• Title/Summary/Keyword: MATHCAD

Search Result 17, Processing Time 0.025 seconds

Mathcad program as a useful tool for the teaching and studying the sport biomechanics (운동역학의 교육과 연구용 도구로서 Mathcad의 유용성)

  • Sung, Rak-Joon
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.301-311
    • /
    • 2004
  • The purpose of this study was to verify the usefulness of the Mathcad program as a tool for the studying and teaching the sport biomechanics. A projectile motion was analyzed because it is the one of the most popular motion in sports activities. A 3 dimensional CG data for the high jump bar clear phase was used to calculate the initial velocity vector of the CG. Linear regression function and other functions such as cubic spline and derivative of Mathcad were used to calculate this vector. Finally, the approach angle to the bar and peak jump height was calculated. Programming in Mathcad was relatively easy compare to traditional computer language such as Fortran and C, because of the unique documentation method of Mathcad. Additionally the 2 and 3 dimensional graph function was very easy and useful to describe the mechanical data. If the use of Mathcad program is more popular in the field of sport biomechanics, it could greatly contribute to overcome the limit of research caused by the lack of proper programming ability.

Mathcad를 이용한 전력전자 회로 Simulation

  • Kim, Dae-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.100-102
    • /
    • 2003
  • 이 study는 수치 계산 및 수치 해석 프로그램으로 폭넓게 사용되는 Mathcad를 이용하여 전기/전자/전력 회로를 수학적인 모델링으로 구현하여 다양한 분석법으로 해를 구하는 내용을 보여준다.

  • PDF

A Study on the Fault Location Algorithms on Transmission Line (송전선로의 고장점 검출방법에 관한 연구)

  • Song, Myoung-Gon;Oh, Yong-Taek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.36-41
    • /
    • 2014
  • Most faults that occur on transmission lines are caused by extreme weather with lightning storms in the distance. These are not only prolongs the time of removing and recovering, but also increases economical damages. If faults can be precisely located, maintenance crews can reach them quickly, and remove the faults in time. So, the precise locating of the faulted point on a transmission line is very important to improve the system reliability, and decreases economic damages as an inherent consequence of long term outages. Also, fault location methods are becoming of much importance for utilities and research. In this paper, two single-terminal impedance-based fault location techniques will be investigated to show the reliability and evaluated the performance of reactance and Takagi method by using MATHCAD program simulations.

A NUMERICAL METHOD FOR SOLVING THE FREDHOLM INTEGRAL EQUATION OF THE SECOND KIND

  • Sridharan, V.;Jayashree, P.R.
    • Journal of applied mathematics & informatics
    • /
    • v.5 no.2
    • /
    • pp.293-300
    • /
    • 1998
  • The numerical method is used to solve the Fredholm integral equation of the second kind with weak singular kernels using the Toeplitz matrices. The solution has a computing time requir-ment of O(N2) where 2N+1 is the number of discretization points used. Also the error estimate is computed. Some numerical Exam-ples are computed using the Mathcad package.

DC/DC Switching Converter Characteristics (DC/DC 스위칭 컨버터 특성)

  • 최영진;김상준;김태경
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.743-746
    • /
    • 1999
  • In this paper, Flyback type DC/DC Switching Converter was designed, analyzed and fabricated. Worst Case Analysis(WCA) was peformed with Mathcad program and presents circuit simulation results for the in-rush current limit circuit. The value of the maximum OFF voltage stress is 131.84V, it is less than device specification(200V). The switching frequency(nominal case) and duty cycle at the wont case analysis are 75KHz and 34.62%, respectively. The maximum in-rush current presents 0.5A Those results show a possibility for use in space

  • PDF

Surface profile measurement with FFT method and stabilized interferometer (안정화된 간섭계와 FFT를 이용한 표면 측정)

  • 류진;김현수;박종락;김진태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.269-273
    • /
    • 2004
  • The moduled interferometer with waveplates, polarizing beam splitter, etc. for four phase shifted interference patterns was stabilized with the and Fast Fourier Transform (FFT) method was used to investigate the surface profile measurement from the interferenece pattern from Twyman-Green interferometer using a mathcad.

  • PDF

A Study of the Quantitative Relationship of Charge-Density Changes and the Design Area of a Fabricated Solar Cell

  • Jeon, Kyeong-Nam;Kim, Seon-Hun;Kim, Hoy-Jin;Kim, In-Sung;Kim, Sang-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.5
    • /
    • pp.204-208
    • /
    • 2011
  • In this paper, the design area of a fabricated solar cell has been analyzed with respect to its charge density. The mathematical calculation used for charge-density derivation was obtained from the 2001 version of a MATHCAD program. The parameter range for the calculations was ${\pm}1{\times}10^{17}cm^{-3}$, which is in the normal parameter range for n-type doping impurities ($7.0{\times}10^{17}cm^{-3}$) and also for p-type impurities ($4.0{\times}10^{17}cm^{-3}$). Therefore, it can be said that the fabricated solar-cell design area has a direct effect on charge-density changes.

Theoretical Analysis of the Slipper Hydrostatic Bearing Shape in the Swash Plate Type Axial Piston Pump (사판식 유압 피스톤 펌프의 슬리퍼 정압베어링면 형상에 관한 이론해석)

  • Cho, I.S.
    • Journal of Drive and Control
    • /
    • v.10 no.1
    • /
    • pp.14-20
    • /
    • 2013
  • In the high rotational speed and pressure state, the leakage flow rate of the axial piston pump is one of the serious problems and make great reasons to decrease the volume efficiency. In this study, tribology characteristics is clarified for the hydrostatic slipper bearing in the swash plate type axial piston pump, by means of theoretical analysis for the different shape of the hydrostatic slipper bearing. It was analyzed by Mathcad software and used equal conditions at $0^{\circ}$ swash plate angle in each model. The results show that performance characteristics of the swash plate type axial piston pump are significantly influenced by the shape of the hydrostatic slipper bearing.

NiH2 battery voltage limit circuit design for satellite (인공위성용 니켈-수소 축전지 충전전압 제한회로 구현)

  • Choi, Young-Jin;Wang, Jin-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.376-378
    • /
    • 1995
  • A voltage-temperature limit circuit for the Ni-H2 battery is designed and analyzed for the maximum and the minimum voltage deviations at the worst case of the EOL(end of life). It is demonstrated that the magnitude of voltage deviations due to circuit device tolerances are kept less than 0.3v at the worst case. The maximum and the minimum battery voltages are simulated for the environmental temperature range of $0^{\circ}C-30^{\circ}C$ by using MATHCAD. They are 34.67v and 29.851v, respectively.

  • PDF