• Title/Summary/Keyword: MIC(Module Integrated Converter)

Search Result 24, Processing Time 0.029 seconds

MIC with Ripple Voltage Compensator Using Regenerative Snubber (에너지 회생형 스너브를 이용한 리플 전압 억제기를 가지는 MIC(Module Integrated Converter))

  • Kim, Hong-Sung;Chang, Hun Ki;Yoon, Yeo Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.75-76
    • /
    • 2014
  • This study deals with a isolation type MIC(Module Integrated Converter) for AC module with advantages such as DC Wireless, freely selectable installation capacity, minimized shadow effect etc. In this paper, MIC circuit with the function which can remove the ripple voltage of PV module and give the discharging path for charged energy in leakage inductance of isolation transformer. The validity of proposed circuir is verified by the simulation with PSIM.

  • PDF

Loss Analysis according to Configuration Method of AC Module Integrated Converter for Photovoltaic System (태양광 발전 시스템용 AC 모듈 집적형 전력변환기의 구성 방식에 따른 손실 분석)

  • Kang, Seung-Hyun;Son, Won-Jin;Ann, Sangjoon;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.311-318
    • /
    • 2020
  • A photovoltaic (PV) system uses an AC module integrated converter (MIC) to operate PV cells at a maximum power point (MPP) and for high efficiency. The MPP of a PV cell varies depending on partial shading conditions, and loss occurs differently according to the configuration method of the PV-MIC. Therefore, this study compares the losses of passive components and power semiconductors according to the partial shading conditions of the PV module. Theoretical loss analysis is performed using parameters for the datasheet and PSIM simulation results. Analysis results verify that the one-stage PV-MIC demonstrates high efficiency.

Study On Photovoltaic Module Integrated Converter based on Active Clamp Current-fed Half-Bridge Converter (능동 클램프 전류원 하프 브릿지 기반 태양광 모듈 집적형 전력변환장치에 대한 연구)

  • Jung, Hoon-Young;Park, Jeong-Kyu;Ji, Young-Hyok;Won, Chung-Yuen;Lee, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.105-113
    • /
    • 2011
  • In this paper, photovoltaic module integrated converter (MIC) based on active clamp current-fed half-bridge converter is proposed. The converter stage operates in zero-voltage condition using active clamp technique. The theoretical study and circuit design for proposed inverter are confirmed with PSIM simulator and experimental reusult.

High-efficiency 400W Module Integrated Converter for PV applications (고효율 400W급 태양광 Module Integrated Converter 개발)

  • Lee, Sung-Ho;Kim, Soo-A;Kim, Min-Sung;Goo, Tae-Hong;Kim, Soo-Hong;Choi, Jung-Hwan;Huh, Dong-Young;Kwon, Bong-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.289-290
    • /
    • 2015
  • 본 논문에서는 고효율, 저가격의 400W급 태양광 Module Integrated Converter (MIC)를 소개한다. 제안하는 MIC는 Interleaved flyback 토폴로지를 기반으로, 계통 주기 내에서 DCM과 CCM의 모든 동작 영역을 활용할 수 있게 설계되어 도통 손실 및 전력 용량을 개선한다. 또한 새로운 출력 제어 전류 알고리즘을 통해 기존의 Flyback의 CCM 영역에서의 제어문제를 해결하여 개발된 Flyback MIC의 실효성을 획득한다. 최종적으로 400W급 시제품을 제작하여 타당성 검증 및 결과를 제시한다.

  • PDF

A Study on Core Structure of High Frequency Transformer to Improve Efficiency of Module-Integrated Converter

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.295-299
    • /
    • 2014
  • Recently, module-integrated converter (MIC) research has shown interest in small-scale photovoltaic (PV) generation. The converter is capable of efficient power generation. In this system, the high frequency transformer should be made compact, and demonstrate high efficiency characteristics. This paper presents a core structure optimization procedure to improve the efficiency of a high frequency transformer of compact size. The converter circuit is considered in the finite element analysis (FEA) model, in order to obtain an accurate FEA result. The results are verified by the testing of prototypes.

Analysis and Realization of Control Sequence of Photovoltaic Module Integrated Converter (태양광 모듈 집적형 전력변환장치의 제어 시퀀스의 분석 및 구현)

  • Lee, Eun-Ju;Kim, Dong-Hee;Lee, Byoung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.93-94
    • /
    • 2012
  • 본 논문에서는 태양광 모듈 집적형 전력변환장치 (Photovoltaic Module Integrated Converter, PV MIC)를 구동하기 위한 제어 시퀀스를 분석하고 이를 구현한다. 이를 위해 Cascade Buck-Boost Converter Topology를 채택하였고, 이를 기반으로 일사조건에 따른 최대 전력점 추종을 위해 PV MIC의 동작 모드를 결정하는 제어 시퀀스를 제안한다. 실제 PV Module을 연결한 PV MIC의 구동 실험을 통하여 제안한 제어 시퀀스를 검증한다.

  • PDF

Digitally Controlled Interleaving Tapped-Inductor Boost Converter for Photovoltaic Module Integrated Converters (PV MIC)

  • Lee, Jye-June;Kim, Jitae;Bae, Hyunsu;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.74-75
    • /
    • 2010
  • As global warming due to burning fossil fuels and natural resource depletion issues have emerged, the development of renewable energy sources such as photovoltaics (PV) has been brought to recent interest. Amongst the vast efforts to harvest and convert solar energy into electricity, the module integrated converters (MIC) has become a worthy topic of research for grid-connected photovoltaic systems. Due to the required high-boosting qualities, only a restricted amount of DC/DC converter topologies can be applied to MICs. This paper investigates the possibility of a tapped-inductor boost converter as a candidate for PV MICs. A dual-inductor interleaving scheme operating slightly above the boundary of the two conduction modes (BCM) is suggested for reduction of input current ripple and minimization of component stress. A digital controller is used for implementation, assuring maximum power tracking and transfer while providing sufficient computational space for other grid connectivity applications, etc. For verification, a 200W converter is designed and simulated via computer software including component losses. High efficiency over a wide power range proves the feasibility of the proposed PV MIC system.

  • PDF

A Novel Active Clamp Switching Method To Improve of Efficiency For Photovoltaic MIC (태양광 MIC 시스템의 효율향상을 위한 새로운 Active Clamp 스위칭 기법)

  • Park, Byung-Chul;Park, Ji-Ho;Song, Sung-Geun;Park, Sung-Jun;Shin, Joong-Rin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.477-484
    • /
    • 2013
  • This paper proposes a novel switching method of active clamp snubber for efficiency improvement of PV module integrated converter(MIC) system. Recently, MIC solar system is researched about the efficiency and safety. PV MIC system is used active clamp method of snubber circuit for the price and reliability of the system. But active clamp snubber circuit has the disadvantage that system efficiency is decreased for switch operating time because of heat loss of resonant between snubber capacitor and leakage inductance. To solve this problem, this paper proposes a novel switching method of the active clamp. The proposed method is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time and through simulations and experiments proved the validity.

A New Controllable Active Clamp Algorithm for Switching Loss Reduction in a Module Integrated Converter System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.465-471
    • /
    • 2014
  • This paper proposes a new switching algorithm for an active clamp snubber to improve the efficiency of a module integrated converter system. This system uses an active clamp method for the snubber circuit for the efficiency and reliability of the system. However, the active clamp snubber circuit has the disadvantage that system efficiency is decreased by switch operating time because of heat loss in resonance between the snubber capacitor and leakage inductance. To address this, this paper proposes a new switching algorithm. The proposed algorithm is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time. Also, the snubber switch is operated at zero voltage switching by turning on the snubber switch before main switch turn-off. Simulation and experimental results are presented to show the validity of the proposed new active clamp control algorithm.

Loss Analysis according to Configuration Method of AC Module Integrated Converter for Photovoltaic System (태양광 발전 시스템용 AC 모듈 집적형 전력변환기의 구성 방식에 따른 손실 분석)

  • Kang, Sunghyun;Son, Won-Jin;Ann, Sangjoon;Lee, Byoung Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.172-173
    • /
    • 2019
  • 본 논문은 태양광(photovoltaic, PV) 발전 시스템용 AC 모듈형 집적형 전력변환기(module Integrated converter, MIC)의 구성 방식에 따른 전력 손실을 비교·분석한다. 대표적으로 사용되는 플라이백 컨버터를 기반으로 하는 1-stage와 2-stage 구조의 AC 모듈형 PV-MIC를 비교하고, PSIM 시뮬레이션과 수식을 이용하여 전력 손실을 계산한다.