DOI QR코드

DOI QR Code

Comparison Study of Image Performance with Contrast Agent Contents for Brain Magnetic Resonance Imaging

  • Received : 2016.02.22
  • Accepted : 2016.03.30
  • Published : 2016.06.30

Abstract

The purpose of study was to evaluate SNR and CNR with different contrast agent contents (1.0 mmol/mL gadobutrol and 0.5 mmol/mL gadoterate meglumine) for spin echo (SE) and 3-dimension contrast-enhanced fast field echo (3D CE-FFE) pulse sequences. In this study, we compared the SNR and the CNR between 0.5 mmol/mL gadoterate meglumine and 1.0 mmol/mL gadobutrol according to the concentration of contrast agent in brain MRI. When we compared between SE and 3D CE-FFE pulse sequences, the higher SNR and CNR using 3D CE-FFE pulse sequence can be acquire regardless of contrast agent contents. Also, a statistically significant difference was found for SNR and CNR between all protocols. In conclusion, our results demonstrated that the SNR and CNR have not risen proportionately with contrast agent contents. We hope that these results presented in this paper will contribute to decide contrast agent contents for brain MRI.

Keywords

References

  1. A. Lignelli and A. G. Khandji, Neurosurg. Clin. N. Am. 22, 15 (2011). https://doi.org/10.1016/j.nec.2010.09.002
  2. C. P. Kellner and A. L. D'Ambrosio, Neurosurg. Clin. N. Am. 22, 53 (2011). https://doi.org/10.1016/j.nec.2010.08.003
  3. K. Yokoi, N. Kamiya, H. Matsuguma, S. Machida, T. Hirose, K. Mori, and K. Tominaga, Chest 115, 714 (1999). https://doi.org/10.1378/chest.115.3.714
  4. T. C. Ryken, M. McDermott, P. D. Robinson, M. Ammirati, D. W. Andrews, A. L. Asher, S. H. Burri, C. S. Cobbs, L. E. Gaspar, D. Kondziolka, M. E. Linskey, J. S. Loeffler, M. P. Mehta, T. Mikkelsen, J. J. Olson, N. A. Paleologos, R. A. Patchell, S. N. Kalkanis, and G. C. Giakos, J. Neurooncol. 96, 103 (2010). https://doi.org/10.1007/s11060-009-0057-4
  5. R. Soffietti, R. Ruda, and R. Mutani, J. Neurol. 249, 1357 (2002). https://doi.org/10.1007/s00415-002-0870-6
  6. A. A. Postma, P. A. M. Hofman, A. A. R. Stadler, R. J. van Oostenbrugge, M. P. M. Tijssen, and J. E. Wildberger, AJR 199, S26 (2012). https://doi.org/10.2214/AJR.12.9115
  7. P. C. Davis, P. A. Hudgins, S. B. Peterman, and J. C. Hoffman, AJNR 12, 293 (1991).
  8. M. Filippi, T. Yousry, C. Baratti, M. A. Horsfield, S. Mammi, C. Becker, R. Voltz, S. Spuler, A. Campi, M. F. Reiser, and G. Comi, Brain 119, 1349 (1996). https://doi.org/10.1093/brain/119.4.1349
  9. T. Barrett, H. Kobayashi, M. Brechbiel, and P. L. Choyke, Eur. J. Radiol. 60, 353 (2006). https://doi.org/10.1016/j.ejrad.2006.06.025
  10. U. I. Attenberger, V. M. Runge, C. B. Jackson, S. Baumann, K. Birkemeier, H. J. Michaely, S. O. Schoenberg, M. F. Reiser, and B. J. Wintersperger, Invest. Radiol. 44, 251 (2009). https://doi.org/10.1097/RLI.0b013e31819ba711
  11. B.-D. Jo, Y.-J. Lee, D.-H. Kim, and H.-J. Kim, J. Kor. Phys. Soc. 65, 541 (2014). https://doi.org/10.3938/jkps.65.541
  12. P. H. Kuo, E. Kanal, A. K. Abu-Alfa, and S. E. Cowper, Radiology 242, 647 (2007). https://doi.org/10.1148/radiol.2423061640
  13. J. Biswas, C. B. Nelson, V. M. Runge, B. J. Wintersperger, S. S. Baumann, C. B. Jackson, and T. Patel, Invest. Radiol. 40,792 (2005). https://doi.org/10.1097/01.rli.0000187609.78338.dc
  14. K. J. Chang, I. R. Kamel, K. J. Macura, and D. A. Bluemke, RadioGraphics 28, 1983 (2008). https://doi.org/10.1148/rg.287075154

Cited by

  1. Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta vol.26, pp.4, 2016, https://doi.org/10.4283/JKMS.2016.26.4.142