• Title/Summary/Keyword: Low-floor

Search Result 694, Processing Time 0.033 seconds

Design and Implementation of Low-Floor Bus Reservation System for the Transportation Weak (교통약자를 위한 저상버스 탑승 예약 시스템 설계 및 구현)

  • Heo, Seongsu;Choi, Youngkon;Park, Yoohyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.6
    • /
    • pp.39-46
    • /
    • 2018
  • Low-floor buses service in Korea has been spreading nationwide for transportation users with wheelchair since 2004. However, there is a lot of difficulty in using this information because the low-floor bus information is insufficient. Therefore, it is necessary to improve the service of using low-floor buses for the transportation weak in order to increase the usage rate of low-floor buses for those who use wheelchairs. In this paper, we designed and implemented a low-floor bus reservation system to provide low-floor bus service and low-floor bus reservation service to improve low-floor bus service of wheelchair users. The application of this system is expected to provide a better service to the transportation weak people using low - floor buses.

Performance of floor coverings by impact sound (실 충격원에 대한 바닥마감재 성능 분석)

  • Chung, Jinyun;Im, Jungbin;Lee, Sungchan;Kim, Kyoungwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.419-422
    • /
    • 2014
  • Floor impact sound level is affected by various factors. This study was examined about impact sources and floor coverings influenced at floor impact sound. So this study wishes to get method to reduce sound pressure level of receiving room. Light-weight impact sound in mid frequency and Heavy-weight impact sound in low frequency was affected by floor coverings. Therefore, method to reduce floor impact sound level is to use proper floor coverings. Some coverings can amplify the heavy-weight impact sound in low frequency. Floor impact sound sources used measurement and analysis were standard heavy-impact source(Tapping, Bang, Ball) and living impact sources(Cleaner, Chair, Toy-car, Soccer ball). And Floor coverings used measurements were various thickness vinyl, laminate(or ply-wood) floor. Especially vinyl floor coverings were very effective method to reduce floor impact.

  • PDF

Manual Development Research for the Diagnosis of the Introduction of Low-Floor Bus (저상버스 도입진단 매뉴얼 개발 연구)

  • Seung jun Lee;Seong yeon Kim;Won Jun Lee;Hyunjun Park;Choul Ki Lee;Nam sun Kim
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.6
    • /
    • pp.208-222
    • /
    • 2023
  • With the recent revision of 「Act on Promotion of the Transportation Convenience of Mobility Disadvantaged Persons」 and the Enforcement Regulations of the Act, bus business operators must introduce low-floor buses when scrapping buses. On the other hand, in the case of routes where low-floor buses cannot be operated, bus business operators can be exempted from introducing low-floor buses with the approval of their transportation administrative agency according to Article 4-2 of 「Enforcement Regulation of the Act on Promotion of the Transportation Convenience of Mobility Disadvantaged Persons」. According to the data from the Korea Bus Transportation Associations Federation, approximately 5.9% of all city bus routes were surveyed as the exceptions to introducing low-floor buses. Nevertheless the proportion is expected to increase because some regions with difficulties introducing low-floor buses are not included when calculating the proportion. By confirming the process of approving exceptions for introducing low-floor buses through local governments, there was no specific examination method or standard for approval of exceptions. Hence, there is the problem that some routes are approved as exceptions to introducing low-floor buses, even though low-floor buses can be operated on those routes. Therefore, this study aims to develop a manual that can objectively diagnose the overall operation environment of low-floor buses, such as road geometry and road facilities. Future research plans to apply it to more cases and improve it for more precise application in various contexts.

Design of Low-floor Bus Reservation System For the Transportation Weak (교통약자를 위한 저상버스 탑승예약 시스템 설계)

  • Heo, Seong-Su;Yu, Yun-Sik;Park, Yoo-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.518-521
    • /
    • 2018
  • As public transportation use increases, studies are being conducted to consider user convenience using IoT data collected via the bus information system. A low-floor bus means a bus that is designed to be 20 cm lower than a normal bus and can be wheelchair-accessible. However, the system in which the transportation weak is provided to use the low-floor bus is less than the system provided to the general user. In order to use the low-floor bus smoothly, as in the case of the general user, the service system for the weak driver is needed. In this paper, a low - floor bus reservation system is designed to provide a service for low - rise bus users to conveniently use low - floor buses.

  • PDF

Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System (저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구)

  • Cho, Jinkyun;Park, Beungyong;Lee, Yongjun;Chong, Wonho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

Ambient Levels of CO and PM10 at Low- and High-floor Apartments in Industrial Complexes (산업단지 내 저층과 고층 아파트의 외기 중 호흡성분진과 일산화탄소 수준)

  • Jo, Wan-Kuen;Lee, Joon-Yeob
    • Journal of Environmental Science International
    • /
    • v.15 no.8
    • /
    • pp.719-725
    • /
    • 2006
  • Since low-floor apartments ate vertically closer to patting lots and roadways, it is hypothesized that residents in low-floor apartments may be exposed to elevated ambient levels of motet vehicle emissions compared to residents in high-floor apartments. The present study examined this hypothesis by measuring two motor vehicle source-related pollutants(CO and PM10) in ambient air of high-rise apartment buildings within the boundary of industrial complexes according to atmospheric stability The ambient air concentrations of CO and PM10 were higher for low-floor apartments than for high-floor apartments, regardless of atmospheric stability, The median concentration ratio of the low-floor air to high-floor alt ranged from 1.3 to 2.0, depending upon atmospheric stabilities, seasons and compounds. Moreover, the CO and PM10 concentrations were significantly higher in the winter and in the summer, regardless of the Hoot height. Atmospheric stability also was suggested to be important for the residents' exposure of high-rise apartment buildings to both CO and PM10. The median ratios of surface inversion air to non-surface inversion air ranged from 1.2 to 1.7 and from 1.0 to 1.6 lot PM10 and CO, respectively, depending upon seasons. Conclusively, these parameters(apartment floor height, season, and atmospheric stability) should be considered when evaluating the exposure of residents, living in high-rise apartment buildings, to CO and PM10. Meanwhile, the median PMl0 outdoor concentrations were close to or higher than the Korean annual standards for PM10, and the maximum PM10 concentrations substantially exceeded the Korean PM10 standard, thus suggesting the need for a management strategy for ambient PM 10. Neither the median nor the maximum outdoor CO concentrations, however, were higher than the Korean CO standard.

Design and Evaluation of a Low-floor Care-bed for Elderly People (고령자용 저상 요양침대의 설계 및 평가)

  • Bae, Ju-Hwan;Moon, Inhyuk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 2017
  • It was hard for a conventional care-bed to be realized to a low-floor position due to a complex actuation mechanism installed under the mattress support platform. In this paper a mechanism design to set a low-floor position as well as to adjust back- and leg-rest angles was proposed. A dual motor was applied to the back- and leg-rest mechanism of which design parameters were determined by an optimal method. An elevation mechanism was also designed to enlarge a limited stroke range up to two times of its original stroke using a pulley mechanism. An evaluation test was performed by five healthy subjects ($24.4{\pm}0.5yrs.$) when going up from a floor position to a preset best position which was set to the 240mm height for a prototype low-floor bed and to the 600mm height for a conventional bed. As a result, the moving distance was 38% lower than the conventional bed when the subject used the low-floor bed. It showed that the low-floor care-bed reduced physical burdens and was effective to assist activities of daily living of the elderly people.

A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

A study of traction motor for Bimodal low floor vehicle (바이모달 저상굴절차량용 견인전동기 설계에 관한 고찰)

  • Choi, Yeol-Jun;Park, Yeong-Ho;Choi, Jong-Mook;Mok, Jai-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.911-915
    • /
    • 2007
  • This paper deal with the design concept of traction motor for Bimodal low floor vehicles that are CNG(Compressed Natural Gas) hybrid bus and Fuel-cell bus. The design concept of the traction motor is studied in terms of electrical characteristics and mechanical construction. Finally, this paper introduces the characteristic of the traction motor for low floor vehicles which are applied in the world, and mentioned the detail design concept of traction motor.

  • PDF

Development of measurement equipment for hybrid propulsion system of bimodal tram (바이모달 트램의 직렬형 하이브리드 추진시스템 계측장비 개발)

  • Bae, Chang-Han;Chang, Se-Ky;Mok, Jai-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.241-248
    • /
    • 2010
  • A bimodal low-floor tram can provide the punctuality of trains and the flexibility of bus together to the passengers. Its propulsion system is a series hybrid type using a set of CNG engine generator and Li-polymer battery. This paper presents a development of the measurement equipment for fine-tuning of a series hybrid propulsion system of bimodal low-floor tram. Its configuration schemes are described and certified using the measurement data of bimodal low-floor tram.

  • PDF