• Title/Summary/Keyword: M&S Technique

Search Result 2,421, Processing Time 0.043 seconds

Evaluation of Usefulness of an m-DIXON Technique during an Abdomen MRI Examination : A Comparison with an e-THRIVE Technique (복부 MRI검사에서 m-DIXON기법의 유용성 평가: e-THRIVE기법과 비교 분석)

  • Lee, Bo-Woo;Park, Myung-Cheol;Lee, Jin-Hoi;Kim, Ki-Jin;Bae, Seok-Hwan
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.385-390
    • /
    • 2014
  • This research is conducted to identify whether an m-DIXON technique which is useful for an abdomen MRI examination compared with an existing e-THRIVE technique is a clinically useful or not. There was evaluated quantitative and qualitative to 84 subjects who had abdomen MRI exam due to their liver disease were conducted during a period from September in 2013 to February in 2014. First of all the quantitative evaluation, the m-DIXON technique's SNR was $90.42{\pm}16.90$ and the e-THRIVE technique was $60.42{\pm}11.54$ and the m-DIXON technique's CNR was $52.38{\pm}22.58$ and the e-THRIVE technique was $46.31{\pm}20.25$. Secondly in the qualitative evaluation, the m-DIXON technique's image quality was $4.06{\pm}0.34$, a artifact was $3.64{\pm}0.22$, and fat suppression was $4.16{\pm}0.15$, the e-THRIVE technique's image quality was $3.14{\pm}0.35$, a artifact was $3.06{\pm}0.38$, fat suppression was $3.14{\pm}0.30$. In conclusion, m-DIXON technique for abdomen MRI examination showed superiority over both SNR as a quantitative anaylsis, CNR and a qualitative analysis.

Comparative Study on the Effectiveness of Modified Kato's Cellophane Thick Smear and Stoll's Dilution Egg Counting Technique for Quantitative Fecal Examination of Helminth Eggs (윤충란 정량검사를 위한 Stoll 희석충란계산법과 Kato 후층도말변법의 비교)

  • 홍성종;우호춘
    • Parasites, Hosts and Diseases
    • /
    • v.30 no.2
    • /
    • pp.141-146
    • /
    • 1992
  • A total of 197 fecal specimens was prepared for quantitative examination of helminth eggs by modified Kato's cellophane thick smear (M.C.T.S.) and Stoll's dilution egg counting technique (D.E,C.T.). The comparative effectiveness of two techniques was evaluated and conversion function was deduced. The average time required for the microscopic examination on one slide by M.C.T.S. was 12.6 minutes and that of D.E.C.T. was 14.6 minutes. M.C.T.S. showed lower false negative rate than D.E.C.T in light worm burden cases. Functions to convert the counts obtained by M.C.T.S. to E.P.G. by Stoll's dilution egg counting technique were $47.86{\times}10^{0.87{\;}logM.C.T.S.},{\;}$ in A. lumbricoides, $41.69{\times}10^{0.82{\;}logM.C.T.S.}$ in T. trichiura and $63.10{\times}10^{0.85{\;}logM.C.T.S.}$ in C. sinensis. It was suggested M.C.T.S. be better than D.E.C.T. for the quantitative examination of intestinal helminthiases such as A. lumbricoides, T. trichiura, and C. sinensis infections even in the cases with low worm burden.

  • PDF

Development, validation and implementation of multiple radioactive particle tracking technique

  • Mehul S. Vesvikar;Thaar M. Aljuwaya;Mahmoud M. Taha;Muthanna H. Al-Dahhan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4213-4227
    • /
    • 2023
  • Computer Automated Radioactive Particle Tracking (CARPT) technique has been successfully utilized to measure the velocity profiles and mixing parameters in different multiphase flow systems where a single radioactive tracer is used to track the tagged phase. However, many industrial processes use a wide range of particles with different physical properties where solid particles could vary in size, shape and density. For application in such systems, the capability of current single tracer CARPT can be advanced to track more than one particle simultaneously. Tracking multiple particles will thus enable to track the motion of particles of different size shape and density, determine segregation of particles and probing particle interactions. In this work, a newly developed Multiple Radioactive Particle Tracking technique (M-RPT) used to track two different radioactive tracers is demonstrated. The M-RPT electronics was developed that can differentiate between gamma counts obtained from the different radioactive tracers on the basis of their gamma energy peak. The M-RPT technique was validated by tracking two stationary and moving particles (Sc-46 and Co-60) simultaneously. Finally, M-RPT was successfully implemented to track two phases, solid and liquid, simultaneously in three phase slurry bubble column reactors.

Synthesis of Mullite Powders by the Geopolymer Technique (Geopolymer Technique에 의한 Mullite 분말의 합성)

  • Son, Se-Gu;Lee, Ji-Hyeon;Lee, Jeong-Mi;Kim, Young-Do
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.5
    • /
    • pp.303-308
    • /
    • 2008
  • Mullite precursors were synthesized with aluminosilicate gels from mixture of aluminum nitrate and sodium orthosilicate by the geopolymer technique at ambient temperature. Then, the gel was heat-treated in air up to $1200^{\circ}C$ at intervals of $100^{\circ}C$. Raw and heat-treated gels were characterized by TG-DTA, XRD, FTIR, $^{29}Si$ MAS-NMR, TEM. The result to examine the crystallization of behavior though DTA, the synthesized precursors were crystallized in the temperature range from $950^{\circ}C$ to $1050^{\circ}C$. The XRD results showed that the gel compositions were begun to crystallize at various temperature. Also, it was found that the precursors of M-4 begun to crystallize at about $950^{\circ}C$. The M-4 XRD peaks were characterized better than $M-1{\sim}M-3$ at $1000^{\circ}C$. The formation temperature of mullite in this study is much lower than that of previous sol-gel methods, which crystallized at up of $1200^{\circ}C$. TEM investigations revealed that the sample with 10 nm particle size was obtained via heat-treated at $1000^{\circ}C$ for M-4.

Marine Accident Cause Investigation using M&S System (고도 정밀 M&S 시스템을 이용한 해난사고 원인규명)

  • Lee, Sang-Gab
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.06a
    • /
    • pp.36-37
    • /
    • 2014
  • It is necessary to develop highly sophisticated Modeling & Simulation (M&S) system for the scientific investigation of marine accident causes and for the systematic reproduction of accidental damage procedure. To ensure an accurate and reasonable prediction of marine accidental causes, such as collision, grounding and flooding, full-scale ship M&S simulations would be the best approach using hydrocode, such as LS-DYNA code, with its Fluid-Structure Interaction (FSI) analysis technique. The objectivity of this paper is to present three full-scale ship collision, grounding and flooding simulation results of marine accidents, and to show the possibility of the scientific investigation of marine accident causes using highly sophisticated M&S system.

  • PDF

The Development of Torpedo Defense Experimental Technique based on M&S (M&S 기반 어뢰방어전 모의실험 기술 구현)

  • Nah, Young-In;Lee, Sim-Yong;Yoon, Han-Saem
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.818-823
    • /
    • 2010
  • Exploiting models and simulations are encouraged among the defense acquisition society, as now enforced by the Defense Aquisition Program Administration's regulations. They are useful and, sometimes, inevitable especially in an earlier phase of system development. Computer-simulation-based experimentation technique for the system operational performance analysis for a torpedo defense system is introduced in this paper. Problem definition for the torpedo defense system analysis and engineering efforts for models and simulations development are presented here, including defining measures of performance and effectiveness for the torpedo defense system, conceptual modeling for torpedo engagement and defense simulation, design of experimentation, design of simulator and experimentor, and hardware and software implementation of an analysis support tool - a system operations demonstration and experimentation simulator.

A 2 GHz 20 dBm IIP3 Low-Power CMOS LNA with Modified DS Linearization Technique

  • Rastegar, Habib;Lim, Jae-Hwan;Ryu, Jee-Youl
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.443-450
    • /
    • 2016
  • The linearization technique for low noise amplifier (LNA) has been implemented in standard $0.18-{\mu}m$ BiCMOS process. The MOS-BJT derivative superposition (MBDS) technique exploits a parallel LC tank in the emitter of bipolar transistor to reduce the second-order non-linear coefficient ($g_{m2}$) which limits the enhancement of linearity performance. Two feedback capacitances are used in parallel with the base-collector and gate-drain capacitances to adjust the phase of third-order non-linear coefficients of bipolar and MOS transistors to improve the linearity characteristics. The MBDS technique is also employed cascode configuration to further reduce the second-order nonlinear coefficient. The proposed LNA exhibits gain of 9.3 dB and noise figure (NF) of 2.3 dB at 2 GHz. The excellent IIP3 of 20 dBm and low-power power consumption of 5.14 mW at the power supply of 1 V are achieved. The input return loss ($S_{11}$) and output return loss ($S_{22}$) are kept below - 10 dB and -15 dB, respectively. The reverse isolation ($S_{12}$) is better than -50 dB.

MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES (가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화)

  • Han, Seung-Ryul;Min, Kyung-San;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

A 6bit 800MSample/s A/D Converter Design for Hard Disk Drive Read Channel (하드디스크 드라이브 읽기 채널용 6bit 800MSample/s 아날로그/디지털 변환기의 설계)

  • 정대영;장흥석;신경민;정강민
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.164-167
    • /
    • 2000
  • This paper introduces the design of high-speed analog-to-digital converter for hard disk drive (HDD) read channel. This is based on autozero technique for low-error rate, and Double Speed Dual ADC(DSDA) technique lot efficiently increasing the conversion speed of A/D converter. This An is designed by 6bit resolution, 800M sample/s maximum conversion rate, 390㎽ power dissipation, one clock cycle latency in 0.65 $\mu\textrm{m}$ CMOS technology.

  • PDF

[ $PFC^{3D}$ ] Modeling of Stress Wave Propagation Using The Hopkinson's Effect ($PFC^{3D}$ 상에서의 홉킨슨 효과를 이용한 응력파의 전파모델링)

  • Choi Byung-Hee;Ryu Chang-ha
    • Explosives and Blasting
    • /
    • v.23 no.3
    • /
    • pp.27-42
    • /
    • 2005
  • An explosion modeling technique was developed by using the spherical discrete element code, $PFC^{3D}$, which can be used to model the dynamic stress wave propagation phenomenon. The modeling technique is simply based on an idea that the explosion pressure should be applied to a $PFC^{3D}$ particle assembly not in the form of an external force (body force), but in the form of a contact force (surface force). The stress wave propagation modeling was conducted by simulating the experimental approach based on the Hopkinson's effect combined with the spatting phenomenon that had previously been developed to determine the dynamic tensile strength of Inada granite. As a result, the stress wave velocity obtained by the proposed modeling technique was 4167 m/s, which is merely $3\%$ lower than the actual wave velocity of 4300 m/s for an Inada granite.