• Title/Summary/Keyword: MRI Image

Search Result 941, Processing Time 0.025 seconds

Role of MRI in Deciding on a Treatment Plan for Sciatic Nerve Palsy after Reduction of a Hip Dislocation: Case Report (고관절 탈구 정복 후 발견된 좌골 신경 마비의 자기공명영상을 통한 치료방향 결정: 증례 보고)

  • Cho, Junho;Yeo, Woon Hyung;Kim, Ji Wan
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.229-232
    • /
    • 2013
  • Traumatic fracture-dislocations of the hip frequently result from high-energy injury, and hip dislocations are commonly associated with severe concomitant injuries. Sciatic nerve injury often accompanies traumatic fracture-dislocation of the hip, but neurologic examination at the time of injury is difficult in severely traumatized patients with decreased consciousness. We present such a case of multiple traumas with traumatic hip dislocation and sciatic nerve injury after reduction, and we found that magnetic resonance image (MRI) played an important role in developing a management plan.

Comparison Study of Image Performance with Contrast Agent Contents for Brain Magnetic Resonance Imaging

  • Lee, Youngjin;Choi, Min Hyeok;Goh, Hee Jin;Han, Dong-Kyoon
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.281-285
    • /
    • 2016
  • The purpose of study was to evaluate SNR and CNR with different contrast agent contents (1.0 mmol/mL gadobutrol and 0.5 mmol/mL gadoterate meglumine) for spin echo (SE) and 3-dimension contrast-enhanced fast field echo (3D CE-FFE) pulse sequences. In this study, we compared the SNR and the CNR between 0.5 mmol/mL gadoterate meglumine and 1.0 mmol/mL gadobutrol according to the concentration of contrast agent in brain MRI. When we compared between SE and 3D CE-FFE pulse sequences, the higher SNR and CNR using 3D CE-FFE pulse sequence can be acquire regardless of contrast agent contents. Also, a statistically significant difference was found for SNR and CNR between all protocols. In conclusion, our results demonstrated that the SNR and CNR have not risen proportionately with contrast agent contents. We hope that these results presented in this paper will contribute to decide contrast agent contents for brain MRI.

Development of MRI gradient waveform generator using DSP (DSP를 이용한 자기공명영상의 경사자계 파형 발생기 개발)

  • Ko, K.H.;Kwon, E.S.;Song, Y.C.;Kim, H.J.;Yim, C.Y.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3147-3149
    • /
    • 1999
  • In this paper, we develop a TMS320C31- 60 DSP board to generate spiral gradient waveforms for Spiral imaging, one of the ultra fast MRI methods. In Spiral imaging, accurate gradient waveforms are very important to acquire high quality image. For this purpose, sampling rate for generating the gradient waveforms is set twice as high as the data sampling rate. With the developed DSP board accurate gradient waveforms are obtained. Ultra fast MR image with the developed DSP board is currently under development.

  • PDF

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Study on Image Improvement Method for Coronary Artery Imaging

  • 류연철;류승학;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.142-142
    • /
    • 2001
  • 목적: 관상동맥의 이상으로 인해 여러 가지 심장 관련 질환이 발병하기 때문에 관상동맥을 관찰할 수 있는 영상기법의 필요성이 늘어남은 물론 세계적으로 Cardiac 영상 기법 개발이 활발하게 진행되어 지고 있다. MRI System을 이용한 관상동맥(Coronary Artery) Image는 여러 가지 움직임 때문에 사용할 수 있는 영상기법에 제한을 받게 된다 가장 큰 제약은 심장의 움직임에 관한 것인데 이러한 움직임은 ECG Gating을 사용하여 극복할 수 있다. 본 논문에서는 관상 동맥을 촬영하는 영상기법의 개발과 촬영된 영상을 재처리하는 기법을 소개 하고자 한다 ECG Gating을 이용한 영상 기법 및 얻어진 영상을 Morphology, MIP를 이용한 Image processing을 하여 얻어진 영상을 enhance시켜 보았다.

  • PDF

Rotter estimation of ″sum-of-squres″ to improve the reconstructed image quality in Sensitivity Encoding (SENSE)

  • Yun, Sung-Dae;Song, Myung-Sung;Chung, Jun-Young;Park, Hyun-Wook
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.72-72
    • /
    • 2003
  • In SENSE, division process is used in order to get a raw sensitivity map. This process requires denominator which is estimated by "sum-of-squres". However, this image does not have uniformbrightness because of the non-symmetrical property of RF coil arrays. Thus, this study is focused on better estimation of the denominator image.

  • PDF

Medical image control process improvement based on Cardiac PACS (Cardiac PACS 구축에 따른 의료영상 관리 프로세스 개선)

  • Jung, Young-Tae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • Heart related special images are classified as Cardiac US, XA, CT, MRI. Several Problem is caused by image compression, control and medical support point, so most big hospitals have created a Cadiac PACS differentially in past years. For this reason, create a conflict in inner colleague and patient, protector that result from 2 data processing server operating independently in 1 medical center area. For this reason, we sugges an alternative model of best medical control process together with understand the current situation on medical facility.

  • PDF

Comparison the Preoperative MRI Findings with Postoperative Arthroscopic Findings on Meniscus Injury with Anterior Cruciate Ligament Rupture (전방십자인대 파열에 동반된 반월상 연골판 손상의 관절경 수술 소견과 수술 전 자기공명영상 검사와의 비교)

  • Sohn, Hong Moon;Lee, Gwang Chul;Kim, Dong Hwi;Park, Sang Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.147-152
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the preoperative magnetic resonance image (MRI) findings with postoperative arthroscopic findings on meniscus injury with anterior cruciate ligament (ACL) rupture. Materials and Methods: We reviewed MRI images and arthroscopic findings of 225 patients treated by ACL reconstruction due to rupture, from February 2001 to November 2010. There were 154 cases of meniscus tear in arthroscopic findings. We examined the sensitivity for detecting meniscal tears varied with the presence of a rupture of the ACL, with the location of the tear within the meniscus, and among configurations of meniscal tears. Results: In the presence of a rupture of the ACL, the sensitivity of MRI was 0.88 for medial meniscal tears and 0.69 for lateral meniscal tears. And sensitivity of MRI was lowest in posterior horn and peripheral portion tears in lateral meniscus injury accompanying ACL rupture, sensitivity was low in anterior horn and flap shape tears in medial meniscus injury accompanying ACL rupture. Conclusion: In Meniscus injury with ACL rupture, a special attention shoulder given to the posterior horn and peripheral portion injury in lateral meniscus during arthroscopic surgery due to difficulty in detecting on MRI.

  • PDF