• 제목/요약/키워드: Low-cost sampler

검색결과 8건 처리시간 0.027초

A Low-Cost Open-Source Air Sampler for the Sorbent Tube Sampling for TD-GC/MS Analysis

  • Jang, Hwa-yong;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • 제11권4호
    • /
    • pp.95-102
    • /
    • 2020
  • In this study, we provide full descriptions of how to make a low-cost and completely open-source laboratory-made air sampler that will be used for sample adsorption for thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) analysis. It is well known that harmful gases cause bad effects on human bodies, so it is necessary to identify the types and amounts of gases in industrial sites. One of the most commonly used methods for gas sampling is to utilize a sorbent tube using an air sampler. Commercially available air samplers are expensive, typically priced between $1,000 and $2,000, and their design often cannot be modified to fit the experiment. To address these shortcomings, we have developed a do-it-yourself (DIY) air sampler that is not only cheap enough, but also completely open-source. Furthermore, the performance of the fabricated air sampler was validated in conjunction with TD-GC/MS for the analysis of volatile compounds.

디지털 IF 다운 샘플러와 업 샘플러의 저전력 블록 필터링 아키텍처 (Low-Power Block Filtering Architecture for Digital IF Down Sampler and Up Sampler)

  • 장영범;김낙명
    • 한국통신학회논문지
    • /
    • 제25권5A호
    • /
    • pp.743-750
    • /
    • 2000
  • 본 논문에서는, 디지털 IF 다운 샘플러와 업 샘플러의 저전력 구현을 위한 블록 필터링 아키텍처를 제안한다. 소프트웨어 라디오와 같은 차세대 이동통신 방식에서 디지털 IF 다운 샘플러와 업 샘플러의 효율적인 구현방법이 더욱더 요구되어가고 있는 추세이다. 디지털 IF 다운 샘플러는 앞단에 데시메이션 필터를 수반하여 구성되며, 업 샘플러는 뒷단에 인터폴레이션 필터가 수반디어 구성된다. 본 논문의 다운 샘플러 아키텍처에서는 블록 필터링 구조가 갖는 병렬처리 구조를 이용하여 필터를 구현하였으며, 블록 필터링 아키텍처에서 구조적으로 생겨나는 업 샘플링을 직렬로 연결되는 다운 샘플러와 상쇄시킴으로서 효과적인 구조가 만들어짐을 보인다. 또한 업 샘플러 아키텍처에서는 인터폴레이션 필터의 블록 필터링에서 만들어지는 다운 샘플링이 앞단의 업 샘플러와 상쇄되어 병렬처리와 저속의 처리가 가능해짐을 보인다. 본 논문에서 제안된 아키텍처와 Polyphase 아키텍처를 비교 분석한다. 리와 저속의 처리가 가능해짐을 보인다. 본 논문에서 제안된 아키텍처와 Polyphase 아키텍처를 비교 분석한다.

  • PDF

서울시 PM2.5 공간 샘플링을 위한 Deployable Particulate Impact Sampler의 성능 검증 연구 (Reliability and Accuracy of the Deployable Particulate Impact Sampler for Application to Spatial PM2.5 Sampling in Seoul, Korea)

  • 오규림;허종배;이승묵;김선영
    • 한국대기환경학회지
    • /
    • 제33권3호
    • /
    • pp.277-288
    • /
    • 2017
  • Previous studies of health effects of $PM_{2.5}$ performed spatial monitoring campaigns to assess spatial variability of $PM_{2.5}$ across people's residences. Highly reliable portable and cost-effective samplers will be useful for such campaigns. This study aimed to investigate applicability of the Deployable Particulate Impact Sampler(DPIS), one of the compact impact samplers, to spatial monitoring campaigns of $PM_{2.5}$ in Seoul, Korea. The investigation focused on the consistency of $PM_{2.5}$ concentrations measured by DPISs compared to those by the Low-volume Cyclone sampler (LCS). LCS has operated at a fixed site in the Seoul National University Yeongeon campus, Seoul, Korea since 2003 and provided qualified $PM_{2.5}$ data. $PM_{2.5}$ sampling of DPISs was carried out at the same site from November 17, 2015 through February 3, 2016. $PM_{2.5}$ concentrations were quantified by the gravimetric method. Using a duplicated DPIS, we confirmed the reliability of DPIS by computing relative precision and mean square error-based R squared value ($R^2$). Relative precision was one minus the difference of measurements between two samplers relative to the sum. For accuracy, we compared $PM_{2.5}$ concentrations from four DPISs (DPIS_Tg, DPIS_To, DPIS_Qg, and DPIS_Qo) to those of LCS. Four samplers included two types of collection filters(Teflon, T; quartz, Q) and impaction discs(glass fiber filter, g; pre-oiled porous plastic disc, o). We assessed accuracy using accuracy value which is one minus the difference between DPIS and LCS $PM_{2.5}$ relative to LCS $PM_{2.5}$ in addition to $R^2$. DPIS showed high reliability (average precision=97.28%, $R^2=0.98$). Accuracy was generally high for all DPISs (average accuracy=83.78~88.88%, $R^2=0.89{\sim}0.93$) except for DPIS_Qg (77.35~78.35%, 0.82~0.84). Our results of high accuracy of DPIS compared to LCS suggested that DPIS will help the assessment of people's individual exposure to $PM_{2.5}$ in extensive spatial monitoring campaigns.

Technique for Soil Solution Sampling Using Porous Ceramic Cups

  • Chung, Jong-Bae
    • Applied Biological Chemistry
    • /
    • 제41권8호
    • /
    • pp.583-586
    • /
    • 1998
  • Porous ceramic cups are used for monitoring ion concentration in soil solutions in various time course and depth. A soil solution sampler was constructed in laboratory by inserting pliable perfluoroalkoxy(PFA) tubings into porous cup through holes in PVC rod segment which plugged top opening of the porous cup. The system was installed in drip irrigated soil in a vertical position, and nitrogen movement below the drip basin was monitored. To collect soil solution, vacuum in the cup was applied with a hand vacuum pump. The samples obtained were sufficient enough to run quantitative analyses for a number of chemicals. Nitrogen transformation and movement could be well defined, and the system seemed to be relevant to the other soil solution samplers in monitoring chemical movement in soil. Although this system has general deficiencies found in the other samplers using ceramic cup, it could be easily constructed at a low cost. Since the tubing was pliable, the cups could be installed in horizontal position, and this allows installations of the cups at more precise depth increments and also more precise samplings of soil solution at each depth.

  • PDF

안면도에서 대기 중 가스상 PAHs의 계절적 변동 (Seasonal Variation of Atmospheric Polycyclic Aromatic Hydrocarbons (PAHs) on Anmyeon Island)

  • 안준건;임운혁;심원준;김기범;김승규;이희일
    • Ocean and Polar Research
    • /
    • 제31권2호
    • /
    • pp.189-198
    • /
    • 2009
  • Passive air samplers with polyurethane foam (PUF) disks were employed to determine seasonal gas phase variation of polycyclic aromatic hydrocarbons (PAHs) in ambient air on Anmyeon island from March 2007 to January 2008. Sum of 13 PAHs ranged between $3.5\;ng/m^3$ and $27.6\;ng/m^3$. Total PAHs during the heating season was 6.2 times higher than non-heating season. The dominant PAHs components during sampling periods were low and middle molecular weight PAHs including phenanthrene, fluoranthene, pyrene and chrysene. Gas exchange fluxes of PAHs across the air-water interface of the Yellow Sea were calculated using a modified two-film exchange model. PAHs fluxes ranged from $196\;ng/m^2/d$ net volatilization during summer to $3830\;ng/m^2/d$ net absorption during winter. Passive air sampler provides a convenient and cost-effective tool for measuring averaged gas phase PAHs, which was successfully used for calculation of gas exchange flux of PAHs in the Yellow Sea.

Development of radioactive prospecting as tool for evaluating degree of granitic rocks weathering

  • Ishida Satoshi;Tsuchihara Takeo;Imaizumi Masayuki;Ohnishi Ryouichi
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.416-421
    • /
    • 2003
  • To develop an easy, low-cost method for evaluating the degree of weathering by radioactive prospecting, radioactive prospecting and the investigation of the degree of weathering were carried out in the southern Kitakami massif of Iwate Prefecture, Japan, in which weathering granitic rocks was distributed. Fifty outcrops in the study area were selected, and strength of the gamma-rays emitted from the weathering bedrock of $^{40}K,\;^{214}Bi,\;and\;^{208}Tl$ was measured for 15 minutes at each point. At the same points, soil hardness was measured on the surface of the outcrop with a Yamanaka soil penetration tester. In addition, 100cc samples of each outcrop were taken with the sampler. The samples were analyzed by XRD, and the kind of the rock-forming minerals containing K was identified. We then compared the degree of weathering and the radioactive prospecting results by using K as an indicator. The relation between $^{40}K/^{208}Tl$ gamma rays counting rate by the radioactive prospecting and the hardness index showed a positive correlation as a result of the investigation, and the correlation coefficient ($R^2$) was 0.67.Moreover, when $^{40}K/^{208}Tl$ gamma rays counting rate emitted from the bedrock was low, the number of rock-forming mineral species containing K was also low. Thus, it was found that $^{40}K/^{208}Tl$ gamma rays counting rate measured by the radioactive prospecting could be used as an indicator of the degree of weathering.

  • PDF

Comparison the Diagnostic Value of Dilatation and Curettage Versus Endometrial Biopsy by Pipelle - a Clinical Trial

  • Sanam, Moradan;Majid, Mir Mohammad Khani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.4971-4975
    • /
    • 2015
  • Background: Several methods have been presented for the evaluation of the endometrium in patients with abnormal uterine bleeding, which include minimal invasive and invasive approaches such as diagnostic curettage or endometrial biopsy by Pipelle. Many studies have been performed in order to compare two methods; diagnostic curettage and outpatient endometrial biopsy. This investigation compared sampling adequacy, endometrial histopathology, failure rates, duration and costs between diagnostic curettage in a hospital and endometrial biopsy. Materials and Methods: This single blind clinical trial was performed on 130 patients older than 35 years who was referred to Amir training hospital in 2013 for elective diagnostic curettage because of abnormal uterine bleeding. For all patients eligible for the study, an endometrial sample by Pipelle was taken without anesthesia or dilatation. Then under general anesthesia diagnostic curettage was performed by sharp curette. Sampling duration was calculated and both samples were sent to the same pathologist. The diagnostic values of two methods in the diagnosis of normal endometrium, endometrial hyperplasia and carcinoma were compared. The costs of these two methods were also compared. Data analysis was performed by SPSS (version 16.0) software. Chi-Square, Fisher, and Pearson tests were used and were considered statistically significant at P values less than 0.05. Results: Two methods were agreed upon 88% of sampling adequacy and 94% of pathological results. Specificity of 100% and sensitivity of 90% for detection of proliferative endometrium, secretory endometrium, simple hyperplasia without atypia and 100% for cancer were recorded. Pipelle diagnostic accuracy in comparison with curettage, have been reported over 97%, so the failure rate in this study was below 5%. Sensitivity of Pipelle for detection of atrophic endometrium was reported below 50%. Duration and cost was lower in Pipelle versus curettage. Conclusions: It is concluded that due to high agreement and cohesion coefficient between curettage and Pipelle on the issue of sampling adequacy, histopathology finding (except atrophic endometrium), low failure rate, duration of sampling and cost, Pipelle can be introduced as a suitable alternative of diagnostic curettage.

피스톤식 자유낙하 주상시료 채취기 (A Piston Type Free-fall Corer(KORDI-FFC))

  • 지상범;어영상
    • 한국해양학회지
    • /
    • 제30권4호
    • /
    • pp.365-370
    • /
    • 1995
  • 해양 퇴적물의 주상시료 채취를 위하여 사용되는 자유낙하 코어러(free-fall corer, FFC)는 조사선의 윈치와 케이블이 필요없고 소형 조사선에서도 사용이 가능한 장비이다. 심해저 광물지원 탐사시 탐사효율을 높이고자 새로 개발된 피스톤형 자유낙 하 코어러는 KORDI-FFC라 명명되었다. 이 장비는 이 장비는 피스톤 코어러(piston corer)와 자유낙하 코어러의 장점이 조합된 채취기로, 열린 배럴의 중력 코어러(open barrel gravity corer)를 변조하여 만든 기존의 자유낙하 코어러의 단점이 보강되었고 양질의 시료가 채취되도록 설계되었다. 본 장비를 진해만과 제주부근 해역에서 4회에 걸쳐 투하한 결과 교란이 적은 표층 퇴적물 시료가 성공적으로 채취되었다. 시험 결과 본 장비는 심해저 및 천해저에서 원치와 케이클, 갑판의 A-frame, 또는 해상 크레인 없는 소형 선박에서도 사용이 가능하고, 또한 최단 시간에 퇴적물 시료를 채취하며, 본 장비의 사용과 동시에 선상에서 자유롭게 다른 작업을 할 수 있고, 제작 및 소모 비용이 저렴하며, 표층퇴적물의 교란이 적은 양질의 시료를 채취할 수 있는 장점이 있 다.

  • PDF