-based screening test followed by a confirmatory test if the screening test result is positive. In this study, a qualitative gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the detection of THCCOOH in human urine, where THCCOOH-glu was converted into THCCOOH by alkaline hydrolysis. For purification of the urine extract prior to instrumental analysis, high-speed centrifugation was used to minimize interference. In addition, an injection-port derivatization method using ethyl acetate and N,O-bis(trimethylsilyl)-trifluoroacetamide containing 1 % trimethylchlorosilane was employed to reduce the time required for derivatization, and an aliquot of the final solution was injected into the GC-MS. The method was validated by measuring the selectivity, limit of detection (LOD), and repeatability. The sensitivity, specificity, precision, accuracy, Kappa, F-measure, false positive, and false negative rate were determined by comparing the GC-MS results with those obtained using the immunoassay. The LOD was determined to be 0.32 ng/mL, while the repeatability was within 9.1 % for THCCOOH. Furthermore, a comparison study was carried out, whereby the screening immunoassay exhibited a sensitivity of 86.4 % and a specificity of 100 % compared to GC-MS. The applicability of the developed method was examined by analyzing spiked urine and forensic urine samples obtained from suspected cannabis abusers (n = 221).

엔진윤활유 중 Ethylene Glycol의 용제추출후 bistrimethylsilyltrifluoroacetamide(BSTFA)를 이용한 GC/MS 분석에 관한 연구 (GC/MS Analysis of Ethylene Glycol in the Contaminated Lubricant Oil Through Solvent Extraction Followed by Derivatization using Bistrimethylsilyltrifluoroacetamide (BSTFA))

  • 이준배;권오성;유재훈;손성건;성태명;팽기정
    • Tribology and Lubricants
    • /
    • 제28권6호
    • /
    • pp.315-320
    • /
    • 2012
  • For proper functioning, general machines usually need lubricant oil as a cooling, cleaning, and sealing agent at points of mechanical contact. The quality of lubricant oil can deteriorate during operation owing to various causes such as high temperature, combustion products and extraneous impurities. In this study, a heavy load stopped during operation, and the oil was analyzed to check whether any impurities were added. Extraction using acetonitrile followed by reaction with BSTFA(bistrimethylsilyl trifluoroacetamide) showed that, trimethylsilylated ethylene glycol was present in the lubricant oil. To quantify the ethylene glycol in the oil, deuterium-substituted ethylene glycol, which acted as an internal standard, was added to the sample and then extracted with the solvent. Next, the extract was reacted with the derivatizing agent(BSTFA) and then analyzed with GC/MS. The detection limit of this method was found to be $0.5{\mu}g/g$ and the recovery of oil containing $20,000{\mu}g/g$ of ethylene glycol was measured to be 94.8%. A damaged O-ring and eroded cylinder liner were found during the overhaul, which implied the leakage of coolant containing ethylene glycol into the lubricating system. The erosion of the cylinder liner was assumed to be due to cavitation of the coolant in the cooling system.

효율적인 HWP 악성코드 탐지를 위한 데이터 유용성 검증 및 확보 기반 준지도학습 기법 (Efficient Hangul Word Processor (HWP) Malware Detection Using Semi-Supervised Learning with Augmented Data Utility Valuation)

  • 손진혁;고기혁;조호묵;김영국
    • 정보보호학회논문지
    • /
    • 제34권1호
    • /
    • pp.71-82
    • /
    • 2024
  • 정보통신기술(ICT) 고도화에 따라 PDF, MS Office, HWP 파일로 대표되는 전자 문서형 파일의 활용이 많아졌고, 공격자들은 이 상황을 놓치지 않고 문서형 악성코드를 이메일과 메신저를 통해 전달하여 감염시키는 피해사례가 많아졌다. 이러한 피해를 막고자 AI를 사용한 악성코드 탐지 연구가 진행되고 있으나, PDF나 MS-Office와 같이 전 세계적으로 활용성이 높은 전자 문서형 파일에 비해 주로 국내에서만 활용되는 HWP(한글 워드 프로세서) 문서 파일은 양질의 정상 또는 악성 데이터가 부족하여 지속되는 공격에 강건한 모델 생성에 한계점이 존재한다. 이러한 한계점을 해결하기 위해 기존 수집된 데이터를 변형하여 학습 데이터 규모를 늘리는 데이터 증강 방식이 제안 되었으나, 증강된 데이터의 유용성을 평가하지 않아 불확실한 데이터를 모델 학습에 활용할 가능성이 있다. 본 논문에서는 HWP 악성코드 탐지에 있어 데이터의 유용성을 정량화하고 이에 기반하여 학습에 유용한 증강 데이터만을 활용하여 기존보다 우수한 성능의 AI 모델을 학습하는 준지도학습 기법을 제안한다.

손상된 OOXML 파일에서의 데이터 추출 고도화 방안 연구 (Research on Advanced Methods for Data Extraction from Corrupted OOXML Files)

  • 김지윤;김민수;박우빈;정두원
    • 정보보호학회논문지
    • /
    • 제34권2호
    • /
    • pp.193-206
    • /
    • 2024
  • 디지털 시대의 발전과 더불어, 디지털 자료의 중요성과 그로 인한 디지털 포렌식 수사의 필요성이 증가하고 있다. 그러나 디지털 증거의 수집 및 분석 과정에서 정보저장매체의 손상이나 안티포렌식 등으로 발생하는 주요 문제점인 손상된 파일의 데이터 식별 불가능으로 증거 수집이 원활하게 이뤄지지 않고 있다. 또한, 손상된 파일복구를 위한 기존 도구의 기술적 한계로 인해 복구에 어려움이 존재한다. 따라서 본 논문은 디지털 자료 생성에 활용되는 손상된 MS Office 파일의 복구 방안을 제시하고자 한다. 복구 방안 제시를 위하여 MS Office 파일 구조인 OOXML포맷을 분석하고, 기존 복구 도구의 한계를 극복하기 위한 새로운 접근 방식을 제시한다. 이를 통해 손상된 데이터를 보다 효율적으로 복구하고 식별할 수 있는 방안을 마련함으로써 디지털 포렌식 분야에서 증거 수집의 질을 향상하는데 기여하고자 한다.

비정형 대용량 데이터 입력 및 출력 시스템 설계 및 구현 (Design and Implementation of Input and Output System for Unstructured Big Data)

  • 김창수;심규철;강병준;김경환;정회경
    • 한국정보통신학회논문지
    • /
    • 제18권2호
    • /
    • pp.387-393
    • /
    • 2014
  • 컴퓨터의 보급에 따라 비정형 대용량 데이터가 범람하고 이를 효율적으로 처리하기 노력이 요구되고 있다. 이에 본 논문에서는 오피스(office) 파일(아래한글, MS-Office 등)에 입력된 데이터를 바로 XML로 변환하고, 사용자가 XML 매핑 파일을 만들어서 워드프로세서에 입력 된 데이터를 바로 추출하여 데이터베이스에 저장하는 시스템을 제안하였다. 또한, 본 시스템은 워드프로세스에 양식을 미리 작성하여 필요한 데이터를 데이터베이스에서 조회하여 워드프로세서 문서를 응용프로그램에서 오피스 파일을 생성 할 수 있다. 이는 대용량의 비정형 데이터를 활용가능하게 할 것이다.

CNN 기반 MS Office 악성 문서 탐지 (MS Office Malicious Document Detection Based on CNN)

  • 박현수;강아름
    • 정보보호학회논문지
    • /
    • 제32권2호
    • /
    • pp.439-446
    • /
    • 2022
  • 웹사이트나 메일의 첨부 파일을 이용해 문서형 악성코드의 유포가 활발하게 이루어지고 있다. 문서형 악성코드는 실행 파일이 직접 실행되는 것이 아니므로 보안 프로그램의 우회가 비교적 쉽다. 따라서 문서형 악성코드는 사전에 탐지하고 예방해야 한다. 이를 탐지하기 위해 문서의 구조를 파악하고 악성으로 의심되는 키워드를 선정하였다. 문서 내의 스트림 데이터를 아스키코드값으로 변환하여 데이터셋을 만들었다. CNN 알고리즘을 이용하여 문서의 스트림 데이터 내에 존재하는 악성 키워드의 위치를 확인하고 인접 정보를 활용하여 이를 악성으로 분류했다. 파일 내의 스트림 단위로 악성코드를 탐지한 결과 0.97의 정확도를 보였고, 파일 단위로 악성코드를 탐지한 결과 0.92의 정확도를 보였다.

HPLC-ICP-MS를 이용한 쌀의 비소 위해도 평가 (Risk Analysis of Arsenic in Rice Using by HPLC-ICP-MS)

  • 안재민;박대한;황향란;장순영;권미정;김인숙;김익로;이혜민;임현지;박재옥;이광희
    • 한국환경농학회지
    • /
    • 제37권4호
    • /
    • pp.291-301
    • /
    • 2018
  • 본 연구에서는 최근 국제적으로 논란이 되고 있는 쌀의 안전성과 관련하여, 무기비소 오염도 파악을 위한 분석법 확립과 국내에서 생산되는 쌀(현미, 백미)의 섭취량을 고려한 무기비소 위해수준을 확인하고자 하였다. 실험재료는 지역별 대표성을 고려하여 경상북도 전 지역에 걸쳐 생산된 벼 137점(현미 상태 137, 백미 가공 137)을 생산농가에서 직접 수거한 시료를 활용하였다. 총비소 분석은 일정량의 시료에 질산을 주가한 다음 microwave digestion system을 활용하여 전처리한 후 ICP-MS를 이용하여 정량 분석하였다. 무기비소 화학종의 분리 및 정량을 위하여 국제적으로 많이 활용되고 있는 HPLC를 이용하여 비소 종을 선택적으로 분리하고, 검출기 역할을 하는 ICP-MS를 결합한 형태인 HPLC-ICP-MS를 이용하여 비소 화학종을 분리하고 정량하였다. 추출 용매 선정 및 분석법 확립을 위하여 0.28 M nitric acid, 5 mM malonic acid, 그리고 1% nitric acid를 이용한 3가지 추출 방법 중 추출 효율 및 안전성 등이 가장 양호한 5 mM malonic acid를 이용한 추출법(동일한 조건으로 조제한 이동상)을 최종 시험법으로 선택하였다. 시험법 검증을 위하여 기기검출한계, 정량한계, 직선성 및 회수율 등 모두 AOAC에서 권장하는 기준을 만족하여 총비소 및 무기비소 시험법과 결과에 대한 신뢰성을 확인하였다. 비소 분석에 있어서 시료 전처리부터 기기분석까지 발생할 수 있는 다양한 분석오차 요인들을 일련의 과정을 통하여 추적한 결과, 각 불확도 요인이 전체 불확도에서 차지하는 비율은 검량곡선의 직선성 유지가 88.67%로 가장 높았고, 표준용액 제조 과정에서 11.09%, 시료 전처리 과정에서 0.24%로 가장 낮은 비율을 보였다. 현미의 총비소 함량은 평균 $0.142{\pm}0.061mg/kg$, 무기비소 함량은 평균 $0.077{\pm}0.038mg/kg$, 백미의 총비소 함량은 평균 $0.083{\pm}0.037mg/kg$, 무기비소 함량은 평균 $0.047{\pm}0.020mg/kg$으로 조사되었고, 총비소 함량 대비 무기비소 함량 비율은 53-88%(현미 평균 54.2%, 백미 평균 56.6%) 범위에 있음을 확인하였다. 우리나라 국민들의 일상적인 식이 섭취량에서 무기비소 위해 정도를 평가하였는데, 연령별 현미 섭취로 인한 1일 단위체중당 평균 노출량은 $4.97{\times}10^{-3}$(${\geq}20$세) $-1.36{\times}10^{-2}$(${\leq}2$세) ${\mu}g/kg\;b.w./day$로 위해도는 0.23-0.63% 수준으로 상당히 낮은 것으로 평가되었고, 연령별 백미 섭취로 인한 1일 단위체중당 평균 노출량은 $1.39{\times}10^{-1}$(${\geq}20$세) $-3.21{\times}10^{-1}$(${\leq}2$세) ${\mu}g/kg\;b.w./day$로 위해도는 6.47-15.00% 수준으로 백미 섭취로 인한 무기비소의 인체 노출수준 및 위해 정도는 우려할 수준이 아닌 것으로 확인되었다.