• Title/Summary/Keyword: MR spectroscopy

Search Result 143, Processing Time 0.028 seconds

Human in-vivo 31P MR Spectroscopy of Benign and Malignant Breast Tumors

  • Jeong Mi Park;Jae Hyung Park
    • Korean Journal of Radiology
    • /
    • 제2권2호
    • /
    • pp.80-86
    • /
    • 2001
  • Objective: To assess the potential clinical utility of in-vivo 31P magnetic resonance spectroscopy (MRS) in patients with various malignant and benign breast lesions. Materials and Methods: Seventeen patients with untreated primary malignant breast lesions (group I), eight patients with untreated benign breast lesions (group II) and seven normal breasts (group III) were included in this study. In-vivo 31P MRS was performed using a 1.5 Tesla MR scanner. Because of the characteristics of the coil, the volume of the tumor had to exceed 12 cc (3×2×2 cm), with a superoinferior diameter at least 3 cm. Mean and standard deviations of each metabolite were calculated and metabolite ratios, such as PME/PCr, PDE/PCr, T-ATP/PCr and PCr/T-ATP were calculated and statistically analyzed. Results: Significant differences in PME were noted between groups I and III (p=0.0213), and between groups II and III (p=0.0213). The metabolite ratios which showed significant differences were PME/PCr (between groups II and III) (p=0.0201), PDE/PCr (between groups I and III, and between groups II and III) (p=0.0172), T-ATP/PCr (between groups II and III) (p=0.0287), and PCr/T-ATP (between groups II and III) (p=0.0287). There were no significant parameters between groups I and II. Conclusion: In-vivo 31P MRS is not helpful for establishing a differential diagnosis between benign and malignant breast lesions, at least with relatively large lesions greater than 3 cm in one or more dimensions.

  • PDF

Hyperpolarization: Sensitivity Boost in Magnetic Resonance Spectroscopy and Imaging

  • Ko, Hyeji;Gong, Gyeonghyeon;Jeong, Gijin;Choi, Ikjang;Seo, Hyeonglim;Lee, Youngbok
    • 한국자기공명학회논문지
    • /
    • 제19권3호
    • /
    • pp.124-131
    • /
    • 2015
  • Hyperpolarization methods are the most emerging techniques in the field of magnetic resonance (MR) researches since they make a contribution to overcoming sensitivity limitation of MR spectroscopy and imaging, leading to new fields of researches, real-time in vivo metabolic/molecular imaging and MR analysis of chemical/biological reactions in non-equilibrium conditions. Make use of enormous signal enrichments, it becomes feasible to investigate various chemical and biochemical systems with low ${\gamma}$ nuclei in real-time. This review deals with the theoretical principals of common hyperpolarization methods and their experimental features. In addition, more detailed theories, mechanisms, and applications of dissolution dynamic nuclear polarization (D-DNP) are discussed.

유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구 (Investigation of Correlations of Double Inversion Recovery and MR Spectroscopy on Breast MR Imaging)

  • 류정규;이선정;장건호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권1호
    • /
    • pp.34-42
    • /
    • 2014
  • 목적 : 유방암의 이중반전회복 자기공명영상 (double inversion recovery, DIR) 신호와 자기공명분광영상기법 (MR spectroscopy, MRS)에서 얻은 단일 화적소 콜린 양과 상관관계가 있는가를 알아보고자 하였다. 대상 및 방법 : 2008년 8월부터 2009년 12월까지 유방암으로 진단된 환자 중 이중반전회복 자기공명영상과 자기공명분광영상기법 모두를 시행한 28명의 환자를 대상으로 하였다. 이중반전회복영상과 조영증강 T1강조영상 (CE-T1WI)에서 종양에 해당하는 관심영역에서의 신호강도를 삼차원으로 얻었으며 병변 (L)과 동측 정상 섬유선 조직 (N)에 대한 용적을 같은 레벨에서 병변 대 정상조직의 신호강도 비 (LNR)를 구하였다. 자기공명분광영상 데이터는 단일복셀분광방법인 중점분해분광학을 이용하였다. 자기공명분광영상기법에서 총 콜린 공명의 높이, 폭, 면적과 조영증강 T1강조영상에서 병변 대 정상 조직의 신호강도 비 값, 그리고 이중반전회복 자기공명영상의 병변 대 정상조직의 신호강도비 값 간의 상관 관계에 대해 Pearson 상관분석을 시행하였고 유의수준은 p=0.05이었다. 결과 : 조영증강 T1강조영상의 병변 대 정상 조직의 신호강도 비 값과 자기공명분광영상기법에서 콜린의 높이 (r=-0.322, p= 0.094), 폭 (r=-0.233, p=0.232), 면적 (r=-0.309 p=0.109)값과, 또한 이중반전회복 자기공명영상의 병변 대정상 조직의 신호강도 비 값과 자기공명분광영상기법 콜린의 높이 (r=0.067, p=0.735), 폭 (r=-0.287, p=0.139), 면적 (r=0.012 p=0.953) 값 사이에 상관성은 통계적으로 유의하지 않았다. 조영증강 T1강조영상의 병변 대 정상조직의 신호강도 비 값과 이중반전회복 자기공명영상의 병변 대 정상조직의 신호강도 비 값 사이에서도 Pearson상관계수 0.186으로 두 군간에 관련성은 없었다 (p=0.344). 결론 : 이중반전회복 자기공명영상에서 유방암의 병변 대 정상조직간 신호강도 비와 자기공명분광영상에서의 콜린 공명의 상대적인 양은 서로 상관관계를 보이지 않았다.

Assessment of Malignancy in Brain Tumors by 3T MR Spectroscopy

  • 최보영;전신수;이재문;정성택;안창범;오창현;김선일;이형구;서태석
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.76-76
    • /
    • 2003
  • Purpose: To assess clinical proton MR spectroscopy (MRS) as a noninvasive method for evaluating tumor malignancy at 3T high field system. Methods: Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. Results: The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67$\pm$018 and 1.16:1:0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (P=0.005). Cho/Cr ratio of high-grade gliomas was significantly higher than that of low-grade gliomas (P= 0.001), Except 4 menigiomas, lactate signal was observed in all tumor cases. Conclusions: The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. This results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy. Acknowledgement: This study was supported by a grant of the Mid and Long Term Nuclear R/D Plan Program, Ministry of Science and Technology, Republic of Korea.

  • PDF

생체내에서 인의 핵자기공명 분광분석을 위한 방사형 주사기법 (Radial Scanning Technique for 31P MR Spectroscopy In Vivo)

  • 임채열;천강욱;나종범;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 춘계학술대회
    • /
    • pp.39-42
    • /
    • 1990
  • 지난 수년동안 MR을 이용한 생체내의 인의 분광을 얻기 위한 여러가지 방법들이 연구되었다. 그러나 대부분의 방법들은 선택시간의 지연으로 인하여 선택된 체적에서의 FID 신호가 짧은 T2 시간에 영향을 받았다. 본 논문에서는 인의 분광법으로 적절한 새로운 방법을 제시하였다. 이 방법은 k-공간을 방사형으로 스캔하면서 이루어지는 더 짧은 선택시간으로 T2 감쇄의 영향을 거의 받지 않으며, 좋은 선택도를 얻을 수 있었다.

  • PDF

두개강내 고형성 종양의 H-1 자기공명분광법 (In Vivo H-1 MR Spectroscopy of Intracranial solid Tumors)

  • 성수옥;장기현;한문희;연경모;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.86-93
    • /
    • 1997
  • 목적: 두개강내 고형성 종야에서 병리조직학적 진단과 악성도에 따라 특징적 H-1자기공명분광(MRS) 양상이 나타나는지를 알아보고자 하였다. 대상 및 방법: 고형성 뇌종양 환자 81명(저등급 교종 17예, 고등ㅇ급 교종 31예, 림프종 9예, 뇌수막종 8예, 신경세포종 4예, 수아세포종 3예, 원시성신경외배엽종 3예, 전이암 2예, 기타 4예)을 대상으로 생체내 MRS를 시행하여 스펙트럼을 분석하였다. MRS는 1.5T 장치를 사용하여 PRESS기법으로 TR/TE 2000/270msec, VOI $2{\times}2{\times}2cm^3$로 얻었다. 대사 산물의 공명(resonance) 분석은 N-acetyl aspartate(NAA)/Creatine complix(Cr)비, Choline complex(Cho)/Cr비, Lactate(Lac)/Cr비를 구하였으며, 기타 산물에 대하여는 기존의 문헌에 기초하여 존재 유무를 분석하였다. 결과: 모든 고형성 뇌종양에서 NAA는 감소하고, Cho과 lactate는 증가하였다. Cr은 증가하거나 감소하는 등 다양한 결과를 보였다. 모든 종야에서 NAA/Cr이 감소한 반면, Cho/Cr과 Lac/Cr은 증가하였다. 고등급 교종에서는 평균 Cho/Cr과 lactate/Cr이 각각 저등급 교종에 비해 모두 유의하게 높았다(Cho/Cr ; $2.4{\pm}0.7{\;}vs.{\;}1.7{\pm}0.8,{\;}P<0.05,{\;}lactate/Cr{\;};{\;}1.3{\pm}1.9{\;}vs.{\;}0.4{\pm}0.6$, P<0.05). 그러나 NAA/Cr은 유의한 차이가 없었다. 뇌수막종과 신경세포종, 수아세포종에서 Cho/Cr이 고등급 교종의 수준 이상으로 높았다. 결론: H-1 MRS는 고형성 뇌종에서 저등급과 고등급 교종의 감별에 유용하게 이용될 수 있으나, 교종이외의 고형성 양성종양에서도 고등급 교종과 같은 양상을 보이므로 한게가 있다고 생각된다.

  • PDF

가돌리늄 조영제 주입에 따른 1H-MRS spectrum의 정량적 비교 (Quantitative Comparison of 1H-MRS Spectra Depending on the Paramagnetic Gadolinium Contrast Agent(GBCA) Injection)

  • 최관우;손순룡;유병규
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.589-595
    • /
    • 2017
  • 본 연구는 1H-MRS 검사 시 조영제 사용이 대사물질의 spectrum에 어떤 영향을 미치는지 비교 분석함으로써, 조영제 주입 후 MRS 시행의 가능성을 알아보고자 하였다. 연구방법은 2017년 1월부터 동년 5월까지 뇌 MRI 검사를 시행한 30명을 대상으로, 조영제 주입 전, 후 전두엽 백질 부분의 spectrum을 획득하여 뇌 조직의 대사물질 spectrum을 비교평가 하였다. 연구결과, 조영제를 주입할 경우 각 대사물질의 spectrum은 통계적으로 의미가 없어 조영제 사용이 대사물질의 spectrum에 영향을 미치지 않음을 알 수 있었다. 결론적으로 대조도가 떨어져 병변의 위치파악이 힘든 경우 정확한 위치의 spectrum을 얻기 위해선 조영제를 사용하여 대조도를 높인 다음 MRS를 시행하는 것이 바람직 할 것으로 사료된다.

뇌의 양성자 핵자기공명 분광학을 위한 정량화 방법 개발 (The Development of Quantification Technique for Brain In vivo Proton NMR Spectroscopy)

  • 강해진
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.31-39
    • /
    • 2001
  • 핵자기공명분광학(NMR Spectroscopy)을 이용해서 우리는 생물체의 조직안에 있는 각종 대사물질들을 측정할 수 있게 되었으며, 이것은 또 지금까지 알려진 여러 방법 중에서 생물체내의 신진대사 물질이나 생화학적인 변화를 비침습적(noninvasive)으로 알아낼 수 있는 유일한 방법에 속한다. 양성자 핵자기공명분광학은 최근들어 사람이나 흑은 동물뇌의 생화학적인 특성을 연구하는데 많이 사용되어오고 있다. 핵자기공명영상은 주로 물분자에 있는 양성자의 밀도와 그들의 이완현상(relaxation phenomena)을 측정하여 영상화하지만 핵자기공명분광학은 생체조직내의 신진대사에 관한 생화학적인 정보를 제공한다. 많은 경우에 있어서 핵자기공명분광학은 CT나 MRI 영상에서는 발견할 수 없는 정보를 제공함으로써 특정질병의 진단에 사용될 수 있으며, 따라서 환자들의 질병상태를 효과적으로 진단하는데 쓰여질 수 있다. 따라서 본 연구에서는 사람의 뇌에서 수소 핵자기공명분광학을 이용하여 대사물질들의 농도를 정량화하는 방법을 시도하였다. 이를 위해 펀텀을 이용하여 대사물질들 각각의 스팩트럼을 구했고, 성인 남녀 16명을 대상으로 insula gray matter 부위의 대사물질들의 농도를 측정하였다. 그리고 이 값들은 다른 연구자들에 의해 밝혀진 값들과 매우 근사한 값을 제공하였다.

  • PDF

2-Dimensional MR Spectroscopy

  • 최보영
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2008년도 MR연수강좌
    • /
    • pp.152-169
    • /
    • 2008
  • PDF