• 제목/요약/키워드: M&C2017

검색결과 1,223건 처리시간 0.028초

BESSEL MULTIPLIERS AND APPROXIMATE DUALS IN HILBERT C -MODULES

  • Azandaryani, Morteza Mirzaee
    • 대한수학회지
    • /
    • 제54권4호
    • /
    • pp.1063-1079
    • /
    • 2017
  • Two standard Bessel sequences in a Hilbert $C^*$-module are approximately duals if the distance (with respect to the norm) between the identity operator on the Hilbert $C^*$-module and the operator constructed by the composition of the synthesis and analysis operators of these Bessel sequences is strictly less than one. In this paper, we introduce (a, m)-approximate duality using the distance between the identity operator and the operator defined by multiplying the Bessel multiplier with symbol m by an element a in the center of the $C^*$-algebra. We show that approximate duals are special cases of (a, m)-approximate duals and we generalize some of the important results obtained for approximate duals to (a, m)-approximate duals. Especially we study perturbations of (a, m)-approximate duals and (a, m)-approximate duals of modular Riesz bases.

이종입자 강화 SiC/Al7075 금속복합재료의 압축특성 및 마모특성 연구 (Mechanical Properties and Wear Performance of the Al7075 Composites Reinforced with Bimodal Sized SiC Particles)

  • 이동현;조승찬;김양도;이상관;이상복;조일국
    • Composites Research
    • /
    • 제30권5호
    • /
    • pp.310-315
    • /
    • 2017
  • 본 연구에서는 액상가압공정을 통해 고체적율의 SiC 입자가 균일 분산된 알루미늄 금속복합재료를 제조하고, 미세조직, 기계적 특성 및 내마모 특성에 대해 분석하였다. 입자크기가 다른 이종 SiC 입자가 약 60 vol.% 이상의 체적율로 균일하게 분산된 SiC/Al7075 복합재료는 단일 SiC 입자로 강화된 복합재료에 비해 체적율이 약 12% 이상 높았으며 압축강도가 200 MPa 이상 증가하였다. 내마모시험 결과 이종 SiC 입자 금속복합재료의 경우 마모너비와 깊이가 각각 $285.1{\mu}m$, $0.45{\mu}m$이며, 마찰계수는 0.16으로 내마모 특성이 가장 우수하였다.

Fracture toughness of high performance concrete subjected to elevated temperatures Part 2 The effects of heating rate, exposure time and cooling rate

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • 제5권5호
    • /
    • pp.513-537
    • /
    • 2017
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was investigated by conducting three-point bending tests on a total of 240 notched beams of $500mm{\times}100mm{\times}100mm$ subjected to heating temperatures up to $450^{\circ}C$ with exposure times up to 16 hours and various heating and cooling rates. For a heating rate of $3^{\circ}C/min$, $K_{IC}$ for the hot concrete sustained a monotonic decrease trend with the increasing heating temperature and exposure time, from $1.389MN/m^{1.5}$ at room temperature to $0.942MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.906MN/m^{1.5}$ for 8-hour exposure time and $0.866MN/m^{1.5}$ for 16-hour exposure time. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and then rapidly down to $0.869MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.812MN/m^{1.5}$ for 8-hour exposure time and $0.771MN/m^{1.5}$ for 16-hour exposure time. In general, the $K_{IC}$ values for the hot concrete up to $200^{\circ}C$ were larger than those for the cold concrete, and an inverse trend was observed thereafter. The increase in heating rate slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.893MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.839MN/m^{1.5}$ for $10^{\circ}C/min$ for the hot concrete and from $0.792MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.743MN/m^{1.5}$ for $10^{\circ}C/min$ for the cold concrete after an exposure time of 16 hours. The increase in cooling rate also slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.771MN/m^{1.5}$ for slow cooling to $0.739MN/m^{1.5}$ for fast cooling after an exposure time of 16 hours. The fracture energy-based fracture toughness $K_{IC}$' was also assessed, and similar decrease trends with the heating temperature and exposure time existed for both hot and cold concretes. The relationships of two fracture toughness parameters with the weight loss and the modulus of rapture were also evaluated.

13C NMR-Study of 1,1-Dipotassio-2,3,4,5-Tetraphenyl-1-Silacyclopentadienide Dianion [SiC4Ph4] 2-·2[K+ ] and 1,1-Dipotassio-2,3,4,5-Tetraphenyl-1- Germacyclopentadienide Dianion [GeC4Ph4] 2-·2[K+ ]

  • Hong, Jang-Hwan
    • 통합자연과학논문집
    • /
    • 제10권3호
    • /
    • pp.131-136
    • /
    • 2017
  • The chemical shifts in the $^{13}C$ NMR spectra of 2,3,4,5-tetraphenyl-1-silacyclopentdienide dianion $[SiC_4Ph_4]^{2-}{\cdot}2[K^+]$ (3) and 2,3,4,5-tetraphenyl-1-germacyclopentdienide dianion $[GeC_4Ph_4]^{2-}{\cdot}2[K^+]$ (4) were compared to those of $[SiC_4Ph_4]^{2-}{\cdot}2[Li^+]$ (5), $[SiC_4Ph_4]^{2-}{\cdot}2[Na^+]$ (6), and $[GeC_4Ph_4]^{2-}{\cdot}2[Li^+]$ (7). The average polarizations in two phenyl groups of two potassium salts are decreased over 15% to 20% comparing to those of the lithium salts and sodium salt {$[EC_4Ph_4]^{2-}{\cdot}2[M^+]$ (E=Si, Ge, M=Li, Na) due to the effect of the counter potassium cation.

가을철 교통조건에 따른 가로공간 열확산 분포 영향 (Effect of Thermal Diffusion on Autumn Traffic in Street Space)

  • 윤용한;김정호
    • 한국환경과학회지
    • /
    • 제26권4호
    • /
    • pp.467-481
    • /
    • 2017
  • This study sought to determine the changes in weather conditions in urban streets, along with conditions of traffic and roads in urban areas. The variations in weather conditions depending on traffic differed according to distance. First, the temperature difference measured by traffic results is as follows: T1 point $1.03^{\circ}C$, T2 point $1.04^{\circ}C$, T3 point $0.9^{\circ}C$, T4 point $1.01^{\circ}C$, and T5 point $0.31^{\circ}C$. The average difference between the measured temperatures by the point of measurement was $0.86^{\circ}C$. The changes in wind velocity according to traffic volume results of the measurements is T1 point 1.32 m/s, T2 point 0.80 m/s, T3 point 0.29 m/s, T4 point 0.04 m/s, and T5 point 0.09 m/s. The difference between the average wind speeds was 0.51 m/s and traffic jams caused substantial differences in distance. The relative humidity tended to be inversely proportional to temperature. The measurements results ares T1 point 2.29%, T2 point 2.67%, T3 point 2.47%, T4 point 2.16%, and T5 point 0.91% The difference between the average relative humidity was 7.3%. In case of independent sampling T test according to traffic volume, changes in wind velocity and temperature were directly proportional to the level of statistical significance(p<0.01). On the other hand, relative humidity tended to be inversely proportional; however, there was no statistical significance.

원료의약품 분진의 폭발 위험성 평가 (Explosion Hazard Assessment of Pharmaceutical Raw Materials Powders)

  • 이주엽;이근원;박상용;한인수
    • Korean Chemical Engineering Research
    • /
    • 제55권5호
    • /
    • pp.600-608
    • /
    • 2017
  • 산업현장에서 취급되거나 가공되는 원료의약품 분진의 폭발 위험성은 항상 존재하며, 이로 인한 폭발사고가 자주 발생되고 있다. 본 연구에서는 원료의약품 시료 3종의 분진폭발특성을 측정하였다. 주요 폭발특성 측정값은 록소프로펜산은 평균 입경이 $5.31{\mu}m$이며, $P_{max}$는 8.4 bar, 최소점화에너지는 1 mJ < MIE < 3 mJ이며 최소점화온도는 $550^{\circ}C$이다. 클로피도그렐 캄포르술폰산염은 평균 입경이 $95.63{\mu}m$이며, $P_{max}$는 7.9 bar, 최소점화에너지는 30 mJ < MIE < 100 mJ이며 최소점화온도는 $510^{\circ}C$이었다. 리팜피신은 평균 입경이 $26.48{\mu}m$이며 $P_{max}$는 7.9 bar, 최소점화에너지는 1 mJ < MIE < 3 mJ이며 최소점화온도는 $470^{\circ}C$로 나타났다. 이들 값을 적용하여 폭연지수($K_{st}$)와 폭발지수(EI)의 폭발위험등급을 구하고, 원료의약품 분진의 폭발 위험성을 비교 검토하였다. 그 결과 폭발 위험성은 록소프로펜산과 리팜피신의 폭발등급은 St 2이고 폭발위험등급은 severe이며, 클로피도그렐 캄포르술폰산염의 폭발등급은 St 1이고 폭발위험등급은 strong으로 나타났다.

CVD-SiC 소재의 가공 특성에 관한 연구 (A Study on the Machining Characteristics of CVD-SiC)

  • 박휘근;이원석;강동원;박인승;이종찬
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.40-46
    • /
    • 2017
  • A plasma gas control apparatus for semiconductor plasma etching processes securely holds a cathode for forming a plasma, confines the plasma during the plasma etching process, and discharges gas after etching. It is a key part of the etching process. With the advancement of semiconductor technology, there is increasing interest in parts for semiconductor manufacturing that directly affect wafers. Accordingly, in order to replace the plasma gas control device with a CVD-SiC material superior in mechanical properties to existing SiCs (Sintered-SiC, RB-SiC), a study on the grinding characteristics of CVD-SiC was carried out. It is confirmed that the optimal grinding condition was obtained when the result table feed rate was 2 m/min and the infeed depth was $5{\mu}m$.

The Comparison of Clinical Variables in Two Classifications: GOLD 2017 Combined Assessment and Spirometric Stage of Chronic Obstructive Pulmonary Disease

  • Candemir, Ipek;Ergun, Pinar;Kaymaz, Dicle;Tasdemir, Filiz;Egesel, Nurcan
    • Tuberculosis and Respiratory Diseases
    • /
    • 제81권4호
    • /
    • pp.281-288
    • /
    • 2018
  • Background: There are limited number of studies that investigate clinical variables instead of chronic obstructive lung disease (COPD) management according to Global Initiative for Chronic Obstructive Lung Disease (GOLD) 2017 classification. The aim of the study was to investigate whether there was a difference between GOLD 2017 classification and spirometric stage in clinical variables in patients with COPD. The data of 427 male patients with stable COPD were investigated retrospectively. Methods: Patients were allocated into combined assessment of GOLD 2017 and spirometric stage. Age, amount of smoking, pulmonary function, modified Medical Research Council (mMRC), incremental shuttle walk test (ISWT), Hospital Anxiety-Depression Scale (HADS), St. George's Respiratory Questionnaire (SGRQ), body mass index (BMI), and fat free mass index (FFMI) were recorded. Results: Seventy-three (17%) patients were in group A, 103 (24%) constituted group B, 38 (9%) were included in group C, and 213 (50%) comprised group D according to the combined assessment of GOLD 2017. Twenty-three patients (5%) were in stage 1, 95 (22%) were in stage 2, 149 (35%) were in stage 3, and 160 (38%) were in stage 4 according to spirometric stage. According to GOLD 2017, age, amount of smoking, mMRC, BMI, FFMI, SGRQ, HADS, forced vital capacity, forced expiratory volume in 1 second ($FEV_1$), and ISWT were significantly different between groups. Ages, amount of smoking, FFMI, BMI, HADS of group A were different from B and D. Smiliar values of $FEV_1$ were found in A-C and B-D. A and C had smiliar ISWT. According to spirometric stage, BMI, FFMI of stage 4 were statistically different. mMRC, ISWT, and SGRQ of stages 3 and 4 were different from other stages, amongst themselves. $FEV_1$ was correlated with mMRC, SGRQ, anxiety scores, BMI, FFMI, and ISWT. Conclusion: This study showed that the GOLD ABCD classification might not represent the severity of COPD sufficiently well in terms of lung function or exercise capacity. The combination of both spirometric stage and combined assessment of GOLD 2017 is important, especially for estimating clinical variables.

충적대수층 계간축열 냉난방 시스템의 온실 난방 효과 (Effects of the Cooling and Heating System with Seasonal Thermal Storage in Alluvial Aquifer on Greenhouse Heating)

  • 문종필;강금춘;김형권;이태석;오성식;진병옥
    • 한국농공학회논문집
    • /
    • 제59권6호
    • /
    • pp.127-135
    • /
    • 2017
  • In this study, a cold well and a warm one with the distance of 100 m were installed in the alluvial aquifer. Groundwater used as the heat and the cold source of heat pump was designed to flow into the warm and the cold well with a diameter of 200 mm. In order to increase the heat and cold storage in aquifer, six auxiliary wells with the diameter of 50 mm and the depth of 30 m were installed at an interval of 5 m from the main well. Also, heat pump 50 RT, the thermal tank $40m^3$, and a remote control and monitoring system were installed in three single-span greenhouses ($2,100m^2$) for growing tomato in Buyeo, Chungcheongnam-do. According to the aquifer heat storage test which had been conducted from Aug. 31 to Sep. 22, 2016, warm water of $850m^3$ was found to flow into warm well. The temperature of the injected water was $30^{\circ}C$ (intake temperature : $15^{\circ}C$), and the heat of 12.8 Gcal was stored. The greenhouse heating test in winter had been conducted from Nov. 21, 2016 to Apr. 30, 2017. On Nov. 21, 2016 when heating greenhouse started, the aquifer temperature of the warm well was $18.5^{\circ}C$. The COP for heating with water source at $18.5^{\circ}C$ was 3.8. The intake water temperature of warm well was gradually lowered to the temperature of $15^{\circ}C$ on Jan. 2, 2017 and the heat pump COP was measured to be 3.2 at that time. As a result, the heat pump COP was improved by 18 %. and retrieval heat was 8 Gcal, the retrieval rate of heat stored in aquifer was estimated at 63 %.

Investigations of Temperature Effect on the Conduction Mechanism of Electrical Conductivity of Copolymer/Carbon Black Composite

  • El Hasnaoui, M.;Kreit, L.;Costa, L.C.;Achour, M.E.
    • Applied Microscopy
    • /
    • 제47권3호
    • /
    • pp.121-125
    • /
    • 2017
  • This study deals the prediction of temperature effect on low-frequency dispersion of alternating current (AC) conductivity spectra of composite materials based on copolymer reinforced with carbon black (CB) particles. A sample of ethylene butylacrylate loaded with 13% of CB particles were prepared and investigated using the impedance spectroscopy representation in the frequency range from 40 Hz to 0.1 MHz and temperature range from $20^{\circ}C$ to $125^{\circ}C$. The dielectric constant, ${\varepsilon}^{\prime}$, and dielectric losses, ${\varepsilon}^{{\prime}{\prime}}$, were found to decrease with increasing frequency. The frequency dependence of the AC conductivity follows the universal power law with a large deviation in the high frequency region, the positive temperature coefficient in resistivity effect has been observed below the melting temperature which makes this composite potentially remarkable for industrial applications.