• Title/Summary/Keyword: M-10 anchorage

Search Result 62, Processing Time 0.023 seconds

A strain-based wire breakage identification algorithm for unbonded PT tendons

  • Abdullah, A.B.M.;Rice, Jennifer A.;Hamilton, H.R.
    • Smart Structures and Systems
    • /
    • v.16 no.3
    • /
    • pp.415-433
    • /
    • 2015
  • Tendon failures in bonded post-tensioned bridges over the last two decades have motivated ongoing investigations on various aspects of unbonded tendons and their monitoring methods. Recent research shows that change of strain distribution in anchor heads can be useful in detecting wire breakage in unbonded construction. Based on this strain variation, this paper develops a damage detection model that enables an automated tendon monitoring system to identify and locate wire breaks. The first part of this paper presents an experimental program conducted to study the strain variation in anchor heads by generating wire breaks using a mechanical device. The program comprised three sets of tests with fully populated 19-strand anchor head and evaluated the levels of strain variation with number of wire breaks in different strands. The sensitivity of strain variation with wire breaks in circumferential and radial directions of anchor head in addition to the axial direction (parallel to the strand) were investigated and the measured axial strains were found to be the most sensitive. The second part of the paper focuses on formulating the wire breakage detection framework. A finite element model of the anchorage assembly was created to demonstrate the algorithm as well as to investigate the asymmetric strain distribution observed in experimental results. In addition, as almost inevitably encountered during tendon stressing, the effects of differential wedge seating on the proposed model have been analyzed. A sensitivity analysis has been performed at the end to assess the robustness of the model with random measurement errors.

Repeated Loading Test of Shear-Critical Reinforced Concrete Beams with Headed Shear Reinforcement (헤디드 바를 전단철근으로 사용한 철근콘크리트 보의 전단거동에 관한 반복하중 실험)

  • Kim, Young-Hoon;Lee, Joo-Ha;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.47-56
    • /
    • 2006
  • The repeated loading responses of four shear-critical reinforced concrete beams with two different shear span-to-depth ratios, were studied. One series of beams was reinforced using pairs of bundled stirrups with $90^{\circ}$ standard hooks, haying free end extensions of $6d_b$. The companion beams contained shear reinforcement made with larger diameter headed bars anchored with 50mm diameter circular heads. A single headed bar had the same area as a pair of bundled stirrups and hence the two series were comparable. The test results indicate that beams containing headed bar stirrups have a superior performance to companion beams containing bundled standard stirrups with improved ductility, larger energy absorption and enhanced post-peak load carrying capability. Due to splitting of the concrete cover and local crushing, the hooks of the standard stirrups opened resulting in loss of anchorage. In contrast, the headed bar stirrups did not lose their anchorage and hence were able to develop strain hardening and also served to delay buckling of the flexural compression steel. Excellent load-deflection predictions were obtained by reducing the tension stiffening to account for repeated load effects.

A Study on the Evaluation of Tensile Performance According to Pareral Jointing Methods of the Sheet Membrane Waterproofing System (방수시트의 평행접합방법에 따른 인장성능 평가연구)

  • Lee Jeoung-Yun;Oh Mi-Hyun;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.39-44
    • /
    • 2004
  • A heat and room temperature construction method of asphalt have been mainly applying to rooftop waterproofing in concrete structure, and the rest construction method are sheet, membrane and mortar waterproofing construction method. In particular, joint method in sheet waterproof method is as overlap joint which on being reinforced with fiber and tape, have been applying for job site to mechanical fix using protection disk and anchorage and metal ironwork on the end of sheet. These construction method cause cutting off joint of sheet as behavior of structure according to repairs of sheet itself and thermal conduct, outdoor air environment. In conclusion, we analyzed and examined the application of various sheets and piece ashes about superior 'I' joint which divide from one and the other sheet and progressed about joint construction method of fixing method for overlap.

  • PDF

Shear bond failure in composite slabs - a detailed experimental study

  • Chen, Shiming;Shi, Xiaoyu;Qiu, Zihao
    • Steel and Composite Structures
    • /
    • v.11 no.3
    • /
    • pp.233-250
    • /
    • 2011
  • An experimental study has been carried out to reveal the shear-bond failure mechanism of composite deck slabs. Thirteen full scale simply supported composite slabs are studied experimentally, with the influence parameters like span length, slab depth, shear span length and end anchorage provided by steel headed studs. A dozen of strain gauges and LVDTs are monitored to capture the strain distribution and variation of the composite slabs. Before the onset of shear-bond slip, the longitudinal shear forces along the span are deduced and found to be proportional to the vertical shear force in terms of the shear-bond strength in the m-k method. The test results are appraised using the current design procedures. Based on the partial shear-bond connection at the ultimate state, an improved method is proposed by introducing two reduction factors to assess the moment resistance of a composite deck slab. The new method has been validated and the results predicted by the revised method agree well with the test results.

Numerical method for the strength of two-dimensional concrete struts

  • Yun, Y.M.
    • Computers and Concrete
    • /
    • v.28 no.6
    • /
    • pp.621-634
    • /
    • 2021
  • For the reliable strut-and-tie model (STM) design of disturbed regions of concrete members, structural designers must accurately determine the strength of concrete struts to check the strength conditions of a selected STM el and the anchorage of reinforcing bars in nodal zones. In this study, the author proposed a consistent numerical method for strut strength, applicable to all two-dimensional STMs. The proposed method includes the effects of a biaxial stress state associated with tensile strains in reinforcing bars crossing a strut, deviation angle between strut orientation and compressive principal stress flow, and degree of confinement provided by reinforcement. The author examined the method's validity through the STM prediction of the ultimate strengths of 517 reinforced concrete (RC) deep beams, 24 RC panels, and 258 RC corbels, all tested to failure.

Optimization of Human Thrombopoietin Production in Insert Cells Using Baculovirus Expression System (베큘로 바이러스 발현 시스템에 의한 곤충세포에서의 인간 트롬보포이에틴 생산 최적화)

  • 고여욱;손미영;박상규;안혜경;박승국;박명환;양재명
    • KSBB Journal
    • /
    • v.13 no.2
    • /
    • pp.181-186
    • /
    • 1998
  • In order to obtain high-level production of recombinant human thrombopoietin (rhTPO) in insect cell line, HTI-TN-5B1-4 (TN5), conditions for optimal rhTPO expression such as multiplicity of infection (MOI), the cell density at infection, harvesting time and type of culture method as well as growth media were determined. When TN5 cells were cultured as anchorage-dependent state in 60-mm dish, cell density $2\times^6$ cells,MOI of 10 and Garvesting the culture media at 72 hr post-infection wrere the cinditions for highest rh TPO production. High production of rhTPO was also achieved by using EXPRESS FIVE serum free media rather than SF900II serum free media-1. Anchorage-dependent TN5 cells were adapted as a suspension culture when they were grown in the presence of heparin. TN5 cells were successfully cultured at 0.2 L scale in suspension culture without having aggregation. When TN5 cells were cultured as suspension state, cell density of $0.6\times10^6$ cells/mL, MOI of 1 and harvesting the culture media at 72 hr post-infection, gave the highest yield of rhTPO.

  • PDF

Parametric Study on the Structural Characteristics of Extradosed PSC Box Girder Bridges (매개변수해석을 통한 Extradosed PSC 박스 거더교의 구조특성 분석)

  • Chung, Jee-Seung;Jeon, Jun-Chang;Park, Jin-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.74-80
    • /
    • 2016
  • In this paper, structural characteristics for an extradosed prestressed concrete box girder bridge are investigated in terms of selective parameters. These parameters are mainly associated with the structural details of the extradosed bridge and derived from currently available literatures regarding previous design drawings. The analyses have been carried out using general-purpose structural analysis program, RM-Space Frame. The parameters evaluated for the present study represent the most salient features of the extradosed bridge and are as follows; 1) span length ratio(side-span length to center-span length), 2) boundary condition of girder, 3) height of pylon, 4) anchorage location of external cables and 5) girder stiffness. The analytical predictions indicate that span length ratio and pylon height are reasonably adequate in the range of 0.55 to 0.60 and $L_m/8$ to $L_m/12$ respectively for the bridge under consideration. Also, demonstrated is the boundary condition of girder, in which rigid-connection details give more efficiency than the continuous details. In addition, considering structural characteristics of the extradosed bridge, it is desirable that the girder stiffness should be determined by the stress range of external cables rather than bending moment of girder.

Investigation of Carcinogenic Potential of TCDD in the Human Breast Epithelial Cell line (사람의 유방상피세포에서 TCDD에 의한 발암성 연구)

  • 김정환;나혜경;서영준
    • Environmental Mutagens and Carcinogens
    • /
    • v.22 no.4
    • /
    • pp.312-318
    • /
    • 2002
  • Dioxin represents a group of halogenated aromatic hydrocarbons of which 2,3,7,8-tetrachlorod-ibenzo-p-dioxin (TCDD) is well known for its extremely toxic properties as well as ubiquitous presence in our environment and ecosystems. In order to better assess the carcinogenic mechanism of dioxin, we should utilize the reliable biomarkers that can precisely and correctly reflect multi-stage carcinogenesis. When MCF10A cells were exposed to TCDD (10 nM), expression of both CYP1A1 and CYP1B1 was induced in a time-related manner. The expression as well as activity of ornithine decarboxylase was transiently induced by TCDD treatment. In contrast, the induction of COX-2 that is implicated in carcinogenesis as well as inflammation, was not induced by TCDD. In another study, gap-junctional intercellular communication (GJIC) was attenuated by TCDD treatment as revealed by the dye-transfer assay. Based on these findings, TCDD has both tumor initiating and promoting potential in human breast epithelial cells in culture. Also, treatment of MCF10A cells with the carcinogen 7,12-dimethylbenz[a]anthracene plus TCDD resulted in malignant cell transformation as revealed by increased anchorage-independent growth of exposed cells. Additional studies may be necessary to assess the effects of TCDD on multi-stage carcinogenesis in vivo.

  • PDF

Influence of the shape of head anchors on the durability of reinforced concrete elements

  • Martinez-Echeverria, M. Jose;Gil-Martin, Luisa Maria;Montero, Jose Rodriguez;Hernandez-Montes, Enrique
    • Advances in concrete construction
    • /
    • v.10 no.1
    • /
    • pp.61-69
    • /
    • 2020
  • This paper looks into how the shape of headed bars may influence the durability of reinforced concrete structures. Nowadays the only heads used in site works are cylindrical in shape. An alternative shape of head is studied in this piece of work. The new head reduces the concentration of stresses and so the appearance of cracks. In this work durability is studied based on both, first cracking and failure mode. An experimental campaign of 12 specimens and finite element modelling are described. The specimens were subjected to an accelerated corrosion process using an electrical current supply. Direct current was impressed on the specimens until breaking. Test results and the results obtained from numerical models are presented. Results are presented in term of comparison between the two shapes of heads studied. It was shown that the shape of the head has a significant influence on durability of reinforced concrete structures with headed reinforcing bars.

Experimental Study on Flexural Behavior of RC Beams Strengthened with Prestressed CFRP Plate (CFRP판으로 프리스트레싱 보강한 RC 보의 휨거동에 관한 실험적 연구)

  • Han, Sang-Hoon;Hong, Ki-Nam;Kim, Hyung-Jin;Woo, Sang-Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2A
    • /
    • pp.301-310
    • /
    • 2006
  • Carbon fiber reinforced polymer (CRFP) materials are well suited to the rehabilitation of civil engineering structures due to their corrosion resistance, high strength to weight ratio and high stiffness to weight ratio. Their application in the field of the rehabilitation of concrete structures is increased due to the vast number of bridges and buildings in need of strengthening. However, RC members, strengthened with externally bonded CFRP plates, happened to collapse before reaching the expected design failure load. Therefore, it is necessary to develop the new strengthening method to overcome the problems of previous bonded strengthening method. This problems can be solved by prestressing the CFRP plate before bonding to the concrete. In this study, a total of 21 specimens of 3.3 m length were tested by the four point bending method after strengthening them with externally bonded CFRP plates. The CFRP plates were bonded without prestress and with various prestress levels ranging from 0.4% to 0.8% of CFRP plate strain. All specimen with end anchorage failed by a plate fracture regardless of the prestress levels while the specimen without end anchorage failed by the separation of the plate from the beam due to premature debonding. The cracking loads was proportionally related to the prestress levels, but the maximum loads of specimens strengthened with prestressed CFRP plates were insignificantly affected by the prestress levels.