Abstract
This in vitro study evaluated the influence of a flowable composite resin on the tensile bond strength of resin to enamel and dentin treated with Er:YAG laser and diamond bur. 96 Buccal enamel and mid-coronal dentin were laser-irradiated using an Er:YAG laser and treated with diamond bur. Each groups(48) were divided two small groups depends on acid-etching procedure. Light-cure flowable resin(Metafil Flo) and self-cure resin(Clearfil FII New Bond) were used in this study. After surface etching with 37% phosphoric acid and the application of an adhesive system, specimens were prepared with a hybrid composite resin. After 24hours storage in distilled water at 37$^{\circ}C$, all samples were submitted to the tensile bond strength evaluation, using a universal testing machine(Z020, Zwick, Germany). The obtained results were as follows: 1. TBS of acid-etching group were higher than those of non-etching group in both enamel and dentin treated with Er:YAG laser and diamond bur. Laser 'conditioning' was clearly less effective than acid-etching. Moreover, acid etching lased enamel and dentin significantly improved the microTBS of M-Flo. 2. In enamel, TBS of laser-irradiated group were lower than those of bur-prepared group. However, in flowable resin subgroup, there were not differed those between two groups in dentin. 3. In laser-treated group, TBS of flowable composite resin were higher than those of self-curing resin in dentin, however, there was no difference in enamel. From this study, we can conclude that the self- and light-cure composite resin bonded significantly less effective to lased than to bur-cut enamel and dentin, and that acid-etch procedure remains mandatory even after laser ablation. We suggest that Er:YAG laser was useful for preparing dentin cavity with flowable resin filling.
Keywords
tensile bond strength; Er:YAG laser; flowable composite resin;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Hibst R, Keller U, Stainer R. The effect of pulsed Er:YAG laser radiation on dental hard tissues. Laser Med Surg 1988; 4: 163-165
2 Tyas MJ, Anusavice KJ, Frencken JE. Minimal intervention dentistry a review. Int Dent J 2000; 50:1-12   DOI   ScienceOn
3 Visuri SR, Gilbert JL, Wright DD, Wigdor HA, Walsh JT. Shear strength of composite bonded to Er:YAG laser-prepared dentin. J Dent Res 1996; 75: 599-605   DOI   ScienceOn
4 Attrill DC, Farrar SR, King TA, Dickinson MR, Davies RM, Blinkhon AS. Er: YAG ( = 2.94 $\mu m$) laser etching of dental enamel as an alternative to acid etching. Lasers Med Sci 2000; 15: 154-161   DOI   ScienceOn
5 Donadio-Moura J, Gouw-Soares S, Freitas PM, Navarro RS, Powell LG, Edurado CP. Tensile bond strength of a flowable composite resin to Er:YAGlaser-treated dentin. Laser Surg Med 2005; 9999:1-5
6 Tay FR, Carvalho R, Sano H, Pashley DH. Effect of smear layers on the bonding of a self-etching primer to dentin. J Adhesive Dent 2000; 2: 99-116
7 Shono Y, Terashita M, Pashley EL, Brewer PD, Pashley DH. Effects of cross-sectional area on resin-enamel tensile bond strength. Dent Mater 1997; 13: 290-296   DOI   ScienceOn
8 Kameyama A, Oda Y, Hirai Y, Kawada E, Takizawa M, Resin bonding to Er:YAG laser-irradiated dentin: combined effects of pre-treatments with citric acid and glutaraldehyde. Eur J Oral Sci 2001; 109: 354-360   DOI   ScienceOn
9 Souza AE, Corona SAM, Palma-Dibb RG, Borsatto MC, Pécora JD. Influence of Er:YAG laser on tensile bond strength of a self-etching system and a flowable resin in different dentin depths. J Dent 2004; 32: 269-275   DOI   ScienceOn
10 Ramos RP, Chinelatti MA, Chimello DT, Borsatto MC, Pecora JD, Palma-Dibb RG. Bonding of self-etching and total-etch systems to Er:YAG laser-irradiated dentin. Tensile bond strength and scanning electron microscopy. Braz Dent J 2004; 15: SI9-SI20   DOI   ScienceOn
11 Mehl A, Folwaczny M, Haffner C, Hickel R. Bactericidal effects of 2.94 microns Er:YAG-laser irradiation in dental root canals. J Endod 1999; 25:490-493   DOI   ScienceOn
12 Schoop U, Moritz A, Kluger W, Patruta S, Goharkhay K, Sperr W, Wernisch J, Gattringer R, Mrass P, Georgopoulos A. The Er:YAG laser in endodontics: Results of an in vitro study. Lasers Surg Med 2002;30: 360-364   DOI   ScienceOn
13 de Munck J, van Meerbeek B, Inoue S, Vargas M, Yoshida Y, Armstrong S, Lambrechts P, Vanherle G. Micro-tensile bond strengths of one- and two-step self-etch adhesives to bur-cut enamel and dentin. Am J Dent 2002; 15: in press
14 Yoshiyama M, Matsuo T, Ebisu S, Pashley D. Regional bond strengths of self-etching/self-priming adhesive systems. J Dent 1998; 26: 609-616   DOI   ScienceOn
15 van Meerbeek B, Perdigão J, Lambrechts P, Vanherle G. The clinical performance of adhesives. J Dent 1998; 26: 1-20   DOI   ScienceOn
16 Perin FM, Franca SC, Silva-Souza YT, Alfredo E, Saquy PC, Estrela C, Souza-Neto MD. Evaluation of Er:YAG laser irradiation versus 1% sodium hypochlorite irrigation for root canal disinfection. Aust Endod J 2004; 30: 20-22   DOI   ScienceOn
17 Kameyama A, Kawada E, Takizawa M, Oda Y, Hirai Y. Influence of different acid conditioners on the tensile bond strength of 4-META/MMA-TBB resin to Er:YAG laser- irradiated bovine dentin. J Adhesive Dent 2000; 2: 297-304
18 Armengol V, Jean A, Rohanizadeh R, Hamel H. Scanning electron microscopic analysis of diseased and healthy dental hard tissues after Er:YAG laser irradiation: in vitro study. J Endodont 1999; 25:543-546   DOI   ScienceOn
19 Yamamoto H, Sato K. Prevention of dental caries by Nd:YAG laser irradiation. J Dent Res 1980; 59:2171-2177
20 Keller U, Hibst R. Er:YAG laser effects on oral hard and soft tissues. In: Miserendino LJ, Pick RM, eds. Lasers in dentistry. Chicago: Quintessence Publishing, 1995; 161-172
21 김근아, 안용우, 고명연, 박준상. Er:YAG 레이저를 이용한 법랑질과 상아질의 절삭율 연구. 대한구강내과학회지. 2005;30:131-140
22 Pashley DH, Carvalho RM, Sano H, Nakajima M, Yoshiyama M, Shono Y, Fernandes CA, Tay F. The microtensile bond test: a review. J Adhesive Dent 1999; 1: 299-309
23 Nakabayashi N, Kojima K, Masuhara E. The promotion of adhesion by the infiltration of monomers into tooth substrates. J Biomed Mater Res 1982; 16: 265-273   DOI   ScienceOn
24 Hibst R, Keller U. Experimental stuies of the application of the Er:YAG laser on the dental hard substances: I. Measurement of the ablation rate. Laser Surg Med 1989;9:338-344   DOI   ScienceOn
25 Paghdiwala AF, Vaidyanahan TK. Evaluation of Er:YAG laser radiation of hard dental tissue: analysis of temperature change, depth of cuts and structural effects. Scanning Micros. 1993;7:989-997
26 Inoue S, Vargas MA, van Meerbeek B, Abe Y, Yoshida Y, Lambrechts P, Vanherle G, Sano H. Micro-tensile bond strength of eleven modern adhesives to dentin. J Adhesive Dent 2001; 3: 237-246
27 van Meerbeek B, Vargas M, Inoue S, Yoshida Y, Peumans M, Lambrechts P, Vanherle G. Adhesives and cements to promote preservation dentistry. Oper Dent 2001; 26: 119-144
28 Kinney JH, Haupt DL, Balooch M, White JM, Bell WL, Marshall SJ, Marshall GW. The threshold effects of Nd and Ho:YAG laser-induced surface modification on demineralisation of dentin surfaces. J Dent Res 1996; 75: 1388-1395   DOI   ScienceOn
29 Degrange H, Roulet JF. Minimally Invasive Dentistry with Bonding. Chicago: Quintessence Publishing, 1997
30 Wahle JJ, Wendt SL Jr. Dentinal surface roughness: a comparison of tooth preparation techniques. J Prosthet Dent 1993; 69: 160-164   DOI   ScienceOn
31 Glockner K, Rumpler J, Ebeleseder K, Stadtler P. Intrapulpal temperature during preparation with the Er:YAG laser compared to the conventional bur: An in vitro study. J Clin Laser Med Surg 1998; 16: 153-157
32 Gouw-Soares S, Pelino JEP, haypek P, Bachmann L, Eduardo CP. Temperature rise in cavities prepared in vitro by Er:YAG Laser. J Oral Laser Appl 2001; 1:119-123
33 Goncalves M, Corona SAM, Borsatto MC, Silva PCG, Pecora JD. Tensile bond strength of dentin-resinous system interfaces conditioned with Er:YAG laser irradiation. J Clin Laser Surg Med 2002; 20: 89-93   DOI   ScienceOn
34 Carvalho RM, Santiago SL, Fernandes CAO, Suh BI, Pashley DH. Effects of prism orientation on tensile strength of enamel. J Adhesive Dent 2000; 2: 251-257
35 Hibst R, Keller U. Effect of water spray and repetition rate on the temperature elevation during Er:YAG laser ablation of dentin. SPIE 1995;2623:139-144
36 Kataumi M, Nakajima M, Yamada T, Tagami J. Tensile bond strength and SEM evaluation of Er:YAG laser irradiateddentin using dentin adhesive. Dent Mat J 1998; 17: 125-138   DOI   ScienceOn