• Title/Summary/Keyword: M-health system

Search Result 1,231, Processing Time 0.029 seconds

Investigation About Quality Control of General X-ray System

  • Kang, Byung-Sam;Son, Jin-Hyun;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.157-164
    • /
    • 2011
  • This test is for checking investigation about quality control of general X-ray system in clinic and hospital. We compared general X-ray system of clinic and hospital which are selected freely in the metropolitan area using PMX-III and carried out quality control. Carried out Kilovoltage test, mR/mAs output test, Light filed/Beam alignment test, Half value layer test. Most of test result are appeared that failure rates of clinic is higher than hospital one. Therefore, we should lower failure rates through regular quality control and make environment which can get high quality image.

  • PDF

Analyses of Security Issues for Internet of Things in Healthcare Application (헬스캐어 시스템에서의 사물 인터넷 통신을 위한 보안 문제 분석)

  • Shin, Yoon-gu;Kim, Hankyu;Kim, Sujin;Kim, Jung Tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.699-700
    • /
    • 2014
  • The use of Radio Frequency Identification technology (RFID) in medical context enables not only drug identification, but also a rapid and precise identification of patients, physicians, nurses or any other healthcare giver. The combination of RFID tag identification with structured and secured Internet of Things (IoT) solutions enables ubiquitous and easy access to medical related records, while providing control and security to all interactions. This paper defines a basic security architecture, easily deployable on mobile platforms, which would allow to establish and manage a medication prescription service in mobility context making use of electronic Personal Health Records. This security architecture is aimed to be used with a mobile e-health application (m-health) through a simple and intuitive interface, supported by RFID technology. This architecture, able to support secured and authenticated interactions, will enable an easy deployment of m-health applications. The special case of drug administration and ubiquitous medication control system, along with the corresponding Internet of Things context, is presented.

  • PDF

A Study on Improvement of Sewage Treatment System (오염처리장의 처리효율 개선연구)

  • 성일화
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.36-40
    • /
    • 1993
  • The objective of this research was to retrofit an on-site sewage treatment system suitable to current situation of Korea to reduce the pollution loading and preserve the invaluable water resources. Operation at the F/M ratio of 0.1 kg. BOD/kg MLSS day showed 87.1% BOD removal efficiency and 84.5% COD removal efficiency, and its effluent concentration was 6.4 mg/l as BOD and 21.7 mg/l as COD. Average removal of total nitrogen showed high removal efficiency of 80%.

  • PDF

Comparison of 2-dimensional marginal and internal fitness for the monolithic zirconia prosthesis using intraoral scanner and extraoral scanner: in vitro (Extraoral scanner와 intraoral scanner를 이용하여 제작된 zirconia crown의 2차원 변연 및 내면 적합도 비교: in vitro)

  • Lee, Tae-Hee;Lee, Ha-Bin;Kim, Ji-hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.187-193
    • /
    • 2019
  • Purpose: The purpose of this study was to compare two-dimensional fitness of the monolithic zirconia prosthesis by using different type of scanner. Methods: No. 26 abutment tooth of FDI system was selected for the study. Using the extraoral scanner and intraoral scanner, the abutment tooth was scanned 10 times and the scanned files were saved as STL files. CAD/CAM system was used to produce the monolithic zirconia prosthesis. marginal and internal gap of the monolithic zirconia prosthesis were measured by digital microscope(x160) and applied silicone replica technique was applied. t-test, a statistical software, was used to perform data analysis. Results: Marginal gap $mean{\pm}SD$ of the monolithic zirconia prosthesis was $33{\pm}7.5{\mu}m$ with extra oral scanner and $34.7{\pm}11.1{\mu}m$ with intraoral scanner. axial gap mean was $40.5{\pm}3.5{\mu}m$ with extra oral scanner and $44.6{\pm}11.6{\mu}m$ with intraoral scanner. occlusal gap mean was $110.1{\pm}25.4{\mu}m$ with extra oral scanner and $64{\pm}9.7{\mu}m$ with intraoral scanner. Conclusion: In this study, fabricating zirconia prosthesis with different type of scanner was clinically applicable.

Effectiveness of Obesity management programs: systematic review and meta-analysis (메타분석을 이용한 비만관리 프로그램의 효과분석)

  • Lee, Hyo-Young
    • Korean Journal of Health Education and Promotion
    • /
    • v.24 no.4
    • /
    • pp.131-147
    • /
    • 2007
  • As overweight and obese people have increased, obesity management programs have generated much concern in Korea. Many types of obesity management programs were operated, aimed at reducing weight, BMI, body fat percentage and so on. This study was conducted to review the features of studies in obesity management programs and systematically assess the effects which were published from 1995 to 2006 in Korea. Databases were systematically searched for published data in Korea. It were KISS (Korean studies information services system) and KERIS (Korean Education research information system), which were major literature search systems for all academic fields in Korea. Total 114 studies were initially identified, of which 21 satisfied our inclusion data. The effects of obesity management programs were assessed on the results in weight, BMI (body mass index), HDL (high density lipids), body fat percentage, self-efficacy. Effect size estimated on the equation of M1 - M2 / Sp, where M1 was mean of the experimental group, M2 was the mean of control group, and Sp was the pooled standard deviation. Magnitude of effect size was interpreted by using Cohen's definition. Cohen described small, medium, and large effect sizes as 0.2, 0.5, and 0.8 respectively. The studies about obesity management programs were the most published in 2005(26.1%). Obesity management programs were popularly operated as the type of 12 weeks intervention, exercise intervention(52.4%), quasi-experimental study(85.7%). Ten studies reported significant effects on weight, and nine studies reported significant effects on BMI and HDL. Only five and three studies reported significant effects on body fat percentage and self-efficacy respectively. The effects of each outcome were generally significant when the studies included these elements, intervention over 10 weeks, evaluation over 3 times, a comprehensive program (exercise, nutrition education, behavior modification) and reinforcing factors (self-monitoring, group discussion, one's goal setting, and etc.). Effective obesity management programs should contain these essential elements and objectives of obesity management programs must be set out evident at the beginning. The participants should be registered, educated and evaluated by continuous obesity management programs.

The Role of Social Work in Mental Health in a Variable Multicultural Environment

  • SEENIVASAN, R.
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.3 no.2
    • /
    • pp.21-26
    • /
    • 2020
  • The purpose of this article is to capture this situation within the changes that take place due to it, inside the Greek society where there is a great need for professional social workers who are able to work targeted and effectively with foreigners, both children and adults, who have or develop mental health problems for the very first time. Over the recent decades the increasing number of migration flows has exerted and continues to exert great pressure on the health system and on the welfare structures of Greece. The bases for the development of a rudimentary reception and integration system that still is in progress have been delayed, while there has been no happy medium, between the enormous pressure that foreigner users of this system put on, and the humanitarian obligation of a well-governed state towards all residents of the country. Straight through everyday clinical practice in the field of intercultural work, social work has the knowledge and techniques for a total management of emerging problems and at the same time provides a value system with an ethical background which approaches refugees and migrants in order to provide quality services, mostly to users of mental health services.

Dechlorination of High Concentrations of Tetrachloroethylene Using a Fixed-bed Reactor

  • Chang, Young-C.;Park, Chan-Koo;Jung, Kweon;Kikuchi, Shintaro
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.323-336
    • /
    • 2010
  • We evaluated the properties of a fixed-bed column reactor for high-concentration tetrachloroethylene (PCE) removal. The anaerobic bacterium Clostridium bifermentans DPH-1 was able to dechlorinate PCE to cis-1,2-dichloroethylene (cDCE) via trichloroethylene (TCE) at high rates in the monoculture biofilm of an upflow fixed-bed column reactor. The first-order reaction rate of C. bifermentans DPH-1 was relatively high at $0.006\;mg\;protein^{-1}{\cdot}l{\cdot}h^{-1}$, and comparable to rates obtained by others. When we gradually raised the influent PCE concentration from $30\;{\mu}M$ to $905\;{\mu}M$, the degree of PCE dechlorination rose to over 99% during the operation period of 2,000 h. In order to maintain efficiency of transformation of PCE in this reactor system, more than 6 h hydraulic retention time (HRT) is required. The maximum volumetric dechlorination rate of PCE was determined to be $1,100\;{\mu}mol{\cdot}d^{-1}l$ of reactor $volume^{-1}$, which is relatively high compared to rates reported previously. The results of this study indicate that the PCE removal performance of this fixed-bed reactor immobilized mono-culture is comparable to that of a fixed-bed reactor mixture culture system. Furthermore, our system has the major advantage of a rapid (5 days) start-up time for the reactor. The flow characteristics of this reactor are intermediate between those of the plug-flow and complete-mix systems. Biotransformation of PCE into innocuous compounds is desirable; however, unfortunately cDCE, which is itself toxic, was the main product of PCE dechlorination in this reactor system. In order to establish a system for complete detoxification of PCE, co-immobilization of C. bifermentans DPH-1 with other bacteria that degrade cDCE aerobically or anaerobically to ethene or ethane may be effective.

Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique

  • Kang, Seen-Young;Park, Jung-Hyun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.354-360
    • /
    • 2018
  • PURPOSE. To compare and analyze trueness and precision of provisional crowns made using stereolithography apparatus and subtractive technology. MATERIALS AND METHODS. Digital impressions were made using a master model and an intraoral scanner and the crowns were designed with CAD software; in total, 22 crowns were produced. After superimposing CAD design data and scan data using a 3D program, quantitative and qualitative data were obtained for analysis of trueness and precision. Statistical analysis was performed using normality test combined with Levene test for equal variance analysis and independent sample t-test. Type 1 error was set at 0.05. RESULTS. Trueness for the outer and inner surfaces of the SLA crown (SLAC) were $49.6{\pm}9.3{\mu}m$ and $22.5{\pm}5.1{\mu}m$, respectively, and those of the subtractive crown (SUBC) were $31.8{\pm}7.5{\mu}m$ and $14.6{\pm}1.2{\mu}m$, respectively. Precision values for the outer and inner surfaces of the SLAC were $18.7{\pm}6.2{\mu}m$ and $26.9{\pm}8.5{\mu}m$, and those of the SUBC were $25.4{\pm}3.1{\mu}m$ and $13.8{\pm}0.6{\mu}m$, respectively. Trueness values for the outer and inner surfaces of the SLAC and SUBC showed statistically significant differences (P<.001). Precision for the inner surface showed significance (P<.03), whereas that for the outer surface showed no significance (P<.58). CONCLUSION. The study demonstrates that provisional crowns produced by subtractive technology are superior to crowns fabricated by stereolithography in terms of accuracy.

Levels and Related Factors of Airborne Fungi in Microbial and Chemistry Laboratories in Universities (일부 대학교 미생물실험실 및 화학실험실에서의 진균 분포 및 관련인자)

  • Hwang, Sung-Ho;Jo, Hyun-Woo;Park, Dong-Uk;Yoon, Chung-Sik;Ryu, Kyong-Nam;Ha, Kwon-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The purpose of this study is to assess the level of fungi concentration in the university laboratories in Seoul, Korea, and to investigate factors contributing to these concentrations. The samples were taken from three spots in each laboratory; the top of sink, the center of laboratory, and the front of ventilation system, i.e fume hood at the chemical laboratory and clean bench/biosafety cabinet at the microbial laboratory. Air samples were collected using the single-stage Anderson sampler (Quick Take 30) at a flow rate of 28.3 l/min for 5 min on nutrient media in Petri-dishes located on the impactor. Fifty-two air samples were collected from 19 different laboratories (13 microbiology laboratories, 6 chemistry laboratories) in the university, and concentrations of airborne fungi showed no significant difference (p>0.05) between microbiology and chemistry laboratory, and also no significant difference at three locations (sink, center, front of ventilation system) in microbiology and chemistry laboratories. Average concentrations of fungi in 19 laboratories ranged from 7 to 459 cfu/$m^3$, with an overall Geometric Mean of 52 cfu/$m^3$. Airborne fungi concentrations of 6 samples (12 %) exceeded 150 cfu/$m^3$, the guideline of WHO. The ratios of Indoor/Outdoor for airborne fungi ranged from 0.2 to 4.8 (mean = 1.6). Related factors were measured such as relative humidity, temperature, and laboratory area. Temperature and laboratory area showed no significant relations to concentrations of airborne fungi except for relative humidity in the laboratory Concentrations of fungi were significant different (p<0.01) between rainy or cloudy and sunny. However, there was no significant difference between general ventilation and nongeneral ventilation.

Serum Testosterone Levels in Patients with Post-Traumatic Stress Disorder (외상 후 스트레스 장애 환자의 혈청 테스토스테론치)

  • Kim, Dong Su;Kim, Hae Jung;Bang, Yu Jin;Go, Chang Min;Chung, Moon Yong;Kang, Suk Hoon
    • Anxiety and mood
    • /
    • v.9 no.2
    • /
    • pp.106-112
    • /
    • 2013
  • Objective : Several reports have found abnormal levels of androgen in post-traumatic stress disorder (PTSD) patients. This abnormality in androgen is hypothesized to due to chronic psychological stress effects on the hypothalamic-pituitary-gonadal (HPG) system. The present study was conducted to estimate serum testosterone levels in PTSD patients in comparison with normal subjects. Methods : Seventy-five male Korean veterans of the Vietnam War volunteered for the study, of which eleven were excluded because of incomplete psychological assessment. To measure basal serum testosterone, blood samples were collected between 8.00 and 9.30 a.m. The clinician administered PTSD scale (CAPS), the structured clinical interview for DSM-IV (SCID), Hamilton Anxiety Rating Scale (HAM-A), Hamilton Rating Scale for Depression (HAM-D), Mini International Neuropsychiatric Interview Plus (Korean version of MINI-Plus), CES-K (Korean version of combat exposure scale). Results : The serum testosterone level of PTSD patients ($5.4{\pm}2.5ng/mL$) was higher than that of a control group ($3.1{\pm}1.7ng/mL$, p<0.001). Testosterone levels were significantly correlated with CAPS (r=.38, p<.01), HAM-A (r=.35, p<.01) and HAM-D (r=.28, p<.01) in all subjects. Conclusion : The results of the present study suggest that chronic psychological stress affects the HPG system.