The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

Measurement of Viscoelastic Constants from Multiple Phase MR Elastography Fitting Elastic Wave (탄성파를 적용한 다중 위상 MR Elastography로부터의 점탄성 정수의 측정)

  • Jung, Nam-Chae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.3
    • /
    • pp.119-129
    • /
    • 2012
  • In the medical field, the hardening of tissues is one of important informations used in diagnosis or understanding progress of disease, a quantitative measuring method of hardening is important for objective diagnosis. It has been proposed MRE(Magnetic Resonance Elastography) method that measures an index of hardening, viscoelastic properties in a noninvasive. Because the S/N ratio of MRE images go down when measuring viscoelastic properties from local wavelength and local damping factor of a propagating wave in MRE method, methods using multiple phase MRE images have been examined to decrease the effect of noise. We propose a method measuring viscoelastic properties after Fitting a function for multiple phase MRE images in this research. This proposed method has a advantage to set up arbitrarily the variation rate of a space direction of viscoelastic properties or the spatial resolution of measuring values according to changing of the noise included in images, though it applies viscoelastic wave for multiple phase MRE images. We confirmed the effectiveness of a proposed method by experiment using simulation images and experiment using silicone-gel phantom.

Evaluation of UTE Signal Acquisition Efficacy in Molecular MRI (분자 MR영상에서 UTE 신호의 효용성 평가)

  • Lee, Sang-Bock;Choi, Gui-Rack
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.305-311
    • /
    • 2012
  • This study compares the TE and UTE is to evaluate. We was programming by DWT of Matlab Tool-box for evaluation. M-program used feature value extract between TE Images and UTE Images. Two images using the extracted feature values were compared. Comparison of similar features two images phase was found to have value.

Evaluation of Hydration Effect on Human Skin by $^1H$ MRS at 14.1T

  • Choi Chi-Bong;Hong Sung-Tak;Choe Bo-Young;Woo Dong-Chul;Yoon Seong-Ik;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.105-114
    • /
    • 2006
  • Purpose: We achieved high resolution MR imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and evaluated the hydration effect of various cosmetic products by measuring the skin's. moisture concentration. Materials and Methods: We used the Bruker 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.1 T system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field NMR instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

Efficiency of Median Modified Wiener Filter Algorithm for Noise Reduction in PET/MR Images: A Phantom Study (PET/MR 영상에서의 팬텀을 활용한 노이즈 감소를 위한 변형된 중간값 위너필터의 적용 효율성 연구)

  • Cho, Young Hyun;Lee, Se Jeong;Lee, Youngjin;Park, Chan Rok
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.225-229
    • /
    • 2021
  • The digital image such as medical X-ray and nuclear medicine field mainly contains noise distribution. The noise degree in image degrades image quality. That is why, the noise reduction algorithm is efficient for medical image field. In this study, we confirmed effectiveness of application for median modified Wiener filter (MMWF) algorithm for noise reduction in PET/MR image compared with median filter image, which is used as conventional noise redcution algorithm. The Jaszczak PET phantom was used by using 18F solution and filled with NaCl+NiSO4 fluids. In addition, the radioactivity ratio between background and six spheres in the phantom is maintained to 1:8. In order to mimic noise distribution in the image, we applied Gaussian noise using MATLAB software. To evlauate image quality, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used. According to the results, compared with noise image and images with MMWF algorithm, the image with MMWF algorithm is increased approximately 33.2% for CNR result, decreased approximately 79.3% for COV result. In conclusion, we proved usefulness of MMWF algorithm in the PET/MR images.

Improved Focal Liver Lesion Detection by Increasing Flip Angle During Gadoxetic Acid-Enhancement in MRI (Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2015
  • To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)'s enhanced MR imaging with a flip angle (FA) of $30^{\circ}$ compared with a $11^{\circ}$. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA $11^{\circ}$ and $30^{\circ}$ images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA $30^{\circ}$ images was found to be superior than FA $11^{\circ}$, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA $30^{\circ}$ image(p<0.05) was better than FA $11^{\circ}$ therefore, the FA $30^{\circ}$ improves the focal liver lesion detection. FA $30^{\circ}$ of MR image can detect liver lesion more sensitively than the existing $FA11^{\circ}$ image after GA contrast enhancement at 15 minute time point.

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF

MREIT Conductivity Imaging of Pneumonic Canine Lungs: Preliminary Post-mortem Study

  • Kim, Hyung-Joong;Kim, Young-Tae;Jeong, Woo-Chul;Minhas, Atul S.;Lee, Tae-Hwi;Lim, Chae-Young;Park, Hee-Myung;Kwon, O-Jung;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.94-98
    • /
    • 2010
  • In magnetic resonance electrical impedance tomography (MREIT), a current-injection MR imaging method is adopted to produce a cross-sectional image of an electrical conductivity distribution in addition to MR images. The purpose of this study was to test the feasibility of MREIT for differentiating the canine lung parenchyma without and with pneumonia. Three normal healthy beagles and two mixed breed dogs with pneumonia were used. After attaching electrodes around the chest, we placed the dog inside our MR scanner. We injected as much as 30 mA current in a form of short pulses into the chest region. Reconstructed conductivity images of normal canine lungs exhibit a peculiar pattern of a relatively coarse salt and pepper noise. On the contrary, conductivity images of pneumonic canine lungs show significantly enhanced contrast of the lesions while the corresponding MR images show a little bit of contrast in the middle and caudal lung parenchyma due to the accumulation of pleural fluid. This preliminary study indicates that MREIT imaging of the chest may deliver unique new diagnostic information.

Tc-99m hydroxymethylene diphosphonate scintigraphy, computed tomography, and magnetic resonance imaging of osteonecrosis in the mandible: Osteoradionecrosis versus medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki;Kameta, Ayako;Hayama, Kazuhide
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.53-58
    • /
    • 2019
  • Purpose: To present characteristic findings of Tc-99m hydroxymethylene diphosphonate (HMDP) scintigraphy, computed tomography (CT), and magnetic resonance (MR) imaging for osteonecrosis in the mandible, especially osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Thirteen patients with MRONJ and 7 patients with ORN in the mandible underwent Tc-99m HMDP scintigraphy, CT, and MR imaging (T1-weighted images[T1WI], T2-weighted images[T2WI], short inversion time inversion recovery images[STIR]), diffusion-weighted images[DWI], and apparent diffusion coefficient [ADC] mapping). The associations of scintigraphy, CT, and MR imaging findings with MRONJ and ORN were analyzed using the chi-square test with the Pearson exact test. Results: Thirteen patients with MRONJ and 7 patients with ORN in the mandible showed low signal intensity on T1WI and ADC mapping, high signal intensity on STIR and DWI, and increased uptake on scintigraphy. Periosteal bone proliferation on CT was observed in 69.2% of patients with MRONJ(9 of 13) versus 14.3% of patients with ORN(1 of 7)(P=0.019). Conclusion: This study presented characteristic imaging findings of MRONJ and ORN on scintigraphy, CT, and MR imaging. Our results suggest that CT can be effective for detecting MRONJ and ORN.

Hepatocellular carcinomas: correlation of enhancement degree with pathologic grades triple contrast MR imaging

  • Kim, Joo-Hee;Kim, Myeong-Jin;Park, Young-Nyun;Kim, Kyung-Sik;Lee, Woo-Jung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.108-108
    • /
    • 2001
  • Purpose: To correlate the histological differentiation of hepatocellular carcinomas (HCCs) with finding on triple contrast-enhanced MR imaging using gadolinium-chelates, superparamganetic ire oxides (SPIO), and mangafodipir trisodium. Method: Ten patients with proven HCC underwent triple contrast-enhanced MRI befo surgical resection. Subjective ratings of the enhancement pattern and degree were compare with the histological grades determined on surgical specimen. Quantitative measurements signal-to-noise ratio (S/N) of the lesion and the lesion-to-liver contrast-to-noise ratio C/N on the enhanced MR images, and the degree of S/N and C/N changes between the unenhanced and enhanced images were also correlated with the histological grades.

  • PDF