• Title/Summary/Keyword: MRA Method

Search Result 78, Processing Time 0.02 seconds

The Value of Comparison with Four Dimension Time Resolved Imaging of Contrast Kinetics(TRICKS) MRA by Time of Flight(TOF) MRA (4차원 TRICKS 자기공명혈관조영술과 기존 TOF 자기공명혈관조영술의 비교 및 유용성)

  • Bae, Sung-Jin;Lim, Cheong-Hwan;Park, Byung-Rae;Shin, Woon-Jae;Kim, Jung-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.215-221
    • /
    • 2010
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography (4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성)

  • Lim, cheong-hwan;Bae, sung-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1105-1110
    • /
    • 2009
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

  • PDF

Evaluation of Image Quality for Compressed SENSE(CS) Method in Cerebrovascular MRI: Comparison with SENSE Method (뇌혈관자기공영영상에서 Compressed SENSE(CS) 기법에 대한 영상의 질 평가: SENSE 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.999-1005
    • /
    • 2021
  • The object of this research is CS, which increases resolution while shortening inspection time, is applied to MRA to compare the quality of images for SENSE and CS techniques and to evaluate SNR and CNR to find out the optimal techniques and to provide them as clinical basic data based on this information. Data were analyzed on 32 patients who performed TOF MRA tests at a university hospital in Chung cheong-do (15 males, 17 females), ICA stenosis:10, M1 Aneurysm:10, and average age 53 ± 4.15). In the inspection, the inspection equipment was Ingenia CX 3.0T, Archieva 3.0T, and 32 channel head coil and 3D gradient echo as a method for equipment data. SNR and CNR of each image were measured by quantitative analysis, and the quality of the image was evaluated by dividing the observer's observation into 5 grades for qualitative evaluation. Imaging evaluation is described as being significant when the p-value is 0.05 or less when the paired T-test and Wilcoxon test are performed. Quantitative analysis of SNR and CNR in TOF MRA images Compared to the SENSE method, the CS method is a method measurement method (p <0.05). As an observer's evaluation, the sharpness of blood vessels: CS (4.45 ± 0.41), overall image quality: CS (4.77 ± 0.18), background suppression of images: CS (4.57 ± 0.18) all resulted in high CS technique (p = 0.000). In conclusion, the Compressed SENSE TOF MRA technique shows superior results when comparing and evaluating the SENSE and Compressed SENSE techniques in increased flow rate magnetic resonance angiography. The results are thought to be the clinical basis material in the 3D TOF MRA examination for brain disease.

Hemodynamically Induced Aneurysm-mimicking Findings at Anterior Communicating (A-com) Artery Area due to Anatomical Variation on 3D-TOF MRA

  • 강원석;정태섭;심용운;유병규;박인국
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.133-133
    • /
    • 2001
  • Purpose: To determine the relationship between anatomical variation at A-com. artery area an hemodynamically induced aneurysm-mimicking findings on 3D-TOF MRA clinically a experimentally. Method: Sixty-two patients who had no aneurysm at A-com artery on DSA were evalua with MRA. MRA was performed with 1.5T MR machine(Vision, Siemens). Scan parameters o MRA included TR/TE/FA=30/6.4/25$\psi$$\circledR$˙¡, 512*192 of matrix with MIP technique. The occurrence of signal defect at shoulder area of bifurcated A-com artery on MRA was evalua for the relationship between the symmetricity of bilateral ACA and the patency of A-c artery. DSA images were acquired at both ICA and VA. To analyze hemodynamical facto of signal defect, experimental studies of MRA and DSA were peformed with elastic silic phantom using conducting pulsatile pump. We also compared the results with those o computational fluid dynamics(CFD).

  • PDF

Principles of Magnetic Resonance Angiography Techniques

  • Shin, Taehoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.209-217
    • /
    • 2021
  • Magnetic resonance angiography (MRA) plays an important role in accurate diagnosis and appropriate treatment planning for patients with arterial disease. Contrast-enhanced (CE) MRA is fast and robust, offering hemodynamic information of arterial flow, but involves the risk of a side effect called nephrogenic systemic fibrosis. Various non-contrast-enhanced (NCE) MRA techniques have been developed by utilizing the fact that arterial blood is moving fast compared to background tissues. NCE MRA is completely free of any safety issues, but has different drawbacks for various approaches. This review article describes basic principles of CE and NCE MRA techniques with a focus on how to generate angiographic image contrast from a pulse sequence perspective. Advantages, pitfalls, and key applications are also discussed for each MRA method.

Computer Simulation and MRA Observation for Steady Flow in the Carotid Arterial Bifurcation (경동맥 분지관내 정상유동에 대한 컴퓨터 시뮬레이션과 MRA 관찰)

  • Suh, S.H.;Cho, M.T.;Yoo, S.S.;Chung, T.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.73-76
    • /
    • 1996
  • Computer simulation and magnetic resonance angiograms(MRAs) are used to understand for flow patterns in the carotid arterial bifurcation. Steady momentum equation is solved by the finite volume method. A Phantom of the carotid artery made of bioacrylic material is used for MRA observation. Flow Patterns are observed by using MRA for flow in the phantom of an automatic closed-type circulatory system filled with sugar 4 w% solution. For numerical analysis the idealized geometric shape of the carotid artery is constructed to portray the phantom. Results of numerical analysis are compared with those of MRA. The flow patterns of the phantom on MRA are almost identical to those of the computer simulation.

  • PDF

A Study on Selection of Optimal Imaging Diagnostic Device for Cerebral Angiography: Focusing on MRA, CTA, and DSA Imaging Diagnosis Devices (뇌혈관 검사 시 최적의 영상 진단장치 선정에 관한 연구: MRA, CTA, DSA, 영상 진단장치 중심으로)

  • Byun, Jung-Su;Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.637-645
    • /
    • 2017
  • The objective of this study was to find the optimum test device for the cerebral blood vessels by comparing and analyzing the SNR and CNR methods for images of three devices (i.e., MRA, CTA, and DSA). The study targeted 90 patients who underwent cerebral angiography from November 2016 to May 2017. The measuring parts were measured by using Rt MCA, Lt MCA, and ACA Image J. The results of quantitative analysis showed that the mean SNR of MRA, the CNR of MRA, the signal strength of MRA, the mean SNR of CTA, the CNR of CTA, the signal strength of CTA, the SNR of DSA, the CNR of DSA, and the signal strength of DSA were evaluated as 254.87, 178.13, 326.81, 74.75, 62.2, 356.66, 26.85, 25.89, and 4400.69, respectively (p<0.05). As a result, both SNR and CNR methods measured it in the order of MRA>CTA>DSA. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis SPSS. In conclusion, the results of this study revealed that the optimum imaging devices were MRA, CTA, and DSA after evaluating randomly selected patients with cerebrovascular disease.

The economic effect of Korea-EFTA Mutual Recognition Agreement in the pharmaceutical industry using Conditional Valuation Method (CVM) (조건부가치평가법(CVM)을 이용한 한-EFTA간 제약 산업 상호인정협약 체결의 경제적 효과 분석)

  • Kwon, Tae-Hyuk;Lee, Sang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.389-398
    • /
    • 2018
  • An MRA is considered to be an important policy tool within the WTO for overcoming technical barriers to trade. A number of studies on the economic impact of MRAs have demonstrated their positive economic effects. However, no studies have been conducted on MRAs in the pharmaceutical industry since analysis has been limited to industries as a whole or certain industries where some data were accumulated. Therefore, this paper analyzed the economic impact of MRAs for GMP inspection exemption in the pharmaceutical industry through the Conditional Valuation Method (CVM), a valuation technique for non-market goods. Pharmaceutical companies were asked whether or not they were willing to pay for the Korea-EFTA MRA through double-bounded dichotomous choice (DBDC) questions. The final WTP was estimated using the utility difference model developed by Hanemann (1984). As a result, annual economic effects on the pharmaceutical industry were estimated to be between KRW7.03 billion to KRW15.8 billion.

Comparative Evaluation of North American Symptomatic Carotid Endarterectomy Trial and Warfarin-Aspirin Symptomatic Intracranial Disease Methods for Measurement of Middle Cerebral Artery Stenosis in Digital Subtraction Angiography and Magnetic Resonance Angiography (디지털 감산 혈관조영술과 자기 공명 혈관조영술에서 중대뇌동맥의 협착 측정을 위한 North American Symptomatic Carotid Endarterectomy Trial 및 Warfarin-Aspirin Symptomatic Intracranial Disease 방법의 비교 평가)

  • Lee, Jung-Hoon;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.351-356
    • /
    • 2019
  • This study aimed to determine whether there was a difference in measurements between North American Symptomatic Carotid Endarterectomy Trial(NASCET) and Warfarin-Aspirin Symptomatic Intracranial Disease(WASID) methods that measure the middle cerebral artery stenosis in Digital Subtraction Angiography (DSA) and Magnetic Resonance Angiography (MRA). It involved 24 patients who had completed both DSA and MRA among patients with Middle Cerebral Artery (MCA) stenosis. The Middle Cerebral Artery (MCA) stenosis was measured using the NASCET and WASID methods through a retrospective analysis. For the NASCET and WASID methods, they performed measurements on normal blood vessels located far from and close to the stenosis, respectively. The mean value and standard deviation of the Digital Subtraction Angiography (DSA) measured by the NASCET method were 59.23% and 13.27%. On the other hand, those of the Digital Subtraction Angiography (DSA) measured by the WASID method were 66.64% and 12.47%. And, the mean value and standard deviation of the Magnetic Resonance Angiography (MRA) measured by the NASCET method were 49.82% and 12.06%. By contrast, those of the Magnetic Resonance Angiography (MRA) measured by the WASID method were 56.63% and 10.67%. All the p-values obtained by the Pearson and Spearman correlation tests in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) were <0.01. In conclusion, this study suggests that both the NASCET and WASID methods to measure the middle cerebral artery stenosis in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) can be used if they are not used interchangeably.

IMPROVEMENT OF FLOW SIMULATIONS METHOD WITH MULTI-RESOLUTION ANALYSIS BY BOUNDARY TREATMENT (경계면 처리 개선을 통한 다중해상도 유동해석 기법 개선 연구)

  • Kang, H.M.
    • Journal of computational fluids engineering
    • /
    • v.20 no.4
    • /
    • pp.44-50
    • /
    • 2015
  • The computational efficiency of flow simulations with Multi-resolution analysis (MRA) was enhanced via the boundary treatment of the computational domain. In MRA, an adaptive dataset to a solution is constructed through data decomposition with interpolating polynomial and thresholding. During the decomposition process, the basis points of interpolation should exceed the boundary of the computational domain. In order to resolve this problem, the weight coefficients of interpolating polynomial were adjusted near the boundaries. By this boundary treatment, the computational efficiency of MRA was enhanced while the numerical accuracy of a solution was unchanged. This modified MRA was applied to two-dimensional steady Euler equations and the enhancement of computational efficiency and the maintenance of numerical accuracy were assessed.