• Title/Summary/Keyword: MANAGEMENT MODEL

Search Result 22,457, Processing Time 0.05 seconds

Analysis of Transfer Rate on Listeria monocytogenes Contaminated Pork Meat During Processing (돈육 가공공정 중 돈육에 오염된 Listeria monocytogenes의 전이율 분석)

  • Kim, Seong-Jo;Kim, Gwang-Hee;Park, Joong-Hyun;Park, Bo-Geum;Park, Myoung-Su;Oh, Deog-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.432-441
    • /
    • 2012
  • In this study, the transfer rate of wild type Listeria mon, ytogenes (LM) was investigated to establish the standard of safety management during pork meat pr, essing for meat to meat and meat to food contact surfaces contamination at 5 and $10^{\circ}C$. The transfer rate of LM from meat to meat during the pr, essing increased from 0.02% after 30 min to 0.42% after 120 min at $5^{\circ}C$, while for conveyor belt and stainless steel, it decreased from 0.015% and 0.013% after 30 min to 0.002% and 0.0003% after 120 min at $5^{\circ}C$, respectively (p < 0.05). When temperature increased to $10^{\circ}C$, the transfer rates of LM from meat to meat, conveyor belt and stainless steel were the highest at 60 min exposure, and all decreased after 120 min. In reverse, the transfer rate from food contact surface to pork meat was significantly higher than that from pork meat to food contact surface (p < 0.01). Also, the transfer rate to conveyor belt was significantly higher than stainless steel (p < 0.05) and it was highest at 30 min exposure time in both 5 and $10^{\circ}C$. This study indicates that the transfer and adherence rates of LM are influenced by the contact time and temperature. Consequently, these results were utilized to develop a predictive model with a high level of confidence which can lead to prevent cross-contamination during pork meat processing.

Risk Ranking Analysis for the City-Gas Pipelines in the Underground Laying Facilities (지하매설물 중 도시가스 지하배관에 대한 위험성 서열화 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.54-66
    • /
    • 2004
  • In this article, we are to suggest the hazard-assessing method for the underground pipelines, and find out the pipeline-maintenance schemes of high efficiency in cost. Three kinds of methods are applied in order to refer to the approaching methods of listing the hazards for the underground pipelines: the first is RBI(Risk Based Inspection), which firstly assess the effect of the neighboring population, the dimension, thickness of pipe, and working time. It enables us to estimate quantitatively the risk exposure. The second is the scoring system which is based on the environmental factors of the buried pipelines. Last we quantify the frequency of the releases using the present THOMAS' theory. In this work, as a result of assessing the hazard of it using SPC scheme, the hazard score related to how the gas pipelines erodes indicate the numbers from 30 to 70, which means that the assessing criteria define well the relative hazards of actual pipelines. Therefore. even if one pipeline region is relatively low score, it can have the high frequency of leakage due to its longer length. The acceptable limit of the release frequency of pipeline shows 2.50E-2 to 1.00E-l/yr, from which we must take the appropriate actions to have the consequence to be less than the acceptable region. The prediction of total frequency using regression analysis shows the limit operating time of pipeline is the range of 11 to 13 years, which is well consistent with that of the actual pipeline. Concludingly, the hazard-listing scheme suggested in this research will be very effectively applied to maintaining the underground pipelines.

Investigation and Analysis of Hazards for Cultivation Environment to Establish the Good Agricultural Practices(GAP) of Soybean (콩 GAP 모델 확립을 위한 재배환경의 위해요소 조사 및 분석)

  • Kim, Kyeong-Yeol;Song, Jeong-Eon;Heo, Rok-Won;Lee, Won-Gyeong;Nam, Min-Ji;Kim, Jeong-Sook;Shim, Won-Bo;Gil, Jung-Gwon;Jung, Chan-Sik;Park, Keum-Yong;Chung, Duck-Hwa
    • Journal of agriculture & life science
    • /
    • v.44 no.6
    • /
    • pp.121-132
    • /
    • 2010
  • Soybean farms in Changnyeong were selected for hazard analysis to establish the Good Agricultural Practices (GAP) model of soybean, and physical, chemical(heavy metal) and biological(sanitary indications, foodborne pathogens) hazard analysis for cultivation environment (soil, water) was carried out. First, bow which is able to be mixed in soil and water was confirmed as physical hazard. Levels (Cd:0.01~0.103, Cu:0.001~6.036, As:0.006~3.045, Hg:ND~0.041, Pb:0.003~3.952, $Cr^{+6}$:0.007~0.496, Zn:0.001~66.500, Ni:0.003~18.010) of heavy metals in soil and water were appropriate for GAP criteria. In biological hazard, APC and coliform in soil were detected at the levels of $6.0{\pm}0.3$ and $3.6{\pm}1.6$ log CFU/g, and levels of water were $3.5{\pm}0.7$ and $1.9{\pm}0.7$ log CFU/mL, while E. coli wasn't detected in all sample. However, coliform in water wasn't appropriate for criteria, and E. coli O157 was detected about 22% in some farms, so it needs ways to prevent contamination by human and animals excrements. In conclusion, it needs proper management to prevent cross-contamination of hazards although physical and chemical hazard level were appropriate for GAP criteria while biological hazard wasn't.

How effective has the Wairau River erodible embankment been in removing sediment from the Lower Wairau River?

  • Kyle, Christensen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.237-237
    • /
    • 2015
  • The district of Marlborough has had more than its share of river management projects over the past 150 years, each one uniquely affecting the geomorphology and flood hazard of the Wairau Plains. A major early project was to block the Opawa distributary channel at Conders Bend. The Opawa distributary channel took a third and more of Wairau River floodwaters and was a major increasing threat to Blenheim. The blocking of the Opawa required the Wairau and Lower Wairau rivers to carry greater flood flows more often. Consequently the Lower Wairau River was breaking out of its stopbanks approximately every seven years. The idea of diverting flood waters at Tuamarina by providing a direct diversion to the sea through the beach ridges was conceptualised back around the 1920s however, limits on resources and machinery meant the mission of excavating this diversion didn't become feasible until the 1960s. In 1964 a 10 m wide pilot channel was cut from the sea to Tuamarina with an initial capacity of $700m^3/s$. It was expected that floods would eventually scour this 'Wairau Diversion' to its design channel width of 150 m. This did take many more years than initially thought but after approximately 50 years with a little mechanical assistance the Wairau Diversion reached an adequate capacity. Using the power of the river to erode the channel out to its design width and depth was a brilliant idea that saved many thousands of dollars in construction costs and it is somewhat ironic that it is that very same concept that is now being used to deal with the aggradation problem that the Wairau Diversion has caused. The introduction of the Wairau Diversion did provide some flood relief to the lower reaches of the river but unfortunately as the Diversion channel was eroding and enlarging the Lower Wairau River was aggrading and reducing in capacity due to its inability to pass its sediment load with reduced flood flows. It is estimated that approximately $2,000,000m^3$ of sediment was deposited on the bed of the Lower Wairau River in the time between the Diversion's introduction in 1964 and 2010, raising the Lower Wairau's bed upwards of 1.5m in some locations. A numerical morphological model (MIKE-11 ST) was used to assess a number of options which led to the decision and resource consent to construct an erodible (fuse plug) bank at the head of the Wairau Diversion to divert more frequent scouring-flows ($+400m^3/s$)down the Lower Wairau River. Full control gates were ruled out on the grounds of expense. The initial construction of the erodible bank followed in late 2009 with the bank's level at the fuse location set to overtop and begin washing out at a combined Wairau flow of $1,400m^3/s$ which avoids berm flooding in the Lower Wairau. In the three years since the erodible bank was first constructed the Wairau River has sustained 14 events with recorded flows at Tuamarina above $1,000m^3/s$ and three of events in excess of $2,500m^3/s$. These freshes and floods have resulted in washout and rebuild of the erodible bank eight times with a combined rebuild expenditure of $80,000. Marlborough District Council's Rivers & Drainage Department maintains a regular monitoring program for the bed of the Lower Wairau River, which consists of recurrently surveying a series of standard cross sections and estimating the mean bed level (MBL) at each section as well as an overall MBL change over time. A survey was carried out just prior to the installation of the erodible bank and another survey was carried out earlier this year. The results from this latest survey show for the first time since construction of the Wairau Diversion the Lower Wairau River is enlarging. It is estimated that the entire bed of the Lower Wairau has eroded down by an overall average of 60 mm since the introduction of the erodible bank which equates to a total volume of $260,000m^3$. At a cost of $$0.30/m^3$ this represents excellent value compared to mechanical dredging which would likely be in excess of $$10/m^3$. This confirms that the idea of using the river to enlarge the channel is again working for the Wairau River system and that in time nature's "excavator" will provide a channel capacity that will continue to meet design requirements.

  • PDF

Optimization Process Models of Gas Combined Cycle CHP Using Renewable Energy Hybrid System in Industrial Complex (산업단지 내 CHP Hybrid System 최적화 모델에 관한 연구)

  • Oh, Kwang Min;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.65-79
    • /
    • 2019
  • The study attempted to estimate the optimal facility capacity by combining renewable energy sources that can be connected with gas CHP in industrial complexes. In particular, we reviewed industrial complexes subject to energy use plan from 2013 to 2016. Although the regional designation was excluded, Sejong industrial complex, which has a fuel usage of 38 thousand TOE annually and a high heat density of $92.6Gcal/km^2{\cdot}h$, was selected for research. And we analyzed the optimal operation model of CHP Hybrid System linking fuel cell and photovoltaic power generation using HOMER Pro, a renewable energy hybrid system economic analysis program. In addition, in order to improve the reliability of the research by analyzing not only the heat demand but also the heat demand patterns for the dominant sectors in the thermal energy, the main supply energy source of CHP, the economic benefits were added to compare the relative benefits. As a result, the total indirect heat demand of Sejong industrial complex under construction was 378,282 Gcal per year, of which paper industry accounted for 77.7%, which is 293,754 Gcal per year. For the entire industrial complex indirect heat demand, a single CHP has an optimal capacity of 30,000 kW. In this case, CHP shares 275,707 Gcal and 72.8% of heat production, while peak load boiler PLB shares 103,240 Gcal and 27.2%. In the CHP, fuel cell, and photovoltaic combinations, the optimum capacity is 30,000 kW, 5,000 kW, and 1,980 kW, respectively. At this time, CHP shared 275,940 Gcal, 72.8%, fuel cell 12,390 Gcal, 3.3%, and PLB 90,620 Gcal, 23.9%. The CHP capacity was not reduced because an uneconomical alternative was found that required excessive operation of the PLB for insufficient heat production resulting from the CHP capacity reduction. On the other hand, in terms of indirect heat demand for the paper industry, which is the dominant industry, the optimal capacity of CHP, fuel cell, and photovoltaic combination is 25,000 kW, 5,000 kW, and 2,000 kW. The heat production was analyzed to be CHP 225,053 Gcal, 76.5%, fuel cell 11,215 Gcal, 3.8%, PLB 58,012 Gcal, 19.7%. However, the economic analysis results of the current electricity market and gas market confirm that the return on investment is impossible. However, we confirmed that the CHP Hybrid System, which combines CHP, fuel cell, and solar power, can improve management conditions of about KRW 9.3 billion annually for a single CHP system.

Long-term forecasting reference evapotranspiration using statistically predicted temperature information (통계적 기온예측정보를 활용한 기준증발산량 장기예측)

  • Kim, Chul-Gyum;Lee, Jeongwoo;Lee, Jeong Eun;Kim, Hyeonjun
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.12
    • /
    • pp.1243-1254
    • /
    • 2021
  • For water resources operation or agricultural water management, it is important to accurately predict evapotranspiration for a long-term future over a seasonal or monthly basis. In this study, reference evapotranspiration forecast (up to 12 months in advance) was performed using statistically predicted monthly temperatures and temperature-based Hamon method for the Han River basin. First, the daily maximum and minimum temperature data for 15 meterological stations in the basin were derived by spatial-temporal downscaling the monthly temperature forecasts. The results of goodness-of-fit test for the downscaled temperature data at each site showed that the percent bias (PBIAS) ranged from 1.3 to 6.9%, the ratio of the root mean square error to the standard deviation of the observations (RSR) ranged from 0.22 to 0.27, the Nash-Sutcliffe efficiency (NSE) ranged from 0.93 to 0.95, and the Pearson correlation coefficient (r) ranged from 0.97 to 0.98 for the monthly average daily maximum temperature. And for the monthly average daily minimum temperature, PBIAS was 7.8 to 44.7%, RSR was 0.21 to 0.25, NSE was 0.94 to 0.96, and r was 0.98 to 0.99. The difference by site was not large, and the downscaled results were similar to the observations. In the results of comparing the forecasted reference evapotranspiration calculated using the downscaled data with the observed values for the entire region, PBIAS was 2.2 to 5.4%, RSR was 0.21 to 0.28, NSE was 0.92 to 0.96, and r was 0.96 to 0.98, indicating a very high fit. Due to the characteristics of the statistical models and uncertainty in the downscaling process, the predicted reference evapotranspiration may slightly deviate from the observed value in some periods when temperatures completely different from the past are observed. However, considering that it is a forecast result for the future period, it will be sufficiently useful as information for the evaluation or operation of water resources in the future.

A Comparative Study on Resident and Tourist Value Systems of the Ancient Tombs in Gyeong-ju City Center - A Focus on Means-End Chain - (경주 도심 고분에 대한 지역주민과 관광객의 가치체계 비교연구 - 수단-목적 사슬 이론을 중심으로 -)

  • Seok, Mi-Jeong;Park, Joung-Koo;Kang, Tai-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.2
    • /
    • pp.88-99
    • /
    • 2019
  • This study aims to conduct a depth analysis of motivation and value of local residents and tourists based on means-end chain theory. The sampling of the study was conducted on local residents living near downtown area of Gyeong-ju City, and tourists through soft laddering and hard laddering methods. A mutual correlation model in relation with Hierarchical Value Map (HVM) for each group by conducting the analysis of factor loading (attributes, consequences, value) and cognitive structure (the correlations among attributes, consequences and value) was proposed and the comparisons of HVM for each group was also conducted. The structured questionnaires using Association Pattern Technique (APT) of hard laddering were utilized to analyze the means and end of value chain structures in terms of the attributes, consequences, value of Gyeong-ju Ancient Tombs. The findings propose that local residents are visiting Ancient Tombs Gyeong-ju City Center for 'Rest and take a walk' as the means, which results in 'Relieving stress' and eventually leads to the 'Improvement of historic and cultural cultivation' as the end. On the other hand, tourists also 'Rest and take a walk' as the mean, which also leads to 'Relieving stress'. However, unlike local residents, it eventually leads to 'Self-reflection and healing' as the end. It is expected that the findings of this study not only recommend us to consider preserving and managing cultural heritages and value of ancient tombs in developing "Ancient Tomb Park in Gyoneg-ju City Center" but also provides baseline data for the establishment of reasonable plans of utilizing tombs, historical and cultural heritages.

A Study on the Reconfiguration Effect of Busan Port Operator in Logistics Environment (물류환경변화에 따른 부산항 운영사 재구성효과에 관한 실증연구)

  • Park, Ho-Chul;Lee, Sung-Yhun;Ahn, Ki-Myung
    • Journal of Navigation and Port Research
    • /
    • v.42 no.6
    • /
    • pp.507-517
    • /
    • 2018
  • The probability of T/S cargo volume to decrease is the most notable problem associated with inappropriate mix of terminal operators in Busan port. Other problems include, the deterioration of the national carriers' competitiveness from non-operation of own terminal, excessively high proportion of financial operators in the engagement of operation which may result in their passiveness in timely investment, additional cost burden to carriers' in the handling inter-terminal T/S cargo transportation and inefficiency in terminal operation by the multiplicity of operators proved to be same recognized as so through the analysis. Therefore, in order to provide solutions for the problems and to strengthen Busan port's competitiveness, this research suggests the restructuring of operators mix as follows. To achieve sustainable growth of T/S cargo, global carriers' participation in terminal operation should be of utmost priority. To enhance the operational efficiency, the operators should be integrated. Similarly, the integration of operators will play a key role in verifying that national carriers' own terminal operation is an important factor in raising its competence. Finally, BPA's active engagement in the entire operation of port is also critical in public-oriented operation of the port. Whereas in the interactive analysis by taking the merits of Busan port into consideraion, global carrier's participation in operation, integration of operators and BPA's engagement in operation proved to contribute to the increase of T/S cargo and strengthening of operational efficiencies of Busan port.

A Study on the Establishment Case of Technical Standard for Electronic Record Information Package (전자문서 정보패키지 구축 사례 연구 - '공인전자문서보관소 전자문서 정보패키지 기술규격 개발 연구'를 중심으로-)

  • Kim, Sung-Kyum
    • The Korean Journal of Archival Studies
    • /
    • no.16
    • /
    • pp.97-146
    • /
    • 2007
  • Those days when people used paper to make up and manage all kinds of documents in the process of their jobs are gone now. Today electronic types of documents have replaced paper. Unlike paper documents, electronic ones contribute to the maximum job efficiency with their convenience in production and storage. But they too have some disadvantages; it's difficult to distinguish originals and copies like paper documents; it's not easy to examine if there is a change or damage to the documents; they are also prone to alteration and damage by the external influences in the electronic environment; and electronic documents require enormous amounts of workforce and costs for immediate measures to be taken according to the changes to the S/W and H/W environment. Despite all those weaknesses, however, electronic documents increasingly account for more percentage in the current job environment thanks to their job convenience and efficiency of production costs. Both the government and private sector have made efforts to come up with plans to maximize their advantages and minimize their risks at the same time. One of the methods is the Authorized Retention Center which is described in the study. There are a couple of prerequisites for its smooth operation; they should guarantee the legal validity of electronic documents in the administrative aspects and first secure the reliability and authenticity of electronic documents in the technological aspects. Responding to those needs, the Ministry of Commerce, Industry and Energy and the Korea Institute for Electronic Commerce, which were the two main bodies to drive the Authorized Retention Center project, revised the Electronic Commerce Act and supplemented the provisions to guarantee the legal validity of electronic documents in 2005 and conducted researches on the ways to preserve electronic documents for a long term and secure their reliability, which had been demanded by the users of the center, in 2006. In an attempt to fulfill those goals of the Authorized Retention Center, this study researched technical standard for electronic record information package of the center and applied the ISO 14721 information package model that's the standard for the long-term preservation of digital data. It also suggested a process to produce and manage information package so that there would be the SIP, AIP and DIP metadata features for the production, preservation, and utilization by users points of electronic documents and they could be implemented according to the center's policies. Based on the previous study, the study introduced the flow charts among the production and progress process, application methods and packages of technical standard for electronic record information package at the center and suggested some issues that should be consistently researched in the field of records management based on the results.

The Place Where the Cabin or Flight Crew of International Air Carrier Habitually Carries Out his/her Work - CJEU, 2017. 9. 14., C-168/16, C-169/16 - Sandra Nogueira and Others v. Crewlink Ltd Miguel José Moreno Osacar v. Ryanair (국제항공운송 승무원의 일상적 노무제공지)

  • Kwon, Chang-Young;Kim, Sun-Ah
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.34 no.1
    • /
    • pp.39-77
    • /
    • 2019
  • Crew members engaged in international air transportation provide work in many countries due to the nature of their work. According to the Private International Act, the place where the employee habitually carries out his/her work plays an important role in the determination of the governing law of the international labor contract (Article 28, Paragraph 2) and in the decision of international jurisdiction (Article 28, Paragraphs 3 and 4). The concept of the place where the employee habitually carries out his/her work was proposed by the EU to determine international jurisdiction and governing law. In international aviation law, the legislative purpose of the place where the employee habitually carries out his/her work is different from that of home base, which is a concept introduced for fatigue management of the crew in order to secure the aviation safety; thus the place where the employee habitually carries out his/her work and home base are not the same concept. In order to determine the place where the employee habitually carries out his/her work, following matters should be considered comprehensively; (i) where the crew starts and ends work, (ii) where the aircraft the crew is performing work on is primarily parked, (iii) where the crew is informed of the instructions and organizes his/her work activities, (iv) where the crew is obliged to reside according to the labor contract, (v) where there is an office provided by the employer and available to the crew, (vi) where the crew is obliged to be when he/she is ineligible for the work or subject to discipline. However, since all of the above items are the same as the location of the home base, it is reasonable to consider the home base as the most important factor when deciding on the place where the employee habitually carries out his/her work. In contrast, the state where the aircraft is registered (Article 17 of the Chicago Convention), should not be regarded as a place of where the employee habitually carries out his/her work. In this case, CJEU provided the first judging standard for the concept of the place where the employee engaged in international air transportation habitually carries out his/her work. It is the interpretation of the Brussels regulations which became a model -for the Korean Private International Act,- so it would be helpful to understand the concept of the place where the employee habitually carries out his/her work.