• Title/Summary/Keyword: M.W. Fraction

Search Result 233, Processing Time 0.029 seconds

Dynamic Performance Simulation of OTEC According to Seawater Temperature Change (해수온도변화에 따른 온도차발전시스템의 동적 성능 시뮬레이션)

  • Lim, Seung-Taek;Lee, Ho-saeng;Kim, Hyeon-Ju
    • Journal of Power System Engineering
    • /
    • v.22 no.1
    • /
    • pp.34-40
    • /
    • 2018
  • In this paper, Performance of 1MW OTEC system using R32 with varying seawater temperature range is studied. Steady state cycle is designed and its output and generation efficiency were 1,014kW and 2.72%, respectively. Compared to dynamic cycle, system performance and change during long term operation is studied. The simulation is performed by decreasing surface seawater temperature from $29^{\circ}C$ to $25^{\circ}C$ with 20 minute of reaction time. Dynamic cycle with same condition applied to steady state cycle and it showed output and efficiency of 1,020kW and 2.75% respectively. Seawater temperature decreased from $29^{\circ}C$ and the vapor fraction of refrigerant decreased below 1 at $28^{\circ}C$. While the vapor fraction was above 1, the turbine output decreased by 0.017kW per second. After the seawater temperature reached $26.2^{\circ}C$, the turbine output decreased by 1.03kW per second. However, Driving the turbine below the saturation temperature caused the occurrence of surging and the influx of liquid refrigerant. When the liquid separator having a capacity of 1.0 m3 was used, the flow into the turbine was confirmed after 5 minutes from the first liquid refrigerant coming into the separator.

Angiotensin I Converting Enzyme Inhibitory Activity of Krill (Euphausia superba) Hydrolysate

  • Kim Dong-Soo;Park Douck-Choun;Do Jeong-Ryong
    • Fisheries and Aquatic Sciences
    • /
    • v.5 no.1
    • /
    • pp.21-27
    • /
    • 2002
  • Angiotensin I converting enzyme inhibitory activities of shelled krill (Euphausia superba) hydrolysates by autolysis and by hydrolysis with commercial proteases were analyzed. Among the proteases, Alcalase was the most effective protease for the hydrolysis of krill considering the degree of hydrolysis $(87.5\%)$ and the ACE inhibitory activity $(60\%)$. Four hour hydrolysis suggested as the most suitable and economic. In order to establish the optimum hydrolysis condition of krill, degree of hydrolysis and ACE inhibitory activity as affected by Alcalase concentration and water amount added were statistically analyzed by response surface methodology (RSM). The optimum hydrolysis condition was $2.0\%$ Alcalase hydrolysis in 2 volumes (v/w) of water at $55\% for 4 hr. The hydrolysate prepared from the optimum hydrolysis condition was fractionated by molecular weight. The lower molecular weight fraction showed the higher ACE inhibitory activity. $IC_{50}$ of the fraction under 500 Da was 0.57mg protein/mL.

Mechanistic Pressure Jump Terms based on the System Eigenvalues of Two-Fluid Model for Bubbly Flow (2-유체 모델의 고유치에 근거한 기포류에서의 계면압력도약항)

  • Chung, M.S.;Lee, W.J.;Lee, S.J.;Song, C.H.;Ha, K.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.81-86
    • /
    • 2001
  • Interfacial pressure jump terms based on the physics of phasic interface and bubble dynamics are introduced into the momentum equations of the two-fluid model for bubbly flow. The pressure discontinuity across the phasic interface due to the surface tension force is expressed as the function of fluid bulk moduli and bubble radius. The consequence is that we obtain from the system of equations the real eigenvalues representing the void-fraction propagation speed and the pressure wave speed in terms of the bubble diameter. Inversely, we obtain an analytic closure relation for the radius of bubbles in the bubbly flow by using the kinematic wave speed given empirically in the literature. It is remarkable to see that the present mechanistic model using this practical bubble radius can indeed represent both the mathematical well-posedness and the physical wave speeds in the bubbly flow.

  • PDF

Effect of pore characteristics of activated carbon on adsorption of natural organic matter (활성탄의 세공이 자연유기물질의 흡착에 미치는 영향)

  • Pak, Jung-Sun;Hong, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.249-255
    • /
    • 2011
  • It is complicate problem to optimize removing natural organic matter (NOM) by activated carbon in drinking water treatment because the activated carbon has heterogeneous surface area and pore structure. Seven different coals based activated carbons which have different pore structures were used in the study. Sand filtered effluents which normally used as GAC adsorber influent were used. The molecular weight distribution showed that most of the NOM was bigger than 10,000Da. In this study, systematical approaches such as characteristics of surface area and pore volume were evaluated on NOM adsorption. Especially, the adsorption capacities for NOM were evaluated by effect of micro-pores and meso-pores in surface area and pore structure. The results show that the higher ratio of meso-pore compare to the micro-pore has not only the better adsorption capacities for NOM but also the higher strongly-adsorbable fraction. Therefore, the overall adsorption capacity is increased with higher meso-pore ratio with existing of reasonable micro-pore surface area and volume.

An Experimental Study of the Effect of Flow on Flame Propagation in a Constant-Volume Combustion Chamber (정적연소기내 유동형태가 화염전파에 미치는 영향 연구)

  • Jeong, D.S.;Oh, S.M.;Suh, S.W.;Chang, Y.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.2
    • /
    • pp.136-145
    • /
    • 1995
  • The aim of this study is to gain a better understanding of the effect of a flow motion on the flame development by means of an optically-accessible constant-volume combustion chamber and the visualization technique of a combustion flame. At first, the characteristics of a flame propagation are investigated in the combustion field of the two kinds of flow conditions such as a quiescent and a flowing condition, and methane-air mixture is used as fuel. Then the same investigation is performed in two flow configurations : bulk flow motion type and turbulence generating type. In this study, the combustion phenomena are analyzed by measuring the combustion pressure, flame propagation speed, mean velocity, turbulent intensity, and mass fraction burned.

  • PDF

Studies on Active Principles of Leonurus sibiricus (익모초의 약효 성분에 관한 연구(I))

  • Shin, Soon-Hee
    • Korean Journal of Pharmacognosy
    • /
    • v.15 no.2
    • /
    • pp.104-107
    • /
    • 1984
  • The essential oil fraction of Leonurus sibiricus was analyzed by TLC and gas chromatography. By utilizing silica gel column, a ketone compound, m.w. 167, was isolated from the essential oil. The essential oil showed considerably the diuretic action, but the water extract exhibited weak action. This diuretic action of the water extract was potentiated by combined administration of essential oil. On the isolated rabbit's uterus the essential oil decreased spontanous movement and showed relaxation.

  • PDF

Microcrystalline Silicon for Thin Film Transistor

  • Milovzorov, D.;Kim, K.B.;Lisachenko, M.;Seo, J.W.;Lee, K.Y.;Chung, H.K.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1320-1322
    • /
    • 2005
  • Microcrystalline silicon films were deposited on glass substrate by using plasma-enhanced chemical vapor deposition (PECVD) method. The crystalline volume fraction was estimated by means of Raman spectrometer with argon laser as light source. The high hydrogen dilution of silane gas was used for increase in content of crystal silicon phase.

  • PDF

Analysis on the Energy Performance of Solar Water Heating System according to the Configuration of Flat Plate Collectors (태양열급탕시스템의 집열기 배열에 따른 에너지성능 분석 및 평가)

  • Ko, Myeong-Jin;Lim, Bo-Min;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.49-56
    • /
    • 2016
  • The objective of this work is to analyze the variation in energy performance for each flat plate collector connected in series. In this study, it was assumed that solar water heating system with annual solar fraction of 60% was installed in an office building in Seoul, South Korea. The transient energy performance corresponding to four cases, which are selected using different solar radiation and outdoor air temperature, is studied by analyzing the variation in outlet temperature, solar useful heat gain, and thermal efficiency of each collector. It is observed that the useful heat gain and the collector efficiency decrease continuously, and outlet temperature increases when increasing the number of collector connected in series. The long-term performance is assessed by evaluating the thermal efficiency of each collector for two solar radiation conditions ranging from 780 to $820W/m^2$ and from 380 to $420W/m^2$. It is found that the differences between the intercept and slope of the efficiency curves for first and eighth collectors are 3.68% and 6.74% for solar radiation of $800{\pm}20W/m^2$ and 8.57% and 12.90% for solar radiation of $400{\pm}20W/m^2$, respectively. In addition, it is interesting to note that annual useful heat gain and collector efficiency are reduced with similar rate of about 6.13% when increasing the collector area by connecting the collectors in series.

The Effect of $K^+$ on the Inotropic Action of Acontium Tuber (부자 "부타놀" 분획의 강심 작용에 대한 Potassium 이온의 효과)

  • Hong, S.A.;Kim, M.S.;Park, C.W.
    • The Korean Journal of Pharmacology
    • /
    • v.13 no.2
    • /
    • pp.11-17
    • /
    • 1977
  • The effects of varing concentrations of extracellular potassium on the positive inotropic actions of Aconiti tuber butanol fraction and ouabain were studied on isolated left atrium of rat. The patterns of active tension increment, such as time to peak and total duration of tension development, was contrasted in Aconiti tuber butanol fraction to ouabain. Ouabain did not induce significant shortening in time to peak and total duration of tension development, but Aconiti tuber produce significant shortening. The isometric tension and peak dF/dt were not significantly different at the range of extracellular potassium concentration $2mEq{\sim}10mEq$ per. liter in control studies. The ouabain-induced increase in active tension and peak dF/dt at 2mEq. per. liter potassium concentration was significantly different from that of 6mEq or 10mEq. per. liter, but there was no difference between 6mEq and 10mEq. per. liter. but Aconiti tuber is not. In contrast to ouabain, Aconiti tuber butanol fraction did not show potassium dependent positive inotropic effect. It produced almost same increment of tension and peak dF/dt at all the concentration of extracellular potassium concentrations in this experiment.

  • PDF

Study on the cooling performance of discrete heat sources using coolants (냉각제들에 따른 불연속 발열체의 냉각성능 연구)

  • 최민구;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.224-235
    • /
    • 1999
  • The present study investigated the effects of the experimental parameters on the cooling characteristics of the multichip module cooled by the indirect liquid cooling method using water, PF-5060, and paraffin slurry. The experimental parameters were coolants including Paraffin slurry with mass fraction of 2.5~7.5%, heat flux of 10~40W/$\textrm{cm}^2$ for the simulated VLSI chips and Reynolds numbers of 3,000~20,000. The size of paraffin slurry was constant as 10~40${\mu}{\textrm}{m}$ before and after the experiment. The chip surface temperatures for paraffin slurry were lower than those for water and PF-5060. The local heat transfer coefficients for the paraffin slurry were larger than those for water and the local heat transfer coefficients reached a row-number-independent and thermally-fully-developed value approximately after the third row. The local Nusselt numbers for paraffin slurry with a mass fraction of 7.5% were larger by 20~38% than those for water. The paraffin slurry with a mass fraction of 5% shelved the best thermal and hydrodynamic characteristics when local heat transfer and pressure drop were considered simultaneously.

  • PDF