• 제목/요약/키워드: MR, experimental

검색결과 292건 처리시간 0.029초

자기장 및 유동 해석을 이용한 자기유변 클러치의 성능 예측 및 검증 (Design Analysis and Experimental Evaluation of an MR Fluid Clutch)

  • 이우섭;김태균;허남건;전도영
    • 대한기계학회논문집A
    • /
    • 제24권8호
    • /
    • pp.2143-2150
    • /
    • 2000
  • An MRC(Magneto-rheological Clutch) has a great potential of application because of its good transmissibility, little wear-out and fast response to electrical control signal. Though many MRCs have been developed for years, there has not been an research on the method to predict the performance of MRC except the simplified mathematical models. But the simplified mathematical models do not fit well since their performance has close relations with shapes of clutches and viscosity distribution throughout the fluids caused by applied magnetic fields. in this study, the CFD and FEM analyses were applied to various shape of MRC and the methods were examined in experiments.

Hyperpolarization: Sensitivity Boost in Magnetic Resonance Spectroscopy and Imaging

  • Ko, Hyeji;Gong, Gyeonghyeon;Jeong, Gijin;Choi, Ikjang;Seo, Hyeonglim;Lee, Youngbok
    • 한국자기공명학회논문지
    • /
    • 제19권3호
    • /
    • pp.124-131
    • /
    • 2015
  • Hyperpolarization methods are the most emerging techniques in the field of magnetic resonance (MR) researches since they make a contribution to overcoming sensitivity limitation of MR spectroscopy and imaging, leading to new fields of researches, real-time in vivo metabolic/molecular imaging and MR analysis of chemical/biological reactions in non-equilibrium conditions. Make use of enormous signal enrichments, it becomes feasible to investigate various chemical and biochemical systems with low ${\gamma}$ nuclei in real-time. This review deals with the theoretical principals of common hyperpolarization methods and their experimental features. In addition, more detailed theories, mechanisms, and applications of dissolution dynamic nuclear polarization (D-DNP) are discussed.

Magnetic Reactive Particle 코팅 및 인가전류에 따른 Magnetorheological Elastomer 의 전단계수 측정 (Experimental Evaluation on Shear Modulus of MRE due to MRP Coating and Induced Current)

  • 오재응;정운창;김진수;윤정민;노정준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.927-929
    • /
    • 2014
  • MRE(Magneto-rheological Elastomer) is a material which shows reversible and various modulus in magnetic field. Comparing to conventional rubber vibration isolator, MREs are able to absorb broader frequency range of vibration. These characteristic phenomena result from the orientation of magnetic particle (i.e., chain-like formation). Magnetic reactive powder(MRP), having rapid magnetic reaction, was selected as a magnetic particle to give magnetic field reactive modulus. The mechanical properties of manufactured MREs were measured with the application of magnetic field. The analysis of MR effect was carried out by FFT analyzer with various induced current. As induced magnetic field intensity increased and coated with MRP, increment of MR effect was observed.

  • PDF

MR DANTE 고속 영상에서 SNR의 개선에 관한 연구 (Improvement of SNR in DANTE Fast MR Imaging)

  • 정성택
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.87-96
    • /
    • 1997
  • A pixel profile in the conventional DANTE sequence is so poor that the excited area by DANTE sequence is a small portion of a pixel. This causes poor signal to noise ratio in DANTE image. In this paper, a frequency modulated(FM) DANTE imaging sequence is proposed to improve pixel profile in DANTE image. A DANTE pulse train is shaped by an FM function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on the sweep in FM signal. Computer simulations and experimental result obtained using a 7.0 T NMR imaging system are presented.

  • PDF

미세 진동 흡수를 위한 가변형 댐퍼 (The controllable damper for micro vibration suppression)

  • 김기덕;심원철;전도영;최범규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3289-3291
    • /
    • 1999
  • The vibration and impact hinders the movement of micro dynamic system. The controllable micro damper is a solution for this problem. In this paper, the controllable micro damper for MR(Magneto - Rheological) Fluid is designed and fabricated using bulk micromachining process and organic bonding technique. The damping constant of micro MR damper changes according to input magnetic field. The response of the micro MR damper is measured and the experimental results are compared.

  • PDF

A Variational Model For Longitudinal Brain Tissue Segmentation

  • Tang, Mingjun;Chen, Renwen;You, Zijuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권11호
    • /
    • pp.3479-3492
    • /
    • 2022
  • Longitudinal quantification of brain changes due to development, aging or disease plays an important role in the filed of personalized-medicine applications. However, due to the temporal variability in shape and different imaging equipment and parameters, estimating anatomical changes in longitudinal studies is significantly challenging. In this paper, a longitudinal Magnetic Resonance(MR) brain image segmentation algorithm proposed by combining intensity information and anisotropic smoothness term which contain a spatial smoothness constraint and longitudinal consistent constraint into a variational framework. The minimization of the proposed energy functional is strictly and effectively derived from a fast optimization algorithm. A large number of experimental results show that the proposed method can guarantee segmentation accuracy and longitudinal consistency in both simulated and real longitudinal MR brain images for analysis of anatomical changes over time.

실험적 모델을 이용한 자기공명영상에서 석회화의 인지 (The Detection of Intracranial Calcification by MR : Experimental Model)

  • 박승진
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.3-12
    • /
    • 1994
  • 연구목적 : 두개내 석회화 병변이 있을때 자기공명영상에서 석회화의 인지는 어렵다고 알려져 있으나 실험적 모델을 통하여 자기공명영상에서 석회화의 신호강도 양상을 알아보고자 하였다. 대상 및 방법 : 탄산칼슘(Calcium carbonate)과 수산화인회석(Hydroxyapatite) 공을 이용하여 일정한 농도(10, 20, 30 40, 50%) 및 크기 (l-10mm)에 따라 Gel형태의 Phantom으로 만들어 전산화단층촬영 및 MRI의 TI및 T2 강조영상을 얻어 각각 나타나는 소견과 ROI값을 비교분석하고 실제 석회화를 동반한 두개내 병변이 있었던 2예를 비교 관찰하였다. 결과 : 탄산칼슘은 농도가 증가함에 따라 T1과 T2 강조영상에서 저신호강도가 뚜렷하였으며, T1 강조영상에서 수산화인회석의 경우는 10, 20, 30%에서 가장 고신호강도를 나타냈으며 40, 50%로 농도가 증가할 수록 저신호강도로 역전되었다. 가성부갑상선 기능저하증 1예도 기저핵에서 T1강조영상상 고신호강도를 보였다. 결론 : MRI에서 석회화의 신호강도는 석회화의 성분, 농도, 크기에 따라 차이가 있고 특히 고신호강도를 보이는 경우 다른 질환과 감별에 유의하여야 할 것이다.

  • PDF

MR Damper의 Gap Size에 따른 제어성능 분석 (Analysis of Control Performance in Gap Size of MR Damper)

  • 허광희;전승곤;서상구;김대혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권1호
    • /
    • pp.41-50
    • /
    • 2021
  • 본 연구에서는 MR Damper의 제어력을 결정하는 다양한 요인들 중, 유로폭(Gap Size)을 다르게 선정하여 그에 따른 제어력의 변화를 확인하였다. 이를 위해 Gap Size 1.0mm, 1.5mm인 MR Damper 두 대를 제작하고 인가전류와 가진조건을 정하였으며 그에 따른 동하중 실험을 수행하였다. 실험결과 최소제어력은 Gap Size 1.0mm 조건이 Gap Size 1.5mm 조건보다 3.2배 높았으며 최대제어력은 Gap Size 1.0mm 조건이 Gap Size 1.5mm 조건보다 2.3배 높았다. 또한, 인가전류에 따른 제어력의 증가폭은 Gap Size 1.0mm일 때 34N, Gap Size 1.5mm일 때 12.7N으로 나타났다. Gap Size가 커질수록 전체 제어력과 인가전류에 따른 제어력의 증가는 감소하였다. 두 개의 MR Damper의 동적범위를 확인해 본 결과 Gap Size 1.0mm일 때 평균 2.3, Gap Size 1.5mm일 때 평균 2.8인 것을 볼 때 두 MR Damper의 준능동제어장치로써 사용가능성을 확인하였다.

Cz 실리콘 단결정에서 비대칭 자기장이 고액 계면에 미치는 영향 (Effect of asymmetric magnetic fields on the interface shape in Czochralski silicon crystals)

  • 홍영호;심광보
    • 한국결정성장학회지
    • /
    • 제18권4호
    • /
    • pp.140-145
    • /
    • 2008
  • Cz법을 이용하여 다양한 성장 조건하에서 실리콘 단결정이 성장되었따. 고액 계면 형상의 차이는 다양한 자기장 분포를 통하여 구현되었으며 결정의 고액 계면에 있어 ZGP(zero-Gauss plane) 형태와 자기장 세기(MI)의 효과가 실험적으로 연구되었따. ZGP의 형태는 커습 자기장에 있어 상부 및 하부 코일에 인가되는 자기장의 비율(MR)로 인하여 평평하거나 포물선의 형태를 갖게 된다. MR이 증가함에 따라 고액 계면은 더욱 음각(more concave)의 형태가 되고 이는 MR 증가에 따른 고액 계면으로의 뜨거운 융액이 쉽게 유입될 수 있음을 의미한다. 고액 계면의 효과적인 형상은 자기장 분포에 의존됨을 발견하였으며 실험결과는 다른 연구와 비교하였다.

MR 영상에서 중간형상정보 생성을 통한 활성형상모델 기반 반월상 연골 자동 분할 (Automatic Segmentation of the meniscus based on Active Shape Model in MR Images through Interpolated Shape Information)

  • 김민정;유지현;홍헬렌
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제16권11호
    • /
    • pp.1096-1100
    • /
    • 2010
  • 본 논문에서는 MR 영상에서 중간형상정보를 이용한 활성형상모델 기반의 반월상 연골 자동 분할 기법을 제안한다. 첫째, 훈련집합 내의 형상 변형을 반영하기 위해 반월상 연골 통계형상모델을 생성한다. 둘째, 큰 변형을 갖는 반월상 연골의 견고한 분할을 위해 유사도에 따른 가중치 기법을 이용하여 중간형상정보 생성 기법을 제안한다. 마지막으로 활성형상모탤 적합을 통해 반월상 연골 자동 분할을 수행한다. 제안 방법의 평가를 위하여 육안평가와 정확성 평가 그리고 수행시간을 측정하였다. 정확성 평가는 자동 분할과 반자동 분할 결과간의 평균거리차이를 측정하였고 이를 컬러맵으로 표현하였다. 실험 결과 평균거리차이는 내측 반월상 연골은 $0.54{\pm}0.16mm$, 외측 반월상 연골은 $0.73{\pm}0.39mm$으로 측정되었고, 수행시간은 평균 4.87초로 측정되었다.