• Title/Summary/Keyword: M&S system

Search Result 10,161, Processing Time 0.049 seconds

Modeling for M/C tools structure using system identification (System Identification을 이용한 공작기계구조물의 모델화에 관한 연구)

  • Hah, B.H.;Ro, S.H.;Kim, K.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.1
    • /
    • pp.142-146
    • /
    • 1993
  • The vibrations of the main spindle of the M/C tools are most important in the consideration of the dymamic performance of the M/C tools. In order to resolve and predict the dynamic behaviour of the main syindle it is necessary to have the mathematical model of the system. The system identification is the procedure to provide us with the mathematical model of the procedure of the system identification of the main spindle of the M/C tools to predict the dynamic behaviour of the machine and further to have the basis for the design of M/C tools.

  • PDF

Utilization of $CO_2$ Influenced by Windbreak in an Elevated Production System for Strawberry (딸기 고설재배시설에서의 이산화탄소 농도 유지를 위한 방풍막 설치 효과)

  • Kim, Y.-H.;Lee, I.-B.;Chun, Chang-Hoo;Hwang, H.-S.;Hong, S.-W.;Seo, I.-H.;Yoo, J.-I.;Bitog, Jessie P.;Kwon, K.-S.
    • Journal of Bio-Environment Control
    • /
    • v.18 no.1
    • /
    • pp.29-39
    • /
    • 2009
  • The influence of windbreak to minimize the ventilation velocity near the plant canopy of a greenhouse strawberry was thoroughly investigated using computational fluid dynamics (CFD) technology. Windbreaks were constructed surrounding the plant canopy to control ventilation and maintain the concentration of the supplied $CO_2$ from the soil surface close to the strawberry plants. The influence of no windbreak, 0.15 m and 0.30 m height windbreaks with varied air velocity of 0.5, 1.0 and 1.5 m/s were simulated in the study. The concentrations of supplied $CO_2$ within the plant canopy of were measured. To simplify the model, plants were not included in the final model. Considering 1.0m/s wind velocity which is the normal wind velocity of greenhouses, the concentrations of $CO_2$ were approximately 420, 580 and 653 ppm ($1{\times}10^{-9}kg/m^3$) for no windbreak, 0.15 and 0.30 m windbreak height, respectively. Considering that the maximum concentration of $CO_2$ for the strawberry plants was around 600-800 ppm, the 0.30 m windbreak height is highly recommended. This study revealed that the windbreak was very effective in preserving $CO_2$ gas within the plant canopy. More so, the study also proved that the CFD technique can be used to determine the concentration of $CO_2$ within the plant canopy for the plants consumption at any designed condition. For an in-depth application of this study, the plants as well as the different conditions for $CO_2$ utilization, etc. should be considered.

A Thermal Analysis for the Underground Power Transmission Cable by a Water Pipe Cooling Method with Trough in Tunnel (전력구트라프간접수냉방식에서의 지중송전케이블에 대한 열해석)

  • Park, Man-Heung
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.59-73
    • /
    • 1995
  • The thermal analysis is accomplished with the route for the underground power transmission system which adopts the water pipe cooling with trough in tunnel. As a result, in case of a cooling system based on a refrigerator, the optimum condition for the flow rate of cooling water and the air velocity are calculated as the $2{\sim}3{\ell}/s/pipe$ and $1{\sim}2m/s/fan$, respectively. On the other hand, in case of cooling tower the optimum condition for them are calculated as the $2{\sim}3{\ell}/s/pipe$ and 6 m/s/fan, respectively. But the cooling system based on a cooling tower has the problem of enlarging the size of cooling fan and suppressing the labor of operator in tunnel. Therefore, to meet all the cooling conditions for a given cooling section, the cooling system based on a refrigerator is more acceptable.

  • PDF

Relationships of the Lithium-Induced Growth Inhibition of C6 Rat Glioma Cell to Expression of the Insulin-like Growth Factor System Components (C6 Rat Glioma Cell에서 리튬에 의한 성장 억제와 Insulin-like Growth Factor System Components의 발현과의 관계)

  • Kim, I.A.;Jin, E.J.;Cho, E.J.;Sohn, S.H.;Lee, C.Y.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.4
    • /
    • pp.563-570
    • /
    • 2004
  • The insulin-like growth factor(IGF) system, consisting of IGFs-I and -II ligands and their receptors and six IGF-binding proteins(IGFBPs), plays an important role in survival, proliferation and differentiation of a variety of cell types. Lithium is a known modulator of survival and proliferation of many cell types in vitro. The present study was undertaken to investigate the relationship between LiCI-induced changes in cell survival and growth and the expression of the IGF system components in C6 rat glioma cell line which, besides IGF-I and its receptor, is known to express IGFBP-3 as its major IGF carrier. When C6 cells were cultured for 24h in the absence or presence of 2mM or 5mM LiCl in a 10% serwn-containing medium, the viability and the number of cells were not affected by added lithium. In 72-h culture, however, C6 cells clearly exhibited a dose-dependent response to added LiCl. The cells cultured for 72h in the presence of 0, 2mM and 5mM LiCl exhibited a typical mitotic, a growth-arrested and an apoptotic appearances, respectively. Moreover, the apoptotic cells were accompanied by reduced expression of IGF-I, IGF-I receptor and IGFBP-3 as examined by semi-quantitative reverse transcription-polymerase chain reaction. Interestingly, blockade of IGFBP-3 mRNA translation by addition of 101${\mu}M$ IGFBP-3 anti-sense oligodeoxyribonucleotide in serum-free, 24-h culture resulted in a decrease in the number of cells as well as relative abundance of the target mRNA. In summary, results suggest that the cytotoxic effect of lithium in C6 cell is likely to be mediated, in part, by suppression by this agent of the expression of the IGF system components. In this regard, IGFBP-3 may play at least a 'permissive' role in normal proliferation of this cell.

Interior Design Graduate Education System and Degrees in Korea and the U.S. (한국과 미국의 실내디자인학 대학원 현황과 학위제도 특성)

  • Shim, Eun-Ju
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.133-141
    • /
    • 2014
  • Graduate education in general means nurturing scholars who are capable of research that adds to the 'body of knowledge' and educators in the higher education system. Therefore 'discovering' new knowledge has always been a major role of graduate schools. However, interior design is a special field that 'application' can also produce new knowledge and therefore a wider understanding of scholarship is needed especially in the graduate level education. The purpose of this paper is to understand Interior Design graduate education system in the United States in order to develop issues that need to be discusses and addressed in Korea. Therefore, this paper first examines meanings of graduate degrees in general and current situation of Interior degrees offered in Korea. Then investigates the different types of graduate degrees in the U.S. such as post-professional degrees, first-professional degrees, and differences in general degree(M.A., M.S.) and professional degrees (M.F.A., M.I.D.). The researcher has used websites of each school and information lists of degrees offered by KIID and IDEC that serves as the main educators council in each countries. The characteristics of graduate degrees in America can be described as a structured system based on variety, flexibility, and distinction. For instance, M.F.A means a professional degree that is focused on building theory based project abilities, longer period to study but counted as a terminal in the field. However, in Korea even though the title of the degrees may differ there is not much difference shown in the educational contents. Therefore issues such as developing a more universal and international degree system, flexible and selective educational road-map, mutual understanding and unified system between various organizations for better graduate education system are proposed. Moreover, hope to start a discourse on defining scholarship and professionalism in the field of Interior Design.

Collection characteristics of wet-type multi-staged impaction system for air pollutants removal of marine diesel engines (박용디젤기관의 대기오염 저감을 위한 습식 다단 임팩션 시스템의 집진특성)

  • YOA, Seok-Jun;KWON, Jun-Hyeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.3
    • /
    • pp.248-256
    • /
    • 2016
  • The main purpose of this paper was to analyze the removal characteristics of gas/particulate phase pollutants for the present system. Experimentally, we performed to estimate the pressure drop and air pollution removal efficiency with physical variables such as stage number, tube velocity, tube diameter, water spray ($NH_4OH$), and so on. It was concluded that the pressure drop was shown below $111mmH_2O$ lower than that of the existing scrubber (centrifugal spray chamber, over 200 mmAq) at inlet velocity 3.46 m/s and 5 stage. The particular removal efficiency of this system was to be significantly higher at 99.8% in comparison with that of the existing scrubber for 5 stage, inlet velocity 3.46 m/s and $NH_4OH$ (aq) 300 mL/min. It was estimated that the removal efficiencies of $SO_2$ and $NO_2$ were 80% and 70% at system inlet velocity 2.07 m/s and $NH_4OH$ (aq) 300 mL/min respectively. Additionally, the present collection system was to be considered as an effective compact system for simultaneous removal of air pollutants (gas/particulate) due to much higher removal efficiency and appropriate pressure drop without a demister.

A Study of a Sunlight Collector System and Its Application (태양광 채광시스템의 조명 적용에 관한 연구)

  • 박준석;어익수;여인선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.1-6
    • /
    • 2001
  • In this paper, it is analysed the spectrum of optical fiber output through the sunlight collector system. As the result of the analysis, the sunlight collector system's UV distribution is lower then the sunlight'UV distribution. Also, the lighting environments under the optical fiber bundles are predicted when applied to the minimum workroom's(6${\times}$6${\times}$2.3[m]) interior lighting by using a lighting design program. In case of optical filer output\`s hight of 1.3[m], the illuminance value over 500[lx] in the area 50${\times}$50[cm] was achieved. As the result its feasibility as an interior lighting source shows no serious problem except the system cost.

  • PDF

PDA Based Audiometric System and its Database Structure (PDA 기반의 청력 검사 시스템 및 데이터베이스 구성)

  • Kim K. S.;Lee J.H;Shin S.W;Yoon T.H;Lee S.M
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.1
    • /
    • pp.42-44
    • /
    • 2006
  • In this paper, we tried to implement a PDA (Personal Digital Assistant)-based audiometric system to test hearing disorder. Due to the inherent handy nature of PDA system, our hearing test system can be easily performed in an user's local environment and consequently the measured audiometric data can be stored and queryed locally via a built-in PDA database system.

A Study on the Characteristics of an Optical Sensor Linear Fire Detection System with Miniature Model Fire Experiment (축소 모형실험을 통한 광센서 선형 화재 감지 시스템의 특성에 관한 연구)

  • Kim, Dong-Eun;Kim, Si-Kuk;Lee, Young-Sin;Lee, Chun-Ha;Lim, Woo-Sup
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.19-26
    • /
    • 2016
  • In this study, we conducted a low temperature operating test and miniature tunnel model test to study the fire detection capability and properties of an early fire detection system using an optical sensor linear detector that can be installed in harsh environments such as tunnel or utility-pipe conduits which are becoming the major and national infrastructure facilities. The test showed that the optical sensor linear detector was the only one functioned properly among five thermal detectors installed at a low temperature of $-20^{\circ}C$ for 5 days. To study were analyzed adaptability of optical sensor linear detector in the windy tunnel, the operating properties of the optical sensor linear detector when the wind velocity was varied between 0 m/s and 1 m/s in a miniature tunnel model. The temperature change was high when the wind velocity was 0 m/s.