• Title/Summary/Keyword: Luminance Measurement

Search Result 121, Processing Time 0.028 seconds

The Study on Characteristics of Green Organic Light Emitting Device with Transparency Conductive Oxide Electrodes (투명전도성 산화물 전극에 따른 Green OLED의 특성연구)

  • Ki, Hyun-Chul;Kim, Seon-Hoon;Kim, Hwe-Jong;Kim, Sang-Gi;Choi, Young-Sung;Hong, Kyung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.615-618
    • /
    • 2009
  • In order to apply for transparent conductive oxide(TCO), we deposited ZnO thin film on the glass at room temperature by RF magnetron sputtering method. Deposition conditions for low resistivity were optimized in our previous studies. Under the deposition condition with the RF power of 800 [W]. Sheet resistance and surface roughness of ITO and ZnO thin film were measured by Hall-effect measurement system and AFM, respectively. The sheet resistance of ITO and ZnO thin film were 7.290 [$\Omega$] and 4.882 [$\Omega$], respectively. and surface roughness were 3.634 [nm] and 0.491 [nm], respectively. Green OLED was fabricated with the structure of TPD(400 [$\AA$])/Alq3(600 [$\AA$])/LiF(5 [$\AA$])/Al(1200 [$\AA$]). Turn-on voltage of green OLED applied ITO was 7 [V] and luminance was 7,371 [$cd/m^2$]. And, Turn-on voltage of green OLED applied ZnO was 14 [V] and luminance was 6,332 [$cd/m^2$].

Optical Properties of Organic Light Emitting Diode and Characteristics of ITO by Variation of Radio Frequency Plasma Power (Radio Frequency Plasma Power변화에 따른 ITO 특성 및 OLED의 광학적 특성)

  • Ki, Hyun-Chul;Kim, Hwe-Jong;Hong, Kyung-Jin;Kim, En-Mei;Gu, Hal-Bon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.1
    • /
    • pp.81-85
    • /
    • 2009
  • We has been analysed optical properties of OLED(organic light emitting diode) and characteristics of ITO(Indium Tin Oxide) in terms of $O_2$ plasma treatment for manufacturing high efficiency OLED, RF power of $O_2$ plasma was changed 25, 50, 100, 200 W. $O_2$ gas flow, gas pressure and treatment time were fixed. Sheet resistance and surface roughness of ITO were measured by Hall-effect measurement system and AFM, respectively. The ranges of sheet resistance and surface roughness were $5.5{\sim}6,06\;{\Omega}$ and $2.438{\sim}3.506\;nm$ changing of RF power, respectively, PM(Passive Matrix)OLED was fabricated with the structure of ITO(plasm treatment)/TPD($400\;{\AA}$)/$Alq_3(600\;{\AA})$/LiF($5\;{\AA}$)/Al($1200\;{\AA}$). Turn-on voltage of PMOLED was 7 V and luminance was $7,371\;cd/m^2$ at the RF power of 25 W, $O_2$ plasma treatment of ITO surface was result in lowering the operating voltage and improving luminance of PMOLED.

The Effects of Deposition Rate on the Physical Characteristics of OLEDs (유기발광 다이오드의 물성에 미치는 증착속도의 영향)

  • Lee, Young-Hwan;Cha, Ki-Ho;Kim, Weon-Jong;Lee, Jong-Yong;Kim, Gwi-Yeol;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.54-55
    • /
    • 2006
  • Organic light-emitting diodes(OLEOs) are attractive because of possible application in display with low operating voltage, low power consumption, self-emission and capability of multicolor emission by the selection of emissive material. We investigated the effects of deposition rate on the electrical characteristics, physical characteristics and optical characteristics of OLEOs in the ITO(indium-tin-oxide)/N.N'-diphenyl-N,N'-bis(3-methyphenyl)-1,1'-biphenyl-4,4'-diamine(TPD)/tris(8-hydroxyquinoline)aluminum($Alq_3$)/Al device. We measured current density, luminous flux and luminance characteristics of devices with varying deposition rates of TPD and $Alq_3$. It has been found that optimal deposition rate of TPD and $Alq_3$ were respectively $1.5{\AA}/s$ from the device structure. An AFM measurement results, surface roughness of the deposited film was the lowest when deposition rate was $1.5{\AA}/s$.

  • PDF

A Large Sky Simulator : A Reproduction of CIE Sky Condition and Daylighting Evaluation using Scale Model

  • Yu, In-Hye;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.1-10
    • /
    • 2007
  • KH University has developed a large sky simulator which is its scale suits international standard. To verify the reliability of the sky simulator, the luminance of 36 points on the inner sky surface was measured and compared with the CIE standard overcast sky model. It was found that the sky simulator can reproduce the CIE standard overcast sky condition with 1.8[%] of mean difference. To identify the differences of daylighting performance, scale model measurements were taken under a real sky and in a sky simulator. Under overcast sky conditions, two kinds of scale model experiments were conducted by using the photometric sensor Li-cor. Firstly, a 1/20 scale model of a side-lit office room 4.9[m] wide, 7.2[m] long, and 2.6[m] high was created. Five measurement points were set at 1.2[m], 2.4[m], 3.6[m], 4.8[m], and 6.0[m] from the window. The mean difference of the light factor between the sky simulator and real sky was 7.1[%]. Secondly, a 1/30 scale model of a top-lit atrium 15[m] wide, 15[m] long, and 15[m] high was created. The measurement point was set at center of the room and the well indexes of the model were set in 5 types. The mean difference of the light factor between the sky simulator and real sky was 1.7[%]. This proved that the sky simulator is fully accurate and usable for daylighting research.

A Design of Real-time Automatic Focusing System for Digital Still Camera Using the Passive Sensor Error Minimization (수동 센서의 오차 최소화를 이용한 실시간 DSC 자동초점 시스템 설계)

  • Kim, Geun-Seop;Kim, Deok-Yeong;Kim, Seong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.5
    • /
    • pp.203-211
    • /
    • 2002
  • In this paper, the implementation of a new AF(Automatic Focusing) system for a digital still camera is introduced. The proposed system operates in real-time while adjusting focus after the measurement of distance to an object using a passive sensor, which is different from a typical method. In audition, measurement errors were minimized by using the data acquired empirically, and the optimal measuring time was obtained using EV(Exposure Value) which is calculated from CCD luminance signal. Moreover, this system adopted an auxiliary light source for focusing in absolute dark conditions, which is very hard for CCD image Processing. Since this is an open-loop system adjusting focus immediately after the distance measurement, it guarantees real-time operation. The performance of this new AF system was verified by comparing the focusing value curve obtained from AF experiment with the one from the measurement by MF(Manual-Focusing). In both case, edge detector was used for various objects and backgrounds.

The Analysis for PDP Discharge as a Parameter of Electrode Structure by 3-Dimensional Light Emission Measurement (3차원 광 측정을 통한 PDP의 전극 구조별 방전 분석)

  • Woo, Seok-Gyun;Choi, Hoon-Young;Lee, Seok-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.190-196
    • /
    • 2001
  • We measured 3-dimensional images of the light emitted from plasma display panel(PDP) by using newly proposed scanned point detecting method(SPDM). The SPDM has the point detector with pinhole. The light emitted from PDP cell at the in-focus position can pass through the pinhole and be collected by detector. On the contrary, the light emitted from PDP cell at the out-of-focus positions is focused on the front of or the behind of the pinhole. We could analyze the characteristic of 3-dimensional light emission distribution by SPDM. From 3-dimensional measurement of 828[nm], the efficient design of PDP cell, the importance of opening ration, and the relations between BUS electrode position and discharge intensity are obtained. Also, the relationship between discharge characteristics and sustain electrode structures in AC-PDP are studied by measuring luminance, current, and discharge voltage.

  • PDF

Fast Estimation of Three-dimensional Spatial Light Intensity Distribution at the User Position of an Autostereoscopic 3D Display by Combining the Data of Two-dimensional Spatial Light Intensity Distributions

  • Hyungki Hong
    • Current Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.307-312
    • /
    • 2024
  • Measuring the three-dimensional (3D) spatial light intensity distribution of an autostereoscopic multiview 3D display at the user position is time-consuming, as luminance has to be measured at different positions around the user position. This study investigates a method to quickly estimate the 3D distribution at the user position. For this purpose, a measurement setup using a white semitransparent diffusing screen or a two-dimensional (2D) spatial sensor was devised to measure the 2D light intensity distribution at the user position. Furthermore, the 3D spatial light intensity distribution at the user position was estimated from these 2D distributions at different viewing distances. From the estimated 3D distribution, the characteristics of autostereoscopic 3D display performance can be derived and the candidate positions for further accurate measurement can be quickly determined.

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.

Design of Signal Measurement System for In-Building Propagation Characteristics based on Signature Sequence (시그니처 시퀀스 기반 건물 내 메시지 전달특성 측정시스템 설계)

  • Kim, Jeong-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.3-6
    • /
    • 2015
  • Recently, the collection of the sensor data and its analysis become important as the smart buildings equipped with the various sensors appear as a usual scene. The interconnection through the wire cable among the sensors is indispensible because of the information collections such as the temperature, the humidity, and the luminance in the rooms and the hallways for the effective management of the in-building energies. However, these interconnections through the cabling will be very costly, time-consuming, and a difficult task since they will cause some damages to the buildings. Therefore, the interconnections through the unwired connections are required in terms of the deployment effectiveness such as time and cost In this paper, the design and the operation appropriateness are confirmed through the simulation of the signal measurement system for in-building propagation characteristics based on signature sequence.

Improved Angle-of-View Measurement Method for Display Devices

  • Lee, Eun-Jung;Chong, Jong-Ho;Yang, Sun-A;Lee, Hun-Jung;Shin, Mi-Ok;Kim, Su-Young;Choi, Dong-Wook;Lee, Seung-Bae;Lee, Han-Yong;Berkeley, Brian H.
    • Journal of Information Display
    • /
    • v.11 no.1
    • /
    • pp.17-20
    • /
    • 2010
  • With the increasing demand for a better FPD image quality, better evaluation metrics and advanced display quality measurement methods are required to meet these needs. There are many measurement methods for evaluating the viewing angle of various display devices, but these methods, which include luminance drop, color shift, and contrast ratio decrease, are imperfect considering that human perception does not completely correlate to them. In this paper, a new method of measuring the perceptual angle of FPDs is proposed, considering human visual perception, which uses the color space of the color appearance model.