• Title/Summary/Keyword: M2M application

Search Result 5,320, Processing Time 0.038 seconds

Studies on the Effect of the Thickness of Lining on Water Holding Capacity and Lield in Rice Patty with High Permeability (누수유에 있어서 밑다짐 두께의 차이가 보수력 및 수호량에 미치는 영향)

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.1
    • /
    • pp.1598-1603
    • /
    • 1969
  • A field expeperiment has been conducted in order to explore possibilities of efficient and economical irrigation methods for the rice cultivation through which irrigation water may be saved and rice paddies may keep water for longer period of time, resulting in an increased yield of rice. Some of the major findings from the experimentation are summarized in the following. 1. There is slightly significant difference among experimental plots in the weight of rice straw. 2. The 9cm-lined plot proves to be the best in terms of the thickness. In this connection, however, it seems to by 3cm. 3. The wheat straw-lined plot is found superior in yield. However, this may be resulted in by the application of more fertilizer, and how long the plot could be durable may be problematic. Since every two or three years the straw-lining work has to be done, more labour may be required of the plot. 4. It would be inappropriate to expect any meaningful experimental results for the first year, since surface soil and deep soil are mixed up in the course of work. There is not observed any meaningful difference in the number of ears per stalk and in the number of grains per ear. However, in the lined plots, the number of tillers is slightly increased. 5. Irrigation has been applied by means of ordinary method after lining. When irrigation is applied at the interval of five to six days, irrigation water is saved by 44.9 per cent in the case of 9cm-lined plot, 39.7 per cent in the case of 6 cm-lined plot, and 36.3 percent in the case of 3 cm-lined plot. 6. An increased yields arenoted in the wheat straw-lined plot by 23.8 per cent, in the 9 cm-lined plot by 20.1 per cent, in the 3 cm-lined plot by 12 per cent. and in the case of vinyl-lined plot by 12.5 per cent. 7. The rate of maturity of grains is proved better, and the husking rate also found better(75%), that is, the quality of rice grains is improved.

  • PDF

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.

Comparison of Soil Nutrient Status in Conventional and Organic Apple Farm (관행농 및 유기농 사과과수원 토양의 양분함량 비교)

  • Chung, Jong-Bae;Lee, Yoon-Jung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.1
    • /
    • pp.26-33
    • /
    • 2008
  • Soil nutrient status in an organic apple farm was evaluated in relation to a conventional farm to better understand the effects of organic farming system on soil fertility. Soil organic matter, total and mineral N, available P, exchangeable cations, and available micronutrients were monitored at depth of 5-20 cm from May to October in 2006. Average soil organic matter content was 63.3 and $31.0g\;kg^{-1}$ in organic and conventional farm, respectively. Total N content was 3.3 and $1.7g\;kg^{-1}$ in average for organic and conventional farm, respectively. Ammonium and nitrate N in organic farming were maintained at relatively stable levels, but in the conventional farm the levels were very high in early season due to the chemical fertilizer application. In the organic apple farm, available P content in May was lower than that found in the conventional farm, but during the growing season available P content was continuously increased and in August the content was more than $1000mg\;P_2O_5\;kg^{-1}$. The organic farm maintained relatively greater exchangeable K, Ca, and Mg levels than the conventional farm. Available Cu, Fe, and Mn contents in the conventional farm were relatively greater than those found in the organic farm. However, available Zn extracted in 0.1 M HCl was much greater in the organic farm. Nutrient levels above crop needs were observed in both conventional and organic apple farm suggesting a more appropriate management of soil nutrients in organic farming to secure its fundamental functions for the sustainable agriculture.

Tensile Bond Strength of Composite Resin Treated with Er:YAG Laser (Er:YAG 레이저를 활용한 와동형성시 컴포짓 결합강도)

  • Shin, Min;Ji, Young-Duk;Rhu, Sung-Ho;Cho, Jin-Hyoung
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.269-276
    • /
    • 2005
  • This in vitro study evaluated the influence of a flowable composite resin on the tensile bond strength of resin to enamel and dentin treated with Er:YAG laser and diamond bur. 96 Buccal enamel and mid-coronal dentin were laser-irradiated using an Er:YAG laser and treated with diamond bur. Each groups(48) were divided two small groups depends on acid-etching procedure. Light-cure flowable resin(Metafil Flo) and self-cure resin(Clearfil FII New Bond) were used in this study. After surface etching with 37% phosphoric acid and the application of an adhesive system, specimens were prepared with a hybrid composite resin. After 24hours storage in distilled water at 37$^{\circ}C$, all samples were submitted to the tensile bond strength evaluation, using a universal testing machine(Z020, Zwick, Germany). The obtained results were as follows: 1. TBS of acid-etching group were higher than those of non-etching group in both enamel and dentin treated with Er:YAG laser and diamond bur. Laser 'conditioning' was clearly less effective than acid-etching. Moreover, acid etching lased enamel and dentin significantly improved the microTBS of M-Flo. 2. In enamel, TBS of laser-irradiated group were lower than those of bur-prepared group. However, in flowable resin subgroup, there were not differed those between two groups in dentin. 3. In laser-treated group, TBS of flowable composite resin were higher than those of self-curing resin in dentin, however, there was no difference in enamel. From this study, we can conclude that the self- and light-cure composite resin bonded significantly less effective to lased than to bur-cut enamel and dentin, and that acid-etch procedure remains mandatory even after laser ablation. We suggest that Er:YAG laser was useful for preparing dentin cavity with flowable resin filling.

The Design and Application of Vibrator Type(AM) Combination Apparatus for Improving Police Equipment for Fugitive Prevention (도주방지용 경찰장구의 기능개선을 위한 진동자 방식(AM) 결속장치 설계 및 응용)

  • Choi, Ki-Nam;Lee, Seon-Jeh
    • Convergence Security Journal
    • /
    • v.11 no.2
    • /
    • pp.13-24
    • /
    • 2011
  • Policemen judge the situations rationally and use their equipment such as handcuffs and rope within the purview, finding them needed to arrest criminals in the act who commit crimes which conforms to death penalty, life imprisonment or long imprisonment for over 3 years in accordance with Clause 10-2, Article 1 of the Police Mandate Law and prevent fleeing from them, defend their and others' lives and bodies, or if there are probable causes to be recognized that using equipment is necessary to restrain the interference with government officials in the execution of their duties. However, as the cases which the criminals run away in handcuffs or with both hands tied occur, it results in the waste of police force, distrust and enormous trouble in the pursuit of their duties. Therefore, if the way to perceive fleeing of criminals who have already worn the police equipment by some simple assistive devices without developing other new equipment, it will be very effective for police duties. This study is about the combination apparatus for fugitive prevention attached to the existing handcuffs and rope whose alert sounds let the staffs working inside the office perceive the fleeing of wanted criminals and examined suspects who wear the handcuffs or are tied up with rope, providing that they go through the exit where a transmitter and a receiver were set. The combination apparatus for fugitive prevention which the study introduces contains the connecting parts which connect a flexible tube(cognition tags inside of the tube) of connector equipped with the police equipment with the ends of the tube and the part where these two meet and which connect them inside of the tube. The connecting parts are easy to be attached to the police equipment such as handcuffs and rope, but hard to be dismantled by the people tied up with the equipment. It enables watchers to perceive the fleeing of wanted criminals and examined suspects who wear the handcuffs or are tied up with rope, providing that they go through the exit where a transmitter and a receiver were set. Plus, if it is combined together with the portable receiver, it can be installed on the patrol cars and easily adopted to supervise illegally accessing of evidences. It is also avaliable to be adjunctively utilized for the handcuffs provided and the cost is so reasonable. Owing to its snap-on way to the cuffs, it can clear up any invasion of privacy and it can not be used as a self-injury tool because of the soft tube. Using AM Tag minimizes the lack of malfunction.

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES (복합레진의 광중합 전·후와 shade guide의 색차 비교)

  • Chon, Yi-Ju;Cho, Sung-Shik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

Immunogenicity of Synthetic Peptide Specific for Major Immunogenic Determinat of Hepatitis B Surface Antigen (B형간염(型肝炎) 표면항원(表面抗原)의 주면역원(主免疫原) 결정기(決定基)에 특이(特異)한 합성(合成) Peptide의 면역원성(免疫原性)에 관한 연구(硏究))

  • Shin, Kwang-soon;Han, Su-nam
    • Korean Journal of Veterinary Research
    • /
    • v.25 no.1
    • /
    • pp.7-17
    • /
    • 1985
  • Many investigators have been pursuing various attempts so far to produce hepatitis B surface antigen(HBsAg) vaccines using the techniques such as isolation from plasma of chronic HBsAg carrier, recombinant DNA technique or preparation of synthetic peptides specific for immunogenic determinants. Hepatitis B virus can not grow on any cell lines by the tissue culture technique at the present time. The plasma of chronic HBsAg carrier is expensive and its source is limited. The HBsAg from the recombinant DNA technique gave still very low yield. Another approach, therefore, has been initiated to develop a synthetic hepatitis B virus vaccine. The possible use of several distinct synthetic vaccines in prophylaxis can be facilitated by availability of full synthetic immunogens. Peptides synthesized for potential application as antiviral vaccines have been mostly tested in the form of conjugates with carrier proteins, although the free synthetic peptide can be immunogenic. To understand basic knowledges on the antigenicity and immunogenicity of a synthetic peptide specific for major immunogenic determinant of HBsAg, a nonapeptide, $H_2N^{139}Cys-Thr-Lys-Pro-Thr-Asp-Gly-^{146}Asn-Aba$ COOH, which corresponds to HBsAg amino acid residues 139 to 147, was synthesized by the Merrifield's solid-phase method with a slight modification. The antigenicity and immunogenicity of this specific synthetic peptide were examined comparing with purified plasma-derived natural HBsAg. The results obtained are as follows; 1. The peptide synthesized showed the identical amino acid composition to the theoretical value. The degree of purification and molecular weight were acertained by methods of high performance liquid chromatography and mass spectrometry. 2. Using m-maleimidobenzoyl-N-hydroxysuccinimide ester as a conjugating agent, the synthetic peptide was conjugated to rabbit albumin and ${\gamma}$-globulin, tetanus and diphtheria toxoids, and keyhole limpet hemocyanin. Their conjugation yields were 8.3, 9.5, 15.8, 13.5, and 11.2%, respectively. 3. The natural HBsAg was purified from plasma of chronic HBsAg carrier. By the electron microscopic observation of the purified natural HBsAg preparation, no Dane particles were observed and the preparation showed negative DNA polymerase activity. 4. Antigenicity of the synthetic peptide and the plasma-derived natural HBsAg was determined by competition radioimmunoassay using $^{125}I$-natural HBsAg. Their 50% inhibitions appeared as $90{\mu}g/ml$ and $0.12{\mu}g/ml$ for the synthetic peptide and the natural HBsAg, respectively. This indicates that the former was about 750-fold less antigenic than the latter. 5. Immunogenicity of the synthetic peptide was determined by administering the peptide-carrier conjugates into rabbits with and without Freund's complete adjuvant. Regardless the carrier proteins and adjuvant, positive immune responses to the synthetic peptide were observed. The higher antibody titers, however, were shown in the groups administered with Freund's complete adjuvant. 6. Immunizing dose 50% in mice of the various peptide-carrier conjugates was 5.47, 6.00, 65.16, 31.25 and $13.03{\mu}g/dose$ for rabbit albumin and ${\gamma}$-globulin, tetanus and diphtheria toxoids, and keyhole limpet hemocyanin, respectively, while the natural HBsAg showed $0.65{\mu}g/dose$. 7. It was postulated that homologous proteins prefer to heterologous ones as the carriers.

  • PDF

Estimation of Annual Trends and Environmental Effects on the Racing Records of Jeju Horses (제주마 주파기록에 대한 연도별 추세 및 환경효과 분석)

  • Lee, Jongan;Lee, Soo Hyun;Lee, Jae-Gu;Kim, Nam-Young;Choi, Jae-Young;Shin, Sang-Min;Choi, Jung-Woo;Cho, In-Cheol;Yang, Byoung-Chul
    • Journal of Life Science
    • /
    • v.31 no.9
    • /
    • pp.840-848
    • /
    • 2021
  • This study was conducted to estimate annual trends and the environmental effects in the racing records of Jeju horses. The Korean Racing Authority (KRA) collected 48,645 observations for 2,167 Jeju horses from 2002 to 2019. Racing records were preprocessed to eliminate errors that occur during the data collection. Racing times were adjusted for comparison between race distances. A stepwise Akaike information criterion (AIC) variable selection method was applied to select appropriate environment variables affecting racing records. The annual improvement of the race time was -0.242 seconds. The model with the lowest AIC value was established when variables were selected in the following order: year, budam classification, jockey ranking, trainer ranking, track condition, weather, age, and gender. The most suitable model was constructed when the jockey ranking and age variables were considered as random effects. Our findings have potential for application as basic data when building models for evaluating genetic abilities of Jeju horses.

Studies on the Selection Efficiency for Clear Rice in the wx - carrier technique. (wx-Carrier Technique를 이용한 맑은 쌀의 선발에 관한 연구)

  • Heu, M.H.;Kim, H.Y.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 1984
  • The main objective of this experiment was to investigate the selection efficiency for clear rice by the application of the wx-carrier technique in rice. Twelve semi-dwarf waxy lines were bred through backcrosses to the two recurrent semi-dwarf parents, IR667 and IR1317, utilizing six different waxy cultivars as waxy donor parent. These waxy lines were crossed to three clear non-waxy varieties, IR24, Suweon 287 and Suweon294. Their F$_3$ seeds were separated into waxy and non-waxy and the clearness of non-waxy grains were counted. The results are summarized as follows: l. Mean clearness per plant for twelve waxy lines ranged from 3.7% to 78.9% at the 35 days after heading. It was higher in the lines which utilized IR 1317 as recurrent parent and it was lower in the lines which utilized IR667 as recurrent parent. Mean clearness per plant for recurrent parent, IRl317 and IR667 were 47.6% and 5.6% respectively. The clear non-waxy parents; Suweon287, IR24 and Suweon294 showed 83.7% 80.5% and 73.5% clearness respectively. 2. Mean clearness of F$_3$ seeds of the crosses between different waxy parents and IR24, Suweon 294 and Suweon 287 ranged 16.7-73.9%, 21.9-42.9% and 10.6-26.9%, respectively. IR24 crosses showed the highest mean clearness. 3. Highly positive correlation was found between the clearness of F$_3$ seeds of Suweon 287 crosses and those of Suweon294. 4. Significant differences were observed in mean clearness of F$_3$ seeds of the crosses between the different waxy lines, which was bred through the same number of backcrosses to the same recurrent parent, and a clear non-waxy parent. Crosses of IR1317 recurrent parent showed higher mean clearness than those of IR667 recurrent parent. 5. In some crosses, clearness was higher in homo-non-waxy than in hetero-non-waxy, but, in other crosses it was higher in hetero-non-waxy. Thus no distinct pattern in the segregation of clearness was observed along the homo-non-waxy or hetero-non-waxy. 6. From the results it was concluded that, the selection efficiency for the clear rice can be improved by choosing the proper waxy parent, as well as proper recurrent parent under the wx-carrier technique.

  • PDF