• 제목/요약/키워드: MICA/B

검색결과 38건 처리시간 0.026초

수열합성법으로 제조한 흑색 자성안료의 Fe2+/Fe3+ 몰비에 따른 특성 (Effect of Fe2+/Fe3+ Molar Ratio on the Synthesized Magnetic Black Pigment by Hydrothermal Method)

  • 정명호;장건익
    • 한국전기전자재료학회논문지
    • /
    • 제30권12호
    • /
    • pp.812-816
    • /
    • 2017
  • $Fe_3O_4$ was prepared on the $TiO_2-coated$ natural mica substrate. The natural mica has an average particle size of $22{\mu}m$. The substrate was coated on $TiO_2$ thin films using hydrothermal synthesis at pH 1.5-2.5 at $75^{\circ}C$. The Fe precursor solution was prepared by mixing $FeSO_4$ (for $Fe^{2+}$ ion) and $FeCl_3$ (for $Fe^{3+}$ ions) with different molar ratios such as 1/2, 1/1, 2/1, 3/0, and $Fe_3O_4$ only. X-ray diffraction analysis shows that the crystal structure depends on the $FeCl_3-to-FeSO_4$ molar ratio. $Fe_3O_4$ crystal phase could be obtained at higher $FeSO_4$ contents.

Nano-TiO2를 이용한 자외선차단 마이카 복합체 제조 (Preparation of blocking ultraviolet mica composites using Nano-TiO2)

  • 윤기훈;이재복;문영진;고희경;이이;이동규
    • 한국응용과학기술학회지
    • /
    • 제35권4호
    • /
    • pp.1197-1205
    • /
    • 2018
  • 자외선차단 화장품은 기능성 화장품 중의 하나로서, 유 무기 자외선차단물질이 함유되어 있다. 무기계 자외선차단제는 주로 산화아연, 이산화티탄 등이 있다. 무기계 자외선차단제는 입자의 지름이 60 ~ 100 nm로 자외선 A, B의 차단능이 좋은 것으로 알려져 있다. 또한자외선을 포함한 태양광선에 대해 비활성이 크고 안전성이 우수하다. 그리고 유기계 자외선차단제처럼 피부에 흡수 또는 축적되지 않으므로 피부자극이나 알레르기를 유발하지 않는다. 본 연구에서는 판상 무기안료인 마이카, 자외선차단 효과를 갖는 이산화티탄 나노입자, 소수성 실리카를 각각 계면활성제로 표면처리 하였고, 각 물질의 전하 차이에 따른 비화학적인 상호 인력 작용에 의해 마이카에 이산화티탄 나노입자, 실리카를 물리적으로 흡착시켰다. 이후, 소수성 표면처리제인 실란을 표면처리 하여 소수성을 갖는 자외선 차단 판상 마이카 복합체를 제조하였다. 자외선 차단 판상 마이카 복합체는 일반적인 나노입자 이산화티탄의 응집성을 개선하고 균일한 분산에 따른 자외선차단 효과가 증대되었으며, 소수성으로 표면처리를 하여 화장품 제형에서의 분산안정성을 크게 개선할 수 있었다. 안료의 표면전하는 제타전위로 평가하였으며, 제조된 자외선차단 마이카 복합체의 특성 평가는 FE-SEM, XRD, FT-IR, UV-VIS 등으로 확인하였다.

고압전동기 고정자 권선의 운전중 부분방전 분석 (Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings)

  • 이상길;김희동;김광헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.152-155
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

고압전동기 고정자 권선의 운전중 부분방전 분석 (Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings)

  • 이상길;김희동;김광헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.199-202
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected. PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

PbTe/CdTe(111)B와 마이카 기판 위에 성장된 Bi 박막의 후열처리 전후의 자기저항 (Magnetoresistance in Post-annealed Bi Thin Films on PbTe-buffered CdTe(111)B and on Mica Substrates)

  • 김윤기;최진성;이해파;조성래
    • 한국진공학회지
    • /
    • 제15권4호
    • /
    • pp.367-373
    • /
    • 2006
  • 비스무스의 녹는점보다 3 도 낮은 온도인 $268^{\circ}C$에서 후열처리를 하여 비스무스 박막에서 자기저항의 큰 증가를 관측하였다. 레드텔러라이드 / 케드뮴텔러라이드 기판 위에서는 온도 5 K, 자기장 5T 하에서 190 에서 260으로, 마이카 기판 위에서는 620 에서 120 으로 자기저항의 큰 증가를 나타내었다. 이러한 자기저항의 큰 증가는, 열처리에 따른 결정도의 향상에 기인한 것으로 보인다. 하지만 일정 시간 이상의 오랜 시간의 열처리는 자기저항을 감소시키는 것으로 관측되었다.

가스터빈 발전기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in Gas Turbine Generator Stator Windings)

  • 김희동;양규현;주영호
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1423-1428
    • /
    • 2010
  • The results of off-line and on-line diagnostic tests performed on the stator winding of an air-cooled gas turbine(G/T) generator are reported in this paper. Off-line diagnostic tests included measurements of the ac current, dissipation factor(tan${\delta}$), and partial discharge(PD). Six epoxy-mica capacitors were installed in the three phases of G/T generator for performing on-line diagnostic testing with the turbine generator analyzer(TGA). The TGA showed that the normalized quantity number(NQN) and the PD magnitude($Q_m$) were high in phase A of the stator winding. Internal discharges were generated in phases B and C, and slot discharge occurred in phase A. According to the trend analyses of the NQN and $Q_m$ values available for insulation condition assessment for G/T generator stator windings, it was concluded that phases B and C were in good condition, whereas phase A has been significantly deteriorated.

공랭식 가스터빈 발전기의 운전중 부분방전 분석 (Analysis of On-Line Partial Discharge in Air-Coolded Gas Turbine Generator)

  • 이은춘;공태식;김재철;김희동
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.41-47
    • /
    • 2014
  • The on-line partial discharge (PD) in stator windings of air-cooled gas turbine (GT) generator (119.2MVA, 13.8kV) is measured and analyzed in this paper. This generator was designed by global vacuum pressure impregnation (VPI). The generator failed two times at top bar (16T) of phase B in the stator slot. Six epoxy-mica capacitors were installed in three phases of GT generator. On-line PD test was performed on GT generator using turbine generator analyzer (TGA). TGA showed that the normalized quantity number (NQN) and the PD magnitude($Q_m$) were high in phase B. Internal discharges were generated in phases A, B and C. The trend analysis of NQN and $Q_m$ value are obtained in order to monitor the insulation condition in GT generator stator windings. Phases A and C were in good condition. But phase B had deteriorated significantly

대규모 무선 센서 네트워크에서 노드 분포를 고려한 분산 위치 인식 기법 및 구현 (Node Distribution-Based Localization for Large-scale Wireless Sensor Networks)

  • 한상진;이성진;이상훈;박종준;박상준
    • 한국통신학회논문지
    • /
    • 제33권9B호
    • /
    • pp.832-844
    • /
    • 2008
  • 대규모 센서 네트워크를 위한 분산 위치 인식 기법은 센서 네트워크의 운용에 있어서 반드시 필요한 기술이다. 센서가 획득한 데이터에 대한 지형적인 위치를 결정함으로써 그 데이터에 대한 가치가 중요해질 수도 그렇지 않을 수도 있기 때문이다. 본 논문에서는 초소형, 저가의 센서가 비교적 많은 수로 분포되어 있고 또한 그 분포 특성이 대부분 균일할 때 기존에 사용되어 오던 삼각법보다는 정확하고 최근에 제안된 MDS를 이용한 기법 보다는 간단하고 효율적인 분산 위치 인식 기법에 대해서 소개한다. 이는 노드의 분포 특성을 이용함으로써 삼각법과 같은 매우 간단한 기법보다는 보다 정확하고 많은 계산을 요구하여 시스템의 실용성에는 적합하지 않은 MDS보다는 보다 간단한 위치인식을 수행한다. 이는 MATLAB을 이용한 PC 실험에서 제안하는 기법의 성능을 검증하고 Crossbow사의 micaZ 모트에 TinyOS-2.x를 이용하여 제안하는 위치인식 기술을 구현함으로써 그 실용성을 입증하였다.

Ferromagnetic Resonance Observation of Martensitic Phase Transformation in Ni-Mn-Ga Ferromagnetic Shape Memory Films

  • Dubowik, J.;Kudryavtsev, Y.V.;Lee, Y.P
    • Journal of Magnetics
    • /
    • 제9권2호
    • /
    • pp.37-39
    • /
    • 2004
  • Polycrystalline Ni-Mn-Ga films have been deposited onto mica substrates held at 720 K by flash-evaporation method. At room temperature the films have a tetragonal structure with a = b = 0.598 and c = 0.576 nm typical for bulk $Ni_2MnGa$ below a martensitic transformation. Temperature measurements of ferromagnetic resonance reveal a martensitic phase transformation at 310 K. The transformation brings about a substantial decrease in the effective magnetization and a drastic increase in the ferromagnetic resonance linewidth due to a strong increase in the magnetic anisotropy in the martensitic phase.

발전기 고정자 권선의 새로운 절연열화 판정기준 설정에 관한 연구 (A Study on the New Criteria for Assessing the Insulation Deterioration of Generator Stator Winding)

  • 황돈하;김용주;김진봉;전정우;김희곤;박종정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1692-1695
    • /
    • 1997
  • This paper describes the relationship between the various non-destructive parameters and the breakdown voltage for the 17 kV, 300 MVA and the 22 kV, 500 MVA generators stator bars with polyester and epoxy/mica insulation respectively. Also, this study reports the results of an investigation into the factors which can assess the insulation condition of generator stator winding. Furthermore, a new parameter, Partial Discharge Index(PDI), is introduced as the valuable parameter for the assessment of insulation condition. The ratio between partial discharge increment and the stepwise voltage increment from the Discharge Inception Voltage (DIV) at the characteristic or resonant frequency band shows the close relationship between the breakdown voltage and PDI.

  • PDF